Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B15-0148_A0.02 - PROPOSED PLAN_1432231020.pdf
GFI +42 GFI +42 GFI +42 GFI +42 X6 TV +60" 220 GFI 22' - 2" 15' - 0" 3' - 10 1/4" 5' - 6" 14' - 7 3/4" 3' - 10" 65' - 0" 3' - 10" 13' - 1" 3 1/2" 10' - 4" 27' - 10" 18' - 5 1/2" 8' - 4 1/2" 3' - 5" 3' - 8" 5' - 4" 5' - 8" 3' - 9 1/2" 11' - 9 1/2" 6' - 0" 10' - 2" 3' - 10" 7' - 10 1/2" 40' - 9 1/2" 4' - 6" 8' - 0" 3 1/2" 3' - 1" 2' - 4" 2' - 4" 3' - 1" 3 1/2" 3' - 0 1/2" 5' - 0 1/2" 8' - 0" EXISTING BALCONY EXISTING GAS FIREPLACE, TO BE REPLACED, EXISTING FIRE RATING TO BE MAINTAINED 4' - 2" 3' - 9" 4' - 0" 5' - 10 1/2" 2' - 0" 6' - 4 1/2" 2' - 4" 7' - 0 1/2" 7' - 8" 4' - 6" 32' - 8" 2' - 2 1/2" 3' - 5 1/4" 2' - 5 3/4" YOGA STUDIO 8 OFFICE 6 BATH 2 7 ALL PURPOSE ROOM 5 CLOSET 3 LAUNDRY 4 BEDROOM 1 A4.01 1 A4.02 1 A4.01 6 BATH 1 14 EXISTING EGRESSIBLE WINDOW TO REMAIN PLAN NORTH TRUE NORTH S JB JB JB JB JB JB JB JB CMD WP WP JB JB JB 3' - 6" JB JB JB JB JB S CMD T T T RECESSED FIXTURE (TYPE A) LINEAR SURFACE FLUORESCENT (TYPE D) RCP LEGEND SINGLE SWITCH D 3 DIMMER SWITCH 3-WAY SWITCH DJ DOOR JAMB SWITCH RECESSED DIRECTIONAL FIXTURE (TYPE B) JUNCTION BOX M MOTION SENSOR 4 LUTRON 6 SLOT SWITCH 6 LUTRON 4 SLOT SWITCH VENT FAN RECESSED - WATER PROOF (TYPE C) CHANDELIER (TYPE E) CMD CARBON MONOXIDE DETECTOR WP JB S SMOKE DETECTOR T THERMOSTAT EXISTING PROPOSED PLUMBING FIXTURES LAVATORY NOTE: PROPOSED CONSTRUCTION WILL RESULT IN A NET LOSS OF OVERALL PLUMBING FIXTURES. SINKS LAUNDRY TOILETS TUBS DISHWASHER SHOWER ICE MAKER FIXTURE TOTAL 2 3 0 1 1 1 2 2 1 2 0 1 1 0 0 1 7 11 NOTE: NET REDUCTION OF 4 PLUMBING FIXTURES -4 NET TOTAL NEW STUD WALLS EXISTING WALLS DEMOLITION LEGEND WALLS TO BE DEMOLISHED NONCOMBUSTIBLE PENETRATING ITEM FIRE RATED PENETRATIONS NONCOMBUSTIBLE SLEEVE FIRE RATED WALL ASSEMBLY FIRE RATED WALL NONCOMBUSTIBLE PENETRATING ITEM NONCOMBUSTIBLE SLEEVE FIRE RATED CONCRETE OR MASONRY WALL FIRE RATED CONCRETE WALL, FLOOR OR CEILING NONCOMBUSTIBLE PENETRATING ITEM NONCOMBUSTIBLE SLEEVE FIRE RATED FLOOR ASSEMBLY ASSEMBLY FIRE RATED FLOOR ASSEMBLY SECTION 714.1.1 UL 2158A SECTION 714.1.1 UL 2158A SECTION 714.1.1 UL 2158A PLAN VIEW PLAN VIEW PLAN VIEW 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 684 W LIONSHEAD CIR. UNIT 322 VAIL, CO 81657 A1.02 FLOOR PLAN AND RCP MONTANEROS CONDOS Project Number 1519 05/12/15 PERMIT SET 1/4" = 1'-0" 2 UNIT 322 - LEVEL 2 1/4" = 1'-0" 3 UNIT 322 - LEVEL 2 NOTE: EXISTING FIRE SPRINKLER SYSTEM WILL STAY ON-LINE DURING CONSTRUCTION. SPRINKLER HEADS TO BE RELOCATED AFTER FRAMING. EXISTING FIRE SPRINKLER PLAN T 05/21/15