HomeMy WebLinkAboutSpecial inspection North Flat Roof Header.pdfRFI No. 00059 Project No:47-15-00 Hughes Residence REQUEST FOR INFORMATION Date: Page: 3/3/2016 1 of 1 TITLE: POSSIBLE W ORK POSSIBLE SCHEDULE REQUEST FOR INFORMATION: IMPACT:IMPACT:IMPACT: POSSIBLE COST North Flat Roof Header PRIORITY:Normal Priority Attn: Heather Barrie Phone: Fax: Ryan Smith TO: KH W ebb Architects FROM: R.A. Nelson LLC PROCESS STARTED: QUESTION ENTERED: AN SWER REQUIRED: RESPONSE WRITTEN: RESPONSE ENTERED: RFI CLOSED: 3/3/2016 3/10/2016 Per the coorespondence between RA Nelson and Kevin Haas, please confirm it is acceptable to change the (4) 9 1/2 LVL at the north flat roof structure to (3) 11 7/8 LVLs and move these on top of the wall per attached sketch. PROPOSED SOLUTION: R.A. Nelson LLCRequested By:Date: Contact:Ryan Smith RFI ANSWER: Heather Barrie Signed: An swered By:KH Webb Architects Date: RFI ANSWER IMPACT: Cost Impact:Schedule Impact:No No Cost Amount:$0.00 Disclaimer:R.A. Nelson & Associates ( RANA ) will not proceed on this matter until an acceptable solution is agreed upon between RANA and the project owner addressing any and all potential schedule, budget and design impacts. R.A. Nelson LLC 51 Eagle Road #2 / P.O Drawer 5400 / Avon, Colorado / 81620 / 970.949.5152 / Fax 970.949.4379 Form: f_rfi_11mRev. Date: 09/08/06 W12x26W12x26W12x26 H1 - 1211 7/8" TJI210 @ 24" O.C. 11 7/8" TJI210 @ 24" O.C. 11 7/8" TJI210 @ 24" O.C. 7 1/4" LVL @ 24"O.C. 11 7/8" TJI210 @ 24" O.C.(2) 11 7/8 LVL(2) 11 7/8 LVLH1 - 115 1/4x9 1/4 PSL(LOW)(HIGH)WS1 WS1 H1 - 12 8S620H4 - 11 (2) 11 7/8 LVL(2) 11 7/8 LVL(2) 11 7/8 LVL(2) 11 7/8 LVLH1 - 11H1 - 11WS1 162'-1" (4) 9 1/2 LVL 6'-6" INTO WALL EXTEND HEADER 49