Loading...
HomeMy WebLinkAboutB15-0041_A607 WINDO_1470342600.pdfP2015_S P2015_S P2015_S P2015_S P2015_SP2007_SP2007_SP2007_SP2007_S P2007_S (WRB/AB) DELTA VENT S, LAP O/ FLASHING SHEATHING PER STRUCTURAL COVE BEAD & DOW 790 SEALANT DRYWALL RETURN @ JAMBS 1-3/4" LVL BUCK (PER STRUCT.) TO SUPPORT WINDOW IN CANT. POSITION, MOVE UP ABOVE SHADE POCKET 5/8" GWB LEVEL 4 FINISH 2X WALL & HEADER PER STRUCTURAL SHIM SPACE (SEE KEY); USE LOW EXPANSION SPF (DOW GREAT STUFF) B/W SHIMS 2" HUNTER Zci NAILBASE INSULATION 1X CEDAR VERTICAL BATTENS, COVER W/ EPDM WOOD SIDING PER ARCH SPEC/ APPROVED SAMPLE (SEE TYP. WALL DETAILS) DOW 758 SEALANT CONT. AT JAMBS & HEAD LUTRON ROLLER SHADE 64 (VERIFY SIZE) BLOCKING AS REQD. 2X CEDAR TRIM ALL SIDES, MATCH SIDING TYP. METAL FLASHING W/ HEMMED DRIP EDGE; 5/16" GAP B/W SIDING & SMF TO ALLOW FOR VENTILATION GWB VALLANCE BROMBAL STEEL LIFT/ SLIDE DOOR PROVIDE FLOOR RECESS FOR SETTING BED; NON SHRINK GROUT PER MANUF. SPEC; FIELD COORD. WEEPING SYST. W/ STRUCTURE EXTERIOR FINISH FLOOR & TOPPING SLAB; SLOPE 1/8" PER FT. MIN. TO DRAINS PROVIDE CONTINUOUS BACK DAM BLOCKING FULL WIDTH OF R.O. (COORD. HT. W/ INSTALLER) FINISH FLOOR O/ TOPPING SLAB W/ HEAT TUBING 1/2" DRAINAGE MAT O/ 1/8" PROTECTION BOARD O/ AH 6125 FR WPM SLEEPERS O/ STRUCTURAL FRAMING; SLOPE 1/8" PER FT. MIN. CONTINUE EXTERIOR PAVING INTO THRESHOLD AT WOOD FLOORS, TYP. 0' - 2" EXTEND AH 6125 ONTO SILL & BACKDAM PLYWOOD DECKING & FRAMING PER STRUCTURAL; EXTEND PLY. UNDER DOOR OPENING 0' - 1 3/4" 0' - 0 5/8" 0' - 1 3/4" VERTICAL BATTENS WRAPPED IN EPDM O/ DELTA VENT S WRB 2" NAILBASE INSULATION SHEATHING RE: STRUCTURAL WOOD SIDING PER ARCH SPEC 2X WALL (PER STRUCT.) W/ 1-1/2" MIN. SPF INSULATION @ SHEATHING FILL REMAINDER OF WALL W/ BIBS INSULATION COVE BEAD & DOW 790 SEALANT 3/8" SHIM SPACE & FASTENING STRAP (PER BROMBAL); USE LOW EXPANSION SPF (DOW GREAT STUFF) B/W SHIMS DOW 758 SEALANT CONT. AROUND PERIMETER OF WINDOW, TYP. 1-3/4" LVL BUCK (PER STRUCT.) TO SUPPORT WINDOW IN CANT. POSITION DRYWALL RETURN @ TOP & SIDES DELTA WINDOW FLASHING PER MANUF. REQUIREMENTS BROMBAL SHIM SPACE KEY- ALL WINDOWS: 3/8" AT ALL FOUR SIDES ALL SWING & PIVOT DOORS: 3/8" AT ALL THREE SIDES (NONE AT SILL) ALL LIFT/SLIDE DOORS: 1/2" AT ALL THREE SIDES (NONE AT SILL) 12" MIN. 6" JAMB EXTEND WRB 6" ONTO JAMB R.O., BOTH SIDES OF DOOR EXTEND WPM 12" MIN. ONTO EXT. WALL SHEATHING, BOTH SIDES OF DOOR WPM ON DECK EXT. PLY. 2-SIDED "PAN FLASHING" TYP. ALL EXT. DOOR THRESHOLDS CREATED OUT OF AH-6125 FR WPM -DRAWING NTS T.O. PLY OR SLAB CONT. WOOD BLOCKING BACKDAM; EXTEND FULL WIDTH OF R.O. EXTEND WPM ONTO SILL & BACKDAM Project number Date Drawn by 4/18/2016 11:20:51 AM A607 WINDOW DETAILS (MASTER) 103ROCK VAIL, CO 103 ROCKLEDGE ROAD 041816 LJF No. Description Date 3" = 1'-0" 1 BROMBAL- EBE LIFT/SLIDE HEAD & SILL_MASTER 3" = 1'-0" 2 BROMBAL- EBE LIFT/SLIDE JAMB_MASTER 08/04/16