HomeMy WebLinkAboutB15-0250_M302_1442254080.pdfDN
DN
DN
UP H B
H B
P3
P3
G TO BBQ.
5 6 2 7
3 4
A
B
C
G
H
K
L
M
E
D
J
F
P5 P5
3/4"G TO FIRE
PLACE.
P4
P8
P8
P9
P8
P5
P4
1"CW, 1"HW, &
1/2"HWC DN.
V
V CW
HW
HWC
V
V
V
P6
V _"CW, _"HW,
& _"HWC
RISERS.
V
_"CW, _"HW,
& _"HWC
RISERS.
3/4"G TO FIRE PLACE.
PERMIT SET
Project number
Date
Drawn by 8/13/2015 2:05:51 PM
M302
LEVEL 2 PLUMBING PLAN
HUGHES
LOT 3 / 994 PTARMIGAN RD
VAIL,CO
Hughes Residence
06.29.15
DAL
1/4" = 1'-0"
1
LEVEL 2 PLUMBING PLAN
RE: _/M_ FOR CLEANOUT DIAGRAMS.
RE: _/M_ FOR ISLAND VENT DIAGRAM.
RE: _/M_ FOR TRAP PRIMER CONNECTION.
REFER TO THE PLUMBING FIXTURE
CONNECTION SCHEDULE FOR PIPE SIZES TO
INDIVIDUAL FIXTURES.
NOT ALL REQUIRED CLEANOUTS ARE
NECESSARILY SHOWN ON THESE PLANS.
PROVIDE CLEANOUTS ON WASTE, VENT AND
STORM PIPING AS REQUIRED BY CODE AND
FOR REASONABLE MAINTENANCE BASED ON
ACTUAL FIELD INSTALLATION. COORDINATE
LOCATIONS WITH ARCHITECT/ENGINEER.
COORDINATE ROUTING OF CONDENSATE
DRAIN LINES WITH ARCHITECT PRIOR TO
INSTALLATION.
PIPING ON EXTERIOR WALLS OR PRE-CAST
CONCRETE WALLS TO BE ROUTED IN FRAMED
WALL ON INTERIOR SIDE OF INSULATION.
ST AND ST(OF) PIPING 3", UNO
INSTALL THERMOSTATIC MIXING VALVES,
ASSE 1070 LISTED, AT EACH PUBLIC
HANDWASHING LAVATORY/SINK. SIZE TO
MATCH HW PIPE SIZE.
ROOF OVERFLOW DRAINAGE STRATEGY TO
BE DETERMINED OR VIA ARCHITECTURAL
SCUPPERS UNO
TERMINATE PLUMBING VENTS NOT LESS
THAN 12" ABOVE ROOF.
AVOID ROUTING PIPING OVER ELECTRICAL
ROOMS OR ELECTRICAL PANELS; MAINTAIN
N.E.C. CLEARANCES. COORDINATE
ROUTINGS WITH ELECTRICAL CONTRACTOR.
CONTRACTOR TO MAINTAIN 8'-6" CLEAR HEAD
HEIGHT IN GARAGE AND INFORM THE
ENGINEER AND ARCHITECT OF ANY AREAS
THAT MAY NOT MEET 8'-6" PRIOR TO
INSTALLATION, MINIMUM 8'-2" CLEAR HEAD
HEIGHT MUST BE MAINTAINED IN
ACCESSIBLE VEHICLE AREAS.
PROVIDE FLEXIBLE PIPE CONNECTIONS TO
ALL MOTORIZED EQUIPMENT.
ROUTE DOMESTIC HOT WATER RECIRC TO
WITHIN 10 FEET OF ALL HOT WATER FIXTURES.
CONNECT WITHIN 5 FEET OF 0.5 GPM AND
LOWER FAUCETS.
VERIFY ALL EQUIPMENT ACCESS PANELS
WITH MANUFACTURER AND ARCHITECT.
PROTECT PIPING ROUTED ALONG COLUMNS,
WALLS, ETC. FROM DAMAGE AS NECESSARY
WITH CAGES. COORDINATE WITH ARCHITECT.
PEX PIPING SHALL NOT BE ALLOWED TO
PENETRATE FIRE BARRIERS WHERE FIRE
CAULKING IS REQUIRED.
ALL VALVES SHALL BE INSTALLED ABOVE
DROP-IN CEILINGS IN ACCESSIBLE
LOCATIONS, OR WITH ACCESS PANELS IN
HARD-LID CEILINGS.
ALL PIPING SHALL BE ROUTED AS HIGH AS
POSSIBLE IN THE CEILING SPACE. UTILIZE
JOIST SPACE WHEN POSSIBLE, ESPECIALLY
WHERE CROSSING OTHER PIPES, DUCTS,
AND ELECTRICAL.
ACCESS PANELS SHALL BE 24x24, UNO
LOCATIONS SHOWN ARE APPROXIMATE,
EXACT LOCATIONS SHALL BE COORDINATED
WITH THE ARCHITECTS DRAWINGS AND WITH
THE LOCATIONS OF THE EQUIPMENT OR
APPARATUS THAT THEY SERVE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
NOTES:
No. Description Date
09/14/15