HomeMy WebLinkAboutB15-0072_A1_1431966900.pdf il
I
05/1 8/1 5
i ..
. . ti .
,�-
a 1111 11 )
...g
___ 1 a 6 Kitchen Area- i��
Remove and eliminate existing Final Layout TBD a –
I- - - -1- � - � i bathroom/ powder room do allow /— I
�E . I for completely remodeled larger1 liffillit
LP 'S.�_ u IL:-�y
i CIP
El El 1 p y g 6" round a ® R _ _ _
I kitchen area with new finishes, corners �
1- U cabinets, fixtures and - - - - - T - - - -(/ �
Remove hallway walls and appliances �� —
doors (non structural) for _ _ _ _ _ U ' ' /
more open living room area – 42" tall wall ►
Bench/ Cubbies
4 1
Must come from thea
Arched airl
same stack as the 1 , Opening
11 I EN 1
� o � .. � _ = al loi
o � � � eliminated bathroom \ / ( , /i li GI
0
_ _CID_ _ 1 j -_,
7 . - ("6" - \ / t
r-i-:\ / \ ,
4
l 9 nil rii. p _ 11 , 1 ____—,
V _ I I
r„. 11 ,
a \ a0 „ O (I)
Remove existingbathroom I /
finishes and fixtures, adjustI 1IC\1 7
plumbing and framing for 1r a' a
new layout as needed 6" round
1 Hil , .,
Cr) %me
6" round corner
corners C, a a a
b
Bedroom #1
.,_. _. _ a 0 , , CIO (I)
Master Bedroom a a a
. , C 1:
,i is 1 D Ui - L—
• —
0
30' 30' (1) ■
■ Si
Li
Original/ Existing Floor Plan Proposed Floor Plan (I)
Scale- 1 /4 " = 1 ' Scale- 1 /4rr =- 1r —C A--0
0 C
CODE INFORMATION
General Notes
LL N.711 CON5TRUCTION Tt COMPLY' .111TH, TI -F 5I5rAN1 r RekT11465 PPR- TABLF CCI- No leioR. 15 FR P 71:3' T TI-17 E 1571NE
.2012 Irt6rnaticl'1ciI O II1Ilnig Lode PRIMARY 57RU TUBAL 1 ; 0 HR PRIOR 1 ALL5 OR 1007 1 - Complete interior remodel of existing unit including
.2012 Intarnational Plurnbin Cade TRI EEARII V ALL5; 2 SII all new finishes new cabinetry, and new fixtures
.2o1.2 I ritsr tr n l I harti1�l 6innie EXTERIOR HOl l-ISEARi H if qALLS: 0 1--I E., IITINIS. FIRE SPR I tKLE# S~r'STEh'i AND Drawn B
20i2 Ir7ttr ltr.r1c I Fuel Lade I1�LTER.I BEARING. PARTITIONS: I -HR. FIRE ALARM SYSTEM TO BEY--lAIhl- MAKE 2- Modify framing/ wall locations for new proposed By-
.2012 Inter ne:1 o'10I rine- Code- I ITMR.I01R 140N-BLARINS PARTITIONS: 0 1 1 1rI , TION5 A5 OL.1110 layout, no structrual changes all changes are to W MK
2 012 Irrterrohicra l Er criqy C...nriservint.lan C•ade 11-
2011 1 tr of 1.e.z.tele.,41 nde ROOF: I I PRoFOS D PLU IN rl...-T..$2.E ccArr, partition walls
Tonin 0.F Vial CrcIrnanc.a ria_ I2r ser-Iear ar 201.2.: 140 C-HAl 3- 6" round outside corners where porssible Date-
inclopthq updated Lades and arrlenelrronta FIRE R_ESISTA C.E RATING P1ALLS BETI IEE11 4- New lighting layout as shown above, At least 75% 3-27-15
IDI ELLI11S UNITS SHALL BE I HOUR PER I 706 ALL 1 IE PLUMB FI 7 ES, ETC. SHALL g 9 Y
TIJFEC CONSTI UCTIOINt III- I Tr �L I T iE I I� L ., CU1 1 ANT t5 A5 of new lighting to be high efficiency, any recessed can R1 4-23-15
oc.cUfa 1 Y I IFI TI - PROTECTION 07 THE P`R I1 ( 5TRUi AL FI Ah 1 ADOFTEI:" UtzTHE T 1 F : 'AlL lights are to receive tent/ hat to maintain fire ratings
ALICNABLE AREA.: .24rICC SI-/FLf (BEFORE 1ULT11 LIERS) TAY' EE # EOL EII BY I HnUR IF TI-1-7 u 1 i_ni 1 Nits Is
1'I .oP E) ATEA. N.ci cHAN5E Tc' I51-IiiI PROTECTED' 1 llTfi AN AUTOMATIC., S1 IN LEISYSTEM. 5- Plumbing to be modifed for new layot, any
ALLO BLE HT PER TTE~LE 505! 4 STORIES ( ISTIN5= penetrations to maintain required fire ratings
PROPOSED 1-11- NO Gi-AAN E Ti E IETINS 1,PEI. TABLE 602 OF T1 2CI- 1E6.. THE FIS
RESISTANCE NON 1E3F 1 TNI E RI 6- Mechanical- Existing heating sytem to reamin new
TSE EHI5TIN6 DUILt IN 5 AI.I. AF R Ir LL_S IS 0 H II lr THE SEPARATION exhaust fans for bathroom and kitchen hood
AUTOMATIC. FIRE SPRINKLER SYSTEM INSTALLED DISTANCE IS 0'
7- Verify carbon monoxide detector installed
8- Asbestos testing required
9- Verify all elec/ mech meets current code