HomeMy WebLinkAboutB15-0250_A150_1442254080.pdfA/TENT A/TENT
A/TENT
A/TENT
A/TENT
A/TENT
A/TENT
A/TENT
A/TENT A/TENT A/TENT A/TENT
A/TENT A/TENT A/TENT A/TENT
B
B
B
B
B
B
B
B
D2 D2
D3 D3 D3 D3
D4 D4 D4 D4
A A A A
A A A A
A
A
A
A
A
A A
A A
A A A
A
A
A
A
A A
A
A
A
A
A
A A A A
A A
A A
A
A A A
A
A
A A
A
A
A
A A A
A A A A
A A
A A
A
A
A
A
A A
A
A
A
A
A
E
E
E
D1
F
F
F
F F
E
G
H
H
J
J
J
J
J
J
J J J
J
J
H
A/TENT
K
K
K
K
3' - 9" 1' - 9"
4' - 9"
4' - 9" 4' - 9" 4' - 9" 4' - 1 9/16"
4' - 1 3/8"
4' - 1 3/8"
3' - 7"
EQ.
EQ.
1' - 9"
EQ. EQ.
4' - 2" 4' - 2" 4' - 2"
1' - 4 1/4" CTR ON WINDOW
CTR ON WINDOW
CTR ON HALLWAY
EQ. EQ.
VFY ELEV.
HOISTWAY REQ'S
EQ. EQ.
EQ. EQ.
EQ.
EQ. 2' - 0"
2' - 0"
EQ.
EQ. EQ. EQ.
1' - 10" EQ. EQ.
EQ. EQ. ALIGN
ALIGN
ALIGN
ALIGN
CTR ON HALLWAY
ALIGN
ALIGN
1' - 10"
VFY HT. AND SPACING
WITH STAIR DESIGN
EQ. EQ.
EQ. EQ.
EQ.
EQ.
ALIGN
3' - 3 5/16" 3' - 3 5/16"
3' - 9"
EQ. EQ.
EQ. EQ. 2' - 5 3/8"
3' - 6"
3' - 6" 3' - 6"
3' - 6"
3' - 6"
3' - 6"
EQ.
EQ. EQ.
EQ. 5' - 5 3/8"
5' - 5 3/8" 4' - 11 1/4"
3' - 9 1/4"
3' - 9 1/4"
CTR ON DOOR
CTR ON WINDOW
2' - 8"
2' - 8" 2' - 6"
EQ. EQ.
EQ.
EQ.
EQ. EQ.
EQ. EQ.
3' - 0"
2' - 6"
2' - 6" EQ.
EQ.
4' - 0"
4' - 0" EQ.
EQ.
EQ.
EQ.
READING LIGHTS/
VFY W/ BUNK
LAYOUT
READING LIGHTS/
VFY W/ BUNK
LAYOUT
4' - 2 5/8" 4' - 6"
4' - 10 5/8" 4' - 10 5/8"
EQ.
EQ. 4' - 0"
4' - 0"
4' - 6"
2' - 2"
2' - 2" EQ. EQ.
EQ. EQ.
EQ. EQ.
EQ. EQ.
EQ.
EQ. EQ. EQ.
1' - 3"
EQ. EQ.
CTR ON DOOR
ALIGN
ALIGN
EQ. EQ. ALIGN
1' - 3"
6'-6" ABV
FIN. GRADE
6'-6" ABV
FIN. GRADE
6'-6" ABV
FIN. GRADE
12" ABV
FIN. GRADE
12" ABV
FIN. GRADE
VFY W/ RETAINING WALL
VFY
VFY HT. WITH STAIR
DESIGN
EQ. EQ.
EQ.
EQ. 4' - 0"
ALIGN
UNDER CAB UNDER CAB
EX1
EX1
EX1
EX1
EX2
EX2
S3
S3 S3 S3 S 3 S
3
S
S 3 S
3
S
SS S3
S S
SSS 3SS
S
S
3
S3
S 3S 3S
3
S3 S 3S
3
S3
S SS
S
S
SS
S
S
3
S3
S S
S3
S3
SSS
SS
S
S S
S 3
S
co2
SD
EQ. EQ.
3' - 1 1/4" 3' - 1 1/4"
SD
EQ. EQ.
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
SD
EQ. EQ.
SD
EQ. EQ.
SD
SD
J
J
J
J
LESS THAN 18"
AFF VFY W/ STAIR
LAYOUT
RCP LEGEND
A JUNO/4" LOW VOLTAGE IC 50W/MR16 #1C44N/
TRIM #447SQ-HZ-WH
E
H
F
G
B JUNO /4" LENSED LOW VOLTAGE IC 50W/MR16
/IC44N/TRIM #441SQ-W-WH
K
SD
J
co2
D3/ DECO FIXTURE/ BATH
WALL SCONCE
D1/ DECO FIXTURE HALL
D2/ DECO FIXTURE/ BATH
WALL SCONCE
D4/ DECO FIXTURE/ BATH
WALL SCONCE
EX1/EXTERIOR WALL SCONCE/ MODERN FORMS/
#UU504623/ 16" HT/UL LISTED/ DARK SKY
COMPLIANT/BRONZE FINISH
J
EX2/ EXT. STEP LIGHT/FX LUMINAIRE/
#LM-20-L4
D5/ DECO FIXTURE/ SURFACE
MTD HANGING FIXTURE
D6/ DECO FIXTURE/ SURFACE
MTD HANGING FIXTURE
D7/ DECO FIXTURE/ WALL MTD
BATH SCONCE
D8/ DECO FIXTURE/ WALL MTD
BATH SCONCE
D10/ DECO FIXTURE/ SURFACE MTD.
HANGING FIXTURE(DINING)
D11/ DECO FIXTURE/ SURFACE MTD.
HANGING FIXTURE (KIT ISLAND)
D12/ DECO FIXTURE/ SURFACE MTD.
HANGING FIXTURE(FAM. DINING)
L
M
D13/ DECO FIXTURE/ WALL MTD.
SCONCE(STAIRS)
D14/ DECO FIXTURE/ SURFACE MTD
FIXTURE/SEMI RECESSED(HALL)
D15/ DECO FIXTURE/ WALL MTD.
BATH SCONCE
D16/ DECO FIXTURE/ WALL MTD.
BATH SCONCE
D18/ DECO FIXTURE/ SURFACE MTD.
HANGING FIXTURE( M BDRM)
D19/ DECO FIXTURE/ COUNTER MTD.
BATH LIGHT
D20/ DECO FIXTURE/ WALL MTD.
BATH SCONCE
SURFACE MTD. FLOURESCENT 2X4
CEILING MTD FIXTURE
WALL MTD. SCONCE- ELEVATOR(VFY)
UNDER CABINET LED STRIP
LED TOE KICK LIGHT
READING LIGHT
SURFACE MOUNTED MONO POINT
5" DIA RECESSED CAN LIGHT(ADJ)/ VAULTED AREAS
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
BATH EXHAUST FAN
D9/ DECO FIXTURE/ SURFACE MTD.
HANGING FIXTURE(FOYER)
EX3/ EXT. PATH LIGHT/TEKA/
#1130
RCP NOTES
1. NEW CONSTRUCTION: ALL LIGHT FIXTURES & OTHER CEILING ELEMENTS SHALL BE LOCATED PER RCP
2. COORDINATE ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS
INDICATED ON THE DESIGNERS' DRAWINGS.
3. ANY ACCESS HATCHES NOT SHOWN ON THE CEILING PLAN BUT REQUIRED BY PLUMBING, MECHANICAL, OR ELECTRICAL SYSTEMS SHALL BE REVIEWED WITH ARCHITECT FOR
LOCATION.
7. ALL NEW GYPSUM BOARD SOFFITS AND CEILINGS ARE TO BE PAINTED - VFY COLOR # W/ ARCHITECT
9. DIMENSIONS OF SPECIALTY LIGHT FIXTURES ARE TO CENTER OF FIXTURE, UON
10. PROVIDE GWB TENT FOR ALL FIXTURES AT ALL CONDITIONS WHERE FIXTURE PENETRATES RATED FLOOR ASSEMBLY
11. REFER TO ELECTRICAL DRAWINGS FOR SWITCHING AND OR POWER/ZONE
NOT FOR CONSTRUCTION
Project number
Date
Drawn by
7/10/2015 4:10:46 PM
A150
Level 1 Reflected Ceiling Plan
HUGHES-1
LOT 3 / 994 PTARMIGAN RD
VAIL,CO
Hughes Residence
07.10.2015
HB
1/4" = 1'-0"
1
Level 1 Reflected Ceiling Plan
No. Description Date
07.10.2015
01 TOV BLDG. PERMIT
09/14/15