HomeMy WebLinkAboutB15-0068_stallion electrical load calcs_1429050540.pdf Tim Barany
From: Nick Lunn <nicklunncec@yahoo.com>
Sent: Friday, March 27, 2015 1:43 PM
To: Tim Barany
Subject: Load calc for service at 355 forest road
Optional Residential Load Calculation Results:
Multifamily Dwelling:
Dwelling Units:
Demand Factor: 100%
Step 1: General Lighting and Recepticles:
Total General Load @ 3VA: 18300 VA
Step I Total: 18300 VA
Step 2: AC System:
220.82(C)1 Total: 1500
220.82(C)2 Total: 0
220.82(C)3 Total: 0
220.82(C)4 Total: 3120
220.82(C)5 Total: 0
220.82(C)6 Total: 2400
Largest Load Per 220.82(C)
Step 2 Total: 3120 VA
Step 3: Fixed in Place Appliances:
Step 3 Total: 6200VA
Step 4: Dryers:
Step 4 Total: 3500 kW
Step 5: Cooking Appliances:
Step 5 Total: 7000 kW
General Load:
First 10k @ 100%: 10000
Remainder over 10k @ 40%: 10000
Total General Load: 20000
Final Totals:
Feeder Load: 23120 VA
Feeder Amperage: 96.333333333333 Amps
Neutral Load: 31 850 VA
Neutral Amperage: 132.70833333333 Amps
Service Size:
1
100 Amps
Conductor Size:
Feeders per Table 310.15(B)7:
Copper: 4 AWG
Aluminum: 2 AWG
Neutral per Table 310.15(B)7:
Copper: 4 AWG
Aluminum: 2 AWG
Ground per Table 250.66:
Copper: 8 AWG
Aluminum: 6 AWG
It is highly recommended to double check the calculations before submitting them on any professional level.
This calculation was generated with the ReiWare, LLC Service Load Calculation Tool Available on the Apple
App Store, Google Play and Amazon App Store.
Sent from my iPhone