HomeMy WebLinkAboutB15-0041_A607 WINDO_1470342600.pdfP2015_S
P2015_S
P2015_S
P2015_S
P2015_SP2007_SP2007_SP2007_SP2007_S
P2007_S
(WRB/AB) DELTA VENT S, LAP O/ FLASHING
SHEATHING PER STRUCTURAL
COVE BEAD & DOW 790 SEALANT
DRYWALL RETURN @ JAMBS
1-3/4" LVL BUCK (PER STRUCT.) TO
SUPPORT WINDOW IN CANT. POSITION,
MOVE UP ABOVE SHADE POCKET
5/8" GWB LEVEL 4 FINISH
2X WALL & HEADER PER STRUCTURAL
SHIM SPACE (SEE KEY); USE LOW EXPANSION
SPF (DOW GREAT STUFF) B/W SHIMS
2" HUNTER Zci NAILBASE INSULATION
1X CEDAR VERTICAL BATTENS, COVER W/ EPDM
WOOD SIDING PER ARCH SPEC/ APPROVED SAMPLE
(SEE TYP. WALL DETAILS)
DOW 758 SEALANT CONT. AT JAMBS &
HEAD
LUTRON ROLLER SHADE 64 (VERIFY SIZE)
BLOCKING AS REQD.
2X CEDAR TRIM ALL SIDES, MATCH SIDING TYP.
METAL FLASHING W/ HEMMED DRIP EDGE; 5/16" GAP
B/W SIDING & SMF TO ALLOW FOR VENTILATION
GWB VALLANCE
BROMBAL STEEL LIFT/ SLIDE DOOR
PROVIDE FLOOR RECESS FOR SETTING
BED; NON SHRINK GROUT PER MANUF.
SPEC; FIELD COORD. WEEPING SYST. W/
STRUCTURE
EXTERIOR FINISH FLOOR & TOPPING
SLAB; SLOPE 1/8" PER FT. MIN. TO
DRAINS
PROVIDE CONTINUOUS BACK DAM
BLOCKING FULL WIDTH OF R.O. (COORD.
HT. W/ INSTALLER)
FINISH FLOOR O/ TOPPING SLAB W/ HEAT
TUBING
1/2" DRAINAGE MAT O/ 1/8" PROTECTION
BOARD O/ AH 6125 FR WPM
SLEEPERS O/ STRUCTURAL FRAMING;
SLOPE 1/8" PER FT. MIN.
CONTINUE EXTERIOR PAVING INTO
THRESHOLD AT WOOD FLOORS, TYP.
0' - 2"
EXTEND AH 6125 ONTO SILL &
BACKDAM
PLYWOOD DECKING & FRAMING PER
STRUCTURAL; EXTEND PLY. UNDER DOOR
OPENING
0' - 1 3/4" 0' - 0 5/8"
0' - 1 3/4"
VERTICAL BATTENS WRAPPED IN EPDM O/
DELTA VENT S WRB
2" NAILBASE INSULATION
SHEATHING RE: STRUCTURAL
WOOD SIDING PER ARCH SPEC
2X WALL (PER STRUCT.) W/ 1-1/2" MIN.
SPF INSULATION @ SHEATHING
FILL REMAINDER OF WALL W/ BIBS
INSULATION
COVE BEAD & DOW 790 SEALANT
3/8" SHIM SPACE & FASTENING STRAP (PER
BROMBAL); USE LOW EXPANSION SPF (DOW
GREAT STUFF) B/W SHIMS
DOW 758 SEALANT CONT. AROUND
PERIMETER OF WINDOW, TYP.
1-3/4" LVL BUCK (PER STRUCT.) TO
SUPPORT WINDOW IN CANT. POSITION
DRYWALL RETURN @ TOP & SIDES
DELTA WINDOW FLASHING PER MANUF.
REQUIREMENTS
BROMBAL SHIM SPACE KEY-
ALL WINDOWS:
3/8" AT ALL FOUR SIDES
ALL SWING & PIVOT DOORS:
3/8" AT ALL THREE SIDES
(NONE AT SILL)
ALL LIFT/SLIDE DOORS:
1/2" AT ALL THREE SIDES
(NONE AT SILL)
12" MIN.
6"
JAMB
EXTEND WRB 6" ONTO JAMB
R.O., BOTH SIDES OF DOOR
EXTEND WPM 12" MIN. ONTO
EXT. WALL SHEATHING, BOTH
SIDES OF DOOR
WPM ON DECK
EXT. PLY.
2-SIDED "PAN FLASHING"
TYP. ALL EXT. DOOR THRESHOLDS
CREATED OUT OF AH-6125 FR WPM
-DRAWING NTS
T.O. PLY OR SLAB
CONT. WOOD BLOCKING
BACKDAM; EXTEND FULL
WIDTH OF R.O.
EXTEND WPM ONTO SILL
& BACKDAM
Project number
Date
Drawn by 4/18/2016
11:20:51 AM
A607
WINDOW DETAILS (MASTER)
103ROCK
VAIL, CO
103 ROCKLEDGE
ROAD
041816
LJF
No. Description Date
3" = 1'-0"
1
BROMBAL- EBE LIFT/SLIDE HEAD &
SILL_MASTER
3" = 1'-0"
2
BROMBAL- EBE LIFT/SLIDE
JAMB_MASTER
08/04/16