Loading...
HomeMy WebLinkAboutB15-0250_S102_1467739080.pdf236 304 310 309 305 302 2 6 3 4 5 A B C K L M 24'-4" 8'-7 1/2" 21'-3" 20'-1" 3'-7 1/2" 3'-3" 30'-1 3/4" 7'-4" 6'-3 1/4" 7 6 6 7 7 HSS9x5x3/8 HSS6x4x3/8 11 7/8" TJI560 @ 16" O.C. 11 7/8" TJI560 @ 16" O.C. 11 7/8" TJI210 @ 16" O.C. 11 7/8" TJI210 @ 16" O.C. 11 7/8" TJI210 @ 16" O.C. 11 7/8" TJI210 @ 16" O.C. @ 16" O.C. MAX 11 7/8" TJI210 11 7/8" TJI210 @ 16" O.C. 11 7/8" TJI210 @ 16" O.C. 7 1/4" LVL @ 16" O.C. FH3 - 32 H1 - 11 FH3 - 32 7 H8 - 22 H1 - 12 11 7/8" TJI560 @ 16" O.C. (2) 11 7/8 LVL (3) 11 7/8 LVL W10x49 (3) 11 7/8 LVL H7 - 42 (2) 11 7/8 LVL (2) 11 7/8 LVL (2) 11 7/8 LVL W10x26 W10x19 W10x19 11 7/8" TJI560 @ 16" O.C. (2) 11 7/8" LVL @ 16" O.C. 7 H6 - 13 W18x40 W16x31 (2) 11 7/8 LVL W10x68 W10x22 W10x49 9'-6" INTO WALL EXTEND HEADER FH2 -FH1 - 11 HSS10x5x3/8 (2) 11 7/8 LVL 1 S610 TYP 5 S610 TYP 8 S610 7 S610 1'-0" 6 S500 4 S500 ( 152' - 10 1/2" ) 7 S500 3 S500 3 S500 TYP WS3 153'-0" WS3 153'-0" 153'-0" WS3 WS1 6 S610 W10x19 FH3 - H7 - 11 (3) 11 7/8 LVL FH1 -W1-B0 W1-B1 W1-B1 W1-B0 W1-B0 W1-B7 W1-B1 W1-B2 W1-B3 H8 - 11 H1 - 11 9 HSS9x5x3/8 7 2 WS1 1 S611 2/S500 1/S500 (2) 11 7/8 LVL (2) 11 7/8 LVL 11 7/8" TJI210 @ 16" O.C. 1 SEE MARK 1 3/S602 SEE MARK 2 3/S602 SEE MARK 1 3/S602 12 S620 2 S501 TYP AT HSS GIRT 3 S620 2 S501 TYP AT HSS GIRT 1/S500 6/S602 H1 - 11 3 S620 11 S620 6 S501 10 2 2 1 1 (2) 11 7/8 LVL 2 S603 1 S611 H1 - 11 (2) 11 7/8 LVL W10x19 2/S500 1/S500 EE 7 (2) 11 7/8 LVL 3 S611 EE 4 S611 SIM S200 3 UPPER STAIR LANDING HSS6x4x5/16 HSS6x4x5/16 (2) 11 7/8 LVL (2) 11 7/8 LVL H2 - 11 7 4 4 147'-4" 4 H6 - 22 W1-B0 5 S611 3 3/8" 2 S603 TYP. (3) LOCS TYPE 7 HOLDDOWN THIS END 4 (2) 11 7/8 LVL H1 - 11 11 7/8 LVL @ 24" OC 12 S620 SIM 7 S611 TYP S611 8 S611 8 W12x19 H2-12 1/S500 EE HSS12x8x1/4 HSS12x4x3/8 ( 152'-8" ) 3'-0" HSS12x8x1/45 S603 ( 152'-8" ) 3N 6 S603 SLOPE 9 S603 7 S603 8 S603 HSS8x8x1/4 2 2 9 B/DECK = 152'-4" B/DECK = 152'-1" (152'-4") 4 S603 6 6 ( 152' - 8" ) HSS12x8x1/4 ( 152' - 8" ) 9 S603 SIM FOR HSS TO HSS CONN 153'-0" WS3 WS3 153'-0" (3) 11 7/8 LVL 6" MAX 7 S602 H4 - 11 W1-A0 7 S610 8 S610 TYP BELOW ATTIC W/ 2x4 OR 2x6 STUDS TYP TYP RFI #80 FLOOR FRAMING PLAN NOTES 1. SEE S0 SERIES SHEETS FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS. 2. SEE S5 SERIES SHEETS FOR TYPICAL STEEL DETAILS. 3. SEE S6 SERIES SHEETS FOR TYPICAL WOOD DETAILS. 4. TOP OF STRUCTURAL STEEL ELEVATION SHALL BE 152’-9 3/4" UNLESS NOTED OTHERWISE ON PLAN. 5. WOOD SHEAR WALLS ABOVE THE FLOOR NOTED THUS: SEE 6. ALL WALLS SHALL BE W1-A, UNLESS NOTED OTHERWISE. 7. WOOD HEADERS NOTED THUS: SEE 8. COLUMNS AND POSTS NOTED THUS: SEE SCHEDULE AND 9. FOR WOOD HANGER SCHEDULE, SEE: UNO 10. FOR WOOD FLOOR SCHEDULE, SEE: 5/S601 W1-A H6-22 12/S600 5 BP-1 6/S601 9/S601 8/S601 Project number Date Drawn by MM JOB #: 15.0197.S.01 PRINCIPAL/EOR: PD PROJECT MANAGER: KH DESIGNERS: JW/KH DATE PRINTED: FILE PATH: 05.27.2016 C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt 5/27/2016 12:17:53 PM S102 LEVEL 3 FLOOR PLAN M15.0197.S.01 LOT 3 / 994 PTARMIGAN RD VAIL,CO Hughes Residence 07.02.2015 KH 1/4" = 1'-0" LEVEL 3 NORTH COLUMN SCHEDULE (SEE 6/S601) MARK TYPE REMARKS 1 (2) 2x6 2 (3) 2x6 3 (4) 2x6 4 (3) 5 1/2 LVL 5 (4) 5 1/2 LVL 6 HSS3x3x1/4 SEE 12/S500 FOR BP 7 HSS4x4x1/4 SEE 12/S500 FOR BP 8 (5) 2x6 9 HSS5x5x1/4 SEE 12/S500 FOR BP 10 HSS9x5x1/4 SEE 12/S500 FOR BP 11 3 1/2x5 1/2 PSL 12 6x6 PRESERVATIVE TREATED No. Description Date PERMIT SET 07.02.2015 4 CD 10.06.2015 5 CD REV #1 10.21.2015 6 CD REV #2 05.27.2016 (3) 9-1/2" LVL, RFI #70, 3/21/16 4 holes drilled through end of LVL, BCI. OK per RFI 88, 4/27/16 HU4.12/11 face mount hanger (allows for 2x 1 3/4" LVL + 3/8" spacer) RFI 87, 5/3/16 See attached SSK-25 for LVL to HSS column shear plate connection. RFI 87 5/3/16 (2) 11-7/8 LVL RFI 87, 5/3/16 6'-5" 3-5/8" diameter hole OK per RFI 80 4/13/16 Hanger welded on 3-sides is acceptable per RFI 56 2/22/16 Hanger welded on 3-sides is acceptable per RFI 56 2/22/16 Knife Plate: 3/8"x5-3/4"x0'-9 w/ (3)-3/4" thru bolts, 5/16" fillet weld ea. side of knife plate 3/8" Knife Plate 2/ (3)-3/4" bolts. RFI 52 2/24/16 Provide single trimmer or change header to FH2 and connect per 6/S602 per RFI 50, 2/16/16 Connect per 4/S602 or 9/S601 RFI 48 2/9/16 ~7' 2-1/2" diameter hole, centered in beam SEE 3/S620 for lintel connection. RFI #73 3/29/16 07/05/16