GFCI
GFCI
GFCI
3
266 sq ft
LIVING AREA
SWITCH TOP HALF
OF DUPLEX
CONNECT TO "UPPER BATH"
20 AMP GFCI CIRCUIT
CONNECT TO "BEDROOM"
20 AMP AFCI CIRCUIT
THIS ROOM AND CLOSET
CONNECT TO "SITTING AREA"
20 AMP CIRCUIT
CARBON MONOXIDE / SMOKE DETECTOR
HARDWIRE, TWO PLACES TYP.
USE WIRELESS INTERCONNECT TO
CONNECT TO OTHER EXISTING IN HOME.
VENT EXHAUST TO EXTERIOR
MEP NOTES
ELECTRICAL:
RUN NEW CIRCUITS TO EXISTING PANEL IN NEW MUD ROOM
ALL ELECTRICAL TO BE IN ACCORDANCE WITH 2011 NEC.
VERIFY COMPATIBILITY OF NEW HARDWIRED CARBON
MONOXIDE/SMOKE DETECTORS TO WIRELESSLY INTERFACE
WITH EXISTING DETECTORS INSTALLED THROUGHOUT
REMAINDER OF HOUSE.
REPLACE ALL EXISTING BREAKERS IN MAIN PANEL WITH NEW
BREAKERS.
ALL NEW LIGHTING TO BE LED.
ALL RECEPTACLES TO BE TAMPER PROOF
PLUMBING:
PLUMBING SCOPE OF WORKS TO BE DESIGN/BUILD BY
PLUMBING SUBCONTRACTOR.
CONNECT ALL WATER LINES TO EXISTING HOT & COLD WATER
LINES
NEW DRAIN LINES TO BE CAST IRON - RUN PER CODE
WASTE LINES BELOW GROUND CAN BE ABS - RUN PER CODE
VENT LINES ABOVE GRADE CAN BE ABS - RUN PER CODE
PEX TUBING IS PREFERRED FOR ALL NEW WATER LINES.
REPAIR DAMAGE/DEFICIENCIES IN EXISTING SYSTEM UPON
NOTIFICATION TO AND APPROVAL FROM HOMEOWNER.
MECHANICAL:
MECHANICAL SCOPE OF WORK TO BE DESIGN/BUILD BY
MECHANICAL SUBCONTRACTOR.
EXTEND EXISTING FORCED AIR HEATING SYSTEM TO SERVE
THIS LEVEL
VENT BATHROOMS TO EXTERIOR PER CODE.
THERE ARE NO NEW GAS LOADS ASSOCIATED WITH THIS
SCOPE OF WORK.
REPAIR DAMAGE/DEFICIENCIES IN EXISTING SYSTEM UPON
NOTIFICATION TO AND APPROVAL FROM HOMEOWNER.