HomeMy WebLinkAboutB15-0250_B15-0250 REV1 Transmittal_1443545340.pdfTRANSMITTAL FORM
Project Street Address:
__________ ______________________________ ___________
(Number) (Street) (Suite #)
Building/Complex Name: ________________________________
Building Permits:
Revised ADDITIONAL Valuations (Labor & Materials)
(DO NOT include original valuation)
Building: $_____________________
Plumbing: $_____________________
Electrical: $_____________________
Mechanical: $_____________________
Total: $_____________________
Description of Transmittal/ List of Changes, Items Attached:
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
(use additional sheet if necessary)
Application/Permit #(s) information applies
to: Attention: ( ) Revisions
( ) Response to Correction Letter
____________________________________ __________________________ ___attached copy of correction letter
( ) Deferred Submittal
____________________________________ __________________________ ( ) Other
Use this form when submitting additional information for planning applications or building permits.
This form is also used for requesting a revision to building permits. A two hour minimum building review
fee of $110 will be charged upon reissuance of the permit.
Date Received:
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970.479.2128
www.vailgov.com
Development Review Coordinator
For Office Use Only:
Fee Paid:
Received From:
Cash _____ ____ Check # __ _ _______
CC: Visa / MC Last 4 CC # exp. date:
Authorization #
Applicant Information
(architect, contractor, owner/owner’s rep)
Contact Name: ________________________________________
Address:
City _____________________ State: _______ Zip: ____________
Contact Name: _________________________________________
Contact Phone: _________________________________________
Contact E-Mail: _________________________________________
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according
to the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
ordinances of the Town applicable thereto.
X___________________________________________________
Owner/Owner’s Representative Signature (Required)
SYMBOL DESCRIPTION
PENETRATION THRU
STRUCTURAL MEMBER
OVERFRAMING
CAST-IN-PLACE CONC BELOW
X
FTG MARK
T/FTG EL
F1
XX'-X"
SYMBOL DESCRIPTION
MOMENT CONNECTION
DECK TYPE
DECK SPAN DIRECTION
T/PLYWOOD
WS1
XXX'-XX"
BEAM SIZE
(XXX'-XX")
EL OF T/STEEL
STEEL BEAM
SYMBOL DESCRIPTION
ELEVATION CALLOUTXXX'-XX"
STEP
SLOPE
KEY NOTE
SUBGRADE
FORM SAVER
DRAWING REVISION NUMBER
CURRENT REVISION CLOUD
1
X
SERVICE LOAD PROVIDED FOR
SPECIALTY DESIGNER
WELDED-WIRE REINFORCEMENT
SECTION OR
DETAIL CUT
SHEET NUMBER
ELEVATION CUT
SHEET NUMBER
NEW GRID LINES
X
XX
X
XX
X
SOGXXA
XXX'-XX"
SLAB THICKNESS
TYPE
T/SLAB
SLAB TYPE
COLUMN/POST MARK
BASE PLATE TYPE
1 BP-1
WOOD SHEAR WALL ABOVE FLOOR
CAST-IN-PLACE CONC ABOVE
INDICATES DIMENSIONS
OF WALL CORNER
ZONES, TYP5'-6"5'-6"5'-6"5'-6"5'-6"5'-6"5'-6"5'-6"
WALL CORNER ZONES DIAGRAM
1. GENERAL:
1A.THE FOLLOWING PORTIONS OF THE STRUCTURAL DESIGN WILL NOT BE SUBMITTED AT THE
TIME OF PERMIT APPLICATION. WHEN RECEIVED AND REVIEWED, THESE DEFERRED SUBMITTAL
ITEMS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL BY THE CONTRACTOR:
- ARCHITECTURAL/METAL CLADDING PANELS
- METAL AND GLASS RAILINGS
- SNOW GUARDS
1B.CONNECTION OF DEFERRED SUBMITTAL ITEMS TO PRIMARY STRUCTURE BY DEFERRED
SUBMITTAL SUPPLIER. DEFERRED SUBMITTAL SUPPLIER TO PROVIDE CONNECTIONS AND
FRAMING ARRANGEMENT TO AVOID LOADING WHICH EXCEEDS THE CAPACITY OF THE ELEMENT
BEING ATTACHED TO. REFERENCE LOAD MAPS FOR MECHANICAL, ELECTRICAL, PLUMBING AND
FIRE SPRINKLER LOAD ALLOWANCES.
1C.ALL DEFERRED SUBMITTALS TO BE ATTACHED TO PRIMARY STRUCTURE WITH A PINNED
CONNECTION. MOMENT CONNECTIONS TO PRIMARY STRUCTURE NOT PERMITTED UNLESS NOTED
ON DRAWINGS OR APPROVED BY ENGINEER IN WRITING PRIOR TO SUBMITTAL OF DRAWINGS OR
CALCULATIONS.
1D.LOADING AND LOCATION FOR ATTACHMENT OF DEFERRED SUBMITTAL ITEMS ARE NOTED ON
DRAWINGS AND ARE NOT TO BE RE-LOCATED OR INCREASED WITHOUT WRITTEN APPROVAL.
1G.WALLS, GRADE BEAMS AND THE UNDERSIDE OF CONCRETE ON METAL DECK SHALL BE
CONSIDERED CRACKED FOR THE PURPOSE OF DESIGNING ANCHORS FOR ATTACHMENT OF
DEFERRED SUBMITTAL ITEMS.
1H.SUBMIT STAMPED STRUCTURAL CALCULATIONS FOR ALL DEFERRED SUBMITTAL ITEMS PRIOR
TO OR CONCURRENTLY WITH DRAWINGS OR PRODUCT DATA. INCLUDE ANALYSIS OF ATTACHMENT
TO PRIMARY STRUCTURE. INCLUDE CURRENT ICC REPORT WITH ALL PROPRIETARY STRUCTURAL
ELEMENTS AND ANCHORS/FASTENERS.
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:38 PMS001
NOTES
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
SHEET NUMBER SHEET TITLE PERMIT SET FND SET
S001 NOTES X X
S002 NOTES X X
S003 QUALITY ASSURANCE X X
S100 LEVEL 1 FLOOR PLAN X X
S100a LEVEL 1 FND DIMENSIONS X
S101 LEVEL 2 FLOOR PLAN X X
S102 LEVEL 3 FLOOR PLAN X
S103 ROOF PLAN X
S200 PARTIAL PLANS X
S300 TYP CONCRETE DETAILS X X
S310 TYP FOUNDATION DETAILS X X
S311 TYP FOUNDATION DETAILS X X
S320 SOG DETAILS X X
S500 STEEL DETAILS X X
S501 STEEL DETAILS X
S600 TYPICAL WOOD DETAILS X X
S601 TYPICAL WOOD DETAILS X X
S602 TYPICAL WOOD DETAILS X
S603 SHEAR WALL DETAILS X
S610 FLOOR DETAILS X
S611 FLOOR DETAILS X
S620 ROOF DETAILS X
STRUCTURAL DRAWING LISTSYMBOLS LEGEND
ABBREVIATIONS
T Top
T&B Top and Bottom
T/ or T.O. Top of
THK Thick or Thickness
TOC Top of Concrete
TOF Top of Footing
TOS Top of Steel
TOW Top of Wall
TRANS Transverse
TYP Typical
ULT Ultimate
UNO Unless Noted Otherwise
Vasd Service Level/Nominal
Design Wind Speed
VERT Vertical
VIF Verify in Field
Vult Ultimate Design Wind
Speed
W/ With
W/O Without
WD Width or Wood
WF Wide Flange
WWR Welded Wire
Reinforcement
WxH Width x Height
NS Non-Shrink or Near Side
NTS Not To Scale
NWC Normal Weight Concrete
O.F. Outside Face
OC On Center
OD Outside Diameter
OH Opposite Hand
OPNG Opening
OPP Opposite
OVS Oversized
PAF Power Actuated Fastener
PEN Penetration
PERP Perpendicular
PL Plate (Steel)
PLF Pounds Per Lineal Foot
PREFAB Prefabricated
PRELIM Preliminary
PSF Pounds Per Square Foot
PSI Pounds Per Square Inch
QTY Quantity
R Radius or Rain Load
RAD Radius
RE: or REF Refer to (Reference)
REINF Reinforce(ing)(d)(ment)
REQD Required
REQT(S) Requirement(s)
RET Return
RO Rough Opening
S South
SC Slip Critical
SCHED Schedule
SIM Similar
SLH Short Leg Horizontal
SLV Short Leg Vertical
SOG Slab on Grade
SP Space(s)
SP @ Space at
SPECS Specifications
SS Stainless Steel
STD Standard
STIFF Stiffener
STL Steel
STR Structural
SW Shearwall
SYM Symmetrical
HDAR Headed Anchor Rod
HDG Hot Dipped Galvanized
HK Hook
HORIZ Horizontal
HT Height
I.F. Inside Face
ID Inside Diameter
IN Inch
INT Interior
JST Joist
JT Joint
k Kip
L Length or Live Load
LB(S) Pound(s)
LCE Compression Embedment
LCS Compression Lap Splice
LDH Hook Development Length
LG Length
LL Live Load
LLH Long Leg Horizontal
LLV Long Leg Vertical
LOC(S) Location(s) or Locate
LONG Longitudinal
LSL Laminated Strand Lumber
LT Light
LTE Tension Embedment
LTS Tension Lap Splice Length
LTWT Lightweight
LVL Level or Laminated
Veneer Lumber
LWC Light Weight Concrete
MATL Material
MAX Maximum
MECH Mechanical
MEP Mech/Elect/Plumb
MIN Minimum
MISC Miscellaneous
ML Micro-Lam
MNFR Manufacturer
MTL Metal
N North
N-S North-South
NIC Not in Contract
NO or # Number
NOM Nominal
DIAG Diagonal
DIM Dimension
DN Down
DTL(S) Detail(s)
DWG(S) Drawing(s)
DWL(S) Dowels(s)
(E) or
EXIST
Existing
E-W East-West
EA Each
EC Epoxy Coated
EE Each End
EF Each Face
EJ Expansion Joint
EL Elevation
ELEV Elevator
EMBED Embedded
EN Edge Nail
ENGR Engineer
EOR Engineer-of-Record
EQ Equal
EQ SP Equally Spaced
EQUIP Equipment
ES Each Side
EW Each Way
EXP Expansion
EXP ANCH Expansion Anchor
EXT Exterior
FAB Fabricate
FD Footing Dowel
FF Finished Floor
FIN Finish(ed)
FLG Flange
FLR Floor
FND Foundation
FS Far Side
FT Foot or Feet
FTG Footing
FV Field Verify
GA Gage or Gauge
GALV Galvanized
GL Glu-lam
GR Grade or Grind
GR BM Grade Beam
HAS or
HDAS
Headed Anchor Stud
HD Headed or Holdown
/ Per
@ At
ACI American Concrete
Institute
ADDNL Additional
AESS Architecturally Exposed
Structural Steel
ALT Alternate
APA American Plywood
Association
ARCH Architect or Architectural
B/ or BO Bottom of
BD Board
BG Backgouge
BL Brick Ledge
BLDG Building
BLKG Blocking
BM Beam
BN Boundary Nail
BOS Bottom of Steel
BOT or B Bottom
BRG Bearing
BSMT Basement
BTWN Between
CC Center to Center
CF Cold Formed
CG Center of Gravity
CIP Cast-In-Place
CJ Control Joint
CJP Complete Joint
Penetration
CL Centerline
CLR Clear
COL Column
CONC Concrete
CONN Connection
CONST Construction
CONT Continue or Continuous
CONTR Contractor
COORD Coordinate
CSJ Construction Joint
CTR(D) Center(ed)
d Penny
D or DL Dead Load
DAS Deformed Anchor Stud
DBL Double
DFS Deferred Submittal
DIA or Ø Diameter
DESIGN CRITERIA
GRAVITY LOADS TABLE
LOCATION DEAD LOAD (PSF) LIVE LOAD (PSF)
ROOF 27 20 MIN UNIFORM
LOAD, SEE NOTE 6B
FOR SNOW LOADS
RESIDENTIAL 44 40
FLAGSTONE
PATIO
73 100 MIN UNIFORM
LOAD, SEE NOTE 6B
FOR SNOW LOADS
ATTIC 20 20
1. CODES AND STANDARDS:
1A.GENERAL DESIGN
- INTERNATIONAL RESIDENTIAL CODE 2012 WITH 2012 TOWN OF VAIL AMENDMENTS
2. SEISMIC LOADS
- SEISMIC DESIGN CATEGORY = B
- RISK CATEGORY = II
- EARTHQUAKE IMPORTANCE FACTOR, Ie = 1.0
- MAPPED SPECTRAL RESPONSE ACCELERATION, Ss= 0.255
- MAPPED SPECTRAL RESPONSE ACCELERATION, S1= 0.073
- DESIGN SPECTRAL RESPONSE COEFFICIENT, SDs = 0.271
- DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 = 0.116
- SOIL SITE CLASS = D
- ONE-FAMILY DWELLINGS ASSIGNED TO SEISMIC DESIGN CATEGORY B ARE EXEMPT FROM SEISMIC
DESIGN PER IBC 2012, SECTION 1613.1.
3. WIND LOADS
- RISK CATEGORY = II
- BASIC ULTIMATE WIND SPEED Vult = 115 MPH
- BASIC NOMINAL WIND SPEED Vasd = 90 MPH
- EXPOSURE CATEGORY = B
- INTERNAL PRESSURE COEFFICIENT, GCpi = +/- 0.18
4. DESIGN WIND PRESSURE FOR COMPONENTS AND CLADDING AND ELEMENTS DESIGNED BY THE
CONTRACTOR
- PRESSURES LISTED BELOW ARE ULTIMATE BASED ON A 10 SF EFFECTIVE WIND AREA. FINAL
CALCULATIONS TO BE COMPLETED BY CONTRACTOR
- SEE ‘WALL CORNER ZONES DIAGRAM’
- TYPICAL WALL AREA INWARD PRESSURE = 19 PSF
- TYPICAL WALL AREA OUTWARD PRESSURE = 20 PSF
- WALL CORNERS(OUTWARD) = 25 PSF
- ROOF AREA (OUTWARD) = 22 PSF
5. LATERAL LOAD RESISTING SYSTEM DESCRIPTION:
- SHEATHED WOOD DIAPHRAGM SPANNING TO SHEATHED WOOD SHEAR WALLS SUPPORTED ON
FOUNDATION WALLS AND SPREAD FOOTINGS
6. GRAVITY LOADS
6A.SEE GRAVITY LOADS TABLE
6B.DRIFTING, SLIDING AND UNBALANCED SNOW
- GROUND SNOW LOAD = 95 PSF
- SNOW EXPOSURE FACTOR Ce = 1.0
- SNOW THERMAL FACTOR Ct = 1.0 (ROOFS)
- SNOW THERMAL FACTOR Ct = 1.2 (PATIOS, TRELLIS)
- SNOW LOAD IMPORTANCE FACTOR Is = 1.0
- TOWN OF VAIL FLAT ROOF SNOW LOAD Pf = 100 PSF
FOUNDATION NOTES
1. DESIGN CRITERIA:
1A.THE GEOTECHNICAL REPORT PREPARED BY HP GEOTECH, NUMBER 115 205A, DATED MAY 26,
2015 PROVIDED CRITERIA FOR THE FOUNDATION DESIGN FOR THE PROJECT.
2. FOOTINGS:
2A.FOOTING DESIGN CRITERIA:
- MAXIMUM TOTAL LOAD BEARING PRESSURE = 2500 PSF
- MINIMUM CONTINUOUS FOOTING WIDTH = 16 INCHES
- MINIMUM SPREAD FOOTING WIDTH = 24 INCHES
- ULTIMATE COEFFICIENT OF FRICTION TO RESIST LATERAL LOADS = 0.5
- FROST DEPTH TO BOTTOM OF FOUNDATION = 48 IN
3. FOUNDATION AND SITE RETAINING WALLS:
3A.EQUIVALENT FLUID PRESSURES USED FOR WALL DESIGN:
- "ACTIVE” CONDITION = 40 PCF
- "AT REST” CONDITION = 50 PCF
- "PASSIVE” CONDITION = 400 PCF
- LATERAL PRESSURE DUE TO SURCHARGE = 100 PSF
- ULTIMATE COEFFICIENT OF FRICTION TO RESIST LATERAL LOADS = 0.5
3B.WALL DESIGN BASED ON ON-SITE GRANULAR BACKFILL ADJACENT TO FOUNDATION WALLS.
DEFERRED SUBMITTALS
1
SUBMITTALS
1. GENERAL
1A.THE FOLLOWING ITEMS ARE REQUIRED TO BE SUBMITTED FOR REVIEW BY THE ARCHITECT
AND ENGINEER:
- CONCRETE MIX DESIGN
- CONCRETE REINFORCING SHOP DRAWINGS
- STRUCTURAL STEEL ERECTION AND FABRICATION DRAWINGS
- ELEVATOR SHOP DRAWINGS WITH LOADS IMPOSED ON THE PRIMARY STRUCTURE
- SIMPSON STRONGWALLS
1
DRAWING RELEASE NOTES
FND SET - DRAWINGS ARE RELEASED FOR CONCRETE FOUNDATION CONSTRUCTION ONLY
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
CONCRETE MIX TABLE NOTES:
PROPORTIONS OF MATERIALS IN CONCRETE MIX SHALL BE ESTABLISHED TO:
- PROVIDE THE MINIMUM COMPRESSIVE STRENGTH AS INDICATED IN THE MIX TABLE. DO NOT EXCEED THE
MAXIMUM WATER-CEMENT RATIO NOTED.
- PROVIDE WORKABILITY AND CONSISTENCY TO PERMIT CONCRETE TO BE WORKED READILY INTO FORMS
AND AROUND REINFORCEMENT UNDER CONDITIONS OF PLACEMENT TO BE EMPLOYED, WITHOUT
SEGREGATION OR EXCESSIVE BLEEDING. CONTRACTOR SHALL SELECT APPROPRIATE SLUMP. USE
ADMIXTURES AS REQUIRED TO OBTAIN DESIRED RESULTS.
USE TYPE I / II PORTLAND CEMENT UNLESS NOTED OTHERWISE. FOR CONCRETE MIXES USED ON FLOORS
MINIMUM CEMENTITIOUS CONTENT SHALL BE 540 POUNDS PER CUBIC YARD
FOR CONCRETE PLACED BY PUMPING PROVIDE CONCRETE MIX FLOWABILITY TO FACILITATE PUMPING.
ENTRAINED AIR MAY BE USED TO FACILITATE PUMPING SUBJECT TO THE PROVISIONS OF NOTE b BELOW.
a. FOR THE MAXIMUM COARSE AGGREGATE SIZE INDICATED, USE THE FOLLOWING AGGREGATE SIZE
NUMBERS PER ASTM C33:
3/8": #8 AGGREGATE
3/4”: #67 AGGREGATE
1”: #57 AGGREGATE
b. WHERE AIR CONTENT IS INDICATED IN THE MIX TABLE, PROVIDE AIR ENTRAINING ADMIXTURE. TOTAL AIR
CONTENT LIMITS INCLUDE BOTH ENTRAINED AND ENTRAPPED AIR +/- 1 1/2%. ‘NP’ IN COLUMN INDICATES
ADDITION OF ENTRAINED AIR IS NOT PERMITTED EXCEPT WHERE CONTRACTOR CAN DEMONSTRATE THAT
SLABS WITH ENTRAINED AIR WILL HAVE A FINISH ACCEPTABLE TO THE ARCHITECT WITHOUT BLISTERS. AIR
CONTENT NOTED IS BASED ON 3/4" AGGREGATE. IF 3/8” AGGREGATE IS USED, INCREASE AIR CONTENT BY 1
1/2%.
c. ABBREVIATIONS FOR OTHER REQUIREMENTS AS FOLLOWS:
AE = SEE ARCH FOR FINISH, COLOR AND MOCK UP REQUIREMENTS. USE ADMIXTURES TO INCREASE
CONCRETE WORKABILITY/SLUMP AS REQUIRED TO ACHIEVE REQUIRED FINISH.
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:40 PMS002
NOTES
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
CONCRETE NOTESGENERAL NOTES
1. GENERAL:
1A.ENGINEER: REFERENCES ON THE STRUCTURAL DRAWINGS TO ‘ENGINEER’ MEAN THE STRUCTURAL
ENGINEER OF RECORD. OTHER ENTITIES ARE SPECIFICALLY NOTED AS “CONTRACTOR’S ENGINEER”,
“MECHANICAL ENGINEER”, ETC.
1B.THESE NOTES SUPPLEMENT THE PLANS AND DETAILS, WHICH SHALL BE REFERENCED FOR ADDITIONAL
REQUIREMENTS.
1C.UNDERGROUND UTILITIES: LOCATE EXISTING UTILITIES AND NOTIFY ARCHITECT OF EXISTING UTILITIES OR
SUBGRADE CONDITIONS WHICH INTERFERE WITH WORK.
1D.THE OUTSIDE FACE OF WOOD FRAMED EXTERIOR WALLS ARE AT GRID UNLESS DIMENSIONED OTHERWISE.
2. EXISTING STRUCTURES:
2A.CONTRACT DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE DRAWINGS AND SITE OBSERVATION AS
PERMITTED BY ACCESS RESTRICTIONS DURING DESIGN.
2B.THE EXISTING STRUCTURE AND FOUNDATION SHALL BE DEMOLISHED IN ITS ENTIRETY BEFORE
CONSTRUCTING THE NEW STRUCTURE.
3. USE OF DRAWINGS:
3A.DO NOT SCALE DRAWINGS.
3B.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES AND SPECIFICATIONS, THE
MORE STRINGENT REQUIREMENTS SHALL GOVERN. DETAILS ON DRAWINGS TAKE PRECEDENCE OVER
GENERAL NOTES AND TYPICAL DETAILS. DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS.
WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE
ON THE PROJECT.
4. TEMPORARY CONDITIONS:
4A.THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS
RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE
RESULT OF THE CONTRACTOR’S CONSTRUCTION METHODS AND/OR SEQUENCES. REFER TO “LATERAL LOAD
RESISTING SYSTEM DESCRIPTION” IN DESIGN CRITERIA FOR ADDITIONAL INFORMATION.
4B.FOUNDATION WALLS SHALL NOT BE BACKFILLED UNTIL THE SLABS-ON-GRADE AND UPPER DIAPHRAGMS
ARE IN-PLACE AND REACH FULL STRENGTH UNLESS ADEQUATE BRACING IS PROVIDED. USE ONLY HAND
OPERATED TOOLS FOR COMPACTION ADJACENT TO FOUNDATION WALLS AND GRADE BEAMS. GRADE BEAMS
SHALL BE BACKFILLED EVENLY ON BOTH SIDES.
5. SUBMITTALS AND SUBSTITUTIONS:
5A.SUBMITTALS: REFER TO SUMBITTAL NOTES FOR DETAILED REQUIREMENTS.
- IF THE CONTRACTOR REQUESTS A CHANGE FROM THE STRUCTURAL DRAWINGS, IT SHALL BE APPROVED
BY THE ARCHITECT AND DESIGNED BY MARTIN/MARTIN, INC. PRIOR TO SUBMITTING SHOP DRAWINGS.
VARIATION SHALL BE INDICATED ON THE SHOP DRAWINGS. CONTRACTOR SHALL COMPENSATE
MARTIN/MARTIN, INC. FOR MAKING THE CHANGE.
- CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR USE IN SUBMITTALS
- ALL SHOP DRAWINGS SHALL REFERENCE THE STRUCTURAL DRAWING NUMBER AND DETAIL USED TO
PREPARE THE SUBMITTAL
5B.SUBSTITUTIONS: ARCHITECTS APPROVAL SHALL BE SECURED FOR ALL SUBSTITUTIONS
5C.NONCONFORMANCE: NOTIFY ARCHITECT OF CONDITIONS NOT CONSTRUCTED PER THE CONTRACT
DOCUMENTS PRIOR TO PROCEEDING WITH CORRECTIVE WORK. SUBMIT PROPOSED REPAIR TO THE
ARCHITECT FOR ACCEPTANCE. CONTRACTOR SHALL COMPENSATE MARTIN/MARTIN, INC. FOR DESIGNING THE
REPAIR.
6. OSHA STANDARDS:
6A.THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. NOTHING SHOWN ON THE
STRUCTURAL DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED FOR THE CONTRACTOR TO
COMPLY WITH ALL OSHA REQUIREMENTS.
6B.THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, ANCHOR BOLTS, PLATES, STIFFENER PLATES,
STABILIZER PLATES, BRIDGING, BRACING, BEARING SEATS, COLUMN SPLICES, ETC., AS WELL AS CLOSURES
FOR OPENINGS. IN ADDITION, FIELD WELD ANYTHING THAT MAY BE CONSIDERED A TRIP HAZARD, SUCH AS
SHEAR STUDS, AFTER PROTECTIVE DECKING IS INSTALLED.
6C.WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE
STRUCTURAL DRAWINGS REPRESENT FINAL CONDITIONS ONLY. THE CONTRACTOR SHALL ADD ALL ERECTION
FRAMING NECESSARY TO COMPLY WITH OSHA.
7. CONSTRUCTION ENGINEERING:
7A.THE STRUCTURE DEFINED ON THE CONTRACT DOCUMENTS HAS BEEN DESIGNED ONLY FOR LOADS
ANTICIPATED ON THE STRUCTURE DURING ITS SERVICE LIFE. PROVIDE ALL REQUIRED ENGINEERING AND
OTHER MEASURES TO ACHIEVE THE MEANS, METHODS, AND SEQUENCES OF WORK. SUCH ENGINEERING MAY
INCLUDE, BUT IS NOT LIMITED TO:
- LAYOUT
- DESIGN FOR FORMWORK
- DESIGN OF CONCRETE MIXES
- ERECTION PROCEDURES WHICH ADDRESS STABILITY OF THE FRAME DURING CONSTRUCTION
- WELD PROCEDURES
- DESIGN OF TEMPORARY BRACING OF WALLS FOR WIND, SEISMIC, OR SOIL LOADS
- SURVEYING TO VERIFY CONSTRUCTION TOLERANCES
- EVALUATION OF TEMPORARY CONSTRUCTION LOADS ON STRUCTURE DUE TO EQUIPMENT AND MATERIALS
- STRUCTURAL ENGINEERING TO RESIST ANY OTHER LOADS NOT IDENTIFIED ON DESIGN DRAWINGS
8. COORDINATION:
8A.STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN
CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER
DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS
INTO SHOP DRAWINGS AND WORK.
8B.COORDINATE DIMENSIONS OF ALL OPENINGS, BLOCKOUTS, DEPRESSIONS, ETC., WITH ARCHITECTURAL
DRAWINGS, DRAWINGS FROM OTHER DISCIPLINES, AND FIELD CONDITIONS PRIOR TO SHOP DRAWING
SUBMITTAL.
8C.SEE ARCHITECTURAL PLANS FOR INTERIOR PARTITIONS.
1. GENERAL:
1A.ALL WORK SHALL CONFORM WITH ACI 301, LATEST EDITION, UNLESS NOTED OTHERWISE IN
DRAWINGS.
1B.DETAIL BARS IN ACCORDANCE WITH THE LATEST EDITIONS OF PUBLICATION SP-66: “ACI DETAILING
MANUAL” WITH ADDED REQUIREMENTS OF THE PROJECT SPECIFICATION AND ACI 318: “BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE.”
2. REINFORCING MATERIALS:
2A.SEE ‘REINFORCING MATERIALS TABLE’
3. REINFORCING FABRICATION:
3A.SPLICES:
- NO SPLICING OF REINFORCEMENT PERMITTED EXCEPT AS NOTED ON DRAWINGS. MAKE BARS
CONTINUOUS AROUND CORNERS. WHERE PERMITTED, SPLICES MAY BE MADE BY CONTACT LAPS OR
MECHANICAL CONNECTORS.
- SEE ‘LAP SPLICE SCHEDULE’ FOR LAP LENGTHS.
- SPLICE CONTINUOUS TOP AND BOTTOM BARS IN WALLS, BEAMS, AND GRADE BEAMS ‘LTS’ UNLESS
NOTED OTHERWISE.
3B.MISCELLANEOUS REINFORCING REQUIREMENTS:
- PROVIDE ADDITIONAL BARS OR STIRRUPS REQUIRED TO SECURE REINFORCING IN PLACE DURING
CONCRETE PLACEMENT.
- MAKE ALL REINFORCING BAR BENDS IN THE FABRICATOR’S SHOP UNLESS NOTED.
- NO WELDING OF REINFORCING PERMITTED UNLESS NOTED ON DRAWINGS. WHERE PERMITTED,
PERFORM WELDING IN ACCORDANCE WITH AWS D1.4, LATEST EDITION.
- PROVIDE ADDED REINFORCING TO TRIM ALL OPENINGS, NOTCHES, AND REENTRANT CORNERS AS
NOTED IN TYPICAL DETAILS.
4. STRUCTURAL CONCRETE MIX REQUIREMENTS:
4A.SEE ‘CONCRETE MIX TABLE’
5. SLAB-ON-GRADE:
5A.VERIFY ALKALINITY OF CONCRETE SURFACE, SLAB VAPOR TRANSMISSION, AND SLAB
FLATNESS/LEVELNESS ARE COMPATIBLE WITH FLOORING SYSTEM AND ADHESIVES PRIOR TO
INSTALLING FLOORING.
5B.TAKE PRECAUTIONS TO MINIMIZE SLAB CURLING. GRIND SLAB OR USE LEVELING COMPOUND IF
FLOOR FLATNESS AND LEVELNESS VALUES ARE NOT ACCEPTABLE TO THE ARCHITECT.
6. NON-SHRINK GROUT:
6A.CONFORM TO ASTM C1107.
6B.ACHIEVE 6000 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
7. PLACING REINFORCEMENT:
7A.REINFORCEMENT PROTECTION:
- SEE ‘CONCRETE COVER TABLE’
- SEE ACI 318-11 7.5 FOR REINFORCEMENT PLACING TOLERANCES AND ACI 117 FOR ADDITIONAL
REQUIREMENTS
7B.PROVIDE ACCESSORIES NECESSARY TO PROPERLY SUPPORT REINFORCING AND WELDED WIRE
REINFORCEMENT AT POSITIONS SHOWN ON PLANS. ALL REINFORCING, DOWELS, BOLTS, AND
EMBEDDED PLATES SHALL BE SET AND TIED IN PLACE BEFORE THE CONCRETE IS POURED.
“STABBING” INTO PREVIOUSLY PLACED CONCRETE IS NOT PERMITTED.
8. CONSTRUCTION/CONTROL JOINTS:
8A.SUBMIT DRAWINGS SHOWING CONSTRUCTION AND CONTROL JOINT LOCATIONS ALONG WITH THE
SEQUENCE OF POURS. CONSTRUCTION JOINT LOCATIONS AND CASTING SEQUENCE SHALL BE
ARRANGED TO MINIMIZE THE EFFECTS OF ELASTIC AND LONG-TERM SHORTENING/SHRINKAGE.
8B.CONSTRUCTION JOINTS IN SLABS-ON-GRADE SHALL BE LOCATED TO ACCOMMODATE THE
MAXIMUM LENGTH AND AREA THE CONTRACTOR CAN REASONABLY POUR, FINISH, AND JOINT IN THE
SAME DAY.
9. MEP AND OTHER OPENINGS AND EMBEDMENTS:
9A.PROVIDE SLEEVES AT OPENINGS (SUCH AS THOSE REQUIRED FOR PLUMBING AND ELECTRICAL
PENETRATIONS) BEFORE PLACING CONCRETE. DO NOT CUT REINFORCING WHICH MAY CONFLICT.
CORING OF CONCRETE IS NOT PERMITTED.
9B.REFER TO TYPICAL DETAILS FOR SPACING LIMITS ON SLEEVES AND FOR REQUIREMENTS FOR
EMBEDDED CONDUIT AND PIPE.
CONCRETE MIX TABLE
CONC MIX TYPEINTENDED USE 28 DAY STRENGTH, f'c (KSI)CONCRETE WEIGHTMAX W/C RATIO, INCLUDING FLY ASHMAX AGGREGATE SIZE (IN), NOTE aTOTAL AIR CONTENT (%), NOTE bOTHER REQUIREMENTS, NOTE c1 FOOTINGS 3 NWC -- 1 -- --
2 GRADE BMS, FND
WALLS
4.5 NWC 0.45 3/4 5 --
3 ALL CONC EXPOSED TO
WEATHER OR DEICERS:
SITE WALLS
5 NWC 0.40 3/4 6 --
4 INT SLABS ON GRADE 3.5 NWC 0.50 3/4 NP --
5 ARCHITECTURALLY
EXPOSED CONC
CHIMNEY
4.5 NWC 0.45 3/8 6 AE
REINFORCING MATERIAL TABLE
REINF ELEMENT ASTM Fy (KSI) Fu (KSI)
TYP REINFORCING A615 60 90
WELDED & FIELD BENT REINF A706 60 80
WELDED WIRE REINFORCING, SMOOTH A185 65 75
STEEL MATERIAL TABLE
STEEL ELEMENT ASTM/TYPE Fy (KSI)
Fu
(KSI)COMMENTS
ANCHOR RODS F1554 GR 55 55 75 WELDABLE, HEAVY HEX
HEADED
BOLTS A325 OR F1852 -- 120 BOLTS ARE 3/4"Ø UNO, USE
TENSION-CONTROLLED
WHERE POSSIBLE
DAS A496 70 80 --
HAS A108 51 65 STUDS ARE 3/4"Ø UNO
OTHER SHAPES A36 36 58 --
PLATES A36 36 58 --
RECT HSS A500 GR C 50 62 --
WELDING ELECTRODES E70 PER AWS
WF, WT A992 50 65 --
ANCHOR TYPE
POST-INSTALLED ANCHOR TABLE
PRODUCT
ADHESIVE
(IN CONCRETE)
HILTI HIT-HY 200
ADHESIVE ANCHOR
RODS
SCREW ANCHORS
EXPANSION ANCHORS
(IN CONCRETE)
--
HILTI KWIK BOLT TZ
HILTI KWIK HUS-EZ
Fy (KSI) COMMENTS
--
36
MIN
--
Fu (KSI)
--
58
MIN
--
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
-- --
THREADED ROD,
UNGREASED
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ADHESIVE
(IN CONCRETE W/>12"
EMBEDMENT)
HILTI HIT-RE 500 SD -- -- SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
STEEL NOTES
1. CONNECTIONS:
1A.PROVIDE CONNECTIONS AS SHOWN IN THE DETAILS HEREIN.
2. WELDING REQUIREMENTS:
2A.WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE AWS.
QUALIFICATION TESTS.
2B.MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN 3/16” FILLET, CONTINUOUS UNLESS OTHERWISE
NOTED.
2C.WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED.
INCREASE WELD SIZE IF GAPS EXIST AT THE FAYING SURFACE.
2D.WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY ANSI/AISC 360-10 TABLES
J2.3 AND J2.4.
2E.ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED.
2F.FIELD WELDING SYMBOLS INDICATE SUGGESTED CONSTRUCTION PROCEDURES.
3. STRUCTURAL STEEL INSTALLATION:
3A.ALL HIGH STRENGTH BOLTS WHERE NOTED ON THE DRAWINGS AS TYPE “SC” OR OTHER TYPE
FOLLOWED BY “PT”, SHALL BE TENSIONED TO THE VALUES OF TABLE J3.1 OF ANSI/AISC 360-10 . OTHER
HIGH-STRENGTH BOLTS MAY BE INSTALLED SNUG TIGHT AS DEFINED BY AISC.
WOOD NOTES
1. LAMINATED MEMBER SIZES:
1A.LVL, PSL, LSL, GLU-LAM AND AND OTHER FABRICATED MEMBERS (TJI) SIZES SHOWN ARE NET. OTHER
MEMBER SIZES ARE NOMINAL.
2. FRAMING LUMBER:
2A.DRY (19% MAXIMUM MOISTURE CONTENT AT THE TIME OF INSTALLATION), DOUGLAS FIR-LARCH WITH
MINIMUM DESIGN VALUES BASED ON THE 2012 NDS. SEE ‘FRAMING LUMBER TABLE’ FOR MINIMUM GRADES.
2B.BEAMS AND STRINGERS USED WITH CANTILEVERS OR CONTINUOUS SPANS SHALL BE GRADED TO
PROVIDE THE SPECIFIED ALLOWABLE STRESSES OVER THE ENTIRE MEMBER LENGTH.
3. FABRICATED LUMBER:
3A.FABRICATED LUMBER DESIGNATIONS ARE THOSE MANUFACTURED BY WEYERHAEUSER.
3B.FABRICATED LUMBER IS DESIGNATED ON THE DRAWINGS AS ONE OF THE FOLLOWING: TJI JOISTS,
MICROLLAM (LVL), PARALLAM (PSL), TIMBERSTRAND (LSL) OR RIMBOARD.
3C.THE MANUFACTURER SHALL PROVIDE WEB STIFFENERS ON I-JOISTS, END BLOCKING, BRIDGING, AND
ERECTION BRACING AS REQUIRED. SEE “DESIGN CRITERIA” FOR DESIGN DEAD AND LIVE LOADS.
3D.FABRICATED LUMBER SHALL BE DRY.
3E.SEE ‘FABRICATED LUMBER TABLE’ FOR MINIMUM PROPERTIES (AT NORMAL LOAD DURATIONS).
3F.FABRICATED RIMBOARD SHALL BE LAMINATED STRAND LUMBER.
3G.SEE ‘RIMBOARD TABLE’ FOR MINIMUM PROPERTIES.
5. SHEATHING:
5A.WOOD STRUCTURAL PANELS (WSP)
- WOOD STRUCTURAL PANELS SHALL BE APA RATED SHEATHING CONFORMING TO U.S. DEPARTMENT OF
COMMERCE STANDARD PS-2 AND APA PERFORMANCE STANDARD PRP-108, LATEST EDITIONS.
- ALL WOOD PANELS SHALL BE EXPOSURE 1.
6. BLOCKING AND BRIDGING:
6A.PROVIDE FULL HEIGHT SOLID BLOCKING (MINIMUM WIDTH TO MATCH WIDTH OF FRAMING) BETWEEN ALL
FRAMING MEMBERS (SOLID SAWN JOISTS AND RAFTERS, FABRICATED JOISTS AND RAFTERS AND TRUSSES)
AT SUPPORTS.
7. NAILING:
7A.UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE BOX NAILS COMMON NAILS WITH SIZES SHOWN
IN THE TABLE BELOW. MINIMUM NAILING SHALL BE IN ACCORDANCE WITH THE TYPICAL WOOD CONNECTION
SCHEDULE AND IBC 2012 TABLE 2304.9.1.
7B.WHERE COMMON NAILS ARE SPECIFIED, BOX NAILS OF EQUAL LENGTH MAY BE SUBSTITUTED PROVIDED
ONE BOX NAIL IS ADDED FOR EVERY THREE COMMON NAILS SPECIFIED.
8. METAL CONNECTORS:
8A.FRAMING CONNECTORS SHALL CONFORM TO IBC 2012 SECTION 1711.1. FRAMING CONNECTOR
DESIGNATIONS ARE THOSE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, SAN LEANDRO,
CALIFORNIA. OTHER MANUFACTURER’S PRODUCTS MAY BE USED IF APPROVED BY THE ENGINEER. FURNISH
NAILS AND/OR BOLTS OF DIAMETER, LENGTH, AND NUMBER SPECIFIED BY THE MANUFACTURER FOR EACH
CONNECTOR.
8B.ALL CONNECTOR HOLES SHALL BE FILLED WITH PROPER NAILS/BOLTS INCLUDING OPTIONAL NAIL
LOCATIONS FOR UPLIFT. ALL BOLT HOLES SHALL BE DRILLED INTO FRAMING MEMBERS. MAXIMUM HOLE
DIAMETER IS 1/16” LARGER THAN THE BOLT DIAMETER.
9. OPENINGS:
9A.OPENING, POCKETS, ETC., SHALL NOT BE PLACED IN BEAMS, JOISTS, RAFTERS, STUDS, POSTS, COLUMNS,
TIMBER AND OTHER STRUCTURAL MEMBERS UNLESS DETAILED ON THE STRUCTURAL DRAWINGS.
PRODUCT
FABRICATED LUMBER TABLE
DEPTH
11 7/8"
TYPE
MR
(FT-
LB)
11 7/8" TJI-210
VR
(LBS)
EI (x10
^6 in^
2-lbs)
3 1/2" END
REACTION
(LBS)
INTERMEDIATE
REACTION
(LBS)REMARKS
TYPE OF USE
LSL FRAMING LUMBER SCHEDULE
GRADE
EXTERIOR STUDS 1.3E
LOAD BEARING STUDS (AND COLUMNS
ASSEMBLED FROM STUDS)
NON-LOAD BEARING STUDS
ROOF JOIST & RAFTERS
BEAMS & STRINGERS
FLOOR-JOIST
EXPOSED FRAMING
DECKING
POSTS & TIMBER
LSL MEMBERS DEEPER THAN 5 1/2"
Fb (PSI) Fv (PSI) E (PSI)
1,700 425 1,300,000
I-JOIST 3,795 1,655 315 1,655 2,505 --
11 7/8"11 7/8" TJI-360 I-JOIST 6,180 1,705 419 1,705 2,815 --
11 7/8"11 7/8" TJI-560 I-JOIST 9,500 2,050 636 2,050 3,475 --
1.3E 425 1,300,000
1.3E 425 1,300,000
1.3E 425 1,300,000
1.3E 425 1,300,000
1.3E 425 1,300,000
1.3E 425 1,300,000
1.3E 425 1,300,000
1.3E 425 1,300,000
1.5E 2,250 505 1,500,000
9 1/2"5 1/4" PSL BEAM 19,585 9,645 750 -- -- --
11 7/8"5 1/4" PSL BEAM 29,855 12,055 1,466 -- -- --
16"5 1/4" PSL BEAM 52,430 16,240 3,584 -- -- --
1,700
1,700
1,700
1,700
1,700
1,700
1,700
1,700
5 1/4"5 1/4" PSL GIRT 5507 4,226 76 -- -- --
14"14" TJI-360 I-JOIST 7,335 1,955 612 1,865 2,815 --
5 1/2"5 1/2" LVL BEAM 2,125 1,830 48 3,828 --
7 1/4"7 1/4" LVL BEAM 3,555 2,410 112 --
9 1/2"9 1/2" LVL BEAM 5,885 3,160 250 --
11 7/8"11 7/8" LVL BEAM 8,925 3,950 488 --
3,828
3,828
3,828
3,828
3,828
3,828
3,828
1
1
1
1
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS AND TESTING
QUALITY ASSURANCE GENERAL NOTES
1. GENERAL:
1A.SCOPE OF WORK
- MARTIN/MARTIN RECOMMENDS THAT THE OWNER SHALL ENGAGE A QUALIFIED INSPECTION AND TESTING AGENCY(S)
TO PERFORM SPECIAL INSPECTIONS AND TESTING FOR ALL STRUCTURAL MEMBERS AND ASSEMBLIES AS NOTED HEREIN.
- SPECIAL INSPECTIONS ARE IN ADDITION TO INSPECTIONS BY THE AUTHORITY HAVING JURISDICTION REQUIRED BY IBC
2012 SECTION 110.
- REFER TO THE SPECIFICATIONS FOR REPORTING AND PROCEDURAL REQUIREMENTS FOR QUALITY ASSURANCE AND
QUALITY CONTROL.
- REFER TO ARCH/MECH/ELEC/CIVIL SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL SPECIAL INSPECTION AND TESTING
THAT MAY BE REQUIRED.
- SPECIAL INSPECTIONS AND TESTING ARE APPLICABLE TO ALL REVISIONS AND/OR FUTURE WORK ADDED BY
AMENDMENTS TO THESE DOCUMENTS.
1B.DEFINITIONS
- SPECIAL INSPECTOR: THE AGENCY ENGAGED BY THE OWNER AND APPROVED BY THE AUTHORITY HAVING JURISDICTION
TO ACT AS THE DESIGNATED REPRESENTATIVE TO PERFORM INSPECTIONS.
- SPECIAL INSPECTION: INSPECTION PERFORMED BY THE SPECIAL INSPECTOR ACCORDING TO IBC 2012 SECTION 1704 TO
ENSURE COMPLIANCE WITH APPROVED CONSTRUCTION DOCUMENTS AND REFERENCED STANDARDS.
- (P) PERIODIC INSPECTION: THE PART-TIME OR INTERMITTENT OBSERVATION BY THE SPECIAL INSPECTOR OF WORK
BEING PERFORMED. SPECIAL INSPECTOR SHALL BE PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED.
OBSERVATION OF ALL WORK (100% VISUAL) SHALL BE MADE AT THE COMPLETION OF THE WORK.
- (C) CONTINUOUS INSPECTION: THE FULL-TIME OBSERVATION BY THE SPECIAL INSPECTOR OF WORK BEING PERFORMED.
SPECIAL INSPECTOR SHALL BE PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED. OBSERVATION OF ALL
WORK (100% VISUAL) SHALL BE MADE AT THE COMPLETION OF THE WORK.
1C.DEFICIENCIES IN WORK
- CORRECT DEFICIENCIES IN WORK THAT TESTS AND INSPECTIONS INDICATE DO NOT COMPLY WITH THE CONTRACT
DOCUMENTS AND REFERENCED STANDARDS.
- ALL COST OF ADDITIONAL TESTING AND/OR INSPECTIONS FOR CORRECTIVE WORK SHALL BE BORNE BY THE
CONTRACTOR.
2. SHOP FABRICATIONS:
2A.GENERAL
- PERFORM INSPECTIONS AND TESTING FOR ALL SHOP FABRICATED STRUCTURAL MEMBERS AND ASSEMBLIES AS
NOTED HEREIN. SPECIAL INSPECTOR SHALL PERFORM SPECIAL INSPECTIONS AND TESTING UNLESS THE FABRICATOR IS
REGISTERED AND APPROVED BY THE AUTHORITY HAVING JURISDICTION TO PERFORM SUCH WORK WITHOUT SPECIAL
INSPECTION OR FABRICATION HAS A CURRENT ICC-ES EVALUATION REPORT.
- SPECIAL INSPECTOR SHALL VERIFY THE FABRICATOR MAINTAINS AND FOLLOWS DETAILED SHOP FABRICATION AND
QUALITY CONTROL PROCEDURES, UNLESS FABRICATOR IS REGISTERED AND APPROVED.
- AT THE COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO
THE AUTHORITY HAVING JURISDICTION ACCORDING TO IBC 2012 SECTION 1704.2.5.2.
- APPROVED FABRICATORS MAY PERFORM TESTING NOTED HEREIN EXCEPT THAT NONDESTRUCTIVE TESTING (NDT)
SHALL ONLY BE PERFORMED BY PERSONNEL WITH QUALIFICATIONS THAT MEET OR EXCEED THE CRITERIA OF AWS D1.1
SUBCLAUSE 6.14.6 AND AMERICAN SOCIETY FOR NONDESTRUCTIVE TESTING (ASNT) SNT-TC-1A OR ASNT CP-189.
2B.SHOP FABRICATIONS INCLUDED
- SHOP FABRICATED STRUCTURAL STEEL INCLUDING STAIRS AND RAILING ELEMENTS
- PRE-FABRICATED WOOD STRUCTURAL ELEMENTS
- SHOP FABRICATED STEEL CONNECTIONS FOR STRUCTURAL WOOD CONNECTIONS
1
ITEM FREQUENCY STANDARD
SUBGRADE
CRITERIA
- EXCAVATION P VERIFY EXCAVATIONS ARE EXTENDED TO
THE PROPER DEPTH AND HAVE REACHED
THE PROPER BEARING MATERIAL
--
SOILS SPECIAL INSPECTIONS
- BEARING MATERIAL P VERIFY BEARING MATERIAL IS ADEQUATE TO
ACHIEVE THE DESIGN BEARING CAPACITY
SOILS REPORT
CONTROLLED FILL
- PLACEMENT C VERIFY USE OF PROPER MATERIALS, DENSITIES,
COMPACTION, AND LIFT THICKNESSES
--
- PRIOR TO PLACEMENT P VERIFY SUBGRADE HAS BEEN PROPERLY
PREPARED
--
SOILS SPECIAL INSPECTION NOTES:
1. SEE CIVIL DRAWINGS AND/OR SPECIFICATIONS FOR ADDITIONAL EARTHWORK AND UTILITY INSPECTION REQUIREMENTS.
2. SEE CIVIL DRAWINGS AND/OR SPECIFICATIONS FOR CLASSIFICATION AND TESTING REQUIREMENTS FOR COMPACTED FILL
AND/OR CONTROLLED LOW-STRENGTH MATERIAL.
ITEM FREQUENCY STANDARD
REINFORCING STEEL
CRITERIA
- DURING PLACEMENT P VERIFY GRADE, FINISH, SIZE, BAR QUANTITY,
LOCATION, SPACING, COVER, HOOK LENGTHS,
SPLICE LENGTH, SPLICE LOCATIONS, BEND
DIAMETERS, COATING, SURFACE CONDITION,
AND SUPPORT.
ACI 318 3.5,7.1-7.7
- WELDING C VERIFY ASTM A706 REINFORCING STEEL.AWS D1.4
- FIELD BENDING P --ACI 301 3.3.2.8
BOLTS AND EMBEDMENTS
CONCRETE
- MIX DESIGN EACH
TRUCK
VERIFY USE OF APPROVED DESIGN MIXTURE FOR
EACH TRUCK LOAD
--
- PLACEMENT OF CONCRETE C ACI 318 5.9-5.10
- CURING P ACI 318 5.11-5.13
STRUCTURAL CONCRETE SPECIAL INSPECTIONS
- PRIOR TO PLACEMENT OF
CONCRETE
100% VERIFY TYPE, FINISH, DIAMETER, LENGTH,
QUANTITY, EMBEDMENT LENGTH, SPACING AND
EDGE DISTANCES. VERIFY USE OF PLACING
TEMPLATE WHERE SPECIFIED.
--
- WELDING -- INSPECT PER THE STRUCTURAL STEEL TABLE
--
- FORMWORK PRIOR TO
PLACEMENT OF CONCRETE
P INSPECT FIRST POUR OF EACH TYPE (GRADE
BEAM, COLUMN, STRUCTURAL SLAB, SLAB-ON-
DECK, ETC.)
ACI 318 6.1.1
- PRIOR TO PLACEMENT OF
CONCRETE
100%
--
--
ITEM FREQUENCY STANDARD
REINFORCING STEEL, BOLTS
AND EMBEDMENTS
CRITERIA
- WELDING -- PER STRUCTURAL STEEL TESTING--
CONCRETE
- AIR CONTENT WHEN AIR
ENTRAINMENT IS SPECIFIED
EACH
COMPOSITE
SAMPLE
--ASTM C231 PRESSURE
METHOD
STRUCTURAL CONCRETE TESTING
- COMPOSITE SAMPLE OBTAIN AT POINT OF PLACEMENT. FOR DRILLED
PIERS OBTAIN NEAR BEGINNING OF LOAD PRIOR
TO PLACEMENT IN SHAFT. ADJUST FREQUENCY
AS REQUIRED TO PROVIDE MINIMUM 5 TOTAL
TESTS PER MIX BUT NOT MORE THAN ONE
SAMPLE PER TRUCK LOAD.
ASTM C172
- SLUMP EACH
COMPOSITE
SAMPLE
SPECIFIED SLUMP SHALL BE AS SUMBITTED IN
THE MIX DESIGN ± 1 1/2". PERFORM ADDITIONAL
TESTS WHEN CONCRETE CONSISTENCY
APPEARS TO CHANGE.
ASTM C143
1. f'c < 5000 PSI 100 CY/MIX/DAY
- TEMPERATURE EACH
COMPOSITE
SAMPLE AND 60
MINUTE
INTERVALS
REQUIRED WHEN AIR TEMPERATURE IS 40 °F
AND BELOW OR 80°F AND ABOVE.
ASTM C1064
- COLD WEATHER CURING -- RECORD MAXIMUM AND MINIMUM CONCRETE
TEMPERATURE DURING CURING PERIOD, WHEN
DAILY AVERAGE AIR TEMPERATURE OF 40 °F OR
BELOW IS EXPECTED FOR 3 SUCCESSIVE DAYS
DURING CURING PERIOD.
ASTM C1074
- COMPRESSIVE STRENGTH EACH
COMPOSITE
SAMPLE
TEST ONE CYLINDER SPECIMEN AT 7 DAYS AND
TWO CYLINDER SPECIMENS AT 28 DAYS. IF
DESIGN STRENGTH IS NOT ACHIEVED AT 28
DAYS, TEST REMAINING CYLINDER AT 56 DAYS.
ACCEPTANCE CRITERIA PER ACI 318.
ASTM C31 (6x12
SPECIMENS)
AND ASTM C39
STRUCTURAL CONCRETE TESTING NOTES:
1. NONDESTRUCTIVE TESTING MAY BE PERMITTED BY THE ARCHITECT, BUT WILL NOT BE USED AS SOLE BASIS FOR
APPROVAL OR REJECTION OF DEFICIENT CONCRETE.
2. REPORTS OF COMPRESSIVE STRENGTH TESTS SHALL CONTAIN THE FOLLOWING INFORMATION: DATE OF CONCRETE
PLACEMENT, LOCATION OF CONCRETE BATCH IN WORK, DESIGN 28-DAY COMPRESSIVE STRENGTH, CONCRETE SUPPLIER
AND MIXTURE ID NUMBER, TIME OF BATCH AND PLACEMENT, AMBIENT AIR TEMPERATURE, SITE ADDED WATER AND
ADMIXTURES, UNIT WEIGHT, AND AS REQUIRED BY ASTM C39.
ITEM FREQUENCY STANDARD
EXPANSION ANCHORS, SLEEVE
ANCHORS, SCREW ANCHORS
CRITERIA
- PRIOR TO INSTALLATION OF
ANCHOR
EACH
ANCHOR
VERIFY TYPE, DIAMETER, LENGTH, FINISH, AND
BASE MATERIAL. VERIFY MAXIMUM IMPACT
WRENCH TORQUE RATING FOR SCREW
ANCHORS.
ICC-ES REPORT
POST-INSTALLED ANCHORS/REINFORCING STEEL SPECIAL INSPECTIONS
ADHESIVE ANCHORS,
REINFORCING STEEL ANCHORED
INTO HARDENED CONCRETE
- DURING INSTALLATION OF
ANCHOR
C CONTINUOUS INSPECTION REQUIRED
REGARDLESS IF PERIODIC INSPECTION IS
PERMITTED BY ICC-ES REPORT. VERIFY HOLE
DIMENSIONS, HOLE CLEANING, ANCHOR
EMBEDMENT, EDGE DISTANCES AND SPACING.
ICC-ES REPORT
- AFTER INSTALLATION OF
ATTACHED ASSEMBLY
100% VISUAL VERIFY NUMBER, EDGE DISTANCES, AND ANCHOR
FLUSH WITH AND PERPENDICULAR TO THE
RECEIVING SURFACE.
--
- PRIOR TO INSTALLATION OF
ANCHOR
EACH
ANCHOR
VERIFY TYPE, DIAMETER, LENGTH, FINISH, AND
BASE MATERIAL.
ICC-ES REPORT
- DURING INSTALLATION OF
ANCHOR
C CONTINUOUS INSPECTION REQUIRED
REGARDLESS IF PERIODIC INSPECTION IS
PERMITTED BY ICC-ES REPORT. VERIFY HOLE
DIMENSIONS, HOLE CLEANING, ANCHOR
EMBEDMENT, EDGE DISTANCES AND SPACING.
ICC-ES REPORT
- AFTER INSTALLATION OF
ATTACHED ASSEMBLY
100% VISUAL VERIFY NUMBER, EDGE DISTANCES, AND ANCHOR
FLUSH WITH AND PERPENDICULAR TO THE
RECEIVING SURFACE.
--
- PRIOR TO START OF WORK -- REVIEW CONTRACTOR'S INSTALLATION
PROCEDURE.
ICC-ES REPORT
- PRIOR TO START OF WORK -- REVIEW CONTRACTOR'S INSTALLATION
PROCEDURE.
ICC-ES REPORT
- CURE TIME 100% VISUAL VERIFY FULL CURE TIME HAS ELAPSED PRIOR TO
APPLICATION OF TORQUE OR LOAD TO ANCHOR.
--
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:41 PMS003
QUALITY ASSURANCE
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
STRUCTURAL STEEL INSPECTIONS
ITEM INSPECTION TASK STANDARD CRITERIA/REMARKS
PRIOR TO WELDING
REVIEW WELDING
PROCEDURE
SPECIFICATIONS
PERFORM AISC 360, CHAPTER N
FIT UP OF WELDS,
INCLUDING JOINT
GEOMETRY, AND
CONFIGURATIONS
OBSERVE AISC 360, CHAPTER N
MATERIAL IDENTIFICATION OBSERVE AISC 360, CHAPTER N
WELDER IDENTIFICATION
SYSTEM
OBSERVE AISC 360, CHAPTER N
DURING WELDING
USE OF QUALIFIED
WELDERS
OBSERVE AISC 360, CHAPTER N
CONTROL AND HANDLING
OF WELDING
CONSUMABLES
OBSERVE AISC 360, CHAPTER N
NO WELDING OVER
CRACKED TACK WELDS
OBSERVE AISC 360, CHAPTER N
ENVIRONMENTAL
CONDITIONS, AND WPS
FOLLOWED
OBSERVE AISC 360, CHAPTER N
WELDING TECHNIQUES -
SINGLE PASS WELDS
OBSERVE AISC 360, CHAPTER N
WELDING TECHNIQUES -
MULTI-PASS WELDS
OBSERVE AISC 360, CHAPTER N
AFTER WELDING
WELDS CLEANED OBSERVE AISC 360, CHAPTER N
SIZE, LENGTH, AND
LOCATION OF WELDS
PERFORM AISC 360, CHAPTER N
WELDS MEET VISUAL
ACCEPTANCE CRITERIA
PERFORM AISC 360, CHAPTER N,
AWS D1.1
WHERE INSPECTOR OBSERVES
QUESTIONABLE WELDS,
NON-DESTRUCTIVE TESTING SHALL
BE PERFORMED
ARC STRIKES PERFORM AISC 360, CHAPTER N
K-AREA PERFORM AISC 360, CHAPTER N
REPAIR ACTIVITIES PERFORM AISC 360, CHAPTER N
DOCUMENT ACCEPTANCE
OR REJECTION OF
WELDED MEMBER OR
JOINT
PERFORM AISC 360, CHAPTER N
PRIOR TO BOLTING
PROPER FASTENERS AND
BOLTING PROCEDURE
SELECTED FOR JOINT
DETAIL
OBSERVE AISC 360, CHAPTER N
CONNECTING ELEMENTS
MEET REQUIREMENTS,
INCLUDING HOLE
PREPARATION AND
FAYING SURFACE
OBSERVE AISC 360, CHAPTER N
PRE-INSTALLATION
VERIFICATION TESTING
OBSERVE AISC 360, CHAPTER N NOT APPLICABLE FOR SNUG TIGHT
JOINTS
PROPER STORAGE FOR
FASTENER COMPONENTS
OBSERVE AISC 360, CHAPTER N
DURING BOLTING
FASTENERS PLACED IN
ALL HOLES AND
POSITIONED AS
REQUIRED
OBSERVE AISC 360, CHAPTER N
AFTER BOLTING
DOCUMENT ACCEPTANCE
OR REJECTION OF
BOLTED CONNECTIONS
PERFORM DOCUMENT
ACCEPTANCE OR
REJECTION OF
WELDED MEMBER OR
JOINT
STRUCTURAL STEEL INSPECTION NOTES:
OBSERVE - OBSERVE THESE ITEMS ON A RANDOM BASIS
PERFORM - THESE INSPECTION SHALL BE PERFORMED FOR EACH WELDED CONNECTION, EACH BOLTED CONNECTION,
AND EACH ITEM, PRIOR TO ACCEPTANCE
1
No. Description Date
PERMIT SET 07.02.2015
1 PERMIT RESPONSE 08.04.2015
2 FND SET 09.22.2015
W1
2 6345
24'-4"8'-7 1/2"21'-3"20'-1"6"
A
B
C
K
L
M 3'-7 1/2"3'-3"30'-1 3/4"7'-4"6'-3 1/4"3
S3116"10'-8"SOG5A
SOG4A
132'-5"
132'-10"
5
S320
4
S320
6"
6"
9'-7"1'-0"
6"6'-6"
STEP T/WALL
STEP T/WALL
4
S310
STEP T/WALL
T/WALL= 136' - 6"
7
7
7
7
2
STEP T/WALL
7
7
T/WALL= 133' - 0"
T/WALL= 136' - 6"
3
T/WALL= 134' - 0"
STEP T/WALL
T/WALL= 133' - 6"
3
2
3
9
2
2
CONTR COORD W/
ELEV SUPPLIER
12
3" TO COL CL
3" TO COL CL
12
3
S311
T/FTG = 131'-6"
T/FTG = 129'-6"
STEP T/FTG
1
S311
S310
6 TYP AT WALL
CORNERS
8'-0"6"2 3/4"
7 1/4"
3
S311
SIM
T/WALL= 142' - 3 3/4"STEP T/WALLSTEP T/WALL8
S310
TYP
STEP T/FTG
7
S320
1 TYP
6
S320
3
S311
SIM
7
T/WALL= 142' - 3 3/4"
7
7
7
7
F4
129'-6"
F4
129'-6"
F4
131'-5"
F4
131'-6"
F2
131'-6"
10
F3
131'-6"
3'-0"
7
7
4'-0"1'-0"2'-0"SOG4A
132'-11"W1-B0W1-D9W1-B0W1-B0T/FTG = 129'-6"
TYP
T/FTG = 131'-6"
T/FTG = 129'-6"36'-9 1/8"W1-B6W1-B6
W1-B6
9 6"1'-0"1'-0"6"T/WALL= 138' - 9"1'-0"3
S311
SIM
1'-0"1'-0"1'-0"6"6"8"T/FTG = 129'-6"
3
S311
T/WALL= 138' - 5 1/2"
1
S311
T/FTG = 129'-6"
1'-0"
1'-0"7'-9 1/2"1'-0"
2 3/4"
3 1/4"
2'-2"1'-4"4'-2"
STEP T/WALL
T/WALL= 134' - 0"1'-0"T/WALL= 133' - 6"
BP1
BP1
BP1
BP1
BP1
BP1
BP2
BP1
BP1
BP2
BP2
11
3
S311
SIM
T/FTG = 131'-6"1'-0"CONC STEM WALL
PER 8/S310
1'-0"11CONC STEM WALL
PER 8/S310
3
F4
131'-6"
10
S310
T/FTG = 131'-6"
T/FTG = 131'-6"
F3
131'-6"
T/FTG = 131'-6"
8
S310
TYP
CONC STEM WALL
PER 8/S310
1'-0"1'-0"1'-0"1'-0"
7
S311
T/FTG = 131'-6"
3
BP2
BP2
W1-D9
BACKFILL FOUNDATION WALLS
TO MAX HEIGHT NOTED ON
PRIOR TO PLACING LEVEL 2
FRAMING AND FLOOR SHEATHING
3/S311
BACKFILL FOUNDATION WALLS
TO MAX HEIGHT NOTED ON
PRIOR TO PLACING LEVEL 2
FRAMING AND FLOOR SHEATHING
3/S311
S200
2LOWER
STAIR
LANDING
UP
7
1
1
1
1
1
5
S320 7'-4 1/2"8
S320
11
S311
SIMPSON CB66
HDG COLUMN
BASE
1
10
S310
SIM
9 9 BP1BP2
BP1
6'-2 3/4"W1-C6BP3
S500
12FOR BP
TYP
11
S311
TYP AT CONC
SITE WALLS
11
S311
1
T/FTG = 131'-6"
8
S311
3 1/4"
2 3/4"
10"
T/WALL = 141'-10"
T/WALL = 141'-10"
T/FTG = 129'-6"
STEP T/WALL
T/WALL = 141'-10"
1'-0"
6"
T/WALL = 140'-8"
STEP T/WALL
T/WALL= 136' - 6"
T/WALL= 135' - 9 1/2"
T/WALL= 135' - 9 1/2"
1
1
1'-6"1'-6"
T/WALL= 142' - 3 3/4"
T/WALL= 138' - 5 1/2"
9'-7"
STEP T/WALL STEP T/WALL
72 BP2
BP2
STEP T/WALL
4'-0"5'-2"4'-4"2'-9"T/FTG = 131'-6"
STEP T/WALL
T/WALL= 145' - 10"
T/WALL= 144' - 1"
T/WALL= 141' - 7 1/2"
1'-4"4'-6"6"12'-11"1'-8 1/2"4'-5"3'-0"T/WALL= 140' - 1"
T/WALL= 136' - 7"
T/WALL = VARIES
5
S310
T/FTG = 129'-6"4"8"8'-3"1'-4"T/FTG = 129'-6"
TYP
T/WALL= 136' - 3"7'-9 1/4"1'-4"7'-9"1'-0"T/WALL= 136' - 3"
T/WALL= 136' - 3"
T/FTG = 129'-6"
8
S320
T/FTG = 129'-6"
COORD W/ SPA
SUPPLIER
1
1
1
5
S320
STEP T/WALL
STEP T/WALL
STEP T/WALL
STEP T/WALL 14'-10"T/WALL= 138' - 9"
10'-5 3/4"
1
1
11
S311
T/WALL= 132' - 2"17'-7"T/WALL= 132' - 2"3'-3"1'-0 1/2"20'-3" CONTR COORD W/ GARAGE DOOR SUPPLIER4'-4 1/2"3'-1 1/2"T/WALL= 133' - 6"
T/WALL= 133' - 6"
6'-3"
1'-10 1/2"
STEP T/WALL
T/WALL= 131' - 9"
3'-9"
1'-4"3'-8"
MAX
VARIES
T/WALL= 133' - 0"
8
S320
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:44 PMS100
LEVEL 1 FLOOR PLAN
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
1/4" = 1'-0"
LEVEL 1
COLUMN SCHEDULE (SEE 6/S601)
MARK TYPE REMARKS
1 (2) 1 1/2x5 1/2 LSL
2 (3) 1 1/2x5 1/2 LSL
3 (4) 1 1/2x5 1/2 LSL
4 (3) 5 1/2 LVL
5 (4) 5 1/2 LVL
6 HSS3x3x1/4 SEE 12/S500 FOR BP
7 HSS4x4x1/4 SEE 12/S500 FOR BP
8 (5) 1 1/2x5 1/2 LSL
9 HSS5x5x1/4 SEE 12/S500 FOR BP
10 HSS9x5x1/4 SEE 12/S500 FOR BP
11 3 1/2x5 1/2 PSL
12 6x6 PRESERVATIVE TREATED
NORTH
FOUNDATION NOTES
1.SEE S0 SERIES SHEETS FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
2.SEE S3 SERIES SHEETS FOR TYPICAL CONCRETE DETAILS.
3.SEE S320 FOR TYPICAL SLAB-ON-GRADE DETAILS.
4.SEE ARCHITECTURAL DRAWINGS FOR VAPOR RETARDER LOCATIONS. CONTRACTOR SHALL INSTALL VAPOR RETARDER PER
RECOMMENDATIONS OF PCA AND ACI 302.1R-04.
5.SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SLAB SLOPES, DEPRESSIONS, FILL, PADS, AND CURBS NOT SHOWN
ON THE STRUCTURAL DRAWINGS.
6.SEE S310 FOR TYPICAL FOOTING AND FOUNDATION DETAILS.
7.SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS OF ALL WOOD BEARING AND PARTITION WALLS.
8.CONTRACTOR TO COORDINATE STONE LEDGE ELEVATIONS WITH ARCHITECTURAL AND LANDSCAPE GRADING DRAWINGS
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
2 6345
A
B
C
K
L
M
24'-4"8'-7 1/2"21'-3"20'-1"6"3'-7 1/2"3'-3"30'-1 3/4"7'-4"6'-3 1/4"3
S3116"10'-8"SOG5A
SOG4A
132'-5"
132'-10"
5
S320
4
S320
6"
6"
9'-7"1'-0"
6"6'-6"
STEP T/WALL
STEP T/WALL
4
S310
STEP T/WALL
T/WALL= 136' - 6"
7
7
7
7
2
STEP T/WALL
7
7
T/WALL= 133' - 0"
T/WALL= 136' - 6"
3
T/WALL= 134' - 0"
STEP T/WALL
T/WALL= 133' - 6"
3
2
3
9
2
2
CONTR COORD W/
ELEV SUPPLIER
12
3" TO COL CL
3" TO COL CL
12
3
S311
T/FTG = 131'-6"
T/FTG = 129'-6"
STEP T/FTG
1
S311
S310
6 TYP AT WALL
CORNERS
8'-0"6"2 3/4"
7 1/4"
3
S311
SIM
T/WALL= 142' - 3 3/4"STEP T/WALLSTEP T/WALL8
S310
TYP
STEP T/FTG
7
S320
1 TYP
6
S320
3
S311
SIM
7
T/WALL= 142' - 3 3/4"
7
7
7
7
F4
129'-6"
F4
129'-6"
F4
131'-5"
F4
131'-6"
F2
131'-6"
10
F3
131'-6"
3'-0"
7
7
4'-0"2'-0"SOG4A
132'-11"
T/FTG = 129'-6"
TYP
T/FTG = 131'-6"
T/FTG = 129'-6"
9 6"1'-0"1'-0"6"T/WALL= 138' - 9"1'-0"3
S311
SIM
1'-0"1'-0"1'-0"6"6"8"T/FTG = 129'-6"
3
S311
T/WALL= 138' - 5 1/2"
1
S311
T/FTG = 129'-6"
1'-0"
1'-0"7'-9 1/2"1'-0"
2 3/4"
3 1/4"
2'-2"
1'-4"
4'-2"
STEP T/WALL
T/WALL= 134' - 0"1'-0"T/WALL= 133' - 6"
BP1
BP1
BP1
BP1
BP1
BP1
BP2
BP1
BP1
BP2
BP2
11
3
S311
SIM
T/FTG = 131'-6"1'-0"CONC STEM WALL
PER 8/S310
1'-0"11CONC STEM WALL
PER 8/S310
3
F4
131'-6"
10
S310
T/FTG = 131'-6"
T/FTG = 131'-6"
F3
131'-6"
T/FTG = 131'-6"
8
S310
TYP
CONC STEM WALL
PER 8/S310
1'-0"1'-0"1'-0"1'-0"
7
S311
T/FTG = 131'-6"
3
BP2
BP2
UP
7
5
S320
8
S320
8
S320
11
S311
SIMPSON CB66
HDG COLUMN
BASE
10
S310
SIM
9 9 BP1BP2
BP1 BP3
S500
12FOR BP
TYP
11
S311
TYP AT CONC
SITE WALLS
11
S311
T/FTG = 131'-6"
8
S311
3 1/4"
2 3/4"
10"
T/WALL = 141'-10"
T/WALL = 141'-10"
T/FTG = 129'-6"
STEP T/WALL
T/WALL = 141'-10"
4"
6"
2"
4"
7'-1 1/2"
1'-0"
6"
T/WALL = 140'-8"
STEP T/WALL
T/WALL= 136' - 6"
T/WALL= 135' - 9 1/2"
T/WALL= 135' - 9 1/2"
1'-6"1'-6"
T/WALL= 142' - 3 3/4"
T/WALL= 138' - 5 1/2"
9'-7"
STEP T/WALL STEP T/WALL
72 BP2
BP2
STEP T/WALL
4'-0"5'-2"4'-4"2'-9"T/FTG = 131'-6"
STEP T/WALL
T/WALL= 145' - 10"
T/WALL= 144' - 1"
T/WALL= 141' - 7 1/2"
1'-4"4'-6"6"12'-11"1'-8 1/2"4'-5"3'-0"T/WALL= 140' - 1"
T/WALL= 136' - 7"
T/WALL = VARIES
5
S310
T/FTG = 129'-6"4"8"8'-3"1'-4"4'-4"T/FTG = 129'-6"
TYP
T/WALL= 136' - 3"7'-9 1/4"1'-4"7'-9"1'-0"T/WALL= 136' - 3"
T/WALL= 136' - 3"
T/FTG = 129'-6"
8
S320
T/FTG = 129'-6"
COORD W/ SPA
SUPPLIER
5
S320
STEP T/WALL
STEP T/WALL
STEP T/WALL
STEP T/WALL 14'-10"T/WALL= 138' - 9"
11
S311
T/WALL= 132' - 2"
T/WALL= 132' - 2"20'-3" CONTR COORD W/ GARAGE DOOR SUPPLIER4'-4 1/2"3'-1 1/2"T/WALL= 133' - 6"
T/WALL= 133' - 6"
6'-3"
1'-10 1/2"
STEP T/WALL
T/WALL= 131' - 9"
3'-9"
1'-4"3'-8"
MAX
VARIES
11'-3"8"3'-8"1'-0"5'-4"T/WALL= 141' - 8 3/4"
T/WALL= 140' - 9"
TOC= 140'-9"2'-2"8"3'-6"10"4'-0"8
S311
9
S311
12
S311
T/WALL = 142'-3"
8
S311
T/WALL= 133' - 0"
6
S311 SIM
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:45 PMS100a
LEVEL 1 FND DIMENSIONS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
No. Description Date
1 FND SET 09.22.2015
NORTH
FOUNDATION NOTES
1.SEE S0 SERIES SHEETS FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
2.SEE S3 SERIES SHEETS FOR TYPICAL CONCRETE DETAILS.
3.SEE S320 FOR TYPICAL SLAB-ON-GRADE DETAILS.
4.SEE ARCHITECTURAL DRAWINGS FOR VAPOR RETARDER LOCATIONS. CONTRACTOR SHALL INSTALL VAPOR RETARDER PER
RECOMMENDATIONS OF PCA AND ACI 302.1R-04.
5.SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SLAB SLOPES, DEPRESSIONS, FILL, PADS, AND CURBS NOT SHOWN
ON THE STRUCTURAL DRAWINGS.
6.SEE S310 FOR TYPICAL FOOTING AND FOUNDATION DETAILS.
7.SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS OF ALL WOOD BEARING AND PARTITION WALLS.
8.CONTRACTOR TO COORDINATE STONE LEDGE ELEVATIONS WITH ARCHITECTURAL AND LANDSCAPE GRADING DRAWINGS
1/4" = 1'-0"
LEVEL 1 FND DIMENSIONS
1
W D
2 6345
A
B
C
K
L
M
24'-4"8'-7 1/2"21'-3"20'-1"3'-7 1/2"3'-3"30'-1 3/4"7'-4"6'-3 1/4"7
7
7
FH3 - 33H8 - 2211 7/8" TJI210 @ 16" O.C.9 1/2" LVL @ 16" O.C.11 7/8" TJI210 @ 16" O.C.9 1/2" LVL @ 16" O.C.11 7/8" TJI210 @ 16" O.C.11 7/8" TJI210 @ 16" O.C.H1 - 11H8 - 33W10x1911 7/8" TJI560 @ 16" O.C.11 7/8" LVL @ 16" O.C.(2) 11 7/8 LVL
(2) 11 7/8 LVL
1@ 16" O.C.11 7/8" TJI560@ 16" O.C.11 7/8" LVL11 7/8" TJI210 @ 16" O.C.3
7
97 9
7 11 7/8" TJI-360 @ 16" OC2
7W10x68W10x12W10x19W18x40 @ 16" O.C.11 7/8" TJI56010
S500
W10x193
S500
TYP
5
S610
TYP
1
S610
TYP W18x404
S610
3
S610
6
S500
4
S500
1'-0"SIM
( 142' - 4 1/2" )
7
S500
SIM9
S610
WS3142'-6"10
S610
2
2
2
S610
TYP AT
CANTILEVER
4
S311
5
S311
6
S311WS3142'-0 1/4"WS3142'-6"WS3142'-6"WS3142'-0 1/4"12
S610
2FH1 - 1FH1 - 1
(4) 11 7/8 LVL
W10x22
@ 16" OC11 7/8" LVL@ 16" OC11 7/8" TJI-210W10x12W10x2211 7/8" TJI-560 @ 16" OC(3) 11 7/8 LVL11 7/8" TJI-560 @ 16" OC(3) 11 7/8 LVLW1-B0W1-C1W1-B1W1-B6W1-B0W1-C1W1-B1W1-B1W1-C2W1-C2W1-B0W1-B0SIMPSON STRONG WALL SSW18x10
HD 6 AT 1ST FLOORW1-C9
W1-C4
FH2 - 2
7 7
H2 - 22 H2 - 22
SEE ARCH, 2'-6" MAX
3
(3) 11 7/8 LVL2
1/S500(2) 11 7/8 LVL (2) 11 7/8 LVL
( 141'-10" )( 141'-10" )SIMPSON STRONG WALL SSW18x10
2 1/2"
2 1/2"6
S311
8
S610
1
S501
2
S602
2
S602
2
2
9 10
HSS10x5x3/8
6
S501
EE FOR HSS BM
TO COL CON
3
3 (2) 11 7/8 LVL(2) 11 7/8 LVL
(2) 11 7/8 LVL1/S500EE3
4
S501
7
7
9
9
4
S500 EE(2) 11 7/8 LVL9
7
(2) 11 7/8 LVLW10x19
W10x19
3
S501
1/S500
(142'- 4 1/2")11 7/8" TJI210 @ 16" O.C.1/S5008'-6"
10'-11 1/2"HSS6x4x5/16HSS6x4x5/16S200
3
UP
DOWNHSS6x4x5/16HSS6x4x5/164
S611 SIM
S200
2
(2) 11 7/8 LVL
SEE
MARK 2
3/S602
SEE MARK 43/S602
8
S311
SIMPSON STRONG
WALL SSW18x10
BELOW
ABOVE
(2) 11 7/8 LVLH6 - 216'-2 3/4"W1-C1H6 - 128
S311
SIMSOG6ASEE ARCHSOG6A
VARIES
SEE ARCH
8
S320
STEP T/WALLSTEP T/WALL
1
11
S310
11'-3"8"3'-8"1'-0"5'-4"1'-0"8'-1 1/2"8"2 3/4"TOC= 140'-9"
T/WALL= 141' - 8 3/4"
9
S3113'-6"1'-0"8'-3"1'-4"4'-4"137'-6 1/2"
SOG6A
COORD W/ SPA SUPPLIER
T/WALL= 140' - 9"
12
S311
TOC= 140'-9"TOC= 140'-9"
11
S310
COORD W/ SPA
SUPPLIER
ARCH EXPOSED BOARD
FORMED CONCRETE WALLS.
SEE ARCH FOR FINISH
REQUIREMENTS4'-0"5'-2"4'-4"7
2
SIM
5
S311
STEP T/WALL
T/WALL= 145' - 10"
T/WALL= 144' - 1"
STEP T/WALL
11
S310
8
S311
SIM
T/FTG = 138'-0"
12
S310
DRAIN. SEE CIVIL
5
S310
8
S311
4"
6"
2"
4"
8
S610
FLOOR FRAMING PLAN NOTES
1.SEE S0 SERIES SHEETS FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
2.SEE S5 SERIES SHEETS FOR TYPICAL STEEL DETAILS.
3.SEE S6 SERIES SHEETS FOR TYPICAL WOOD DETAILS.
4.TOP OF STRUCTURAL STEEL ELEVATION SHALL BE 142’-3 3/4" UNLESS NOTED OTHERWISE ON PLAN.
5.WOOD SHEAR WALLS ABOVE THE FLOOR NOTED THUS:
SEE
6.ALL WALLS SHALL BE W1-A, UNLESS NOTED OTHERWISE.
7.WOOD HEADERS NOTED THUS:
SEE
8.COLUMNS AND POSTS NOTED THUS:
SEE SCHEDULE AND
9.FOR WOOD HANGER SCHEDULE, SEE: UNO
10.FOR WOOD FLOOR SCHEDULE, SEE:
11.FOR VENEER LOOSE LINTEL, SEE:
5/S601 W1-A
H6-22
12/S600
5 BP-1
6/S601
9/S601
8/S601
12/S601
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:47 PMS101
LEVEL 2 FLOOR PLAN
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
1/4" = 1'-0"
LEVEL 2
NORTH
COLUMN SCHEDULE (SEE 6/S601)
MARK TYPE REMARKS
1 (2) 1 1/2x5 1/2 LSL
2 (3) 1 1/2x5 1/2 LSL
3 (4) 1 1/2x5 1/2 LSL
4 (3) 5 1/2 LVL
5 (4) 5 1/2 LVL
6 HSS3x3x1/4 SEE 12/S500 FOR BP
7 HSS4x4x1/4 SEE 12/S500 FOR BP
8 (5) 1 1/2x5 1/2 LSL
9 HSS5x5x1/4 SEE 12/S500 FOR BP
10 HSS9x5x1/4 SEE 12/S500 FOR BP
11 3 1/2x5 1/2 PSL
12 6x6 PRESERVATIVE TREATED
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
21
28
36
43
62
71
80
90
100
LAP SPLICE AND DEVELOPMENT LENGTH SCHEDULE (INCHES)
#3
#4
#5
#6
#7
#8
#9
#10
#11
9
11
14
17
19
22
25
28
31
12
15
19
23
27
30
34
38
43
6
8
10
12
13
15
18
20
22
22
29
36
43
63
72
81
91
101
GENERAL NOTES:
1. 'LCE' = COMPRESSION EMBEDMENT LENGTH, 'LCS' = COMPRESSION LAP SPLICE LENGTH, 'LTE' = TENSION EMBEDMENT LENGTH,
'LTS' = TENSION LAP SPLICE LENGTH, 'LDH' = HOOK DEVELOPMENT LENGTH
2. 'TOP' BARS ARE HORIZONTAL BARS PLACED SUCH THAT MORE THAN 12 IN. OF FRESH CONCRETE IS CAST BELOW THE BAR
3. ALL BARS THAT ARE NOT 'TOP' BARS ARE 'OTHER' BARS
4. UNLESS NOTED OTHERWISE, ALL HOOK BARS SHALL EXTEND TO THE FAR FACE (LESS 2" COVER)
LAP SPLICE NOTES:
1. ALL SPLICES SHALL BE WIRED IN CONTACT. TOP AND BOTTOM BEAM SPLICES SHALL BE STACKED VERTICALLY
2. ALL SPLICES ARE 'LTS' UNLESS NOTED OTHERWISE
3. SMALLER BAR LAP LENGTH SHALL BE USED WHEN SPLICING DIFFERENT SIZED BARS
A. COMPRESSION LAP LENGTH SHALL NOT BE LESS THAN 'LCE' OF THE LARGER BAR
B. TENSION LAP LENGTH SHALL NOT BE LESS THAN 'LTE' OF THE LARGER BAR
4. LAP LENGTHS SPECIFICALLY DETAILED ON DRAWINGS SHALL GOVERN IN LIEU OF LAP LENGTHS SCHEDULED
5. BUNDLED BAR SPLICES:
A. INDIVIDUAL BAR SPLICES WITHIN THE BUNDLE SHALL BE STAGGERED
B. INCREASE LAP LENGTH 20% FOR A 3 BAR BUNDLE
C. INCREASE LAP LENGTH 33% FOR A 4 BAR BUNDLE
6. IF A NOTE OR DETAIL CALLS FOR A BAR TO BE EMBEDDED Ld (DEVELOPMENT LENGTH) INTO CONCRETE, THIS LENGTH SHALL CORRESPOND TO A 'LTE' LAP
ADJUSTMENTS TO GIVEN LENGTHS:
1. IF REINFORCING IS SPECIFIED AS EPOXY COATED, INCREASE SCHEDULED LENGTHS BY 50%
2. IF LIGHTWEIGHT AGGREGATE IS SPECIFIED, INCREASE SCHEDULED LAP BY 30%
3. SCHEDULED LENGTHS ASSUME:
A. CLEAR COVER IS GREATER THAN BAR DIAMETER, BUT NOT LESS THAN 3/4"
B. CLEAR SPACING BETWEEN BARS IS GREATER THAN 2 BAR DIAMETERS
C. IF EITHER CONDITION A OR B IS NOT MET FOR A GIVEN BAR, INCREASE LENGTHS BY 50%
4. LENGTHS NOTED BASED ON Fy = 60,000 PSI. FOR OTHER YIELD STRENGTHS, MULTIPLY LENGTHS NOTED BY Fy/60,000
HOOK EMBEDMENT NOTES:
1. SCHEDULED HOOK EMBEDMENT LENGTHS ASSUME:
A. SIDE COVER IS 2 1/2 INCHES OR GREATER
B. COVER BEYOND IS 2 INCHES OR GREATER
2. IF REINFORCING IS SPECIFIED AS EPOXY COATED, INCREASE SCHEDULED LENGTHS BY 20%
3. IF LIGHTWEIGHT AGGREGATE IS SPECIFIED, INCREASE SCHEDULED LENGTHS BY 30%
4. IF SIDE COVER IS LESS THAN 2 1/2 INCHES, INCREASE LENGTHS BY 40%
77
70
62
55
48
131
118
105
93
81
22
33
27
16
37
56
46
28
COMP TENSION
78
87
8
10
12
15
17
19
22
24
27
12
15
19
23
27
30
34
38
43
6
7
8
11
12
13
15
17
19
19
25
31
37
54
62
70
79
87 67
60
54
47
42
113
102
91
80
70
19
28
24
14
32
48
40
24
COMP
17
22
28
33
48
55
62
70
78
6
6
8
9
11
12
13
15
17
17
22
28
33
49
55
63
70
78 60
54
48
42
37
101
91
81
72
63
17
25
21
13
29
43
36
2218
25
31
37
54
62
70
8
9
12
14
16
18
21
23
26
12
15
19
23
27
30
34
38
43
LCE LCS LDH
LTE
TOP
LTE
OTHER
LTS
TOP
LTS
OTHER LCE LCS
F'c = 3,000 PSI THRU 3,500 PSI
BAR SIZE
(IN-LB)
F'c = 4,000 PSI F'c = 5,000 PSI
COMP TENSIONTENSION
LCE LCS LDH
LTE
TOP
LTE
OTHER
LTS
TOP
LTS
OTHER LDH LTE
TOP
LTE
OTHER
LTS
TOP
LTS
OTHER
#10
#13
#16
#19
#22
#25
#29
#32
#36
BAR SIZE
(METRIC)
CONCRETE COVER
CASE COVER (IN)
CONCRETE PLACED AGAINST EARTH 3
CONCRETE PLACED IN FORMS, EXPOSED TO WEATHER OR EARTH 2
SLABS OR WALLS NOT EXPOSED TO EARTH OR WEATHER 1
NOTES:
1. ALL BENDS SHALL BE MADE COLD
2. #14 & #18 BARS SHALL BE BEND TESTED
& LAB APPROVED PRIOR TO BENDING
STANDARD BENDS
90° HOOK
#3-#5
d
3" MIN
6d
TYPICAL REINFORCING BENDS
STIRRUP/TIE BENDS
180° HOOK
D 21
6
MAX OFFSET BEND
D1
#3 - #8 6d
#9 - #11 8d
90° HOOK
#6-#8
d
12d
D 2135° HOOK
d6d3" MIND290° HOOKd 12dD 1
180° HOOKd 4d
2 1/2" MIN
D1
#3 - #5 4d
#6 - #8 6d
D2
d4d
2 1/2" MIN
D2
ADD 1/2 NUMBER OF BARS
INTERRUPTED BY OPNG
PLUS 1, SPACE AT 3" OC
DETAIL SIMILAR
FOR CIRCULAR
OPENINGS
NOTES:
1. DETAIL APPLIES UNLESS REINF IS SPECIFICALLY DETAILED ON THE DRAWINGS
2. HOOK BARS WITH STANDARD HOOK WHERE LTS CANNOT BE ACHIEVED
3'-0" MAX
W
H, 3'-0" MAXTYPLTSTYPICAL OPENINGTMAX D=0.3T OR 2"WHICHEVER IS SMALLERD = OUTSIDE DIAMETER
3D (12" MIN)
CLEAR
NOTE: WHERE CLEAR DISTANCE BETWEEN SLEEVES CAN NOT BE
ACHIEVED AS SHOWN, STRUCTURAL ENGINEER OF RECORD SHALL BE
NOTIFIED.
SCHEDULE 40 SLEEVES SHALL BE USED IN CRITICAL AREAS OF THE
WALL AND SLABS AS DETERMINED BY STRUCTURAL ENGINEER OF
RECORD.
IN WALL OR SLAB CONDUITS GREATER THAN [0.2T] SHALL BE SUBMITTED
FOR REVIEW
AT PIPING OR CONDUIT
NOTE 1
D 12" MAX
NOTE 1ALIGN PEN'S
VERTICALLY
B/WALL
NOTES:
1. GREATER OF 2xD AND 12", WHERE CLEAR DISTANCE IS NOT ACHIEVABLE, TREAT AREA
AS SINGLE OPENING REINFORCED PER "TYPICAL OPENING" DETAIL
2. DO NOT CUT REBAR AT PENETRATIONS LOCS. REBAR MAY BE MOVED 8" MAX TO
ACCOMMODATE PENETRATIONS EDGES, TYP12" FROM ALLTYP EW
2" CLR TO REINF,
NOTE 2
AT OPENINGS 12" OR LESS
6'-6" MAX 1'-0" MIN
(2) #4@3" OC ES OF OPENING. FULL HEIGHT
(3) #4@3" OC T&B. CONTINUE FULL WIDTH OF WALL
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:48 PMS300
TYP CONCRETE DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
NO SCALE8 REINFORCING DEVELOPMENT, PLACEMENT, AND BEND INFO
NO SCALE9 TYP CONC WALL PENETRATIONS
3/4" = 1'-0"10 FIREPLACE OPENING
NOT USED
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
1
1
WALL
DWLS
LTS
T/FTG
SEE PLAN
MATCH SIZE AND NUMBER
OF FTG LONG BARS 2'-0" MAXT(1'-0" MIN)
T
BOT REINF
PER SCHED
TOP REINF IF
NOTED IN
SCHED
PLAN WL
L BARS
W BARS
APPROVED BRG
MATL PER
GEOTECH (L x W)
PLAN DIMENSIONS TT/FTG, SEE PLAN
L BARS
W BARS 2" CLR3" CLRMARK FOOTING SIZE
L x W x T
REINFORCING SERVICE
CAPACITY
(KIPS)
REMARKS
F2 2'-0"x2'-0"x1'-0" (3) #4 EW BOT
40
F3 3'-0"x3'-0"x1'-0" (4) #4 EW BOT
62
F4 4'-0"x4'-0"x1'-0" (4) #5 EW BOT
90
F5 5'-0"x5'-0"x1'-0" (5) #5 EW BOT
122
F6 6'-0"x6'-0"x1'-2" (7) #5 EW BOT
160
F7 7'-0"x7'-0"x1'-6" (7) #6 EW BOT
F8 8'-0"x8'-0"x1'-10" (9) #6 EW BOT
22
10
SPREAD FOOTING SCHEDULE
SOIL ALLOWABLE PRESSURE = 2500 PSF
-
-
-
-
-
-
-
INSIDE FACESINSIDE FACES
INSIDE FACES
CROSS WALL
BAR SIZE & SPACING
TO MATCH HORIZ
REINF
OUTSIDE FACE (SOIL
SIDE)
OUTSIDE FACE
(SOIL SIDE)
HORIZ REINF
SOLID CIRCLE INDICATES ADDITIONAL
VERTICAL BARS, SIZE TO MATCH
WALL VERT REINF
OPEN CIRCLE INDICATES
VERTICAL REINF
LTS OR CONT, TYP
VERT WALL
REINF
HORIZ WALL
REINF
INTERMITTENT 1'-0"
LONG KEYS @ 2'-0" OC.
EDGES MAY BE ANGLED
AT CONTR'S OPTION
LTS
1ST POUR 2ND POUR
1 1/2"EQEQEQ1'-0"1'-0"1'-6"
S320
36"
(2) #4xCONT
(2) #4@12" OC (2 MIN)
#4@18" OC
ALT HOOK DIR VARIES. SEE PLANS320
3
T/FTG = SEE PLAN
#4@12" OC EW
3" CLRSTD HOOK
SEE PLAN
#4@12" OC, EW LTS MINCOORDINATE HORIZ CONST JT LOCS
WITH ARCH. LIMIT POUR HEIGHT AS
REQD TO ACHIEVE CONSOLIDATION
AND SPECIFIED FINISH
ARCHITECTURALLY
EXPOSED CONCRETE
FINISH. SEE ARCH FOR
FINISH, COLOR AND MOCK
UP REQUIREMENTS
6
S310
FOR "OUTSIDE
FACE"
CORNER
REINF1'-0"1'-0"4'-0"
S320
3
6"
(5) #4xCONT
(2) #4@12" OC (2 MIN)
#4@18" OC
ALT HOOK DIR
#4@12" OC
TRANSVERSE
FND WALL
FTG
STEM WALL
DOWELS TO
MATCH STEM
WALL HORIZONAL
REINF
4"
3 BARS MIN, TO
MATCH FTG
LONGITUDINAL
REINF
MIN, TYP
LTS
T/WALL = SEE PLAN
CONTR OPTION JOINT
ELEV = 138'-0"
#4@10" OC EACH FACE
#4@16" OC EACH FACE
ARCH EXPOSED BOARD
FORMED CONCRETE FINISH
ABOVE GRADE. SEE ARCH
FOR REQTS
LTS OR CONT3 1/2"x 1'-0" KEY AT EACH STEP
1 1/2"
#4@12" OC HORIZ
#4@16" OC VERT
(3) #4xCONT
#4@16" OC
2'-0"1'-0"3" CLR4"8"
T/LEDGE = CONTR COORD
T/WALL = SEE PLAN
T/FTG = SEE PLAN
1 1/2" x FULL DEPTH
KEY AT SPA SLAB
SPA SLAB. SEE PLAN COORD
ELEV W/ SPA SUPPLIER
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:49 PMS310
TYP FOUNDATION DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
NO SCALE4 TYP SINGLE STEP AT WALL FOOTING
NO SCALE2 TYP SPREAD FOOTING
NO SCALE6 TYP FND WALL W/TWO LAYERS REINF
NO SCALE7 TYP WALL VERTICAL CONST JOINT
1" = 1'-0"8 INT WALL FOOTING
NO SCALE9 CHIMNEY FOUNDATION SECTION
1" = 1'-0"10 INT WALL FOOTING - 2
NOT USED
NO SCALE11 TYP STEM WALL ON STRIP FTG AT
FND WALL
1
1" = 1'-0"12 BOARD FORMED ENTRY STAIR WALL
1
1" = 1'-0"5 SPA WALL
1
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
6" MIN7'-0" MAX AT SIM BEFORE LEVEL 2 FLOOR INSTALLED2'-6" MAX AT TYP4'-6" AT SIM
3'-0" AT TYP 6"6"1'-6"
T/WALL = SEE PLAN
1'-0"#4@16" OC HORIZ
#4@16" OC VERT AT TYP
#6@16" OC VERT AT SIM
2" CLR 1" CLR
3" CLR2" CLR
T/FTG = SEE PLAN
#4xCONT @16" OC
#4@16" OC
PERIMETER DRAIN. SEE CIVIL
#4@16" OC VERT
#4@16" OC AT TYP
#6@16" OC AT SIM
--
T/LEDGE = CONTR COORD
T/WALL = SEE PLAN
#4@16" OC HORIZ
#4@16" OC VERT
(3) #4xCONT
#4@16" OC
2'-0"1'-0"3" CLRS320
3
--
6"6"
T/LEDGE = CONTR COORD
TREATED 2x NAILER
T/WALL = SEE PLAN
WEB STIFFENER EA
FACE, TYP
TOP FLANGE HANGER
PER HANGER SCHED, TYP
TREATED 2x NAILER
T/WALL = SEE PLAN
TREATED 2x LEDGER
5/8"Ø ADHESIVE ANCHOR W/
4" EMBED AT 12" OC.
THREADED ROD SHALL BE
HDG OR MECHANICALLY
GALVANIZED (CLASS 55)4"FULL DEPTH BLOCKING
FOR (2) BAYS
FOR ADDNL INFO, SEE 5/S311
1
1 8"1
1 8"--
AT SIM
AT TYP
1
S320
3
6" STEM PER
8/S310
#5@12"OC EW BOT
1'-0"#4@12" OC HORIZ
#4@16" OC VERT
(3) #4xCONT
#4@16" OC
2'-0"1'-0"3" CLR4"8"4'-0" MIN6"2" ± 2"T/LEDGE = CONTR COORD
#4@12" OC EW
#4x AT 12" OC. CONTR OPTION
ASTM A706 AND FIELD BEND DOWN2'-6"2'-6"
T/WALL = SEE PLAN
ARCH EXPOSED BOARD FORMED
CONCRETE WALL AT SIM. NO
STONE LEDGE
APPROVED BRG
MATL PER
GEOTECH
3'-0"1'-4"1'-6"4'-0" MIN6'-0" MAX4"8"4"
SEE LANDSCAPE
SEE LANDSCAPE
1'-0"#6@16" OC
#4@16" OC
#4@12" OC HORIZ
#6@16" OC
#4@12" OC
1 1/2" KEY
2" CLR
2" CLR
3" CLRS311
8
SITE PAVING.
SEE CIVIL
T/WALL = SEE PLAN8"±2"S320
8
#4@8" OC HORIZ
EA FACE
#4@8" OC VERT,
EACH FACE
#4@ 9" OC EW
1'-0"3" CLR4'-0" MIN6"2" ± 2"TOC = SEE PLAN
BOULDER. SEE LANDSCAPE
T/WALL = SEE PLAN
#4x 2'-6"@ 8" OC EW
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:51 PMS311
TYP FOUNDATION DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
1" = 1'-0"3 TYP GRADE BEAM - 1
1" = 1'-0"1 TYP GRADE BEAM - 2 1" = 1'-0"4 WOOD JOIST PERP TO CONC WALL
1" = 1'-0"5 WOOD JOIST PARALLEL TO CONC WALL
1" = 1'-0"6 WOOD JOIST PARALLEL TO CONC
WALL AT PATIO
1 1/2" = 1'-0"7 ELEVATOR PIT SECTION
1" = 1'-0"8 BAR PATIO WALL
1
3/4" = 1'-0"11 SITE RETAINING WALL
1
1" = 1'-0"9 BAR PATIO STEPS
1
1" = 1'-0"12 BAR PATIO STONE SUPPORT
1
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
A
A
1/4" PREFORMED JT
FILLER OVER FULL SLAB
DEPTH, FILLER SHALL
NOT PROTRUDE ABOVE
SLAB
ELASTOMERIC JT
SEALANT WHERE
REQD (SEE ARCH)P CLRCONT VAPOR
RETARDER, SEE ARCH
BAR SUPPORTS
NOTES:
1. GRANULAR COURSE: 4" MIN COMPACTED GRANULAR FILL
2. PREPARED/COMPACTED SUBGRADE
SLAB REINF
NOTE 2NOTE 1TTYPICAL SLAB-ON-GRADE SECTION
CONT VAPOR
RETARDER,
SEE ARCH
2ND POUR1ST POUR
EXTEND REINF
THRU JT
1/8" .
NOTES:
1. PROVIDE TOOLED JT OR SAW CUT AS SOON AS THE CONC HAS HARDENED
SUFFICIENTLY TO PERMIT CUTTING WITHOUT CHIPPING, SPALLING, OR TEARING (BUT NOT
MORE THAN 12 HOURS AFTER CASTING)
2. SPACE JOINTS AT 10'-0" MAX EACH WAY WITH MAX ASPECT RATIO OF 1:1.5. PROVIDE
JOINT EW AT ALL RE-ENTRANT CORNERS.
LAP (2) MESH
PANELS OR LTS
1"NOTE 1
SLAB REINF
T2" MIN#4 ES CONT
2
1
CONSTRUCTION JOINT
CONTROL JOINT
6"
1
1
2
1
#4@12" (2 MIN)#4x
2'-0"
#4xCONT2'-6" MAX8" MAXMIN
8"
@12"
2'-0"2" CLR1 1/2" CLR
1 1/2" CLRCONST JT
L4x4x1/4x0'-6" w/(2) 1/2"Ø
BOLTS TO STRINGER &
(2) 5/8"Ø SIMPSON TITEN
HD w/4" EMBED TO SLAB
(3) #4xCONT
BEYOND STRINGERS
1'-0" (MIN), EXTEND
THICKENED ZONE 1'-0"8" MINTYP3" CLRCJ NOT PERMITTED
IN THIS ZONE
1 1/2"3"1 1/2"
2'-6"
TOP REINFORCING
MATCH TOP REINF
2'-0" HOOK
#4x
#4x4'-0@12", EC,
CTR
(1) #4xCONT
TYPICAL 2'-6"@12" TOP2"1 1/2" CLREQ EQ 8" MAX8"LTS + H
8"NOTES:
1. DETAIL APPLIES FOR ALL OPNGS IN SOG'S AND TOPPING SLABS
2. REINF NOT REQUIRED AT OPNGS SMALLER THAN 10"x10"
3. SEE OTHER DTLS FOR REINF AT OPNGS IN CONC WALLS, CONC STR SLABS, AND METAL
DECK SLABS
OPENING
RE-ENTRANT CORNER:DIAG BARS
2'-0" TYPTYP
1 1/2"3" TYP
(2) BARS EACH SIDE CENTERED
IN SLAB. MATCH SLAB REINF
SIZE (#4 MIN)
NOTES:
1. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION
2. REBAR IN STAIRS EXPOSED TO WEATHER SHALL BE EPOXY COATED
3. SPLICE #4 BARS 2'-4" AS NEEDED 1'-0"1'-0"
6
" MI
N1'-6"
1'-6"
#4@12"
#4@12"
(2) #4 BOT
6" MIN(2) #4 BOT 6" MINTYP3" CLRProject number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:52 PMS320
SOG DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
NO SCALE3 TYP SOG ISOLATION JOINT
NO SCALE1 TYP SOG SCHEDULE
NO SCALE2 TYP SOG JOINTS
NO SCALE4 TYP SOG STEP
NO SCALE6 TYP SOG BELOW METAL STAIR
NO SCALE5 TYP SOG EXT THRESHOLD
SLAB-ON-GRADE SCHEDULE
TYPE THICKNESS T REINFORCING BAR POSITION P REMARKS
SOG4A 4" WWR 6x6-W2.9xW2.9 1 1/2"
SOG5A 5" #4@18" OC 2"
SOG6A 6" #4@12" OC 2"
NO SCALE7 TYP TRIM REINF
NO SCALE8 TYP SOG STAIR
1
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
A
A
A
A
A
A
2
PL3/8 ES
5/16
5/16
k1/2"
1 1/2"
1 1/2"
1/2"1 1/2"3"3"3"(4) BOLTS IN STD HOLES
3
S500
STIFFENER
PL 3/8 ES
3"
5/16
AT HSS COL OR WF COL-WEB PERP TO BMk5/8"Ø ANCHOR RODS,
UNO
DOUBLE NUT OR
HEADED ANCHOR ROD
NOTES:
1. SEE COLUMN SCHEDULE OR PLAN FOR BASE PLATE MARK
2. PLATE SIZE MAY BE INCREASED AT HSS COL TO PROVIDE BOLT CLEARANCE
3. 24xANCHOR RODØ DECREASE AS REQUIRED TO PROVIDE 3" CLEAR COVER AT
FOOTING AND INTERIOR WALL LOCATIONS
PL WASHER 1/4x2x2
W/ STD HOLE
OPTIONAL LEVELING
NUTS
1"Ø HOLES MAX IN
BASE PLATE, UNO NHSS COLUMN
AT HSS OR PIPE COL
1/4
TTYP BASE PLATE SCHEDULE
BASE
PLATE
MARK
BP1
BP2
PLATE
THICKNESS
T (IN)
PLATE
WIDTH
B (IN)
PLATE
LENGTH
N (IN)1 1/2" NS GROUTABOVE NUT2" MINPROJECTIONB
3/4 5 16
2 1/2"3/4 5 11 1/2
3"4 1/2"2 1/2"1 1/2"BP2 LAYOUT 1 1/2"EQEQ
PJP 1/2 WALL
THICKNESS ES
AT 5" HSS
BP3 3/4 5 20
1
1/2"
1 1/2"
1 1/2"1 1/2"3" TYP1 1/2"5/16
5/16
PL3/8 W/ HORIZ SHORT
SLOTTED HOLES IN PL AND
STD HOLES IN BM WEB
3/4"Ø BOLTS
SEE SCHEDULE
CONNECTION SCHEDULE
BEAM SIZE # OF BOLTS
W10 2
W12 & W14 3
W16 & W18 4
W10x19 3
1/2"
1 1/2"1 1/2"1 1/2"3" TYP1 1/2"5/16
5/16
PL3/8 W/ HORIZ SHORT
SLOTTED HOLES IN PL AND
STD HOLES IN BM WEB
3/4"Ø BOLTS
SEE SCHEDULE
CONNECTION SCHEDULE
BEAM SIZE # OF BOLTS
W10 2
W12 3
1/2"1/2"1/2" RADIUS
STIFF PL 3/8 ES
CAP PL 3/4
W/ (4) BOLTS
1 1/2"1 1/2"
TYPICAL
1/4
1/4TYP k(2) BOLTS
1/2"
1 1/2"
1 1/2"
AT BEAM END
5/16 TYP
S500
3FOR COL
ABOVE AT
SIM
THAN T OF SHALLOWER BEAMT/2 MIN, BASED ON T OFDEEPER BEAM, BUT NOT GREATERFOR ANGLE/END
PLATE SIZE &
DETAIL
1" MAX
SEE SCHEDULE
FOR CAPACITY
AND WELDING
S500
5
DOUBLE ANGLE END PLATE
Z5.00B
20
1/2"1 1/2" MIN
(2) BOLT DOUBLE
ANGLE CONN
STD HOLES IN BM WEB
S500
5
S610
5
WF STEEL BEAM
EACH SIDE AT SIM
MIN1 1/4"MIN1 1/4"3" MIN, TYP,MAX
3"1 1/4" MIN
AT DBL ANGLES
STANDARD OR HORIZ
SHORT SLOTTED
HOLES MAY BE
USED, TYP
3/8" ANGLE
THICKNESS
BOLTS MAY BESTAGGEREDOR ALIGNEDMIN1 1/4"AT DOUBLE ANGLE3" MAX AT SINGLEANGLE, NO LIMITT/PL = T/BM, TYP
PL 3/4
(4) 3/4"Øx5" HAS,
AT 8" GAGE, TYP
13/16"x2 3/4" SLOTTED HOLE
IN L, STD HOLE IN BM
L6x3 1/2x3/8, (2) PT
BOLTS, CENTER
VERTICALLY ON BM
NOTES:
1. COMPLETE ALL WELDS PRIOR TO INSTALLING DECK OR USING BEAM TO SUPPORT ANY
CONSTRUCTION MATERIALS
1 1/2" ± 1"8"@W126"@W10T&B1 1/2"WELDING CLEARANCES
TRIM FLG T&B, ONE SIDE
ONLY, AS REQD FOR FIELD
2"8"2"2"4"4"2"EMBED & BEAM CL
BEAM ELEVATION
EMBED ELEVATION
OF ANGLE
DO NOT WELD
ACROSS TOP
5/16
3/4" RETURN
TOP, FULL
RETURN
BOT
5/16
3 SIDES,
NOTE 1
1 1/2"2"8"2"MIN3"SEE FOR
EMBED PL AT
TOP OF WALL
1/S501
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:53 PMS500
STEEL DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
NO SCALE10 GARAGE HEADER POST BEARING
NO SCALE3 TYP COL TRANSFERNO SCALE12 TYP COL BASE PLATE
NO SCALE1 WF BEAM TO HSS COL CONN
NO SCALE2 WF BEAM TO WF BEAM CONN
NO SCALE4 TYP BM OVER COLUMN
NO SCALE6 TYP BEAM DBL ANGLE SPLICE - LFRD
NO SCALE7 BEAM TO BEAM CONN - 1
NO SCALE5 TYP BEAM ANGLES
NO SCALE8 STEEL BEAM EMBED AT CONC WALL
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
MARK HOLDOWN TYPE
6
ANCHOR RQMTS MINIMUM
ATTACHMENT REMARKS
HOLDOWN SCHEDULE
MARK STUDS
W1-A
SHEATHING BLOCKED
EDGES
EDGE
NAILING
STRUCTURAL WOOD WALL SCHEDULE
REMARKS
1/2" GYP BD EA FACE NO 5d @ 4" OC
7
W1-B
1 1/2x5 1/2 LSL @ 16"OC
1/2" APA RATED
PLYWOOD YES 10d @ 6" OC
WOOD WALL TYPE
SEE: SCHED
W1-A1
HOLDOWN TYPE
SEE: SCHED
STRUCTURAL WALL NOTES:
1. ALL STRUCTURAL WOOD WALLS SHALL BE W1-A, UNO.
2. PLYWOOD SHEATHING TO BE APA-RATED SHEATHING. SEE: GENERAL NOTES
FOR ADDITIONAL INFORMATION.
3. PLYWOOD SHEATHING NAILS SHALL BE INSTALLED A MINIMUM OF 3/8" FROM
PANEL EDGES.
4. PLYWOOD SHEATHING NAILS TO BE GALVANIZED COMMON.
5. AT PLYWOOD SHEATHING, USE 10d NAILS @ 12" OC FOR FIELD NAILING.
6. ALL PLYWOOD SHEATHING TO BE BACKED WITH 2" NOMINAL OR WIDER
MEMBER.
7. PROVIDE A MINIMUM OF (2) STUDS AT EACH HOLDOWN.
8. CONNECT SHEAR PANELS DIRECTLY TO STUDS.
9. ALL WALL NAILING AT WALLS, INCLUDING HEADERS, BLOCKING, RIMBOARDS,
ETC. SHALL CONFORM TO REQUIREMENTS OF NAILING SCHEDULE IN IBC 2012,
TABLE 2304.9.1 UNLESS MORE STRINGENT REQUIREMENTS ARE SHOWN IN
DRAWINGS.
SHEAR WALL KEY
HOLDOWN NOTES:
1. INSTALL ALL HOLDOWNS AND HOLDOWN ANCHORS PER MNFR's WRITTEN
INSTRUCTIONS.
2. UNLESS OTHERWISE NOTED, MINIMUM HOLDOWN ATTACHMENT TO BE (2) 2x ~
MATCH WALL STUD THICKNESS. PROVIDE ADDITIONAL STUDS AS NEEDED AT
HOLDOWN TO MEET MANUFACTURE REQUIREMENTS OF MINIMUM MEMBER
THICKNESS
ANCHORAGE TO FDN
5/8"Ø @ 48"OC HDG w/12" EMBED
5/8"Ø @ 48"OC HDG w/12" EMBED
FIELD NAILING PER
NOTES
2x BLKG AT SHEATHING
EDGES (WHERE
REQUIRED PER
SCHEDULE)
EDGE NAILING PER
SCHEDULE
EDGE NAILING
SHEATHING PER SCHEDULE ~
STAGGER EDGES AS SHOWN
STUD SIZE & SPACING PER
SCHEDULE
ANCHORAGE TO
FDN
CONNECTION AT
SILL PLATE
CONNECTION AT
TOP PLATE
16d @ 3"OC
16d @ 4"OC SIMPSON LS50
@24" OC
SIMPSON LS50
@24" OC
0 NO HOLD DOWN
8
SIMPSON HDU2-SDS2.5
{STUDS &
SPACING
W1-C YES 10d @ 4" OC 5/8"Ø @ 36"OC HDG w/12" EMBED 16d @ 2"OC SIMPSON LS50
@16" OC
SIMPSON SSTB16
W1-D 10d @ 4" OC (EXT)
5d @ 4" OC (INT)5/8"Ø @ 24"OC HDG w/12" EMBED (2) ROWS 16d @ 3"OC
SIMPSON LS50
@12" OCYES
9
SIMPSON HDU4-SDS2.5 SIMPSON SB5/8x24
SIMPSON HDU5-SDS2.5 SIMPSON SB5/8x24
SIMPSON HDU8-SDS2.5 SIMPSON SSTB28 (3) LSL STUDS
ANCHOR BOLTS TO BE HDG
ANCHOR BOLTS TO BE HDG
ANCHOR BOLTS TO BE HDG
ANCHOR BOLTS TO BE HDG
W1-E YES 10d @ 2" OC 5/8"Ø @ 16"OC HDG w/12" EMBED
SIMPSON LS70
@12" OC
W2-B YES 10d @ 6" OC 5/8"Ø @ 48"OC HDG w/12" EMBED 16d @ 3"OC SIMPSON LS50
@24" OC
1/2" APA RATED
PLYWOOD
1/2" APA RATED
PLYWOOD (EXTERIOR)
1/2" GYP BD (INTERIOR)
1/2" APA RATED
PLYWOOD
1 1/2x5 1/2 LSL @ 16"OC
1 1/2x5 1/2 LSL @ 16"OC
1 1/2x5 1/2 LSL @ 16"OC
1 1/2x5 1/2 LSL @ 16"OC
1 1/2x7 1/4 LSL @ 16"OC 1/2" APA RATED
PLYWOOD
(2) ROWS 16d @ 2"OC
5 (2) SIMPSON MSTC 66 -- (2) LSL STUDS
(2) LSL STUDS
(2) LSL STUDS
(2) LSL STUDS
--
4 (2) SIMPSON MSTC 52 -- (2) LSL STUDS --
3 SIMPSON MSTC 66 -- (2) LSL STUDS --
2 SIMPSON MSTC 52 -- (2) LSL STUDS --
1 SIMPSON MSTC 28 -- (2) LSL STUDS --
CONN AT SILL PLATE
PER 1/S610
1
HORIZONTAL DIAPHRAGM SCHEDULE
MARK SHEATHING MATERIAL BLOCKED EDGES FASTENER TYPE & SPACING
5/8" THICK 20/40 APA-
RATED PLYWOOD NO
NO
3/4" THICK 24OC STURD-I-
FLOOR APA-RATED
SHEATHING
YES
NOTES:
1. MINIMUM EDGE DISTANCE FOR NAILS SHALL BE 3/8".
2. PROVIDE BOUNDARY NAILING (TYPE 4 ABOVE) INTO ALL SUPPORTING BEAMS, WALLS,
JOIST BLOCKING, AND RIM BOARDS UNO.
WS1
WS2
WS3
1 10d @ 6" OC
2 10d @ 12" OC
3 NA
4 10d @ 6" OC
1 10d @ 6" OC
2 10d @ 12" OC
3 10d @ 6" OC
4 10d @ 6" OC
1 10d @ 6" OC
2 10d @ 12" OC
3 NA
4 10d @ 6" OC
2
1 PANEL EDGE NAILING AT SUPPORTED EDGES
2 FIELD NAILING
3 PANEL EDGE NAILING AT BLOCKED EDGES
4 BOUNDARY NAILING
BEAM OR WALL
DIAPHRAGM EDGE
TRUSSES, RAFTERS
OR JOISTS
2x FLAT BLOCKING AT
UNSUPPORTED
SHEATHING EDGES
(WHERE REQD ~ SEE
SCHEDULE)
1
3
4
5/8" THICK 20/40 APA-
RATED PLYWOOD
NOTES:
1. VERIFY SETBACK DIMENSIONS SHOWN ABOVE WITH HOLD DOWN MANUFACTURER.
2. NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO INSTALLING ANCHORS.
3. ANCHORS SHALL BE LOCATED AT CENTER OF SILL PLATE, UNO.
4. POST CONNECTORS ARE SIMPSON SDS SCREWS, OR EQUIVALENT, UNO.
5. SEE: FOR STEEL STRAP DETAILS AND ADDNL INFO.
SILL PLATE
HOLD DOWN,
SEE HOLD DOWN
SCHEDULE
SHEAR WALL POST
ANCHOR BOLTMNFRSTAND-OFFAS REQD BYSEE SCHED
SET BACK,EMBEDMENT1/S603
NOTES:
1. PROVIDE A MINUMUM OF (2) STUDS AT EACH BEAM SUPPORT IF NO POST IS
DESIGNATED.
2. ALL MULTIPLE STUD POSTS SHALL BE NAILED TOGETHER AS SHOWN IN DIAGRAM.
3. WHERE NAILS ARE USED, EACH ADDITIONAL STUD IS NAILED TO REMAINDER OF STUD
PACK SHOWN BELOW.
10d NAIL THRU EA
STUD, TYP
9" TYPEA END4" TYP1 1/2".
2 1/2".
. 1 1/2"
1-1/2"
2-1/2"
1-1/2"
CONNECTION FASTENING
JOIST TO SILL OR GIRDER (3) 8d COMMON (2 1/2"x0.131")
(3) 3"x0.131" NAILS
LOCATION
TOENAIL
BRIDGING TO JOIST (3) 8d COMMON (2 1/2"x0.131")
(3) 3"x0.131" NAILS
TOENAIL EA END
1"x6" SUBFLOOR OR LESS TO EA
JOIST
(2) 8d COMMON (2 1/2"x0.131") FACE NAIL
WIDER THAN 1"x6" SUBFLOOR TO
EA JOIST
(3) 8d COMMON (2 1/2"x0.131") FACE NAIL
2" SUBFLOOR TO JOIST OR GIRDER (2) 16d COMMON (3 1/2"x0.162") BLIND & FACE NAIL
SOLE PLATE TO JOIST OR BLOCKING 16d (3 1/2"x0.135") @ 16"OC
3"x0.131" NAILS @ 8"OC
TYP FACE NAIL
TOP PLATE TO STUD (2) 16d COMMON (3 1/2"x0.162")
(3) 3"x0.131" NAILS
END NAIL
STUD TO SOLE PLATE (4) 8d COMMON (2 1/2"x0.131")
(4) 3"x0.131" NAILS
TOE NAIL
END NAIL
DOUBLE STUDS 16d (3 1/2"x0.135") @ 16"OC
3"x0.131" NAILS @ 8"OC
FACE NAIL
(2) 16d COMMON (3 1/2x0.162")
(3) 3"x0.131" NAILS
BLOCKING BTWN JOISTS OR
RAFTERS TO TOP PLATE
TOENAIL
RIM JOIST TO TOP PLATE 8d (2 1/2"x0.131") @ 6"OC
3"x0.131" NAILS @ 8"OC
TOE NAIL
CEILING JOISTS
(TO PLATE)
TOE NAIL
CEILING JOISTS
(LAPS OVER PARTITION)
(3) 16d COMMON (3 1/2"x0.135")
(4) 3"x0.131" NAILS
FACE NAIL
CEILING JOISTS
(TO PARALLEL RAFTERS)
FACE NAIL
RAFTER TO PLATE FACE NAIL
(3) 8d COMMON (2 1/2"x0.131")
(3) 3"x0.131" NAILS
(3) 8d COMMON (2 1/2"x0.131")
(5) 3"x0.131" NAILS
(3) 16d COMMON (3 1/2"x0.135")
(4) 3"x0.131" NAILS
(3) 8d COMMON (2 1/2"x0.131")
(3) 3"x0.131" NAILS
TYP WOOD MEMBER FASTENING SCHEDULE
JACK RAFTER TO HIP TOENAIL(3) 10d COMMON (3"x0.148")
(4) 3"x0.131" NAILS
FACE NAIL(2) 16d COMMON (3 1/2"x0.162")
(3) 3"x0.131" NAILS
JOIST TO BAND JOIST FACE NAIL(3) 16d COMMON (3 1/2"x0.135")
(4) 3"x0.131" NAILS
NOTES:
1. TYP WOOD MEMBER FASTENING REQUIREMENTS ARE TAKEN FROM IBC 2012, TABLE 2304.9.1.
2. THE ABOVE FASTENING REQUIREMENTS ARE A MINIMUM, AND SHOULD BE APPLIED ONLY TO
TYPICAL SITUATIONS.
3. THE ABOVE IS ONLY A SUMMARY OF THE TABLE 2304.9.1, PLEASE REFERENCE IBC FOR
COMPLETE FASTENING SCHEDULE.
JOIST/BEAM
FACE MOUNT
HANGER
TOP FLANGE
HANGER
WOOD HANGER SCHEDULE
NOTES:
1. ALL HANGERS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE.
2. ALL TJI'S ARE TO HAVE WEB STIFFENERS AT HANGERS UNLESS NOTED OTHERWISE
2x8 LUS26 JB28
2x10 LUS28 JB210
2x12 LUS210 JB212
11 7/8" TJI-210
(AT RIDGE)
-- LBV2.1/11.88
11 7/8" TJI-360 (AT
SLOPED ROOF)
-- LBV2.37/11.88
11 7/8" TJI-210 ITS2.06/11.88
11 7/8" TJI-360
11 7/8" TJI-560 IUS3.56/11.88
7 1/4" LVL HU7 LBV1.81/7.25
9 1/2" LVL HU7 LBV1.81/9.5
11 7/8" LVL HUS1.81/10 LBV1.81/11.88
(2) 11 7/8" LVL HU412 BA3.56/11.88
(3) 11 7/8" LVL HU612 WP5.50/11.88
ITS2.37/11.88
ITS3.56/11.88
IUS2.37/11.88
IUS2.06/11.88
5 1/2" LVL HU1.81/5 --
3 5/8" MAX
VERTICAL LEG OF
ANGLE TIGHT TO BACK
OF VENEER
VENEER TIES
STONE VENEER LOOSE LINTEL SCHEDULE
REMARKSLINTELOPENING LENGTH, L
LLV6"
LLV6"
LLV6"
4"
BEARING EE
L ≤ 6'-0" L3 1/2x3 1/2x1/4
10'-0" < L ≤ 12'-0"
6'-0" < L ≤ 8'-0"
8'-0" < L ≤ 10'-0"
BENT PL 5/16X8X3 1/2
L6x3 1/2x5/16
L5x3 1/2x1/4
-
STRUCTURAL WALL
SYSTEM
8" MAXNOTE:
- STONE VENEER LOOSE LINTEL SHALL BE HDG
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:55 PMS601
TYPICAL WOOD DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
NO SCALE5 TYP WOOD STRUCTURAL WALL & HOLDOWN SCHEDULESNO SCALE8 TYP WOOD HORIZONTAL DIAPHRAGM
SCHEDULE
NO SCALE3 TYP WOOD HOLD DOWN AT FNDNO SCALE6 TYP WOOD POST
NO SCALE11 TYP WOOD MEMBER FASTENING
SCHEDULE
NO SCALE9 WOOD HANGER SCHEDULENO SCALE12 TYP VENEER LOOSE LINTEL
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015
JOIST HANGER PER
WEB STIFFENER EA
FACE
CONTINUOUS 1.75x11.875"
LSL LEDGER W/ (2) 5/8"Ø
EXP ANCHORS @ 32" OC
CONC WALL
9/S6016 1/2"3"DIAPHRAGM EDGE
NAILING
MIN 4 1/2" EMBED
SIMPSON LCE4 W/ MAX
NUMBER OF NAILS PER
MNFR, AT LVL TO PSL
BEARING CONNECTION
K
MAXIMUM UNIFORM LOAD APPLIED TO OUTSIDE BEAM (PLF)
A 470
C
B 355
-
NOTES:
1. BOLTS ARE A307-36. BOLT HOLES = SAME DIAMETER AS BOLT.
2. USE WASHERS @ HEAD & NUT.
3. USE (2) ROWS OF FASTENERS FOR BEAMS < 12" NOMINAL.
MULTIPLE
ASSEMBLY
TYPE
(3) ROWS 16d 3-1/2"
COMMON WIRE @
16" O.C.
(3) ROWS 16d 3-1/2"
COMMON WIRE @
12" O.C.
(3) ROWS 1/2"
BOLTS @ 24" O.C.
(3) ROWS 1/2"
BOLTS @ 12" O.C.
705
530
-
503
380
340
1010
760
680
ASSEMBLY A
(2) PCS. @ 1-3/4"2"2"ASSEMBLY B
(3) PCS. @ 1-3/4"2"2"ASSEMBLY C
(4) PCS. @ 1-3/4"2"2"7" WIDE BEAMS SHOULD ONLY BE
USED WHEN LOADS ARE APPLIED
TO BOTH SIDES OF THE MEMBER
(TO MINIMIZE ROTATION).
MARK 1 2 3 4
PL 3/8 EA FACE, TYP SPACE
BTWN PLATES SHALL
EQUAL BM WIDTH +1/8"
BACK PL 3/8, TYP
BOT PL 3/8, TYP
TYP
1/4TYP
1/4TYP3 3/4"3"1 1/4"1 1/2"3 1/2"TRIMMER(S)TRIMMER(S)3'-4"
CONTINUE FLUSH HEADER TO
TRIMMER(S) EACH SIDE OF
OPENING
ELEVATION
PLAN
LSL RIM OR CONT
FLUSH HEADER
AT PERP JOIST,
PROVIDE JOIST
HANGER PER 9/S601 11 7/8"3'-4"
FLUSH HEADER
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:09/22/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt9/22/2015 3:37:55 PMS602
TYPICAL WOOD DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
NO SCALE1 TYP WOOD JOIST AT CONC WALL
NO SCALE2 LVL BM TO POST CONN
NO SCALE3 MULTIPLE-MEMBER CONNECTION
NO SCALE4 TYP WOOD BEAM AT CONT COLUMN
NO SCALE5 FLUSH HEADER
No. Description Date
PERMIT SET 07.02.2015
1 FND SET 09.22.2015