Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B15-0097_A2.1_1430947980.pdf
DN DN DN UP DN UP UP DN COVERED PATIO End of existing wall A3.1 1 EXISTING GARAGE NEW ENTRY CARPORT 8415' - 1" EXISTING KITCHEN EXISTING LIVING ROOM EXISTING DINING ROOM 8421' - 5" 8420' - 10" 8415' - 9" EXISTING MASTER BEDROOM EXISTING MASTER BATH EAST UNIT WEST UNIT A3.3 2 A3.3 4 A3.3 3 8420' - 10" 8419' - 4 1/4" 8419' - 4 1/4" AR-1 8 ADDITION OR INFILL AREA WOOD DECK EXISTING WOOD DECK EXISTING TREEL HOLE TO REMAIN 8421' - 5" A3.2 1 8419' - 5" MOVE EXISTING WALL TO EXISTING STRUCTURAL COLUMN MOVE EXISTING WALL TO EXISTING STRUCTURAL COLUMN EXISTING STRUCTURAL COLUMN EXISTING STEPS 8415' - 1" 8415' - 1" NEW MUD ROOM 3' - 6" 1' - 4" 24' - 0" 24' - 0" 7' - 0" 14' - 6" 7' - 0" 10' - 3 3/4" 19' - 0" 1' - 9" 2' - 4" 9" 22' - 6" 9" 2' - 4" 1' - 9" 1/2 wall 4' - 0" 12' - 10" 15' - 10 1/2" 15' - 5 3/4" 6' - 7" 7' - 9" 11" 3' - 0" 9' - 2" NEW RAILING TO MATCH OTHERS AND TO MEET CODE 2' - 10" 2' - 10" REMOVE EXISTING STONE ON THIS WALL BOTH SIDES AND REPLACE WITH PANELS REMOVE EXISTING DIAGONAL SIDING ON THIS WALL AND REPLACE WITH HORIZONTAL SIDING TO MATCH EXISTING 3" POSSIBLY REMOVE EXISTING WINDOWS, VERIFY WITH OWNER PRIOR TO REMOVING CEILING TO BE 5/8" TYPE X DRYWALL, TYP IN GARAGE 3' X 7' 20 MIN DOOR PER CODE W CLOSER, CENTER DOOR ON 4' WIDE STAIRS, CENTER ON STAIRS 8416' - 3" 8416' - 3" 8X8 WOOD TIMBER ON 4' DEEP SONOTUBE CONCRETE PIER 3'X7' EXT DOOR 8'X8' INSULATED CARRIAGE STYLE GARAGE DOOR, TYP (2) NEW GARAGE MOVE PLUMBING FOR EXISTING SINK IF NEEDED TO THIS LOCATION 4' - 0" LINE WALL UP WITH EDGE OF STAIRS AS LONG AS THIS DIMENSION IS MIN 2' 2' - 2 3/4" EXISTING REFRIG 3' - 9" 2' - 0" 10' - 0" ASPHALT 7' - 2 1/2" 11' - 3" 7' - 6 1/2" 56 57 74 32 28 68 39 65 26 75 66 69 30 47 48 24 22 13 14 49 50 9 100 107 106 45 102 100 10 1 A4.0 1 A4.2 2 A4.1 2 A4.0 2 A4.2 1' - 6" 6' - 4 1/4" 5' - 10 1/4" 5' - 10 1/4" REMOVE AND REPLACE GARAGE DOOR WITH AN 8'X8' INSULATED CARRIAGE STYLE NEW POWDER ROOM 1 A4.1 20 EQ EQ 21 SEPARATION WALLS TO GARAGE ARE 5/8" TYPE X DRYWALL BOTH SIDES NO WORK TO EXISTING DEMISING WALL BETWEEN DUPLEX SIDES 1/4" = 1'-0" 1 GARAGE / ENTRY / MAIN LEVELS Project number Date REVISIONS Consultants: Structural Engineering: Monroe & Newell Engineers, Inc. Peter Monroe (p) 303.623.4927 (f) 970.949.4054 avon@monroe-newell.com Evans Chaffee Construction Group, Inc.Chris Evans (p)970.845.0466 (f) 970.845.0465 (e)cevans@evanschaffee.com Eagle Valley Surverying, Inc.(p)970.949.1405 General Contractor: Surveyor: 4/9/2015 11:15:27 PM A2.1 GARAGE / ENTRY / MAIN 1404 Residence Renovation PERMIT SET APRIL 7, 2015 Chris & Michele Evans 4126 Columbine Dr. Vail, CO Lot 16, Bighorn Subdivision NORTH No. Description Date 05/06/15