HomeMy WebLinkAboutB15-0101_Load Calcs_1428948240.pdfLOAD CALCULATION PER N.E.C. EXAMPLE D1 ( a ) VAIL MT. HAUS UNIT 679 - 04/09/15 208-V / 1-PHASE SUPPLY GENERAL LOAD -LOAD IN VOLT-AMPS 936 SQ. FT. @ 3W/FT 2,808.00 SMALL APPLIANCE 3,000.00 LAUNDRY / APPLIANCES 1,500.00 TOTAL 7,308.00 3000VA @ 100%3,000.00 7,308VA - 3,000VA = 4,308VA @ 35%1,508.00 NET LOAD 4,508.00 RANGE - 1 @ 8 KVA EACH 8,000.00 MICROWAVE - 1 @ 1200 VA EACH 1,200.00 SUB ZERO - 1 @ 1200 VA EACH 1,200.00 DISHWASHER - 1 @ 1200 VA EACH 1,200.00 DISPOSAL - 1 @ 800 VA EACH 800.00 NET CALCULATED LOAD 16,908.00 MINIMUM FEEDER AMPS 81.29 SERVICE BUSSING / MAIN AMPACITY 90.00