METER
UNION
PRV BY UTILITY.
SHUT-OFF VALVE.
BUILDING GAS
PIPING TO
METER SET BY
UTILITY.
TO BUILDING. SEE PLANS
FOR CONTINUATION.
_"
DESIGNER NOTE:
VERIFY ENTRANCE
DIAGRAM WITH
CONNECTING UTILITY
COMPANY.
M
GAS ENTRANCE DIAGRAM
NO SCALE
ISLAND VENT DIAGRAM
NO SCALE
W
V
FLOOR
V
DRAINBOARD
2"
SLOPE
2"
C.O.
SLOPE
1. EXTEND VENT AS HIGH AS POSSIBLE BUT NOT
LESS THAN THE DRAINBOARD HEIGHT & THEN
RETURNING IT DOWNWARD & CONNECTING IT TO
THE HORIZONTAL SINK DRAIN IMMEDIATELY
DOWNSTREAM FROM THE VERTICAL FIXTURE
DRAIN.
2. THE RETURNED VENT SHALL BE CONNECTED TO
THE HORIZONTAL DRAIN THRU A Y-BRANCH
FITTING & SHALL, IN ADDITION, BE PROVIDED
WITH A FOOT VENT TAKEN OFF THE VERTICAL
FIXTURE VENT BY MEANS OF A Y-BRANCH
IMMEDIATELY BELOW THE FLOOR & EXTENDING
TO THE NEAREST PARTITION & THEN THRU THE
ROOF OR CONNECTED TO OTHER VENTS, IN AN
APPROVED MANNER.
3. DRAINAGE FITTINGS SHALL BE USED ON ALL
PARTS OF THE VENT BELOW THE FLOOR & A MIN.
SLOPE OF 1/4"/FT BACK TO THE DRAIN SHALL BE
MAINTAINED.
4. THE RETURN DRAIN UNDER THE DRAINBOARD
SHALL BE A ONE PIECE FITTING OR AN
ASSEMBLY OF A 45°, A 90°, & A 45° IN THE ORDER
NAMED.
5. THE ISLAND SINK DRAIN, UPSTREAM OF THE
RETURNED VENT, SHALL SERVE NO OTHER
FIXTURES.
VENT LINE
NEAREST
PARTITION.
WALL CLEANOUT
11/2"
11/2"
SINK DRAIN TO BUILDING
SEWER.
REQUIREMENTS
SUPPLY DIFFUSER REMOTE BALANCE DAMPER DIAGRAM
NO SCALE
NOTE:
CEILING DIFFUSER
SHOWN. FLOOR
DIFFUSER SIMILAR.
INSULATED SUPPLY
AIR PLENUM.
24" STANDARD CABLE
OR AS REQUIRED.
ROUND
DAMPER.
TAKE-OFF AS
REQUIRED.
PLENUM
ADJUSTABLE
MOUNTING CLAMP.
DIFFUSER.
ADJUSTS WITH 1/4"
NUTDIRVER, SPECIFY
OPTIONAL SCREWDRIVER
TIP IF LESS THAN 3/8"
NON-ACCESSIBLE BRANCH DUCT DAMPER
BATHROOM WALL EXHAUST DIAGRAM
NO SCALE
BATHROOM EXHAUST
DUCTS. RE: PLANS FOR SIZE
AND QUANTITY.
BACKDRAFT DAMPER,
MOTORIZED DAMPER REQ'D FOR
300 CFM OR GREATER.
6" DEEP
INSULATED
PLENUM BOX.
SEAL AIRTIGHT.
REMOVABLE
LOUVER.
FACE OF EXTERIOR
WALL.
AS NOTED ON
PLANS.
INSULATE EXH DUCTS
24" INBOARD OF
ENVELOPE.
MIN. HEIGHT = MAX
EXH DUCT
DIAMETER + 2" BOTH
SIDES.
STUD SPACE RETURN AIR TRANSFER DUCT DIAGRAM
RETURN GRILLE, TYP.
SHEET METAL. CAULK AND
PAN STUD CAVITY WITH
STRUCTURE (NOT SHOWN).
STUDS CONTINUE TO
SEAL FOR AIRTIGHT
CONNECTION, TYP.
WALL FINISH BY ARCH.
FLOOR STRUCTURE.
RE: ARCH.
INTERNALLY LINE STUD
CAVITY WITH 1/2"
ACOUSTICAL DUCT LINER.
NO SCALE
AIR CONTROL & EXPANSION
TANK DIAGRAM
NO SCALE
HWS
AIR PURGER W/
AIR VENT.
HOSE END VALVE
FOR SYSTEM FILL.
DIAPHRAGM TYPE
EXPANSION TANK.
FROM
BOILER, ETC.
TO PUMP.
NO SCALE
ROUND DUCT
TAKE-OFF DIAGRAM
AIR FLOW
USE DUCT SEALANT OR
GASKETED FITTING ON HIGH
VELOCITY DUCT.
CONICAL SPIN-IN FITTING W/
MANUAL DAMPER, HANDLE,
& LOCK NUT.
FLEX DUCT.
WORM DRIVE S.S. CLAMP.
NOTE:
DIAGRAM FOR LOW & HIGH VELOCITY
DUCTWORK EXCEPT UPSTREAM OF
VAV BOXES. OMIT DAMPER & FLEX
DUCT UPSTREAM OF VAV BOXES.
TYPICAL HANGER DIAGRAM
NO SCALE
ANCHOR,
REFER TO
STRUCTURAL.
THREADED
ROD.
HANGER.
PIPE.
CONCRETE
STRUCTURE.
NOTE:
ALL PIPING WITH
INSULATION TO HAVE
INSULATION RUN FULL
SIZE THROUGH
HANGER WITH SHIELD
AND INSERT.
DUCT MOUNTED REGISTER
NO SCALE
AIRFLOW DIRECTION
SUPPLY
MIN 6"
RETURN
AIRFLOW DIRECTION
TURNED IN FLANGE.
O.B.D.
GRILLE.
45° ENTRY BOOT
SEAL AT
CONNECTION TO
DUCT.
HRV DUCT CONNECTIONS AND CLEARNACES DIAGRAM
NO SCALE
TOP VIEW FRONT VIEW
LEFT VIEW RIGHT VIEW
E-BOX
EA
FA
EA
FA
OA
RA
OA
RA
FIELD PROVIDED SUPPORT
FRAME, UNIT-STRUT OR
EQUIV.
PRIVDE SPRING VIB.
ISOLATORS.
ROUND HANGER
ROD, TYP.
FLEXIBLE CANVAS
CONNECTOR, TYP. 4.
PROVIDE FULL UNIT'S
WIDTH OF CLEARANCE
AT SIDE OF UNIT.
SNOWMELT CONNECTION: STAIR TO WALK DIAGRAM
NO SCALE
9" O.C. TYP. FOR ALL
LANDINGS & WALKS.
HYDRONIC SNOWMELT
TUBING.
NOTE:
REFER TO ARCH. DWG #___
FOR STAIR DIMENSIONS.
6" O.C. TYP. FOR ALL
STAIRS.
CEILING
FIRE ENTRY PIPING DIAGRAM
F
NO SCALE
D
FS
D
D
F
CLEANOUT DIAGRAMS
NO SCALE
6"
A
B
C
D
E
F
G
I
J K
H
M
N
L
FAN COIL UNIT INSTALLATION
NO SCALE
D
D
FIRE DEPT. CONNECTION.
EXTERIOR BLDG. WALL.
TO FIRE PROTECTION SYSTEMS.
TEST VALVE; PIPE TO OUTSIDE.
FLOW SWITCH TO ALARMS, SEE SPECS.
DRAIN VALVE; PIPE INDIRECT TO FLOOR DRAIN
PER NFPA 25 REQUIREMENTS, TYP.
SHUT-OFF VALVE.
DOUBLE CHECK TYPE BACKFLOW PREVENTER.
TAMPER SWITCHES ON VALVES.
FIRE SERVICE
FLANGE. FLOOR SINK
BALL DRIP
VALVE.
C.W. SERVICE
DIAGRAM SHOWN FOR REFERENCE ONLY, CONFIRM FINAL REQUIREMENTS
WITH FIRE PROTECTION DESIGN BUILD CONTRACTOR AND ENGINEER OF
RECORD.
PRV SET @
150 PSI
SLOPE DN @ 1/4"/L.F.
WASTE LINE
FINISHED GRADE
ADJUSTABLE GRADE CLEANOUT AND ACCESS ENCLOSURE WITH ANCHOR
FLANGE, HEAVY DUTY TOP, AND VANDAL PROOF FASTENERS, ZURN,
Z-1400-HD-KBRASS CLEANOUT PLUG W/COUNTER SUNK HEAD.
ADJUSTABLE CLEANOUT
AND ACCESS COVER ZURN
ZB-1400. TOP OF COVER TO
BE FLUSH W/ TOP OF FLOOR.
16" CONC. PAD TROWEL
SMOOTH & EDGE.
1/8 C.I. BEND
BALANCE OF PIPING SAME
AS CLEANOUT TO GRADE.
FLOOR LINE
1/8 C.I. BEND
C.I. WASTE LINE.
LGTH TO SUIT.
1/8 BEND IF CLEANOUT
OCCURS AT END OF LINE.
PROVIDE FOLLOWING OPTIONS AS
APPROPRIATE CARPET MARKER - FOR
CARPETED AREAS. SQUARE TOP - FOR
CERAMIC TILE OR SIMILAR SQUARE
PATTERN FLOOR.
FLASHING CLAMP - FOR ABOVE GRADE
WATER PROOFED AREAS.
SA FAN COIL UNIT
RA
FILTER W/ ACCESS
PANEL.
CONDENSATE DRAIN. PIPE
INDIRECT TO APPROVED
RECEPTOR (PROVIDE
MIN. 2" DEEP TRAP).
SHEET METAL DRAIN
PAN.
3/4" SECONDARY DRAIN TO
APPROVED RECEPTOR.
PIPE INDIRECT TO FLOOR
DRAIN ON SINK TAIL PIECE,
TYP.
ROUND HANGER ROD TYP.
WITH EXCEPTION OF FAN
COILS LOCATED IN ATTIC.
SPRING VIBRATION
ISOLATORS, TYP.
DOUBLE LOCKNUT.
NOTES:
1. RETURN AIR PLENUM FULL
SIZE OF UNIT CONNECTION.
2. THIS SUPPORT SYSTEM IS NOT
ALLOWED IN THE ATTIC.
3. LOCATE ATTIC FAN COILS ON
4" HOUSEKEEPING PAD WITH
SPRING VIBRATION
ISOLATORS.
MOTORIZED DAMPER.
MIXING BOX.
OSA
FLOOR CLEANOUT (FCO)
CLEANOUT TO GRADE (COTG)
NOT FOR CONSTRUCTION
Project number
Date
Drawn by
7/5/2015 6:41:32 PM
M500
MECHANICAL DIAGRAMS
HUGHES-1
LOT 3 / 994 PTARMIGAN RD
VAIL,CO
Hughes
Residence
06.29.15
DAL
No. Description Date
PERMIT SET