HomeMy WebLinkAboutB15-0222_E0.0_1437493860.pdf sAlti OF go 4 Z• 4. TYPICAL or-0" CEILING �, 1 c ELEGTRIGAL GENERAL NOTES LIGHTING FIXTURES ABBREVIATIONS AND SYMBOLSicroJlii TYPICAL 8'-O" CEILING I. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A A AMPERE(S) 07/21/1. COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. A LUMINAIRE TYPE, REFERENCING LUMINAIRE 1 a SCHEDULE, TYPICAL ALL FIXTURES. AG ABOVE COUNTER 28 . MATERIALS AND INSTALLATION SHALL COMPLY WITH GODES,LAWS AND SUBSCRIPT, IF SHOWN, REFERENCES WALL AFF ABOVE FINISHED FLOOR ORDINANCES OF FEDERAL,STATE AND LOCAL GOVERNING BODIES HAVING SWITCH. TO BOTTOM OF DEVICE (SEE NOTE 4) © JURISDICTION. AFG ABOVE FINISHED GRADE A tO WALL MOUNTED LUMINAIRE 3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L.,ETL,GSA AHJ AUTHORITY HAVING JURISDICTION OR ANOTHER RECOGNIZED TESTING LAB. TOP OF CABINET POWER PANEL, FIRE SURFACE MOUNTED LUMINAIRE AIC AMPERES INTERRUPTING CAPACITY ALARM PANEL, OR 4. ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR,EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE I . RECESSED LUMINAIRE ATS AUTOMATIC TRANSFER SWITCH MASTER CLOCK BUILDING STANDARDS,EXCEPT AS NOTED OTHERWISE. CENTER OF CABINET 0 DOWNLIGHT LUMINAIRE BFF BELOW FINISHED FLOOR IVDA 5. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS,GOVERNMENTAL 1 FEES,TAXES AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND G CONDUIT N E COMPLETION OF THE ELECTRICAL WORK. 0 SURFACE CEILING LUMINAIRE - 0 TTO CENTER CATV CABLE TELEVISION J 6. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND {� PENDANT LUMINAIRE U A UTILITY COMPANIES SHOP DRAWINGS, WHICH ARE REQUIRED BY THESE AGENCIES, `f' GB CIRCUIT BREAKER Tr FOR THEIR APPROVAL. WALLWASH LUMINAIRE GT CURRENT TRANSFORMER h.a _c U TO CENTER 1. THE CONTRACTOR SHALL NOTIFY THE ARCHITEGT/ENGINEER/OWNER OF ANY 51-0" Eo Q $ 0 ❑='S/D --� MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE,UNSUITABLE, IN II STRIP LUMINAIRE DISC DISCONNECT 0 1 VIOLATION OF LAWS,ORDINANCES,RULES OR REGULATIONS OF AUTHORITIES HAVING ❑ 71-4" JURISDICTION. IU �I SURFACE OR PENDANT TRACK LUMINAIRE DH DISHWASHER E 6,-8„ TO BOTTOM 0 + $ S. FOR ALL JOBS THAT INCLUDE DEMOLITION WORK BY THE ELECTRICAL CONTRACTOR, DWG(S) DRAVIING(S) 1 AG AG AC AG DURING AND AFTER DEMOLITION,EG SHALL MAINTAIN CIRCUIT CONTINUITY TO ALL LINEAR PENDANT LUMINAIRE (LENGTH AS TD �� (E) EXISTING TO REMAIN „ EXISTING DEVICES THAT ARE TO REMAIN. EG SHALL REMOVE,RELOCATE,AND/OR INDICATED ON DRAWINGS/SCHEDULE) ❑ 6 -O REWORK ANY CONDUIT AND WIRING TO FACILITATE THE NEW CONSTRUCTION SCOPE EG ELECTRICAL CONTRACTOR o OF WORK. FOR A LUMINAIRES THAT ARE EXISTING TO REMAIN OR EXISTING TO BE EXIT LUMINAIRE - SHADED INDICATES ' 5'-4" 5'-OII RELOCATED,EG SHALL GLEAN LENSES AND REPLACE ALL EXTINGUISHED LAMPS, ®1 FACE/ DIRECTIONAL ARROWS AS SHOWN. EF EXHAUST FAN UON. �j7 q. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS,VISIT . . BATTERY PACK EMERGENCY LUMINAIRE (ER) EXISTING TO BE RELOCATED 3'_ " THE SITE,AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND EM EMERGENCY LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILL NOT RELIEVE EMERGENCY LUMINAIRE - SHADED ui 0 (SEE NOTE 6) THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. PROVIDE WITH INTEGRAL BATTERY BACKUP EPO EMERGENCY POWER OFF H 0 N I ID ND TO CENTER 10. ALL MATERIALS,AND EQUIPMENT SHALL BE ERECTED, INSTALLED,CONNECTED, EVIG ELECTRIC HATER COOLER c7 0 i' O CLEANED,ADJUSTED,TESTED,CONDITIONED,AND PLACED IN SERVICE IN O PORCELAIN LAMP HOLDER 2 f- � ACCORDANCE NITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. (R) EXISTING TO BE REMOVED no w U II. ALL GUTTING,DRILLING AND PATCHING OF MASONRY,STEEL OR IRON WORg STEP LIGHT TYPE LUMINAIRE K F FUSE 5 u I'-6" BELONGING TO THE BUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT �� BOLLARD OR POST TOP LUMINAIRE Q - cnn 7 HIS WORK MAY BE PROPERLY INSTALLED,BUT UNDER NO CONDITIONS MAY J FLA FULL LOAD AMPS ' ' ' STRUCTURAL WORK BE GUT,EXCEPT AT THE DIRECTION OF THE ARCHITECT-DESIGNER OR THEIR REPRESENTATIVE. o-El EXTERIOR AREA LIGHT FD GARBAGE DISPOSAL 12. E.G. IS TO REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ALL FIRE G GROUND RATED PENETRATION INSTALLATION REQUIREMENTS. E.G. IS TO NOTIFY ENGINEER GC GENERAL CONTRACTOR NOTES: AND ARCHITECT PRIOR TO INSTALLING ANY FIXTURES WITHIN A FIRE RATED CEILING OR WALL. FIRE RATING MUST BE MAINTAINED FOR THIS TYPE OF INSTALLATION WITH GFI GROUND FAULT CIRCUIT INTERRUPTER I. WHERE MULTIPLE LINE VOLTAGE DEVICES ARE SHOWN ADJACENT TO EACH OTHER, lig DRYWALL TENTING. WIRING DEVICES THEY ARE ALL TO SHARE THE SAME JUNCTION BOX, UP TO FOUR GANGS. 13. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES,CATALOG NUMBERS,GUTS, HP HORSEPOWER DIAGRAMS AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY C DUPLEX RECEPTACLE IDF INTERMEDIATE DISTRIBUTION FACILITY 2. WHERE MORE THAN FOUR DEVICES ARE SHOWN ADJACENT TO EACH OTHER, AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS,FOR EXAMPLE,ALL LIGHTING FIXTURES,PARTIAL SUBMITTALS HILL NOT BE REVIEWED. FOUR FLEX RECEPTACLE IG ISOLATED GROUND DEVICES ARE TO STACK VERTICALLY ABOVE ONE ANOTHER IN TWO ROWS IN AS 41 CSIII SMALL OF GANG BOXES AS POSSIBLE. I.E. SIX DEVICES WILL USE TWO THREE 14. SUBMIT(3) COPIES OF THE FOLLOWING SHOP DRAWINGS FOR REVIEW. ISG SHORT CIRCUIT CURRENT 0 GANG BOXES, FIVE DEVICES WILL USE ONE THREE GANG AND ONE TWO GANG BOX. A. DISCONNECTS -e SINGLE RECEPTACLE B. LIGHT FIXTURES KVA KILOVOLT AMPERE(S) G. LIGHTING CONTROLS COMBO RECEPTACLE/SWITCH 3. SEPARATELY GANGED DEVICES ARE NOT ALLOWED TO BE INSTALLED ADJACENT D. PROVIDE "AS-BUILT" DRAWINGS AND SUBMIT TO ARCHITECT/DESIGNER. KH KILOWATTS) TO ONE ANOTHER HORIZONTALLY WITHIN THE SAME STUD BAY. IM I . ALL MATERIAL,EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW,UNLESS 4 SWITCHED DUPLEX RECEPTACLE LTG LIGHTING SPECIFICALLY INDICATED AS EXISTING TO BE REUSED. 4. AUDIBLE/VISUAL FIRE ALARM DEVICES SHOWN ARE TO BE MOUNTED AT (10" OR 6" IF® SPECIAL PURPOSE RECEPTACLE MCA MINIMUM CIRCUIT AMPERES) O BELOW CEILING, WHICHEVER IS LOWER. ADA STROBES TO BE MOUNTED AT 80" Il. ALL NEW CIRCUIT BREAKERS FOR EXISTING PANELBOARDS SHALL MATCH EXISTING A V BUILDING PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR FLOOR MOUNTED SPECIAL PURPOSE MCB MAIN GIRGUIT BREAKER AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER. SHALL PROVIDE NEW TYPE WRITTEN PANEL DIRECTORIES FOR ALL PANELS WHICH ®❑ RECEPTACLE J HAVE CHANGED. PANELBOARD SHALL BE MARKED WHERE THE SOURCE OF POWER MDP MAIN DISTRIBUTION CENTER - a 5. MAXIMUM ELEVATION FOR ALL LOAD CENTER CIRCUIT BREAKERS SHALL NOT SUPPLY ORIGINATES,AND IF SERIES COMBINATION SYSTEMS ARE UTILIZED AND El FLOOR MOUNTED RECEPTACLE DUPLEX/QUAD MDF MAIN DISTRIBUTION FACILITY EXCEED 48" AFF, WITHIN DWELLING UNITS. THEIR LISTED AMPERE RATING. p 14 cs IS. SHOULD ACTUAL FIELD CONDITIONS REQUIRE INDICATED CIRCUIT DESIGNATIONS TO 1-5R-I SURFACE RACEWAY MLO MAIN LUGS ONLY F ""AS-BUILTDRAWINGS. 6. THE E.G. SHALL REFER TO ARCHITECTURAL ELEVATIONS TO COORDINATE ALL VARY, INDICATE THE CIRCUIT NUMBER USED ON THE MTS MANUAL TRANSFER SWITCH Z COUNTER HEIGHTS. ALL AG DEVICES SHALL HAVE BOTTOM OF BACK-BOX /0 CLOCK RECEPTACLE W Z Iq. ALL SERVICE EQUIPMENT(OTHER THAN IN DWELLING UNITS) SHALL BE LEGIBLY MH MICROWAVE 2 J MOUNTED 4" ABOVE THE BACK/SIDE SPLASH. MARKED IN THE FIELD BY THE ELECTRICAL CONTRACTOR WITH THE MAXIMUM 1.1. 0 W JUNCTION BOX AVAILABLE FAULT CURRENT AS INDICATED WITHIN THESE DOCUMENTS. THE FIELDNG NORMALLY CLOSED > la H MARKINGS) SHALL COMPLY WITH ELECTRICAL SPECIFICATIONS FOR READABILITY y 1 MOUNTING HEIGHTS DETAIL AND DURABILITY. /0WALL MOUNTED J-BOX NL NIGHT LIGHT - SEE GENERAL NOTES 0 CC cc 20. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL HIRING p FLOOR MOUNTED JUNCTION BOX NO NORMALLY OPEN 0. I2C LL E1.0 SCALE: N.T.S. THROUGHOUT THE EXTENT OF THE REQUIRED DISTRIBUTION SYSTEM. 2 W A. UTILIZE ELECTRICAL METALLIC TUBING(EMT), MINIMUM SIZE OF 3/4", IN THE OAE OR APPROVED EQUAL FOLLOWING LOCATIONS: �� MOLDED CASE CIRCUIT BREAKER IN 0 a. FEEDERS ENCLOSURE OH OVERHEAD Z J b. PONBRANCH CIRCUIIRCUITTS HOMERUN P POLE Z I J c. BRANCH GIRGUITS IN CONGEALED OR EXPOSED LOCATIONS NON-FUSED DISCONNECT SWITCH d. TELEPHONE/DATA/GATV ROUGH-IN B. UTILIZE METAL-CLAD CABLE (MC) IN THE FOLLOWING LOCATIONS: FUSED DISCONNECT SWITCH PART PARTIAL CIRCUIT W _. a. BRANCH CIRCUIT IN CONGEALED LOCATIONS PH, PHASE ~ la b. FINAL CONNECTION TO RECESSED LIGHTING FIXTURES Q Q ® MAGNETIC CONTROLLER (STARTER) 22. ALL NEW CIRCUITS SHALL HAVE A GROUND WIRE INSTALLED. PNL PANEL 0 0-1 COMBINATION STARTER/DISCONNECT SWITCH RCPT RECEPTACLE r IIIII 23. ALL HIRING NOT INSTALLED IN CONDUIT AND INSTALLED IN THE CEILING SPACE W N SHALL BE PLENUM RATED. 4 MOTOR REF REFRIGERATOR F 24. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAYO RELAY (RL) RELOCATED BE REQUIRED TO ENCLOSE RECEPTACLES. SPD SURGE PROTECTION DEVICE HO 25. EACH SWITCH,LIGHT,RECEPTACLE AND OTHER MISCELLANEOUS DEVICE SHALL BE TG TIME CLOCK J PROVIDED HITH A GALVANIZED OR PRESSED STEEL OUTLET BOX OF THE KNOCKOUT UG UNDER GOUNTER/GABINET m TYPE,OF NOT LESS THAN NO. 14 U.S. GAUGE STEEL. CONDUITS SHALL BE FASTENED 0 PHOTOCELL HITH LOCKNUTS AND BUSHINGS AND ALL UNUSED KNOCKOUTS MUST BE LEFT SEALED. UG UNDERGROUND U111) r THERE MUST BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND DEEP BOXES SHALL BE INSTALLED WHERE REQUIRED. BOXES SHALL BE SECURELY AND $TTHERMAL OVERLOAD SWITCH O UON UNLESS OTHERWISE NOTED F ADEQUATELY SUPPORTED. 0 SINGLE POLE SWITCH V VOLT(S) J 26. IN SUSPENDED CEILINGS,SUPPORT CONDUIT AND JUNCTION BOXES DIRECT FROM THE STRUCTURAL SLAB,DECK,OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING $3 3-WAY SWITCH W WATT(S) OR HIRE A BRANCH CIRCUIT CONDUITS SHALL NOT BE CLIPPED TO THE CEILING SUPPORT HIRES OR SPLINE UNLESS THE CEILING SYSTEM HAS BEEN SPECIFICALLY DESIGNED FOR HG WIRE GUARD THAT PURPOSE. $4 4-WAY SWITCH HP WEATHERPROOF 2q. ALL RECEPTACLES SHALL BE SPECIFICATION GRADE NEMA 5-2OR,UNLESS $K KEY OPERATED SWITCH XFRM TRANSFORMER OTHERWISE NOTED. lig 30. ALL LIGHT SWITCHES SHALL BE SPECIFICATION GRADE,QUIET OPERATION RATED $D DIMMER SWITCH 120/217 VOLT,20 AMPS,UNLESS OTHERWISE NOTED. OX POOL EQUIPMENT SCHEDULE NOTATION $DOOR RECESSED DOOR SWITCH 31. ALL FACE PLATE AND DEVICE COLORS SHALL BE APPROVED BY ARCHITECT OR OWNER. WS(x) LIGHTING CONTROL SYSTEM LOW VOLTAGE O OWNER EQUIPMENT SCHEDULE NOTATION DIGITAL WALL STATION. (X) INDICATES 32. EMERGENCY LUMINAIRES SHALL SENSE UNSWITGHED POWER TO THE SPACE AND INDIVIDUAL WALL STATION ADDRESS. REFER OPERATE AUTOMATICALLY UPON LOSS OF NORMAL POHER. ALL EMERGENCY TO LIGHTING CONTROL ONELINE DRAWING. ® MECHANICAL EQUIPMENT SCHEDULE NOTATION LUMINAIRES SHALL HAVE REMOTE TEST SWITCHES AND VISIBLE INDICATING LIGHTS. CONNECT THE EMERGENCY BATTERY BALLAST TO THE UN-SWITCHED LEG OF THE LIGHTING GIRGUIT INDICATED. a SINGLE RELAY OCCUPANCY SENSOR. Ox DETAIL NOTE 33. ALL BATTERY BACKUP EMERGENCY LIGHTING AND EXIT LIGHTS SHALL BE HIRED EL DOUBLE RELAY OCCUPANCY SENSOR. ISSUED FOR: DATE: AHEAD OF ANY LOCAL SWITCHING,UON. DELTA REVISION NOTE REVIEW SET 6.24.15 OG CE I L I NG MOUNTED OCCUPANCY SENSOR. x - 34. PROVIDE OWNER HITH A COMPLETE LISTING OF ALL LAMPS UTILIZED ON THE PROJECT INCLUDING MANUFACTURER AND CATALOG INFORMATION. PROVIDE A p ELECTRICAL WIRE SIZE SUGGESTED SOURCE, INCLUDING CONTACT NAME AND PHONE NUMBER,FOR REORDERING. 35. THE CONTRACTOR SHALL VERIFY THE CEILING TYPE BEFORE ORDERING LIGHTING FIXTURES. 36. ROUGH-IN FOR MECHANICAL EQUIPMENT SHALL ONLY OCCUR AFTER MECHANICAL FIRE ALARM SYSTEM NOTES EQUIPMENT SUBMITTALS ARE THOROUGHLY REVIEWED FOR CHANGES. NOTIFY ENGINEER OF ANY DISCREPANCIES. E.G. TO COORDINATE THE REQUIREMENTS FOR FIRE ALARM SYSTEM DEVICES AS A 'DESIGN-BUILD' PROCESS. NEW FIRE ALARM DEVICES TO MATCH EXISTING 31 FINAL LAYOUT AND QUANTITY OF ALL FIRE ALARM DEVICES SUBJECT TO APPROVAL MANUFACTURER'S SPECIFICATIONS. CONTRACTOR TO PROVIDE NEW FIRE ALARM OF LOCAL AUTHORITY HAVING JURISDICTION. DEVICES PER APPLICABLE GODES AND LOCAL AHJ. CONTRACTOR TO CONFIRM 35. THE POHER AND CONTROL REQUIREMENTS FOR ALL EQUIPMENT CONNECTIONS SHALL EXISTING FIRE ALARM SYSTEM HAS THE CAPACITY FOR NEW DEVICES AND ADJUST BE CONFIRMED WITH APt'ILOVED SHOP DRAWINGS PRIOR TO ELECTRICAL ROUGH-IN. SYSTEM AS REQUIRED. FINAL POHER REQUIREMENTS, DIMENSIONED ROUGH-IN LOCATIONS,LOH VOLTAGE SYSTEM CONNECTIONS,ETC. SHALL BE CONFIRMED AND MODIFIED AS REQUIRED. 2011 MICHAEL SUMAN ARCHITECT,LLC. 3q. ALL DEVICES IN OR ABOVE COUNTERS SHALL HAVE LOCATIONS AND MOUNTING C ALL RIGHTS RESERVED. HEIGHTS CONFIRMED HITH ARCHITECTURAL ELEVATIONS $ OWNER PRIOR TO SCALE: 1/4" 1'0" ROUGH-IN. ANY ADJUSTMENTS TO MOUNTING HEIGHTS REQUIRED BY LACK OF COORDINATION WILL BE AT THE CONTRACTOR'S EXPENSE. DRAWN: AEDG 40. ALL EXISTING ELECTRICAL SERVICES NOT SPECIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL REMAIN AS THEY PRESENTLY EXIST. 41. G.G. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL - PROJECT#: DEVICES,CONDUITS,FIXTURES AND EQUIPMENT. TURN EQUIPMENT OVER TO OWNER 1 900 Wazee Street, Suite #350 SHEET TITLE: COVER SHEET AS INDICATED OR REGYGLE/DISGARD ALL EQUIPMENT AS REQUIRED. E.G. SHALL BE - - RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER. ` ; .,-_.� Denver, Colorado 80202 _ 303.296.3034 VOICE 42. WHERE EXISTING CEILINGS ARE REVISED FROM ACCESSIBLE TO NON-ACCESSIBLE, c 303.296.3035 FAX CONTRACTOR IS TO INCLUDE IN HIS BID THE COSTS ASSOCIATED WITH RELOCATING *.i.wr ALL ELECTRICAL EQUIPMENT REQUIRING ACCESS ABOVE THE EXISTING CEILING TO A - aedesign@aedesign-inc.com NEW ACCESSIBLE CEILING LOCATION APPROVED BY ARCHITECT AND ENGINEER. ____ _____ www.aedesign-inc.com THE USE OF ACCESS PANELS IN THE NEW CEILING TO AVOID RELOCATION OF THIS EQUIPMENT IS NOT ACCEPTABLE. ARCHITECTURAL ENGINEERING E0. 0 DESIGN GROUP, INC. AEDGJOB# 3032.00