DESCRIPTION
SYMBOL
ELECTRICAL - DATA - AUDIO LEGEND
Ceiling Fan
Ventilation Fans: Ceiling Mounted, Wall Mounted
Ceiling Mounted Light Fixtures: Surface/Pendant,
Recessed, Heat Lamp, Low Voltage
Wall Mounted Light Fixtures: Flush Mounted,
Wall Sconce
Chandelier Light Fixture
240V Receptacle
110V Receptacles: Duplex, Weather Proof, GFCI
Switches: Single Pole, Weather Proof, 3-Way, 4-Way
Switches: Dimmer, Timer
Audio Video: Control Panel, Switch
Wall Jacks: CAT5, CAT5 + TV, TV/Cable
Telephone Jack
Intercom
Thermostat
Door Chime, Door Bell Button
Smoke Detectors: Ceiling Mounted, Wall Mounted
Electrical Breaker Panel
Speakers: Ceiling Mounted, Wall Mounted
Fluorescent Light Fixture
ELECTRICAL SCHEDULE
NUMBER QTY DESCRIPTION
E01 10 48" LED TROFFER
E07 7 FOUR WAY
E08 3 DUPLEX (WEATHERPROOF)
E12 19 DUPLEX
E13 32 DUPLEX (DECORATOR)
E14 3 GFCI
E15 3 EXHAUST (LIGHT)
E16 11 SINGLE POLE
E17 52 RECESSED DOWN LIGHT 4
E18 2 CO/SMOKE DETECTOR
E19 12 THREE WAY
FIXTURE SCHEDULE
NUMBER DESCRIPTION QTY COMMENTS
A01 ELONGATED TOILET 2 KOHLER COMFORT HEIGHT WITH SOFT CLOSE LID. DUAL FLUSH
A03 POWDER ROOM SINK 1 SELECTED BY HOMEOWNER
A04 EXISTING SLOP SINK 1 RELOCATE AS NEEDED
A05 FROST-PROOF HOSE BIBB 1 PROVIDE HOT & COLD WATER SUPPLY
A06 OVAL 2 KOHLER CAXTON - WHITE
Existing Service is 200 Amp
MEP NOTES
ELECTRICAL:
RUN NEW CIRCUITS TO EXISTING PANEL IN NEW MUD ROOM
ALL ELECTRICAL TO BE IN ACCORDANCE WITH 2011 NEC.
VERIFY COMPATIBILITY OF NEW HARDWIRED CARBON
MONOXIDE/SMOKE DETECTORS TO WIRELESSLY INTERFACE
WITH EXISTING DETECTORS INSTALLED THROUGHOUT
REMAINDER OF HOUSE.
REPLACE ALL EXISTING BREAKERS IN MAIN PANEL WITH NEW
BREAKERS.
ALL NEW LIGHTING TO BE LED.
ALL RECEPTACLES TO BE TAMPER PROOF
PLUMBING:
PLUMBING SCOPE OF WORKS TO BE DESIGN/BUILD BY
PLUMBING SUBCONTRACTOR.
CONNECT ALL WATER LINES TO EXISTING HOT & COLD WATER
LINES
NEW DRAIN LINES TO BE CAST IRON - RUN PER CODE
WASTE LINES BELOW GROUND CAN BE ABS - RUN PER CODE
VENT LINES ABOVE GRADE CAN BE ABS - RUN PER CODE
PEX TUBING IS PREFERRED FOR ALL NEW WATER LINES.
REPAIR DAMAGE/DEFICIENCIES IN EXISTING SYSTEM UPON
NOTIFICATION TO AND APPROVAL FROM HOMEOWNER.
MECHANICAL:
MECHANICAL SCOPE OF WORK TO BE DESIGN/BUILD BY
MECHANICAL SUBCONTRACTOR.
EXTEND EXISTING FORCED AIR HEATING SYSTEM TO SERVE
THIS LEVEL
VENT BATHROOMS TO EXTERIOR PER CODE.
THERE ARE NO NEW GAS LOADS ASSOCIATED WITH THIS
SCOPE OF WORK.
REPAIR DAMAGE/DEFICIENCIES IN EXISTING SYSTEM UPON
NOTIFICATION TO AND APPROVAL FROM HOMEOWNER.