Loading...
HomeMy WebLinkAboutB15-0041_A000 COVER_1470342600.pdfDRAWING INDEX CIVIL: C-0 SURVEY C-1 DRAINAGE PLAN XBS1 SHORING COVER SHEET XBS2 SHORING PLAN XBS3 SHORING ELEVATION VIEW & DETAILS LANDSCAPE: L1 SITE & GRADING PLAN L2 PLANTING PLAN ARCHITECTURAL: A001 CONSTRUCTION STAGING PLAN A002 GRFA CALCULATIONS A003 BASEMENT DEDUCTION CALCS. A004 SITE COVERAGE A005 ROOF HEIGHT CALCS A006 SITE PLAN FLOOR PLANS A100 CRAWL SPACE PLAN A101 BASEMENT FLOOR PLAN A102 GARAGE & MAIN LEVEL FLOOR PLAN A103 MASTER & UPPER LEVEL FLOOR PLAN A120 ROOF PLAN A130 BASEMENT RCP A131 MAIN LEVEL RCP A132 UPPER LEVEL RCP A140 BASEMENT FINISH & POWER PLAN A141 MAIN LEVEL FINISH & POWER PLAN A142 UPPER LEVEL FINISH & POWER PLAN ELEVATIONS A201 EAST ELEVATION A202 NORTH ELEVATION A203 SOUTH ELEVATION A204 WEST ELEVATION A210 SWISS PEARL PANEL LAYOUT A211 SWISS PEARL PANEL LAYOUT A212 SWISS PEARL PANEL LAYOUT SECTIONS & DETAILS A301 BUILDING SECTIONS A302 BUILDING SECTIONS A303 BUILDING SECTIONS A304 BUILDING SECTIONS A305 BUILDING SECTIONS A306 BUILDING SECTIONS A307 BUILDING SECTIONS A401 WALL SECTIONS A402 WALL SECTIONS A410 STAIR PLANS & SECTIONS A411 INTERIOR STAIR DETAILS A412 INTERIOR STAIR DETAILS A414 EXT. STAIR & GUARDRAIL DETAILS A415 GUARDRAIL LAYOUTS A420 GREAT ROOM FIREPLACE A421 FAMILY RM. & SUITE 3 FIREPLACE A422 MASTER FIREPLACE A430 HOT TUB & DINING DECK A501 TYPICAL WALL DETAILS A502 DETAILS A510 TYPICAL ROOF DETAILS A511 DECK DETAILS A512 BUTTERFLY ROOF DETAILS A513 LIGHTING DETAILS A514 LIGHTING DETAILS A515 LIGHTING DETAILS WINDOWS & DOORS A601 WINDOW SCHEDULE A602 WINDOW SCHEDULE CONT. A603 WINDOW DETAILS (EBE DOOR) A604 WINDOW DETAILS (EBE PIVOT) A605 WINDOW DETAILS (EBE LIFT SLIDE) A606 WINDOW DETAILS (REC ROOM) A607 WINDOW DETAILS (MASTER) A608 WINDOW DETAILS (OS2 77) A609 WINDOW DETAILS (EBE 85) A610 DOOR SCHEDULE STRUCTURAL: S1A SITE STABILIZATION PLAN & EXCAVATION PLAN S2A FOUNDATION PLAN S2B DRIVEWAY FOUNDATION PLAN S3 FOUNDATION DIMENSIONS S4 LEVEL 2 & 1 FRAMING PLAN S5 MECHANICAL CEILING FRAMING PLAN S6 LEVEL 4 & 3 FRAMING PLAN S7 LOWER ROOF, LEVEL 6 & 5 FRAMING PLAN S8 UPPER ROOF FRAMING PLAN S9 DETAILS S10 DETAILS S11 DETAILS S12 DETAILS S13 DETAILS S14 DETAILS S15 DETAILS S16 DETAILS S17 DETAILS S18 DETAILS S19 DETAILS S20 DETAILS S21 DETAILS S22 DETAILS MECHANICAL: M0.1 MECHANICAL ZONING PLAN M0.2 RADON MITIGATION PLAN M1.0 MECHANICAL SCHEDULES M1.1 MECHANICAL SCHEDULES M2.0 CRAWLSPACE PLAN M2.1 BASEMENT PLAN M2.2 MAIN LEVEL PLAN M2.3 UPPER LEVEL PLAN M3.0 MECHANICAL SCHEMATICS M4.0 MECHANICAL SPECIFICATIONS ELECTRICAL: E1.0 ELECTRICAL LOAD CALCS LIGHTING: AL1 SITE LIGHTING AL2 BASEMENT LIGHTING AL3 MAIN LEVEL LIGHTING AL4 UPPER LEVEL LIGHTING LOW VOLTAGE: LV SYSTEMS OVERVIEW 01 BASEMENT LEVEL 02 MAIN LEVEL 03 UPPER LEVEL INTERIOR ELEVATIONS: A801 SPA BATH A802 SPA BATH CONT. A803 BUNK BATH A804 GUEST BATH A805 POWDER ROOMS A806 BATH 3 (JOSH) A807 BATH 2 (NIKKI) A808 BATH 1 (BRANDON) A809 MASTER BATH A810 MASTER BATH CONT. A820 GYM A821 MASSAGE ROOM A822 REC ROOM BAR A823 REC ROOM A824 GAME ROOM A825 BUNK ROOM A826 GUEST SUITE A827 LAUNDRY ROOM A828 FAMILY ROOM A829a KITCHEN A829b ISLAND A829c BAR A829d PANTRY A830 GREAT ROOM A831 ENTRY & DINING A832 SUITE 3 (JOSH) A833 SUITE 2 (NIKKI) A834 SUITE 1 (BRANDON) A835 UPPER HALL & BRIDGE A836 OFFICE A837 MASTER SUITE A838 HER MASTER CLOSET A839 HIS MASTER CLOSET WILLIAM OHS DRAWINGS: PAGE 1 GENERAL NOTES PAGE 2 KITCHEN FLOOR PLANS PAGE 3 KITCHEN ELEVATIONS PAGE 4 KITCHEN ELEVATIONS PAGE 5 BAR ELEVATIONS PAGE 6 PANTRY PAGE 7 LOWER BAR Project number Date Drawn by 4/18/2016 11:15:17 AM A000 COVER SHEET 103ROCK VAIL, CO 103 ROCKLEDGE ROAD 041816 LJF REVISION 7 04.18.16 103 ROCKLEDGE ROAD GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. VAIL VILLAGE FIRST FILING/ RAETHER MINOR SUBDIVISION/ BLOCK 7/ LOT 4 PROJECT SUMMARY: CODE: IRC 2012 ZONING: SINGLE FAMILY RESIDENTIAL OCCUPANCY CLASSIFICATION: TYPE R DIV. 3 PROJECT TEAM: ARCHITECT: K. H. WEBB ARCHITECTS 710 W. LIONSHEAD CIRCLE, UNIT A VAIL, CO 81657 PH: 970.477.2990 CONTACTS: KYLE WEBB/ LAUREN FORD GENERAL CONTRACTOR: SHAEFFER HYDE CONSTRUCTION PO BOX 373 VAIL, CO 81657 PH: 970.790.1522 CONTACT: DENNIS THOMPSON LANDSCAPE ARCHITECT: CERES PLUS PO BOX 2134 EAGLE, CO 81631 PH: 970.949.3286 CONTACTS: SCOTT STRUCTURAL ENGINEER: THE MJ MUELLER CO, INC. PO BOX 2747 VAIL, CO PH: 970.476.2627 CONTACT: MARK MUELLER MECHANICAL ENGINEER: RADER ENGINEERING INC. PO BOX 8610 AVON, CO 81620 PH: 970.845.7910 CONTACTS: JEFF & DREW LIGHTING DESIGNER: HEFFERAN PARTNERSHIP 205 CAMDEN PLACE BOULDER, CO 80302 PH: 303.447.3566 CONTACT: KRYSTAL No. Description Date 7 Revision 7 2016 7 7 7 08/04/16