HomeMy WebLinkAboutB15-0041_A000 COVER_1470342600.pdfDRAWING INDEX
CIVIL:
C-0 SURVEY
C-1 DRAINAGE PLAN
XBS1 SHORING COVER SHEET
XBS2 SHORING PLAN
XBS3 SHORING ELEVATION VIEW & DETAILS
LANDSCAPE:
L1 SITE & GRADING PLAN
L2 PLANTING PLAN
ARCHITECTURAL:
A001 CONSTRUCTION STAGING PLAN
A002 GRFA CALCULATIONS
A003 BASEMENT DEDUCTION CALCS.
A004 SITE COVERAGE
A005 ROOF HEIGHT CALCS
A006 SITE PLAN
FLOOR PLANS
A100 CRAWL SPACE PLAN
A101 BASEMENT FLOOR PLAN
A102 GARAGE & MAIN LEVEL FLOOR PLAN
A103 MASTER & UPPER LEVEL FLOOR PLAN
A120 ROOF PLAN
A130 BASEMENT RCP
A131 MAIN LEVEL RCP
A132 UPPER LEVEL RCP
A140 BASEMENT FINISH & POWER PLAN
A141 MAIN LEVEL FINISH & POWER PLAN
A142 UPPER LEVEL FINISH & POWER PLAN
ELEVATIONS
A201 EAST ELEVATION
A202 NORTH ELEVATION
A203 SOUTH ELEVATION
A204 WEST ELEVATION
A210 SWISS PEARL PANEL LAYOUT
A211 SWISS PEARL PANEL LAYOUT
A212 SWISS PEARL PANEL LAYOUT
SECTIONS & DETAILS
A301 BUILDING SECTIONS
A302 BUILDING SECTIONS
A303 BUILDING SECTIONS
A304 BUILDING SECTIONS
A305 BUILDING SECTIONS
A306 BUILDING SECTIONS
A307 BUILDING SECTIONS
A401 WALL SECTIONS
A402 WALL SECTIONS
A410 STAIR PLANS & SECTIONS
A411 INTERIOR STAIR DETAILS
A412 INTERIOR STAIR DETAILS
A414 EXT. STAIR & GUARDRAIL DETAILS
A415 GUARDRAIL LAYOUTS
A420 GREAT ROOM FIREPLACE
A421 FAMILY RM. & SUITE 3 FIREPLACE
A422 MASTER FIREPLACE
A430 HOT TUB & DINING DECK
A501 TYPICAL WALL DETAILS
A502 DETAILS
A510 TYPICAL ROOF DETAILS
A511 DECK DETAILS
A512 BUTTERFLY ROOF DETAILS
A513 LIGHTING DETAILS
A514 LIGHTING DETAILS
A515 LIGHTING DETAILS
WINDOWS & DOORS
A601 WINDOW SCHEDULE
A602 WINDOW SCHEDULE CONT.
A603 WINDOW DETAILS (EBE DOOR)
A604 WINDOW DETAILS (EBE PIVOT)
A605 WINDOW DETAILS (EBE LIFT SLIDE)
A606 WINDOW DETAILS (REC ROOM)
A607 WINDOW DETAILS (MASTER)
A608 WINDOW DETAILS (OS2 77)
A609 WINDOW DETAILS (EBE 85)
A610 DOOR SCHEDULE
STRUCTURAL:
S1A SITE STABILIZATION PLAN & EXCAVATION PLAN
S2A FOUNDATION PLAN
S2B DRIVEWAY FOUNDATION PLAN
S3 FOUNDATION DIMENSIONS
S4 LEVEL 2 & 1 FRAMING PLAN
S5 MECHANICAL CEILING FRAMING PLAN
S6 LEVEL 4 & 3 FRAMING PLAN
S7 LOWER ROOF, LEVEL 6 & 5 FRAMING PLAN
S8 UPPER ROOF FRAMING PLAN
S9 DETAILS
S10 DETAILS
S11 DETAILS
S12 DETAILS
S13 DETAILS
S14 DETAILS
S15 DETAILS
S16 DETAILS
S17 DETAILS
S18 DETAILS
S19 DETAILS
S20 DETAILS
S21 DETAILS
S22 DETAILS
MECHANICAL:
M0.1 MECHANICAL ZONING PLAN
M0.2 RADON MITIGATION PLAN
M1.0 MECHANICAL SCHEDULES
M1.1 MECHANICAL SCHEDULES
M2.0 CRAWLSPACE PLAN
M2.1 BASEMENT PLAN
M2.2 MAIN LEVEL PLAN
M2.3 UPPER LEVEL PLAN
M3.0 MECHANICAL SCHEMATICS
M4.0 MECHANICAL SPECIFICATIONS
ELECTRICAL:
E1.0 ELECTRICAL LOAD CALCS
LIGHTING:
AL1 SITE LIGHTING
AL2 BASEMENT LIGHTING
AL3 MAIN LEVEL LIGHTING
AL4 UPPER LEVEL LIGHTING
LOW VOLTAGE:
LV SYSTEMS OVERVIEW
01 BASEMENT LEVEL
02 MAIN LEVEL
03 UPPER LEVEL
INTERIOR ELEVATIONS:
A801 SPA BATH
A802 SPA BATH CONT.
A803 BUNK BATH
A804 GUEST BATH
A805 POWDER ROOMS
A806 BATH 3 (JOSH)
A807 BATH 2 (NIKKI)
A808 BATH 1 (BRANDON)
A809 MASTER BATH
A810 MASTER BATH CONT.
A820 GYM
A821 MASSAGE ROOM
A822 REC ROOM BAR
A823 REC ROOM
A824 GAME ROOM
A825 BUNK ROOM
A826 GUEST SUITE
A827 LAUNDRY ROOM
A828 FAMILY ROOM
A829a KITCHEN
A829b ISLAND
A829c BAR
A829d PANTRY
A830 GREAT ROOM
A831 ENTRY & DINING
A832 SUITE 3 (JOSH)
A833 SUITE 2 (NIKKI)
A834 SUITE 1 (BRANDON)
A835 UPPER HALL & BRIDGE
A836 OFFICE
A837 MASTER SUITE
A838 HER MASTER CLOSET
A839 HIS MASTER CLOSET
WILLIAM OHS DRAWINGS:
PAGE 1 GENERAL NOTES
PAGE 2 KITCHEN FLOOR PLANS
PAGE 3 KITCHEN ELEVATIONS
PAGE 4 KITCHEN ELEVATIONS
PAGE 5 BAR ELEVATIONS
PAGE 6 PANTRY
PAGE 7 LOWER BAR
Project number
Date
Drawn by
4/18/2016
11:15:17 AM
A000
COVER SHEET
103ROCK
VAIL, CO
103 ROCKLEDGE
ROAD
041816
LJF
REVISION 7 04.18.16
103 ROCKLEDGE ROAD
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY
WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR
DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN
APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE
PARTICULAR AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS,
OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS
ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS
OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE
BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET
ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR
TYPES.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR
WINDOW TYPES.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR
AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR
FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE
ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY
IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE
CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED
BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE.
COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK
THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND
REGIONAL CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND
OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR
DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER
STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE
CONSTRUCTION.
12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE
BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE
WORK.
13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK
SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL
PROBLEMS WITH THESE SURFACES.
14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN
APPROVAL.
15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR
AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES,
EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE
INDUSTRY.
16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS
WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.
17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING
UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS
TO THE SITE.
18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE
ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL
AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED
LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND
WITH THE NON-DISTURBED LANDSCAPE.
19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER.
20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE
CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR
LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT.
VAIL VILLAGE FIRST FILING/ RAETHER MINOR SUBDIVISION/ BLOCK 7/ LOT 4
PROJECT SUMMARY:
CODE:
IRC 2012
ZONING:
SINGLE FAMILY RESIDENTIAL
OCCUPANCY CLASSIFICATION:
TYPE R DIV. 3
PROJECT TEAM:
ARCHITECT:
K. H. WEBB ARCHITECTS
710 W. LIONSHEAD CIRCLE, UNIT A
VAIL, CO 81657
PH: 970.477.2990
CONTACTS:
KYLE WEBB/ LAUREN FORD
GENERAL CONTRACTOR:
SHAEFFER HYDE CONSTRUCTION
PO BOX 373
VAIL, CO 81657
PH: 970.790.1522
CONTACT: DENNIS THOMPSON
LANDSCAPE ARCHITECT:
CERES PLUS
PO BOX 2134
EAGLE, CO 81631
PH: 970.949.3286
CONTACTS: SCOTT
STRUCTURAL ENGINEER:
THE MJ MUELLER CO, INC.
PO BOX 2747
VAIL, CO
PH: 970.476.2627
CONTACT: MARK MUELLER
MECHANICAL ENGINEER:
RADER ENGINEERING INC.
PO BOX 8610
AVON, CO 81620
PH: 970.845.7910
CONTACTS: JEFF & DREW
LIGHTING DESIGNER:
HEFFERAN PARTNERSHIP
205 CAMDEN PLACE
BOULDER, CO 80302
PH: 303.447.3566
CONTACT: KRYSTAL
No. Description Date
7 Revision 7 2016
7
7
7
08/04/16