Loading...
HomeMy WebLinkAboutB15-0250_M003_1442254080.pdfRADIANT MANIFOLD SCHEDULE ZONE DESCRIPTION AREA (SQ. FT.) GPM ESTIMATED # OF LOOPS LOOP SPACING @ EXT.WALL MAX LOOP PRESSURE LOSS (PSI) FLOOR COVERING ACCESSORIES REMARKS RZ1-1 - 700 - - - - - - - RZ1-2 - 215 - - - - - - - RZ1-3 - 585 - - - - - - - RZ1-4a - 230 - - - - - - - RZ1-4b - 155 - - - - - - - RZ1-5a - 260 - - - - - - - RZ1-5b - 125 - - - - - - - RZ2-1 - 370 - - - - - - - RZ2-2a - 150 - - - - - - - RZ2-2b - 100 - - - - - - - RZ2-3 - 280 - - - - - - - RZ2-4 - 990 - - - - - - - RZ2-5 - 275 - - - - - - - RZ3-1a - 180 - - - - - - - RZ3-1b - 165 - - - - - - - RZ3-2 - 210 - - - - - - - RZ3-3 - 105 - - - - - - - RZ3-4a - 210 - - - - - - - RZ3-4b - 100 - - - - - - - RZ3-5a - 165 - - - - - - - RZ3-5b - 130 - - - - - - - RZ3-6a - 320 - - - - - - - RZ3-6b - 125 - - - - - - - MANUFACTURERS: * GENERAL NOTES: A: B: BOILER SCHEDULE MARK SERVICE BOILER TYPE FUEL TYPE HEATING CAPACITY L.W.T. (°F) E.W.T. (°F) BURNER VENT TYPE MANUFACTURER* & MODEL # ACCESSORIES REMARKS INPUT @ S.L. (MBH) OUTPUT @ ALT. MINIMUM A.F.U.E. HP VOLT/ PH B-1a HYDRONIC HEAT CONDENSING NATURAL GAS 399 377 94 140 110 20A 120/1 DIRECT LOCHINVAR WHN399 - - B-1b HYDRONIC HEAT CONDENSING NATURAL GAS 399 377 94 140 110 20A 120/1 DIRECT LOCHINVAR WHN399 - - MANUFACTURERS: * LOCHINVAR, TRIANGLE TUBE, PATTERSON KELLY, VIESSMANN OR BUDERUS GENERAL NOTES: A: B: GRILLE, REGISTER, DIFFUSER & LOUVER SYMBOL USE PATTERN FINISH MANUFACTURER* & MODEL # ACCESSORIES REMARKS SIDEWALL SUPPLY 2-WAY RE: ARCH - OBD - CEILING SUPPLY 4-WAY RE: ARCH - OBD - RA - RE: ARCH - OBD - OSA - RE: ARCH RUSKIN - - MANUFACTURERS: GRD KRUEGER, METALAIRE, TITUS LOUVER GREENHECK, L&D, RUSKIN GENERAL NOTES: A: B: A B C D E PUMP SCHEDULE MARK SERVICE TYPE GPM TDH (FT) FLUID MOTOR MANUFACTURER* & MODEL # ACCESSORIES REMARKS HP RPM VOLT/ PH HWBP-1 DOMESTIC HOT RECIRC IN-LINE 5 10 WATER - - - GRUNDFOS ALPHA - - BP-1 - IN-LINE 30 5 20% GLY - VFD - - - - WHCP-1 - IN-LINE 14 10 20% GLY - - - - - - HWP-1 - IN-LINE 30 30 20% GLY - VFD - GRUNDFOS MAGNA3 - - SMP-1 SNOWMELT IN-LINE 40 30 50% GLY - - - - - - MANUFACTURERS: * B&G, GRUNDFOS, TACO OR AURORA EQUIVALENT GENERAL NOTES: A: B: SNOWMELT MANIFOLD SCHEDULE ZONE DESCRIPTION APPROX AREA (SQ. FT.) GPM ESTIMATED # OF LOOPS MAX LOOP PRESSURE LOSS (PSI) ACCESSORIES REMARKS MANUFACTURERS: * GENERAL NOTES: A: B: INDIRECT FIRED WATER HEATER SCHEDULE MARK SERVICE TYPE SIDE FLOW FLUID E.W.T. (°F) L.W.T. (°F) MAX PRESSURE DROP (FT) STORAGE CAPACITY (GAL.) MANUFACTURER* & MODEL # ACCESSORIES REMARKS WH-1a DOMESTIC INDIRECT DOM N/A - 40 140 N/A 80 LOCHINVAR SIT080 266 GPH; 160 MBH - HWS/R 14 20% GLY 180 150 5.7 WH-1b DOMESTIC INDIRECT DOM N/A - 40 140 N/A 80 LOCHINVAR SIT080 266 GPH; 160 MBH - HWS/R 14 20% GLY 180 150 5.7 MANUFACTURERS: * TRIANGLE TUBE, WEIL-MCLAIN, BUDERUS, LOCHINVAR, AO SMITH, BRADFORD WHITE. GENERAL NOTES: A: NOT FOR CONSTRUCTION Project number Date Drawn by 7/5/2015 6:40:25 PM M003 MECHANICAL SCHEDULES HUGHES-1 LOT 3 / 994 PTARMIGAN RD VAIL,CO Hughes Residence 06.29.15 DAL No. Description Date PERMIT SET 09/14/15