HomeMy WebLinkAboutB15-0250_M002_1442254080.pdfEXHAUST FAN SCHEDULE MARK TYPE FAN MOTOR MANUFACTURER* & MODEL # ACCESSORIES REMARKS CFM SONES ESP HP/ (WATT) VOLT/ PHASE @ S.L. (IN WC) @ ALT (IN WC) EF-1 CEILING 50 2.0 0.3 0.25 15W 120/1 PANASONIC WHISPER CEILING FV-08VQ5 BACKDRAFT DAMPER CONTROLLED FROM DEDICATED WALL SWITCH EF-2 CEILING 120 2.0 0.3 0.25 28.4W 120/1 PANASONIC WHISPER CEILING FV-15VQ5 BACKDRAFT DAMPER CONTROLLED FROM DEDICATED WALL SWITCH EF-3 CEILING 200 2.0 0.3 0.25 64W 120/1 PANASONIC WHISPER CEILING FV-30VQ3 BACKDRAFT DAMPER GARAGE EXHAUST, RUNS CONTINUOUSLY KEF-1 KITCHEN HOOD 1200 - - - - 120/1 BY OTHERS - - MANUFACTURERS: * ACME, COOK, GREENHECK, PENN GENERAL NOTES: A: B: HEAT EXCHANGER SCHEDULE MARK SERVICE TYPE SIDE GPM FLUID E.W.T. (°F) L.W.T. (°F) MAX PRESSURE DROP (PSI) FOULING FACTOR HEAT TRANSFER (MBH) MANUFACTURER* & MODEL # ACCESSORIES REMARKS HX-1 SNOWMELT BRAZED PLATE HOT - 20% PROP. GLYCOL 140 110 - -- - - - COLD - 50% PROP. GLYCOL -- - MANUFACTURERS: * B&G, PATTERSON-KELLY, TACO, TRANTER GENERAL NOTES: A: B: MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULE MARK SERVICE TYPE CAPACITY ELECTRICAL MANUFACTURER* & MODEL # ACCESSORIES REMARKS HP VOLT/ PH ---- - - - --- --- - - - MANUFACTURERS: * GENERAL NOTES: A: B: PLUMBING FIXTURE SCHEDULE SYMBOL TYPE A.D.A. FINISH MANUFACTURER* & MODEL # FAUCET TRIM MFR.* & MODEL # ACCESSORIES REMARKS FLOOR SINK N/A - Z-1900 - - - FLOOR DRAIN N/A - Z-415B - - - HOSE BIBB N/A RE: ARCH RE: ARCH - - - TOILET N/A RE: ARCH RE: ARCH - - - LAVATORY N/A RE: ARCH RE: ARCH - - - SHOWER N/A RE: ARCH RE: ARCH - - - WASHER BOX N/A RE: ARCH RE: ARCH - - - KITCHEN SINK N/A RE: ARCH RE: ARCH - - - KITCHEN ISLAND SINK N/A RE: ARCH RE: ARCH - - - MANUFACTURERS: FIXTURE: AMERICAN STANDARD, UNIVERSAL RUNDLE, FIAT STERN WILLIAMS FAUCET: SPEAKMAN, DELTA, AMERICAN STANDARD, CHICAGO DRAIN: JOSAM, WADE SMITH GENERAL NOTES: A: B: P1 P2 P3 P4 P5 P6 P7 P8 P9 FAN COIL SCHEDULE (HYDRONIC HEAT/DX COOL) MARK SERVICE TYPE FAN COOLING COIL HEATING COIL FILTER MANUFACTURER* & MODEL # ACCESSORIES REMARKS CFM O.S.A. CFM ESP ELECTRICAL AIR CONDITIONS AIR CONDITIONS WATER CONDITIONS @ S.L. (IN WC) @ ALT (IN WC) HP VOLT/ PH E.A.T. DB/WB (°F) L.A.T. DB/WB (°F) TOTAL MBH E.A.T. DB (°F) L.A.T. DB (°F) SENSIBLE MBH E.W.T. (°F) L.W.T. (°F) GPMMAX.WTR P.D. (FT.) FC-1HEARTH/DINING/ENTRY HORIZ. DRAW THRU 2000 500 0.5 0.4 1 208/1 80 55 40 50 95 72 140 110 5 1 2" TRANE BCHD 072 A,B,C,D,F,G,H - FC-2 KITCH/FAM HORIZ. DRAW THRU 2000 500 0.5 0.4 1 208/1 80 55 40 50 95 72 140 110 5 1 2" TRANE BCHD 072 A,B,C,D,F,G,H - FC-3 MASTER BED/BED4 HORIZ. DRAW THRU 1000 200 0.3 0.25 1 208/1 80 55 20 50 95 36 140 110 3 10 2" TRANE BCHD 036 A,B,C,D,E,G,H FC-4 BAR/BED1 HORIZ. DRAW THRU 1000 200 0.5 0.4 1 208/1 80 55 20 50 95 36 140 110 3 10 2" TRANE BCHD 036 A,B,C,D,E,G,H - FC-5 BED2/BED3/OFFICE HORIZ. DRAW THRU 1200 200 0.3 0.25 1 208/1 80 55 24 55 95 38.4 140 110 3 10 2" TRANE BCHD 036 A,B,C,D,E,G,H - MANUFACTURERS: * CARRIER, ENVIROTEC, MCQUAY GENERAL NOTES: A: 1" FOIL FACE INSULATION B: PVC DRAIN PAN C: ANGLE/FILTER MIXING BOX WITH MERV 8 FILTERS, AND MODULATING, NC DAMPERS D: TRACER ZN520 CONTROLLER E: 2-WAY MODULATING CONTROL VALVE F: 3-WAY MODULATING CONTROL VALVE G: 6-ROW DX COIL H: 1-ROW HEATING WATER COIL OUTDOOR CONDENSING UNIT SCHEDULE OUTDOOR CONDENSING UNIT ACCESSORIES REMARKS MARK DUTY CAPACITY (TONS) AMBIENT TEMP. DB (°F) LOW AMB. CONTROL DB (°F) ELECTRICAL SEER MANUFACTURER* & MODEL # MCA VOLT/ PH MOCP CU-1 4 95 40 28 208/1 45 17 TRANE XR17-4TTR7048A1000A REFRIGERANT LINESET, LOW AMBIENT KIT - CU-2 4 95 40 28 208/1 45 17 TRANE XR17-4TTR7048A1000A REFRIGERANT LINESET, LOW AMBIENT KIT - CU-3 2 95 40 18 208/1 20 17 TRANE XR17-4TTR7024A1000B REFRIGERANT LINESET, LOW AMBIENT KIT - CU-4 2 95 40 18 208/1 20 17 TRANE XR17-4TTR7024A1000B REFRIGERANT LINESET, LOW AMBIENT KIT - CU-5 2 95 40 18 208/1 20 17 TRANE XR17-4TTR7024A1000B REFRIGERANT LINESET, LOW AMBIENT KIT MANUFACTURERS: * * GENERAL NOTES: A: B: PERMIT SET Project number Date Drawn by 8/13/2015 2:05:16 PM M002 MECHANICAL SCHEDULES HUGHES LOT 3 / 994 PTARMIGAN RD VAIL,CO Hughes Residence 06.29.15 DAL 1 No. Description Date 1 REV 1 - PERMIT COMMENTS 8.07.2015 09/14/15