HomeMy WebLinkAboutB15-0250_S602_1467739080.pdfJOIST HANGER PER
WEB STIFFENER EA
FACE
CONTINUOUS 1.75x11.875"
LSL LEDGER W/ (2) 5/8"Ø
EXP ANCHORS @ 32" OC
CONC WALL
9/S601
6 1/2"
3" DIAPHRAGM EDGE
NAILING
MIN 4 1/2" EMBED
SIMPSON LCE4 W/ MAX
NUMBER OF NAILS PER
MNFR, AT LVL TO PSL
BEARING CONNECTION
K
MAXIMUM UNIFORM LOAD APPLIED TO OUTSIDE BEAM (PLF)
A 470
C
B 355
-
NOTES:
1. BOLTS ARE A307-36. BOLT HOLES = SAME DIAMETER AS BOLT.
2. USE WASHERS @ HEAD & NUT.
3. USE (2) ROWS OF FASTENERS FOR BEAMS < 12" NOMINAL.
MULTIPLE
ASSEMBLY
TYPE
(3) ROWS 16d 3-1/2"
COMMON WIRE @
16" O.C.
(3) ROWS 16d 3-1/2"
COMMON WIRE @
12" O.C.
(3) ROWS 1/2"
BOLTS @ 24" O.C.
(3) ROWS 1/2"
BOLTS @ 12" O.C.
705
530
-
503
380
340
1010
760
680
ASSEMBLY A
(2) PCS. @ 1-3/4"
2" 2"
ASSEMBLY B
(3) PCS. @ 1-3/4"
2" 2"
ASSEMBLY C
(4) PCS. @ 1-3/4"
2"
2" 7" WIDE BEAMS SHOULD ONLY BE
USED WHEN LOADS ARE APPLIED
TO BOTH SIDES OF THE MEMBER
(TO MINIMIZE ROTATION).
MARK 1 2 3 4
PL 3/8 EA FACE, TYP SPACE
BTWN PLATES SHALL
EQUAL BM WIDTH +1/8"
BACK PL 3/8, TYP
BOT PL 3/8, TYP
TYP
1/4
TYP
1/4
TYP
3 3/4" 3" 1 1/4"
1 1/2" 3 1/2"
5
TRIMMER(S)
TRIMMER(S)
CONTINUE FLUSH HEADER TO
TRIMMER(S) EACH SIDE OF
OPENING
ELEVATION
PLAN
LSL RIM OR CONT
FLUSH HEADER
AT PERP JOIST,
PROVIDE JOIST
HANGER PER9/S601
FLUSH HEADER
1 1/2" 3" 3" 1 1/2"
1 1/2"1 1/2"
3 1/2"
1/2"
1/4
1/4
PL3/8 BTWN LVL'S
W/ (3) 3/4"Ø A307
THRU BOLTS
SIMPSON MSTA21 EA FACE
SIMPSON MSTA21 EA FACE
11 7/8" LVL BLOCKING ON
INSIDE FACE, 1'-0" MIN ,
(4) 3/8"x5" LAG SCREWS
2'-1 1/2" 5'-6" MAX VOTIVE
HEIGHT
2'-0" MIN SIMPSON MSTA49 AT
EACH CORNER
2x BLOCKING TO ALIGN
WITH BOTTOM OF HEADER
OF STRAP
2'-0" TO END
2x BLOCKING TO ALIGN
WITH SILL
SIMPSON MSTA49 AT
EACH CORNER
HEADER, SEE PLAN
SIMPSON TB SCREW (TB1460S)
AT 1'-0" OC TO TOP OF VOTIVE
OPENING (6 MIN)
HSS COLUMN. SEE PLAN
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01
PRINCIPAL/EOR: PD PROJECT
MANAGER: KH DESIGNERS:
JW/KH
DATE
PRINTED:
FILE PATH:
05.27.2016
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt
5/27/2016
12:18:05 PM
S602
TYPICAL WOOD DETAILS
M15.0197.S.01
LOT 3 / 994 PTARMIGAN RD
VAIL,CO
Hughes
Residence
07.02.2015
KH
NO SCALE 1 TYP WOOD JOIST AT CONC WALL
NO SCALE 2 LVL BM TO POST CONN
NO SCALE 3 MULTIPLE-MEMBER CONNECTION
NO SCALE 4 TYP WOOD BEAM AT CONT COLUMN
NO SCALE 5 FLUSH HEADER
4
1 1/2" = 1'-0" 6 KNIFE PLATE AT WOOD BM
1" = 1'-0" 7 POP OUT HANGER DETAIL
3/4" = 1'-0" 8 VOTIVE SHEAR WALL
No. Description Date
PERMIT SET 07.02.2015
2 FND SET 09.22.2015
4 CD 10.06.2015
5 CD REV #1 10.21.2015
6 CD REV #2 05.27.2016
07/05/16