HomeMy WebLinkAboutB15-0250_M501_1442254080.pdfRADIANT MANIFOLD PIPING DIAGRAM NO SCALE A B HWR HWS NOTE: PROVIDE MANUFACTURER'S MANIFOLDS WITH VALVES EAGLE RIVER WATER ENTRANCE DIAGRAM F M NO SCALE 2-WAY COIL PIPING DIAGRAM NO SCALE C E 3-WAY COIL PIPING DIAGRAM NO SCALE D MANIFOLD BOX WITH ACCESS DOOR MOUNTED IN WALL. FIRE RATED ACCESS DOOR AS REQUIRED. MANUFACTURER'S MANIFOLD ASSY. WITH VALUES. ZONE BALANCE VALVE UNISTRUT SUPPORT SERPENTINE TUBING. QUANTITY AS REQUIRED. TAPE PIPE AT UNISTRUT SUPPORT. MANUFACTURER'S MANIFOLD ASSY. WITH VALUES. TO T-STAT. TO PIPING MAINS LOOP CONTROL VALVES, TYP. SEE FIRE ENTRY DIAGRAM , THIS SHEET. _" LINE (VERIFY WITH FIRE PROTECTION CONTRACTOR). DOMESTIC WATER SERVICE SHUT-OFF VALVE. _" IRRIGATION LINE WITH APPROVED REDUCED PRESSURE BACKFLOW PREVENTION DEVICE. (VFY. WITH IRRIGATION CONTRACTOR). 1-1/2" CW TO BUILDING. REDUCED PRESSURE TYPE BACKFLOW PREVENTER. CERTIFIED TESTER TO TEST. 1" WATER METER WITH REMOTE READOUT. PRESSURE REDUCING VALVE, TYP. WATTS 223, __" SET @ 60 PSI WATTS 223, __" SET @ __ PSI 2" CW/FIRE SERVICE (VERIFY SIZE WITH FIRE PROTECTION CONTRACTOR). NOTE: WATER METER AND BACKFLOW PREVENTER MUST BE MOUNTED HORIZONTALLY. DESIGNER NOTES: 1. VERIFY IF & WHERE BFP IS REQ'D. 2. VERIFY IF FIRE PIPING APPLIES TO JOB. 3. LOCATE REMOTE METER READOUT. 4. IF ONLY ONE PRV IS USED, OMIT a. SECOND PRV b. ISOLATION VALVES ON PRV 5. COORDINATE PIPING AND VALVING WITH AHJ. METER BYPASS. COIL NOTES: 1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAINING FANS OR COMPRESSORS, NOT REQ'D FOR EQUIPMENT SUCH AS DUCT COILS. 2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERS MOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL). 3. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION. 4. 2-WAY VALVE NORMALLY OPEN FOR HEATING AND NORMALLY CLOSED FOR COOLING. MANIFOLD PIPING DIAGRAM NO SCALE SMR SMS CONTROL VALVE. MANIFOLD BOX (WALL MOUNTED FOR RADIANT; LOCATED IN SLAB FOR SNOWMELT). MANUFACTURER'S MANIFOLD ASSY. LOOP BALANCE/ISOLATION VALVE MANUFACTURER'S MANIFOLD ASSEMBLY WITH REVERSE RETURN PIPING. RADIANT/SNOWMELT TUBING. LOOP QUANTIITY AS REQUIRED. NOTES: 1. PROVIDE MANUFACTURER'S MANIFOLDS AND ISOLATION VALVES WITH PIPING. 2. FOR EXTERIOR MANIFOLD LOCATIONS PROVIDE WATERPROOF MANIFOLD BOX OR WATERPROOF CONTROL VALVE. TO PIPING MAINS AIR VENT AT HIGH POINTS, TYPICAL. MANIFOLD BALANCE VALVE. RETURN SUPPLY COIL NOTES: 1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAINING FANS OR COMPRESSORS, NOT REQ'D FOR EQUIPMENT SUCH AS DUCT COILS. 2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERS MOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL). 3. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION. 4. 3-WAY VALVE WITH COIL RETURN PIPED TO NORMALLY OPEN PORT FOR HEATING AND NORMALLY CLOSED PORT FOR COOLING. MANUAL AIR VENT AT HIGHEST POINT IN PIPING. STRAINER WITH BLOWDOWN VALVE AND CAP. SUPPLY RETURN STRAINER WITH BLOWDOWN AND CAP. MANUAL AIR VENT AT HIGHEST POINT IN PIPING. NOT FOR CONSTRUCTION Project number Date Drawn by 7/5/2015 6:41:32 PM M501 MECHANICAL DIAGRAMS HUGHES-1 LOT 3 / 994 PTARMIGAN RD VAIL,CO Hughes Residence 06.29.15 DAL No. Description Date PERMIT SET 09/14/15