Loading...
HomeMy WebLinkAboutB15-0151_B15-0151 Drill Report_1442331960.pdfClient: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper Vail Marriott - Mezzanine Beam Repair Mr. Bruce Collins Restruction Corporation 3870 S Platte Ave Sedalia, CO 80135 Comments or Photos: Yes No Discrepancies Reported this Date? No. of Pages Attached: Field Representative: Drill and Epoxy Cover Report Date:Date Job NameJob Number:Job Number As scheduled, a representative visited the project site to perform special inspections for drill and epoxy at locations requested. General Contractor:General Contractor Rep. Notified:Rep Notified August 19, 2015 15-6564 Restruction Corporation Dillon 1 Shane Sorensen Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper Vail Marriott - Mezzanine Beam Repair Mr. Bruce Collins Restruction Corporation 3870 S Platte Ave Sedalia, CO 80135 Location: 1.) 2.) 3.) 4.) Orientation (vertical/horizontal): 1.) 3.) 2.) 4.) Hole Diameter (inches): 1.) Length (inches): 1.) 2.) 2.) 3.) 3.) 4.) 4.) Hole Spacing (inches): 1.) 3.) 2.) 4.) Drilling Equipment: Method to Clean Hole: Epoxy Type: Epoxy Expiration: Placement Method: Type (rebar/bolt/anchor): 1.) Size: 1.) Length (inches) 1.) 2.) 2.) 2.) 3.) 3.) 3.) 4.) 4.) 4.) Placement Method: Additional Reinforcing Steel: Field Representative: Comments: Reinforcement Epoxy Documents Used: Drill and Epoxy Drilling Subcontractor: Rep. Notified: pGeneral Contractor: Rep. Notified: p Job Number:Report Date:August 19, 2015 15-6564 Restruction Corporation Shane N/A N/A Plan Sheet S1 Into footing for wedge anchors in lower column base plate Vertical 3/4 7 5 Hammer Drill Shop Vac N/A N/A N/A Red Head Wedge Anchor 3/4 10 Adjustable wrench N/A Shane Sorensen Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper Vail Marriott - Mezzanine Beam Repair Mr. Bruce Collins Restruction Corporation 3870 S Platte Ave Sedalia, CO 80135 Date: Location: Job Number: Yes No Outstanding Discrepancies Reported this Date? No. of Pages Attached: Field Representative: Structural Steel Cover Report As scheduled, a representative arrived to perform special inspection services. The following is a summary of services provided on this date. August 25, 2015 Site 15-6564 As directed by Dylan with Restruction Corporation, GROUND inspected the following: 1) Inspected fillet welded connections of added full height and partial height stiffeners to 2 existing wide flange beams, added HSS columns welded to the lower and upper existing wide flange beams. These connections are found in compliance with project plans and in general compliance with AWS D1.1-10 clause 6 table 6.1. 2) Received and reviewed Welder Qualification test Record (WQTR) and found it in accordance with ASME Section IX. Dylan was present during the inspections. Bruce and Dylan were copied on todays Report. 0 Josh Bash 15-6564.tubecolumn.150828.1.SS Page 1 of 1 Date: Test Number: Protection / Weather: Product & Manufacturer (cubic cm) (grams) (pcf) (pcf) min. 1.) 1.)(inches) 2.) 2.)(sq. ft.) 3.) 3.)(lbs) 4.) 4.) (psf) (psf) Average Thickness (inches) Notification:Installer / General (contractor / name) Specified Min Thickness (in) Individual Measurement PASS Average Field Representative: Notes: PASS Monokote MK-6 Fireproofing material completely filled the space between the column and the CMU wall, which we could not measure. (reported as 1 10/16) PASS PASS 09/02/15Date: Shane Sorensen Diameter of specimen: 140 16.75 Area of specimen: Recorded failure force: New support column first level Cohesive 17.8 Adhesion 290.7 3 1/4 0.0576 Location: 39.9 15Specified Density Density of sample ADHESION DETERMINATION Location of failure: 1 14/16 1 14/16 1 14/16 Specified Adhesion 200 1 14/16 1 14/16 1 10/16 1 10/16 1 10/16 1 13/16 FIREPROOFING - TUBE COLUMNS Location: DENSITY DETERMINATION Location: 8/27/15 Visual Observations / Discrepancies: Area Represented: 1 70s Project: Job Number: Mr. Bruce CollinsAttn: August 28, 2015 15-6564 Aspen Insulation (N/A) / Restruction (Dillon) Sedalia, CO 80135 3870 S Platte Ave Recorded Measurement (inches) Air Temperature (ºF):Dates Applied: THICKNESS DETERMINATION 1 14/16 Volume of test sample Restruction Corportation Vail Marriott - Mezzanine Beam Repair Client: Dry weight of sample None (interior) New support column on first level None New support column first level New support column first level 1 2 3 42 1 4 3 AT EACH END OF 4 MEASUREMENTS 12-INCH LENGTH 41 Inverness Dr East Englewood, CO 80112 Tel:(303)289 1989 Fax:(303)289 1686 Offices: Denver, Loveland, Gypsum, Grand Junction, Granby, Casper WY 7393 Dahlia Street Commerce City, CO 80022 Tel:(303)289 1989 Fax:(303)289 6742 15-6564.tubecolumn.150828.2.SS Page 1 of 1 Date: Test Number: Protection / Weather: Product & Manufacturer (cubic cm) (grams) (pcf) (pcf) min. 1.) 1.)(inches) 2.) 2.)(sq. ft.) 3.) 3.)(lbs) 4.) 4.) (psf) (psf) Average Thickness (inches) Notification:Installer / General (contractor / name) Specified Min Thickness (in) Individual Measurement PASS Average Field Representative: Notes: Volume of test sample Restruction Corportation Vail Marriott - Mezzanine Beam Repair Client: Aspen Insulation (N/A) / Restruction (Dillon) Sedalia, CO 80135 3870 S Platte Ave Recorded Measurement (inches) Air Temperature (ºF):Dates Applied: THICKNESS DETERMINATION FIREPROOFING - TUBE COLUMNS Location: DENSITY DETERMINATION Location: 8/27/15 Visual Observations / Discrepancies: Area Represented: 2 70s Project: Job Number: Mr. Bruce CollinsAttn: August 28, 2015 15-6564 1 12/16 1 13/16 1 11/16 1 11/16 1 11/16 1 11/16 Dry weight of sample Location of failure: 1 12/16 1 12/16 1 15/16 45.4 15Specified Density Density of sample ADHESION DETERMINATION 1 12/16 None (interior) New support column on second level None Specified Adhesion 200 New support column second level New support column second level New support column second level Cohesive 19.5 Adhesion 273.4 3 1/4 0.0576 Location: PASS Monokote MK-6 Fireproofing material completely filled the space between the column and the CMU wall, which we could not measure. (reported as 1 11/16) PASS PASS 09/02/15Date: Shane Sorensen Diameter of specimen: 145 15.75 Area of specimen: Recorded failure force: 1 2 3 42 1 4 3 AT EACH END OF 4 MEASUREMENTS 12-INCH LENGTH 41 Inverness Dr East Englewood, CO 80112 Tel:(303)289 1989 Fax:(303)289 1686 Offices: Denver, Loveland, Gypsum, Grand Junction, Granby, Casper WY 7393 Dahlia Street Commerce City, CO 80022 Tel:(303)289 1989 Fax:(303)289 6742 15-6564.FPbeam.150828.1.SS Page 1 of 1 Date: Test Number: Protection / Weather: Product & Manufacturer FAIL (cubic cm) (grams) (pcf) (pcf) min. 1.) 1.) 2.) 2.) 3.) 3.) 4.) 4.) 5.) 5.)(inches) 6.) 6.)(sq. ft.) 7.) 7.)(lbs) 8.) 8.) 9.) 9.) (psf) (psf) Average Thickness (inches) Average Thickness (inches)Notification:Installer / General (contractor / name) Specified Min Thickness (in) Specified Min Thickness (in) Individual Measurement FAIL Average Field Representative: Notes: First level beam Location: Diameter of specimen: FAIL Monokote MK-6 Dillon with Restruction Corportation was notified of failing thickness tests and schedule Aspen Insulation to reapply fireproofing to the area. excluding flange tips Date: Shane Sorensen 1 6/16 flange tips only 1 6/16 1 6/16 1flange tips only 1 4/16 Specified Density Recorded failure force: Location of failure: Area of specimen: ADHESION DETERMINATION Adhesion Not tested at this time Specified Adhesion 1 5/16 1 7/16 1 10/16 1 6/16 1 4/16 1 7/16 1 4/16 1 6/16 70s 1 9/16 10/16 1 12/16 1 1/16 1 1 8/16 Recorded Measurement (inches) THICKNESS DETERMINATION Volume of test sample 1 10/16 1 10/16 Density of sample None (interior) First level beam None Project: Job Number: Mr. Bruce CollinsAttn: August 28, 2015 15-6564 Restruction Corporation Vail Marriott - Mezzanine Beam Repair FIREPROOFING - BEAMS Dry weight of sample Not Tested Client: Aspen Insulation (N/A) / Restruction (Dillon) Sedalia, CO 80135 3870 S Platte Ave 1 4/16 Dates Applied: Location: DENSITY DETERMINATION Location: 8/27/15 Visual Observations / Discrepancies: Area Represented: Air Temperature (ºF): 9 MEASUREMENTS 12-INCH LENGTHAT EACH END OF 5 46 73 28 91 41 Inverness Dr East Englewood, CO 80112 Tel:(303)289 1989 Fax:(303)289 1686 Offices: Denver, Loveland, Gypsum, Grand Junction, Granby, Casper WY 7393 Dahlia Street Commerce City, CO 80022 Tel:(303)289 1989 Fax:(303)289 6742 15-6564.FPbeam.150828.2.SS Page 1 of 1 Date: Test Number: Protection / Weather: Product & Manufacturer PASS (cubic cm) (grams) (pcf) (pcf) min. 1.) 1.) 2.) 2.) 3.) 3.) 4.) 4.) 5.) 5.)(inches) 6.) 6.)(sq. ft.) 7.) 7.)(lbs) 8.) 8.) 9.) 9.) (psf) (psf) Average Thickness (inches) Average Thickness (inches)Notification:Installer / General (contractor / name) Specified Min Thickness (in) Specified Min Thickness (in) Individual Measurement PASS Average Field Representative: Notes: Aspen Insulation (N/A) / Restruction (Dillon) Sedalia, CO 80135 3870 S Platte Ave 15/16 Dates Applied: Location: DENSITY DETERMINATION Location: 8/27/15 Visual Observations / Discrepancies: Area Represented: Air Temperature (ºF): Project: Job Number: Mr. Bruce CollinsAttn: August 28, 2015 15-6564 Restruction Corporation Vail Marriott - Mezzanine Beam Repair FIREPROOFING - BEAMS Client: 70s 1 3/16 1 2/16 1 3/16 1 1/16 1 2/16 2 1 Recorded Measurement (inches) THICKNESS DETERMINATION Volume of test sample 1 2/16 1 3/16 Density of sample 18.1 None (interior) Second level beam None Dry weight of sample 39.5 136 Specified Adhesion 1 3/16 1 1/16 1 3/16 1 2/16 1 1/16 1 1/16 15/16 1 2/16 Specified Density Recorded failure force: 17.5 Location of failure: Cohesive Second Level Beam Area of specimen: ADHESION DETERMINATION Adhesion 303.8 3.25 0.0576 200 Second level beam Second Level beam Location: Diameter of specimen: PASS Monokote MK-6 PASS PASS excluding flange tips 09/02/15Date: Shane Sorensen 15/16 flange tips only 15/16 1 2/16 1 1/16flange tips only 1 15 9 MEASUREMENTS 12-INCH LENGTHAT EACH END OF 5 46 73 28 91 41 Inverness Dr East Englewood, CO 80112 Tel:(303)289 1989 Fax:(303)289 1686 Offices: Denver, Loveland, Gypsum, Grand Junction, Granby, Casper WY 7393 Dahlia Street Commerce City, CO 80022 Tel:(303)289 1989 Fax:(303)289 6742 15-6564.FPbeam.150902.1.SS Page 1 of 1 Date: Test Number: Protection / Weather: Product & Manufacturer PASS (cubic cm) (grams) (pcf) (pcf) min. 1.) 1.) 2.) 2.) 3.) 3.) 4.) 4.) 5.) 5.)(inches) 6.) 6.)(sq. ft.) 7.) 7.)(lbs) 8.) 8.) 9.) 9.) (psf) (psf) Average Thickness (inches) Average Thickness (inches)Notification:Installer / General (contractor / name) Specified Min Thickness (in) Specified Min Thickness (in) Individual Measurement PASS Average Field Representative: Notes: 200 First level beam Fist Level beam Location: Diameter of specimen: PASS Monokote MK-6 First floor beam was retested after additional fireproofing material was applied. PASS PASS excluding flange tips 09/02/15Date: Shane Sorensen 1 6/16 flange tips only 1 6/16 1 9/16 1 7/16flange tips only 1 10/16 15Specified Density Recorded failure force: 18.25 Location of failure: Cohesive First Level Beam Area of specimen: ADHESION DETERMINATION Adhesion 316.8 3.25 0.0576 Specified Adhesion 1 10/16 1 8/16 1 9/16 1 7/16 1 7/16 1 7/16 1 7/16 1 10/16 70s 1 10/16 1 7/16 1 10/16 1 7/16 1 8/16 1.1 (Retest) 1 8/16 Recorded Measurement (inches) THICKNESS DETERMINATION Volume of test sample 1 7/16 1 9/16 Density of sample 18.3 None (interior) First level beam None Project: Job Number: Mr. Bruce CollinsAttn: September 2, 2015 15-6564 Restruction Corporation Vail Marriott - Mezzanine Beam Repair FIREPROOFING - BEAMS Dry weight of sample 42.3 144 Client: Aspen Insulation (N/A) / Restruction (Dillon) Sedalia, CO 80135 3870 S Platte Ave 1 10/16 Dates Applied: Location: DENSITY DETERMINATION Location: 8/27/15, 9/1/15 Visual Observations / Discrepancies: Area Represented: Air Temperature (ºF): 9 MEASUREMENTS 12-INCH LENGTHAT EACH END OF 5 46 73 28 91 41 Inverness Dr East Englewood, CO 80112 Tel:(303)289 1989 Fax:(303)289 1686 Offices: Denver, Loveland, Gypsum, Grand Junction, Granby, Casper WY 7393 Dahlia Street Commerce City, CO 80022 Tel:(303)289 1989 Fax:(303)289 6742