HomeMy WebLinkAboutB15-0041_A501 DETAI_1470342600.pdfQUARTZITE STONE PLANKING PER ARCH
SPEC.; MORTAR ADHERED
METAL LATH O/ DELTA DRY STUCCO & STONE
RAINSCREEN W/ FABRIC MORTAR SCREEN
(FACING EXT.); DON'T OVERDRIVE SCREWS, USE
PLASTIC SPACERS AS REQD. & ATTACH TO
STUDS W/ MIN. 3/4" PENETRATION
2" NAILABLE RIGID POLY ISO INSUL. HUNTER
Xci NB OR SIM. (R-9.6)
PLYWOOD SHEATHING PER STRUCTURAL
1-1/2" (MIN.) CONT. SPRAY POLYURETHANE
INSULATION (SPF), IN WALL (R-9.9)
FILL REMAINDER OF WALL W/ BIBS INSUL.
BACKER BOARD
MORTAR BED
STONE VENEER PER ARCH SPEC
FURRING & ADDL. SUPPORT AS REQD.
R-23 (MIN) INSULATION FOR THE FULL
ASSEMBLY
EXTERIOR: INTERIOR:
2X WALL PER STRUCTURAL
1 LAYER OF BUILDING PAPER GRADE
D 60 MIN. O/ (WRB/AB) DELTA VENT S
APPLY BASE COAT O/ METAL LATH
DELTA BUG SCREEN @ TOP & BOTTOM
OF WALL FOR VENTILATION; ALSO @
OPENINGS GREATER THAN 6'
1X10 CLEAR VERTICAL GRAIN
(CVG) CEDAR SHIPLAP SIDING,
WIRE BRUSHED & STAINED PER
APPROVED SAMPLE, SLOPE
BOTTOM EDGE
VERTICAL BATTENS,
ATTACH TO STUDS
2" NAILABLE RIGID POLY ISO
INSUL.; HUNTER Xci NB OR
SIM. (R-9.6)
PLYWOOD SHEATHING
PER STRUCTURAL
1-1/2" CONT. SPRAY
POLYURETHANE FOAM (SPF)
INSULATION, IN WALL (R-9.9)
5/8" GWB, LEVEL 4 FINISH, TYP.
(WRB/ AB) DELTA VENT S BEHIND
BATTENS, TAPE ALL LAPS W/
DELTA TAPE
R-23 (MIN) INSULATION FOR
THE FULL ASSEMBLY
EXTERIOR:
INTERIOR:
2X WALL PER STRUCTURAL
0' - 0 3/4"
FILL REMAINDER OF WALL W/
BIBS INSUL. 0' - 0 1/2"
SWISS PEARL COMPOSITE
CEMENT PANELS W/ 1/2"
REVEAL & CONCEALED
FASTNERS, SEE A210'S FOR
DIMENSIONS & LAYOUT
PANELS FASTENED TO METAL
RAIL & HANGER SYSTEM O/ 1/2"
METAL FURRING STRIPS
(PAINTED BLACK)
2" CONT. NAILABLE POLY ISO
RIGID INSULATION, HUNTER
Xci NB OR SIM
PLYWOOD SHEATHING PER
STRUCTURAL
(WRB/AB) DELTA FASSADE S
BEHIND BATTENS, TAPE ALL LAPS
W/ DELTA FASSADE TAPE
EXTERIOR:
2X WALL PER STRUCTURAL
R-32 INSULATION FOR THE FULL ASSEMBLY
5/8" GWB LEVEL 4 FINISH, TYP.
INTERIOR:
1-1/2" (MIN) CONT. SPF INSULATION, IN WALL
4" BIBS INSULATION
0' - 5 1/2"
FASTEN RAIL SYSTEM TO
STRUCTURE AS REQD.
STONE VENEER WALL BUILD UP,
TERMINATE 4" ABOVE GRADE
DELTA DRY STUCCO & STONE,
CONT. @ LEDGE, DELTA BUG
SCREEN @ BOTTOM
2" XPS INSUL. R-10 (MIN)
HYDROTECH HOT-APPLIED
RUBBERIZED ASPHALT WPM (MM6125
FR W/ HYDROFLEX 10)
FINISHED GRADE
1' - 2"
0' - 8"
2" XPS INSUL. R-10 (MIN)
2" NAILBASE RIGID POLY ISO
INSUL.
1' - 9 1/2"
BITUTHANE AT B.O. NAIL
BASE, LAP FDN. WALL 12" &
NAILBASE 24"
DRAINAGE MAT O/ INSUL.;
EXTEND O/ TOP OF LEDGE
SMF O/ P.T. BLOCKING @ BASE
PERIMETER DRAIN, W/ GRAVEL; 6" DIA. RIGID, PERF. PIPE
SLOPE 1/4"/ FT. TO DAYLIGHT OR SUMP PUMP LOCATION PER
SOILS REPORT
HYDROTECH HOT-APPLIED
RUBBERIZED ASPHALT WPM;
EXTEND 36" ABOVE GRADE & TO
B.O. FOOTING
2" XPS INSUL. R-10 MIN.
DRAINAGE MAT; EXTEND TO
INVERT OF PIPE
WATER STOP (ADCOR ES BY
GRACE), TYP.
CONCRETE FOUNDATION WALL
PER STRUCT.
UNDERSLAB GRAVEL PER
STRUCT.
2" XPS INSUL., TYP. WHERE
REQD. PER CODE
15 MIL. VAPOR RETARDER
STEGOWRAP; EXTEND 8" UP
SLAB EDGE, SEAL ALL JOINTS
S.O.G.
TOPPING SLAB W/ HEAT & FINISH
FLOOR PER PLANS
DRAIN TILE & STUB OUT PER
RADON ENGINEER
TYP. 2X FURRING WALL
1-1/2" (MIN) SPF INSULATION
FILTER FABRIC FACING SOIL
EXPANSION MATERIAL
PRESERVATIVE P.T. WOOD SILL
SEALANT
EXTEND WALL TO
UNDERSIDE OF STRUCTURE,
TYP.; SEAL GAPS
1-LAYER 5/8" TYPE "X" GWB
ON FIRE SIDE OF 2X
STRCTURAL WALL;
PROVIDE SOUND BATTS.
FIRE TAPE ALL JOINTS;
SEAL ALL GAPS & WALL
PENETRATIONS W/
ACOUSTICAL SEALANT.
MEET REQ. OF IRC SECT.
R309
SEALANT
GARAGE/ MECH.
HEATED
LIVING SPACE GARAGE
8265' - 6"
FINISHED FLOOR PER PLANS, OVER
LIGHTWEIGHT TOPPING SLAB WITH
RADIANT HEAT
PLYWOOD DECKING AND FRAMING
PER STRUCTURAL
TYPE X GWB; FIRE TAPE ALL
JOINTS & SEAL ALL GAPS PER IRC
HEATED LIVING SPACE
CRAWL SPACE/ GARAGE/ MECH.
R-38 MIN. FLOOR INSULATION
REQD. O/ UNHEATED SPACE, TYP.
PAINTED STEEL PANELS (OR
STEEL PLATE) TIGHT JOINTS, SEE
ELEVATIONS FOR LAYOUT
USE CONCEALED FASTENERS,
FASTEN TO 1X CEDAR VERTICAL
BATTENS COVERED W/ EPDM
2" CONT. NAILABLE POLY ISO
RIGID INSULATION, HUNTER
Xci NB OR SIM
PLYWOOD SHEATHING PER
STRUCTURAL
(WRB/AB) DELTA FASSADE S
EXTERIOR:
2X WALL PER STRUCTURAL
R-23 MIN. FOR THE FULL ASSEMBLY
5/8" GWB LEVEL 4 FINISH, TYP.
INTERIOR:
1-1/2" (MIN) CONT. SPF INSULATION,
IN WALL
4" BIBS INSULATION
18 GUAGE SHEET METAL (OR
3/16" STEEL PLATE O/ 1/2" P.T.
PLYWOOD
SMOOTH STUCCO FINISH O/
POURED CONCRETE SITE WALL
CONCRETE WALL PER
STRUCTURAL
DELTA-DRY STUCCO &
STONE VENTILATION
RAINSCREEN
SCRATCH COAT, BROWN COAT,
FINISH COAT O/ METAL LATH
DAMPROOFING OR
WATERPROOFING
DRAINAGE MAT TO DRAIN
PIPE @ B/O WALL
DRYSTACK MOUNTAIN
ASH STONE VENEER AT
DRIVEWAY SITE WALLS
CONCRETE WALL PER
STRUCTURAL
DELTA-DRY STUCCO &
STONE VENTILATION
RAINSCREEN
SHEET WP MEMBRANE; LAP
OVER BOTH SIDES OF WALL
DAMPROOFING OR
WATERPROOFING
DRAIN MAT TO
DRAIN PIPE @ B/O
WALL
Project number
Date
Drawn by 4/18/2016
11:19:52 AM
A501
TYP. WALL DETAILS
103ROCK
VAIL, CO
103 ROCKLEDGE
ROAD
041816
LJF
1 1/2" = 1'-0" 1
C- TYP STONE WALL
1 1/2" = 1'-0" 2
D- TYP WOOD WALL
1 1/2" = 1'-0"
3
E- TYP SWISS PEARL WALL
1 1/2" = 1'-0" 4
B- TYP FOUNDATION WITH STONE
1 1/2" = 1'-0" 5
A- TYP FOUNDATION WALL
No. Description Date
7 Revision 7 2016
1 1/2" = 1'-0" 8
1 HOUR INTERIOR WALL
1 1/2" = 1'-0"
9
1 HOUR FLOOR ASSEMBLY
1 1/2" = 1'-0" 6
F- TYP STEEL PANEL WALL
1 1/2" = 1'-0"
7
G- TYP STUCCO SITE WALL
1 1/2" = 1'-0" 10
H- TYP STONE SITE WALL
7
08/04/16