HomeMy WebLinkAboutB15-0250_M500_1442254080.pdfGRADE METER UNION PRV BY UTILITY. SHUT-OFF VALVE. BUILDING GAS PIPING TO METER SET BY UTILITY. TO BUILDING. SEE PLANS FOR CONTINUATION. _" DESIGNER NOTE: VERIFY ENTRANCE DIAGRAM WITH CONNECTING UTILITY COMPANY. M GAS ENTRANCE DIAGRAM NO SCALE ISLAND VENT DIAGRAM NO SCALE W V FLOOR V DRAINBOARD 2" SLOPE 2" C.O. SLOPE 1. EXTEND VENT AS HIGH AS POSSIBLE BUT NOT LESS THAN THE DRAINBOARD HEIGHT & THEN RETURNING IT DOWNWARD & CONNECTING IT TO THE HORIZONTAL SINK DRAIN IMMEDIATELY DOWNSTREAM FROM THE VERTICAL FIXTURE DRAIN. 2. THE RETURNED VENT SHALL BE CONNECTED TO THE HORIZONTAL DRAIN THRU A Y-BRANCH FITTING & SHALL, IN ADDITION, BE PROVIDED WITH A FOOT VENT TAKEN OFF THE VERTICAL FIXTURE VENT BY MEANS OF A Y-BRANCH IMMEDIATELY BELOW THE FLOOR & EXTENDING TO THE NEAREST PARTITION & THEN THRU THE ROOF OR CONNECTED TO OTHER VENTS, IN AN APPROVED MANNER. 3. DRAINAGE FITTINGS SHALL BE USED ON ALL PARTS OF THE VENT BELOW THE FLOOR & A MIN. SLOPE OF 1/4"/FT BACK TO THE DRAIN SHALL BE MAINTAINED. 4. THE RETURN DRAIN UNDER THE DRAINBOARD SHALL BE A ONE PIECE FITTING OR AN ASSEMBLY OF A 45°, A 90°, & A 45° IN THE ORDER NAMED. 5. THE ISLAND SINK DRAIN, UPSTREAM OF THE RETURNED VENT, SHALL SERVE NO OTHER FIXTURES. VENT LINE NEAREST PARTITION. WALL CLEANOUT 11/2" 11/2" SINK DRAIN TO BUILDING SEWER. REQUIREMENTS SUPPLY DIFFUSER REMOTE BALANCE DAMPER DIAGRAM NO SCALE NOTE: CEILING DIFFUSER SHOWN. FLOOR DIFFUSER SIMILAR. INSULATED SUPPLY AIR PLENUM. 24" STANDARD CABLE OR AS REQUIRED. ROUND DAMPER. TAKE-OFF AS REQUIRED. PLENUM ADJUSTABLE MOUNTING CLAMP. DIFFUSER. ADJUSTS WITH 1/4" NUTDIRVER, SPECIFY OPTIONAL SCREWDRIVER TIP IF LESS THAN 3/8" NON-ACCESSIBLE BRANCH DUCT DAMPER BATHROOM WALL EXHAUST DIAGRAM NO SCALE BATHROOM EXHAUST DUCTS. RE: PLANS FOR SIZE AND QUANTITY. BACKDRAFT DAMPER, MOTORIZED DAMPER REQ'D FOR 300 CFM OR GREATER. 6" DEEP INSULATED PLENUM BOX. SEAL AIRTIGHT. REMOVABLE LOUVER. FACE OF EXTERIOR WALL. AS NOTED ON PLANS. INSULATE EXH DUCTS 24" INBOARD OF ENVELOPE. MIN. HEIGHT = MAX EXH DUCT DIAMETER + 2" BOTH SIDES. STUD SPACE RETURN AIR TRANSFER DUCT DIAGRAM RETURN GRILLE, TYP. SHEET METAL. CAULK AND PAN STUD CAVITY WITH STRUCTURE (NOT SHOWN). STUDS CONTINUE TO SEAL FOR AIRTIGHT CONNECTION, TYP. WALL FINISH BY ARCH. FLOOR STRUCTURE. RE: ARCH. INTERNALLY LINE STUD CAVITY WITH 1/2" ACOUSTICAL DUCT LINER. NO SCALE AIR CONTROL & EXPANSION TANK DIAGRAM NO SCALE HWS AIR PURGER W/ AIR VENT. HOSE END VALVE FOR SYSTEM FILL. DIAPHRAGM TYPE EXPANSION TANK. FROM BOILER, ETC. TO PUMP. NO SCALE ROUND DUCT TAKE-OFF DIAGRAM AIR FLOW USE DUCT SEALANT OR GASKETED FITTING ON HIGH VELOCITY DUCT. CONICAL SPIN-IN FITTING W/ MANUAL DAMPER, HANDLE, & LOCK NUT. FLEX DUCT. WORM DRIVE S.S. CLAMP. NOTE: DIAGRAM FOR LOW & HIGH VELOCITY DUCTWORK EXCEPT UPSTREAM OF VAV BOXES. OMIT DAMPER & FLEX DUCT UPSTREAM OF VAV BOXES. TYPICAL HANGER DIAGRAM NO SCALE ANCHOR, REFER TO STRUCTURAL. THREADED ROD. HANGER. PIPE. CONCRETE STRUCTURE. NOTE: ALL PIPING WITH INSULATION TO HAVE INSULATION RUN FULL SIZE THROUGH HANGER WITH SHIELD AND INSERT. DUCT MOUNTED REGISTER NO SCALE AIRFLOW DIRECTION SUPPLY MIN 6" RETURN AIRFLOW DIRECTION TURNED IN FLANGE. O.B.D. GRILLE. 45° ENTRY BOOT SEAL AT CONNECTION TO DUCT. HRV DUCT CONNECTIONS AND CLEARNACES DIAGRAM NO SCALE TOP VIEW FRONT VIEW LEFT VIEW RIGHT VIEW E-BOX EA FA EA FA OA RA OA RA FIELD PROVIDED SUPPORT FRAME, UNIT-STRUT OR EQUIV. PRIVDE SPRING VIB. ISOLATORS. ROUND HANGER ROD, TYP. FLEXIBLE CANVAS CONNECTOR, TYP. 4. PROVIDE FULL UNIT'S WIDTH OF CLEARANCE AT SIDE OF UNIT. SNOWMELT CONNECTION: STAIR TO WALK DIAGRAM NO SCALE 9" O.C. TYP. FOR ALL LANDINGS & WALKS. HYDRONIC SNOWMELT TUBING. NOTE: REFER TO ARCH. DWG #___ FOR STAIR DIMENSIONS. 6" O.C. TYP. FOR ALL STAIRS. CEILING FIRE ENTRY PIPING DIAGRAM F NO SCALE D FS D D F CLEANOUT DIAGRAMS NO SCALE 6" A B C D E F G I J K H M N L FAN COIL UNIT INSTALLATION NO SCALE D D FIRE DEPT. CONNECTION. EXTERIOR BLDG. WALL. TO FIRE PROTECTION SYSTEMS. TEST VALVE; PIPE TO OUTSIDE. FLOW SWITCH TO ALARMS, SEE SPECS. DRAIN VALVE; PIPE INDIRECT TO FLOOR DRAIN PER NFPA 25 REQUIREMENTS, TYP. SHUT-OFF VALVE. DOUBLE CHECK TYPE BACKFLOW PREVENTER. TAMPER SWITCHES ON VALVES. FIRE SERVICE FLANGE. FLOOR SINK BALL DRIP VALVE. C.W. SERVICE DIAGRAM SHOWN FOR REFERENCE ONLY, CONFIRM FINAL REQUIREMENTS WITH FIRE PROTECTION DESIGN BUILD CONTRACTOR AND ENGINEER OF RECORD. PRV SET @ 150 PSI SLOPE DN @ 1/4"/L.F. WASTE LINE FINISHED GRADE ADJUSTABLE GRADE CLEANOUT AND ACCESS ENCLOSURE WITH ANCHOR FLANGE, HEAVY DUTY TOP, AND VANDAL PROOF FASTENERS, ZURN, Z-1400-HD-KBRASS CLEANOUT PLUG W/COUNTER SUNK HEAD. ADJUSTABLE CLEANOUT AND ACCESS COVER ZURN ZB-1400. TOP OF COVER TO BE FLUSH W/ TOP OF FLOOR. 16" CONC. PAD TROWEL SMOOTH & EDGE. 1/8 C.I. BEND BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. FLOOR LINE 1/8 C.I. BEND C.I. WASTE LINE. LGTH TO SUIT. 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. PROVIDE FOLLOWING OPTIONS AS APPROPRIATE CARPET MARKER - FOR CARPETED AREAS. SQUARE TOP - FOR CERAMIC TILE OR SIMILAR SQUARE PATTERN FLOOR. FLASHING CLAMP - FOR ABOVE GRADE WATER PROOFED AREAS. SA FAN COIL UNIT RA FILTER W/ ACCESS PANEL. CONDENSATE DRAIN. PIPE INDIRECT TO APPROVED RECEPTOR (PROVIDE MIN. 2" DEEP TRAP). SHEET METAL DRAIN PAN. 3/4" SECONDARY DRAIN TO APPROVED RECEPTOR. PIPE INDIRECT TO FLOOR DRAIN ON SINK TAIL PIECE, TYP. ROUND HANGER ROD TYP. WITH EXCEPTION OF FAN COILS LOCATED IN ATTIC. SPRING VIBRATION ISOLATORS, TYP. DOUBLE LOCKNUT. NOTES: 1. RETURN AIR PLENUM FULL SIZE OF UNIT CONNECTION. 2. THIS SUPPORT SYSTEM IS NOT ALLOWED IN THE ATTIC. 3. LOCATE ATTIC FAN COILS ON 4" HOUSEKEEPING PAD WITH SPRING VIBRATION ISOLATORS. MOTORIZED DAMPER. MIXING BOX. OSA FLOOR CLEANOUT (FCO) CLEANOUT TO GRADE (COTG) NOT FOR CONSTRUCTION Project number Date Drawn by 7/5/2015 6:41:32 PM M500 MECHANICAL DIAGRAMS HUGHES-1 LOT 3 / 994 PTARMIGAN RD VAIL,CO Hughes Residence 06.29.15 DAL No. Description Date PERMIT SET 09/14/15