HomeMy WebLinkAboutB15-0199_RESCheck_1434050400.pdfREScheck Software Version 4.6.0
Compliance Certificate
Project
Energy Code:2012 IECC
Location:Vail, Colorado
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:4,835 ft2
Glazing Area 45%
Climate Zone:6 (9248 HDD)
Permit Date:
Construction Site:
1463 Aspen Grove Lane
Vail, CO 81657
Owner/Agent:Designer/Contractor:
KH Webb Architects
Vail, CO 81657
97-477-2990
Permit Number:
Compliance: Passes using UA trade-off
19.4% Better Than Code Maximum UA:1631 Your UA:1315
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value
Glazing
or Door
U-Factor
UA
Roof: Flat Ceiling or Scissor Truss 3,901 59.0 0.0 0.024 92
Master Skylight: Wood Frame:Double Pane with Low-E 59 0.350 21
AG Walls: Wood Frame, 16" o.c.5,726 21.0 0.0 0.057 170
Windows: Wood Frame:Triple Pane with Low-E 1,994 0.200 399
Glass Doors: Glass 567 0.220 125
Solid Doors: Solid 179 0.300 54
BG Walls: Solid Concrete or Masonry
Wall height: 12.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
3,494 13.0 10.0 0.039 136
Floor Slab: Slab-On-Grade:Heated
Insulation depth: 6.0'
465 10.0 0.684 318
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.6.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Calcs By:
Derek Clery, Mechanical Engineer
Project Title:
Data filename: J:\Jobs\2015 - Jobs\15030.00 - 1463 Aspen Grove
Lane\Mechanical\Calculations\RESCheck\15030-RESCheck.rck
Page 1 of 2
06/10/15Report date:
Derek Clery, Mechanical Engineer 6/10/2015
6/10/15
Rader Engineering
derekc@raderengineering.com
970-875-7910 x305
Project Title:
Data filename: J:\Jobs\2015 - Jobs\15030.00 - 1463 Aspen Grove
Lane\Mechanical\Calculations\RESCheck\15030-RESCheck.rck
Page 2 of 2
06/10/15Report date: