Loading...
HomeMy WebLinkAboutB15-0250_S601_1467739080.pdfMARK HOLDOWN TYPE 6 ANCHOR RQMTS MINIMUM ATTACHMENT REMARKS HOLDOWN SCHEDULE MARK STUDS W1-A SHEATHING BLOCKED EDGES EDGE NAILING STRUCTURAL WOOD WALL SCHEDULE REMARKS 1/2" GYP BD EA FACE NO 5d @ 4" OC 7 W1-B 2x6 DF#2 @ 16"OC 1/2" APA RATED PLYWOOD YES 10d @ 6" OC WOOD WALL TYPE SEE: SCHED W1-A1 HOLDOWN TYPE SEE: SCHED STRUCTURAL WALL NOTES: 1. ALL STRUCTURAL WOOD WALLS SHALL BE W1-A, UNO. 2. PLYWOOD SHEATHING TO BE APA-RATED SHEATHING. SEE: GENERAL NOTES FOR ADDITIONAL INFORMATION. 3. PLYWOOD SHEATHING NAILS SHALL BE INSTALLED A MINIMUM OF 3/8" FROM PANEL EDGES. 4. PLYWOOD SHEATHING NAILS TO BE GALVANIZED COMMON. 5. AT PLYWOOD SHEATHING, USE 10d NAILS @ 12" OC FOR FIELD NAILING. 6. ALL PLYWOOD SHEATHING TO BE BACKED WITH 2" NOMINAL OR WIDER MEMBER. 7. PROVIDE A MINIMUM OF (2) STUDS AT EACH HOLDOWN. 8. CONNECT SHEAR PANELS DIRECTLY TO STUDS. 9. ALL WALL NAILING AT WALLS, INCLUDING HEADERS, BLOCKING, RIMBOARDS, ETC. SHALL CONFORM TO REQUIREMENTS OF NAILING SCHEDULE IN IBC 2012, TABLE 2304.9.1 UNLESS MORE STRINGENT REQUIREMENTS ARE SHOWN IN DRAWINGS. SHEAR WALL KEY HOLDOWN NOTES: 1. INSTALL ALL HOLDOWNS AND HOLDOWN ANCHORS PER MNFR's WRITTEN INSTRUCTIONS. 2. UNLESS OTHERWISE NOTED, MINIMUM HOLDOWN ATTACHMENT TO BE (2) 2x ~ MATCH WALL STUD THICKNESS. PROVIDE ADDITIONAL STUDS AS NEEDED AT HOLDOWN TO MEET MANUFACTURE REQUIREMENTS OF MINIMUM MEMBER THICKNESS ANCHORAGE TO FDN 5/8"Ø @ 48"OC HDG w/12" EMBED 5/8"Ø @ 48"OC HDG w/12" EMBED FIELD NAILING PER NOTES 2x BLKG AT SHEATHING EDGES (WHERE REQUIRED PER SCHEDULE) EDGE NAILING PER SCHEDULE EDGE NAILING SHEATHING PER SCHEDULE ~ STAGGER EDGES AS SHOWN STUD SIZE & SPACING PER SCHEDULE ANCHORAGE TO FDN CONNECTION AT SILL PLATE CONNECTION AT TOP PLATE 16d @ 3"OC 16d @ 4"OC SIMPSON LS50 @24" OC SIMPSON LS50 @24" OC 0 NO HOLD DOWN 8 SIMPSON HDU2-SDS2.5 { STUDS & SPACING W1-C YES 10d @ 4" OC 5/8"Ø @ 36"OC HDG w/12" EMBED 16d @ 2"OC SIMPSON LS50 @16" OC SIMPSON SSTB16 W1-D 10d @ 4" OC (EXT) 5d @ 4" OC (INT) 5/8"Ø @ 24"OC HDG w/12" EMBED (2) ROWS 16d @ 3"OC SIMPSON LS50 @12" OC YES 9 SIMPSON HDU4-SDS2.5 SIMPSON SB5/8x24 SIMPSON HDU5-SDS2.5 SIMPSON SB5/8x24 SIMPSON HDU8-SDS2.5 SIMPSON SSTB28 (3) LSL STUDS ANCHOR BOLTS TO BE HDG ANCHOR BOLTS TO BE HDG ANCHOR BOLTS TO BE HDG ANCHOR BOLTS TO BE HDG W1-E YES 10d @ 2" OC 5/8"Ø @ 16"OC HDG w/12" EMBED SIMPSON LS70 @12" OC W2-B YES 10d @ 6" OC 5/8"Ø @ 48"OC HDG w/12" EMBED 16d @ 3"OC SIMPSON LS50 @24" OC 1/2" APA RATED PLYWOOD 1/2" APA RATED PLYWOOD (EXTERIOR) 1/2" GYP BD (INTERIOR) 1/2" APA RATED PLYWOOD 2x6 DF#2 @ 16"OC 2x6 DF#2 @ 16"OC 2x6 DF#2 @ 16"OC 1 1/2x5 1/2 LSL @ 16"OC 1 1/2x7 1/4 LSL @ 16"OC 1/2" APA RATED PLYWOOD (2) ROWS 16d @ 2"OC 5 (2) SIMPSON MSTC 66 -- (2) LSL STUDS (2) LSL STUDS (2) LSL STUDS (2) LSL STUDS -- 4 (2) SIMPSON MSTC 52 -- (2) LSL STUDS -- 3 SIMPSON MSTC 66 -- (2) LSL STUDS -- 2 SIMPSON MSTC 52 -- (2) LSL STUDS -- 1 SIMPSON MSTC 28 -- (2) LSL STUDS -- CONN AT SILL PLATE PER 1/S610 2 HORIZONTAL DIAPHRAGM SCHEDULE MARK SHEATHING MATERIAL BLOCKED EDGES FASTENER TYPE & SPACING 5/8" THICK 20/40 APA- RATED PLYWOOD NO NO 3/4" THICK 24OC STURD-I- FLOOR APA-RATED SHEATHING YES NOTES: 1. MINIMUM EDGE DISTANCE FOR NAILS SHALL BE 3/8". 2. PROVIDE BOUNDARY NAILING (TYPE 4 ABOVE) INTO ALL SUPPORTING BEAMS, WALLS, JOIST BLOCKING, AND RIM BOARDS UNO. WS1 WS2 WS3 1 10d @ 6" OC 2 10d @ 12" OC 3 NA 4 10d @ 6" OC 1 10d @ 6" OC 2 10d @ 12" OC 3 10d @ 6" OC 4 10d @ 6" OC 1 10d @ 6" OC 2 10d @ 12" OC 3 NA 4 10d @ 6" OC 2 1 PANEL EDGE NAILING AT SUPPORTED EDGES 2 FIELD NAILING 3 PANEL EDGE NAILING AT BLOCKED EDGES 4 BOUNDARY NAILING BEAM OR WALL DIAPHRAGM EDGE TRUSSES, RAFTERS OR JOISTS 2x FLAT BLOCKING AT UNSUPPORTED SHEATHING EDGES (WHERE REQD ~ SEE SCHEDULE) 1 3 4 5/8" THICK 20/40 APA- RATED PLYWOOD NOTES: 1. VERIFY SETBACK DIMENSIONS SHOWN ABOVE WITH HOLD DOWN MANUFACTURER. 2. NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO INSTALLING ANCHORS. 3. ANCHORS SHALL BE LOCATED AT CENTER OF SILL PLATE, UNO. 4. POST CONNECTORS ARE SIMPSON SDS SCREWS, OR EQUIVALENT, UNO. 5. SEE: FOR STEEL STRAP DETAILS AND ADDNL INFO. SILL PLATE HOLD DOWN, SEE HOLD DOWN SCHEDULE SHEAR WALL POST ANCHOR BOLT MNFR STAND-OFF AS REQD BY SEE SCHED SET BACK, EMBEDMENT 1/S603 NOTES: 1. PROVIDE A MINUMUM OF (2) STUDS AT EACH BEAM SUPPORT IF NO POST IS DESIGNATED. 2. ALL MULTIPLE STUD POSTS SHALL BE NAILED TOGETHER AS SHOWN IN DIAGRAM. 3. WHERE NAILS ARE USED, EACH ADDITIONAL STUD IS NAILED TO REMAINDER OF STUD PACK SHOWN BELOW. 10d NAIL THRU EA STUD, TYP 9" TYP EA END4" TYP 1-1/2" 2-1/2" 1-1/2" CONNECTION FASTENING JOIST TO SILL OR GIRDER (3) 8d COMMON (2 1/2"x0.131") (3) 3"x0.131" NAILS LOCATION TOENAIL BRIDGING TO JOIST (3) 8d COMMON (2 1/2"x0.131") (3) 3"x0.131" NAILS TOENAIL EA END 1"x6" SUBFLOOR OR LESS TO EA JOIST (2) 8d COMMON (2 1/2"x0.131") FACE NAIL WIDER THAN 1"x6" SUBFLOOR TO EA JOIST (3) 8d COMMON (2 1/2"x0.131") FACE NAIL 2" SUBFLOOR TO JOIST OR GIRDER (2) 16d COMMON (3 1/2"x0.162") BLIND & FACE NAIL SOLE PLATE TO JOIST OR BLOCKING 16d (3 1/2"x0.135") @ 16"OC 3"x0.131" NAILS @ 8"OC TYP FACE NAIL TOP PLATE TO STUD (2) 16d COMMON (3 1/2"x0.162") (3) 3"x0.131" NAILS END NAIL STUD TO SOLE PLATE (4) 8d COMMON (2 1/2"x0.131") (4) 3"x0.131" NAILS TOE NAIL END NAIL DOUBLE STUDS 16d (3 1/2"x0.135") @ 16"OC 3"x0.131" NAILS @ 8"OC FACE NAIL (2) 16d COMMON (3 1/2x0.162") (3) 3"x0.131" NAILS BLOCKING BTWN JOISTS OR RAFTERS TO TOP PLATE TOENAIL RIM JOIST TO TOP PLATE 8d (2 1/2"x0.131") @ 6"OC 3"x0.131" NAILS @ 8"OC TOE NAIL CEILING JOISTS (TO PLATE) TOE NAIL CEILING JOISTS (LAPS OVER PARTITION) (3) 16d COMMON (3 1/2"x0.135") (4) 3"x0.131" NAILS FACE NAIL CEILING JOISTS (TO PARALLEL RAFTERS) FACE NAIL RAFTER TO PLATE FACE NAIL (3) 8d COMMON (2 1/2"x0.131") (3) 3"x0.131" NAILS (3) 8d COMMON (2 1/2"x0.131") (5) 3"x0.131" NAILS (3) 16d COMMON (3 1/2"x0.135") (4) 3"x0.131" NAILS (3) 8d COMMON (2 1/2"x0.131") (3) 3"x0.131" NAILS TYP WOOD MEMBER FASTENING SCHEDULE JACK RAFTER TO HIP TOENAIL (3) 10d COMMON (3"x0.148") (4) 3"x0.131" NAILS FACE NAIL (2) 16d COMMON (3 1/2"x0.162") (3) 3"x0.131" NAILS JOIST TO BAND JOIST FACE NAIL (3) 16d COMMON (3 1/2"x0.135") (4) 3"x0.131" NAILS NOTES: 1. TYP WOOD MEMBER FASTENING REQUIREMENTS ARE TAKEN FROM IBC 2012, TABLE 2304.9.1. 2. THE ABOVE FASTENING REQUIREMENTS ARE A MINIMUM, AND SHOULD BE APPLIED ONLY TO TYPICAL SITUATIONS. 3. THE ABOVE IS ONLY A SUMMARY OF THE TABLE 2304.9.1, PLEASE REFERENCE IBC FOR COMPLETE FASTENING SCHEDULE. JOIST/BEAM FACE MOUNT HANGER TOP FLANGE HANGER WOOD HANGER SCHEDULE NOTES: 1. ALL HANGERS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE. 2. ALL TJI'S ARE TO HAVE WEB STIFFENERS AT HANGERS UNLESS NOTED OTHERWISE 2x8 LUS26 JB28 2x10 LUS28 JB210 2x12 LUS210 JB212 11 7/8" TJI-210 (AT RIDGE) -- LBV2.1/11.88 11 7/8" TJI-360 (AT SLOPED ROOF) -- LBV2.37/11.88 11 7/8" TJI-210 ITS2.06/11.88 11 7/8" TJI-360 11 7/8" TJI-560 IUS3.56/11.88 7 1/4" LVL HU7 LBV1.81/7.25 9 1/2" LVL HU7 LBV1.81/9.5 11 7/8" LVL HUS1.81/10 LBV1.81/11.88 (2) 11 7/8" LVL HU412 BA3.56/11.88 (3) 11 7/8" LVL HU612 WP5.50/11.88 ITS2.37/11.88 ITS3.56/11.88 IUS2.37/11.88 IUS2.06/11.88 5 1/2" LVL HU1.81/5 -- 3 5/8" MAX VERTICAL LEG OF ANGLE TIGHT TO BACK OF VENEER VENEER TIES STONE VENEER LOOSE LINTEL SCHEDULE REMARKS LINTEL OPENING LENGTH, L LLV 6" LLV 6" LLV 6" 4" BEARING EE L ≤ 6'-0" L3 1/2x3 1/2x1/4 10'-0" < L ≤ 12'-0" 6'-0" < L ≤ 8'-0" 8'-0" < L ≤ 10'-0" BENT PL 5/16X8X3 1/2 L6x3 1/2x5/16 L5x3 1/2x1/4 - STRUCTURAL WALL SYSTEM 8" MAX NOTE: - STONE VENEER LOOSE LINTEL SHALL BE HDG Project number Date Drawn by MM JOB #: 15.0197.S.01 PRINCIPAL/EOR: PD PROJECT MANAGER: KH DESIGNERS: JW/KH DATE PRINTED: FILE PATH: 05.27.2016 C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt 5/27/2016 12:18:04 PM S601 TYPICAL WOOD DETAILS M15.0197.S.01 LOT 3 / 994 PTARMIGAN RD VAIL,CO Hughes Residence 07.02.2015 KH NO SCALE 5 TYP WOOD STRUCTURAL WALL & HOLDOWN SCHEDULES NO SCALE 8 TYP WOOD HORIZONTAL DIAPHRAGM SCHEDULE NO SCALE 3 TYP WOOD HOLD DOWN AT FND NO SCALE 6 TYP WOOD POST NO SCALE 11 TYP WOOD MEMBER FASTENING SCHEDULE NO SCALE 9 WOOD HANGER SCHEDULE NO SCALE 12 TYP VENEER LOOSE LINTEL No. Description Date PERMIT SET 07.02.2015 2 FND SET 09.22.2015 4 CD 10.06.2015 6 CD REV #2 05.27.2016 RFI 28 Use 1/2" wood sheathing at exterior side of walls See RFI 54 for Hold Down Alternates 07/05/16