HomeMy WebLinkAboutB15-0041_A100 CRAWL_1470342600.pdf<5' TALL MECHANICAL CRAWL SPACE CONCRETE SLAB & FOUNDATIONS PER STRUCTURAL DWGS TYPE "X" GWB ON ALL CEILINGS MECHANICAL VENTILATION 1 CFM PER 50 SF OF FLOOR AREA MAX CRAWL SPACE ACCESS OPENING 12 SF TRENCHED ACCESS TO BASEMENT MECH. ROOM ACCESS HATCH 8248' - 2" 1 2 3 4 5 6 E D B BX 1X 2X 1X' C A 12 SF FIRE RATED ACCESS HATCH TO CRAWL SPACE S.O.G. S.O.G. <5' TALL MECHANICAL CRAWL SPACE CONCRETE SLAB & FOUNDATIONS PER STRUCTURAL DWGS TYPE "X" GWB ON ALL CEILINGS MECHANICAL VENTILATION 1 CFM PER 50 SF OF FLOOR AREA MAX CRAWL SPACE ACCESS OPENING 12 SF CRAWL SPACE 25 AX AX' 1 2 3 4 5 6 E D B BX 1X 2X 1X' C A AX AX' IN FLOOR OUTLETS VERIFY FINAL IN-SLAB DRAIN LOCATIONS FIELD COORDINATE FINAL IN-SLAB DRAIN LOCATIONS RECESSED PLANTERS SEE MECH. PLANS FOR ACESS & EQUIP LOCATIONS RADON CONTROL PER RADON ENGINEER: (TO COMPLY WITH IRC 2012) 1. DRAIN-TILE & STUB OUT UNDER SLAB & GRAVEL 2. 6 MIL. VISQUEEN OVER GRAVEL 3. PERIM. SEAL W/ ONE PART POLYURETHANE CAULKING 4. INSTALL RADON FAN & NECCESS. PIPING TO CONNECT DIFFERENT ELEVATIONS 5. EXACT LOCATION OF PIPES TBD BY CONSULTANT PER SITE VISIT 6. ALL ENTRY ROUTES SHALL BE SEALED W/ ONE PART POLYURETHANE CAULKING 7. DAMPROOFING ON ALL PORTIONS OF CONCRETE & MASONRY FDN WALLS BELOW GRADE PER IRC 8. CRAWL SPACE ACCESS DOORS SHALL BE GASKETED TO PREVENT AIR LEAKAGE Project number Date Drawn by 4/18/2016 11:16:10 AM A100 CRAWL SPACE PLAN 103ROCK VAIL, CO 103 ROCKLEDGE ROAD 041816 LJF 1/4" = 1'-0" 1 _CRAWL SPACE No. Description Date 08/04/16