Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B15-0097_A5.0_1430947980.pdf
Project number Date REVISIONS Consultants: Structural Engineering: Monroe & Newell Engineers, Inc. Peter Monroe (p) 303.623.4927 (f) 970.949.4054 avon@monroe-newell.com Evans Chaffee Construction Group, Inc.Chris Evans (p)970.845.0466 (f) 970.845.0465 (e)cevans@evanschaffee.com Eagle Valley Surverying, Inc.(p)970.949.1405 General Contractor: Surveyor: 4/22/2015 1:13:43 PM A5.0 SCHEDULES 1404 Residence Renovation PERMIT SET APRIL 7, 2015 Chris & Michele Evans 4126 Columbine Dr. Vail, CO Lot 16, Bighorn Subdivision No. Description Date 1 Bldg Depart Req'd Rev 04.21.15 Door Schedule Mark Fire Rating Location/Size/Comments 10 Non Rated Front Door - 42" x 8' 20 Non Rated Dining Room Slider - see window order for Specifics 21 Non Rated Electrical Panel Door 36" x 7' Flush Door 34 Non Rated Game Room Slider - see window order for Specifics 45 Non Rated Master Bedrm Door - see window order for Specifics 100 Non Rated Garage Insulated Garage Door 8' x 8' 100 Non Rated Garage Insulated Garage Door 8' x 8' 100 Non Rated Garage Insulated Garage Door 8' x 8' 102 Non Rated Garage Mandoor to Carport 3' x 7' Insulated 106 20 Min Rated Garage Door to Mud Room 3' x 7' Flush Door (w closer) 107 Non Rated Powder Room Door Pocket Door 30" x 7' Flush Door 109 Non Rated Loft Closet Door 30" x 7' Flush Door 110 Non Rated Loft Bedroom Door 30" x 7' Flush Door 111 Non Rated Loft Bedrm Closet Dr 30" x 7' Flush Door 112 Non Rated Loft Bathroom Dr 30" x 7' Flush Door 113 Non Rated Loft Water Closet Door 24" x 7' Flush Door 114 Non Rated Shower Door 24" x 7' Glass INSULATION Insulation is to be spray foam with aged R-value of 5.8 per inch All New Interior Walls: R-13 or R-19 sound batts All New Mid Floors: R-30 batt insulation All New Exterior Walls: R-32 closed cell foam insulation All New Roofs: R-70 closed cell foam insulation Interior of New Fdn walls: R-10 2" rigid insulation Bevel top edge at 45 deg below slab height WINDOW NOTES All Exterior Windows/ Doors to be Replaced on unit 4126A Window & Sliding Door U Value less than 0.32 Skylights: S1-S7 30" x 45" Velux Roof Mounted Skylight U Value less than 0.5 Window Schedule Mark RO - New or Replace Existing - Location - Uvalue - Tempered or Egress 45 Part of Item 37 - Inwing Door - Replace Existing - Master Bedroom - UValue = 0.29, TEMPERED 46 MULL LAYOUT 47 60 3/4" x 60 3/4" - Replace Existing - Master Bathroom - UValue = 0.27, TEMPERED 48 Part of Item 47 - Replace Existing - Master Bathroom - Uvalue = 0.30, TEMPERED, AWNING 49 28 3/4" x 24 3/4" - New - Garage - UValue = 0.30 50 28 3/4" x 24 3/4" - New - Garage - UValue = 0.30 51 56 3/4" x 18 3/4" - New - Loft Bathroom - UValue = 0.30 52 63 3/4" x 33 3/4" - Replace Existing - Kitchen - UValue = 0.27 53 Part of item 52 - Replace Existing - Kitchen - UValue = 0.29, CASEMENT 54 63 3/4" x 33 3/4" - Replace Existing - Lower Bath - UValue = 0.27, TEMPERED 55 Part of item 54 - Replace Existing - Lower Bath - UValue = 0.29, TEMPERED, CASEMENT 56 23 3/4" x 23 3/4" - Replace Existing - Master Bathroom - UValue = 0.30 57 23 3/4" x 23 3/4" - Replace Existing - Master Bathroom - UValue = 0.30 58 66 3/4" x 45 3/4" - Replace Existing - Upper Lvl Bedroom - UValue = 0.27 59 Part of item 52 - Replace Existing - Upper Lvl Bedroom - UValue = 0.29, CASEMENT, EGRESS 60 56 3/4" x 24 3/4" - New - Loft over Study - UValue = 0.30 61 28 3/4" x 41 3/4" - Replace Existing - Study - UValue = 0.30 62-63 Custom Trap 87 1/4" x 192" - Replace Existing - Master Bedroom - UValue = 0.26 65 Part of Item 62 - Replace Existing - Master Bedroom - UValue = 0.26 66 Part of Item 62 - Replace Existing - Master Bedroom - UValue = 0.26, TEMPERED 68 Part of Item 62 - Replace Existing - Master Bedroom - UValue = 0.30, TEMPERED, AWNING 69 Part of Item 62 - Replace Existing - Master Bedroom - UValue = 0.26, TEMPERED 71-72 Custom Trap 121 1/2" x 149 7/8" - New - Dining Room - UValue = 0.26 (#72 is TEMPERED) 74 Part of Item 71 - New - Dining Room - UValue = 0.26, TEMPERED 75 Part of Item 71 - New - Dining Room - UValue = 0.26, TEMPERED 76 MULL LAYOUT 80 24 3/4" x 60 3/4" - New - 4126B Stairwell - UValue = 0.29 80 24 3/4" x 60 3/4" - New - 4126B Stairwell - UValue = 0.29 80 24 3/4" x 60 3/4" - New - 4126B Stairwell - UValue = 0.29 S1 30" x 45" - Replace Existing - Velux Skylight - UValue less than 0.50 S2 30" x 45" - Replace Existing - Velux Skylight - UValue less than 0.50 S3 30" x 45" - Replace Existing - Velux Skylight - UValue less than 0.50 S4 30" x 45" - Replace Existing - Velux Skylight - UValue less than 0.50 S5 30" x 45" - Replace Existing - Velux Skylight - UValue less than 0.50 S6 30" x 45" - Replace Existing - Velux Skylight - UValue less than 0.50 S7 30" x 45" - Replace Existing - Velux Skylight - UValue less than 0.50 Window Schedule Mark RO - New or Replace Existing - Location - Uvalue - Tempered or Egress 1 70 3/4" x 126 3/4" - New - Entry Loft - Uvalue = 0.26 2 Part of Item 1 - New - Entry Loft - Uvalue = 0.26 3 VERT INTERLOCK 4 Part of Item 1 - New - Entry Loft - Uvalue = 0.26 5 Part of Item 1 - New - Entry Loft - Uvalue = 0.26 6 VERT FRAME 7 Part of Item 1 - New - Entry Loft - Uvalue = 0.26 8 MULL LAYOUT 9 28 1/4" x 96 3/4" - Entry - Uvalue = 0.26, TEMPERED 10 ENTRY FRAME 11 56 3/4" x 60 3/4" - New - Loft Sitting Room - Uvalue = 0.29, CASEMENT 12 84 3/4" x 60 3/4" - New - Loft Bedroom - Uvalue = 0.29, CASEMENT, EGRESS 13 56 3/4" x 28 3/4" - New - Mudroom - Uvalue = 0.30, AWNING 14 28 3/4" x 28 3/4" - New - Mudroom - Uvalue = 0.30, TEMPERED, AWNING 15 Part of Item 20 - New - Dining Room -Uvalue = 0.26 16 Part of Item 20 - New - Dining Room -Uvalue = 0.26 17 Part of Item 20 - New - Dining Room -Uvalue = 0.26 18 Part of Item 20 - New - Dining Room -Uvalue = 0.26 19 STEEL 20 159 15/16" x 114 3/4" - Siding Door Replace Existing - Dining Room - UValue = 0.29, TEMPERED 21 MULL LAYOUT 22 265 1/16" x 127 3/4" - Replace Existing - Living Room - UValue = 0.26 23 STEEL 24 Part of Item 22 - Replace Existing - Living Room - UValue = 0.26, TEMPERED, AWNING 25 STEEL 26 Part of Item 22 - Replace Existing - Living Room - UValue = 0.26, TEMPERED 28 Part of Item 22 - Replace Existing - Living Room - UValue = 0.26, TEMPERED 29 STEEL 30 Part of Item 22 - Replace Existing - Living Room - UValue = 0.26 31 STEEL 32 Part of Item 22 - Replace Existing - Living Room - UValue = 0.30, TEMPERED 33 MULL LAYOUT 34 155 15/16" x 84 3/4" - Siding Door Replace Existing - Rec Room - UValue = 0.29, TEMPERED 35 58 3/4" x 41 3/4" - Replace Existing - Lower Lvl Bedroom - UValue = 0.29, CASEMENT, EGRESS 36 58 3/4" x 41 3/4" - Replace Existing - Lower Lvl Bedroom - UValue = 0.29, CASEMENT 37 58 1/4" x 195 1/4" - Replace Existing - Master Bedroom - UValue = 0.29, TEMPERED 38 STEEL 39 Part of Item 37 - Replace Existing - Master Bedroom - UValue = 0.26, TEMPERED 41 Part of Item 37 - Replace Existing - Master Bedroom - UValue = 0.30, TEMPERED, AWNING 42 STEEL 43 Part of Item 37 - Replace Existing - Master Bedroom - UValue = 0.26, TEMPERED 05/06/15