Loading...
HomeMy WebLinkAboutSpecial inspection test report.pdf June 15, 2016 Subject: Interim Materials Testing Summary, 994 Ptarmigan Road - Materials Testing – Special Inspections, Eagle County, Colorado Job Number: 15-6580 Mr. Jim Hughes Saloon 4937, LLC 230 40th Avenue East Seattle, WA 98112 Dear Mr. Hughes, For the period ending June 15, 2016, representatives of GROUND Engineering Consultants, Inc. were on site to provide materials testing services at times scheduled by the Contractor, Subcontractor and/or Owner. Our reports have been completed in the field as our testing and observations were performed. The Contractor and applicable Sub Contractors were notified of the testing results and/or observations prior to our departure from the project site. This summary report includes the observation reports as well as the materials test results. Please do not hesitate to contact this office if you have any questions concerning these reports. Sincerely, GROUND ENGINEERING CONSULTANTS, INC. Chris Hutto, CET Construction Services Manager 994 Ptarmigan Road - Materials Testing/Special Inspection Eagle County, Colorado Job #15-6580 GROUND Engineering Consultants, Inc. Period Ending 6/15/2016 Concrete Field Observation Reports/ Compressive Strength Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper 994 Ptarmigan Road Mr. Jim Hughes Saloon 4937, LLC 230 40th Avenue East Seattle, WA 98112 Comments or Photos: Results within Specifications? Reinforcing Steel Checked? Subgrade Tested? Number of Cylinders Cast this Date: Number of Pages Attached: Field Representative: Yes No Not Applicable As scheduled, a representative visited the project site to perform periodic concrete testing. The locations of each sample are approximate. General Contractor:General Contractor Rep. Notified:Rep Notified Job Number Concrete Cover Report Date:Date Job Number:Job Name April 28, 2016 15-6580 R A Nelson Jeff 4 1 Shane Sorensen Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper 994 Ptarmigan Road Mr. Jim Hughes Saloon 4937, LLC 230 40th Avenue East Seattle, WA 98112 Cylinders Cast on Ticket Number: Total Number of Cylinders Cast: Cylinder Diameter (in.) Cross Sectional Area (sq. in.) Maximum Load (lbs.) Compressive Strength (psi) Test Date Test Age (days) Fracture Type Average 28-Day Compressive Strength (psi): Placement Contractor: Earthwork Contractor Rep. Notified: Rep Notified Report Date: Date Job Number: Job Name General Contractor: General Contractor Rep. Notified: Rep Notified Placement Date: Job Number Placement Method: Finish Method: Item Number /Structure Type: Concrete Supplier: Mix Identification: Total Cubic Yards Placed: Weather/Temp.: (°F)(pcf) Placement Location: Specifications Specified Strength (psi): Air Content (%): Slump (in.): Temperature (°F): Concrete Field Properties Test No.Sample Location Truck Number Ticket Number Batch Time (gal.) Test Time Slump/ Spread C143 Air Content C231 Conc. Temp. C1064 Unit Weight C138 Water Added (inches) (%) Compressive Strength Results (ASTM C39) Laboratory ID: Field Technician: Comments: May 26, 2016 15-6580 April 28, 2016 R A Nelson Jeff Precision Concrete Ciro United 37610444, 3/8" exterior line mix 6 Snowing/30s Pumped Hand Exterior stairs and foundation footing Exterior stairs N of A.0/4.2-4.4, footing N of A.0/2.0-3.0 4,500 7.5 +/- 1.5 5 +/- 2 50-90 9 Bottom step N of A.0/4.3 6390 33210052 11:55 am 1:15 pm 4 3/4 3.6 70 139.3 0 9.1 Bottom step N of A.0/4.3 (Retest)6390 33210052 11:55 am 1:25 pm 5 6.0 70 137.0 0 33210052 4 5142 4.00 12.57 55,300 4,400 5/5/16 7 2 4.00 12.57 78,220 6,220 5/26/16 28 2 4.00 12.57 78,660 6,260 5/26/16 28 2 4.00 12.57 71,720 5,710 5/26/16 28 2 6,060 Shane Sorensen United QC added 5 oz. of air entrainment liquid prior to retest. Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper 994 Ptarmigan Road Mr. Jim Hughes Saloon 4937, LLC 230 40th Avenue East Seattle, WA 98112 Comments or Photos: Results within Specifications? Reinforcing Steel Checked? Subgrade Tested? Number of Cylinders Cast this Date: Number of Pages Attached: Field Representative: Yes No Not Applicable As scheduled, a representative visited the project site to perform periodic concrete testing. The locations of each sample are approximate. General Contractor:General Contractor Rep. Notified:Rep Notified Job Number Concrete Cover Report Date:Date Job Number:Job Name May 4, 2016 15-6580 R A Nelson Jeff 4 1 Dennis Humphrey Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper 994 Ptarmigan Road Mr. Jim Hughes Saloon 4937, LLC 230 40th Avenue East Seattle, WA 98112 Cylinders Cast on Ticket Number: Total Number of Cylinders Cast: Cylinder Diameter (in.) Cross Sectional Area (sq. in.) Maximum Load (lbs.) Compressive Strength (psi) Test Date Test Age (days) Fracture Type Average 28-Day Compressive Strength (psi): Placement Contractor: Earthwork Contractor Rep. Notified: Rep Notified Report Date: Date Job Number: Job Name General Contractor: General Contractor Rep. Notified: Rep Notified Placement Date: Job Number Placement Method: Finish Method: Item Number /Structure Type: Concrete Supplier: Mix Identification: Total Cubic Yards Placed: Weather/Temp.: (°F)(pcf) Placement Location: Specifications Specified Strength (psi): Air Content (%): Slump (in.): Temperature (°F): Concrete Field Properties Test No.Sample Location Truck Number Ticket Number Batch Time (gal.) Test Time Slump/ Spread C143 Air Content C231 Conc. Temp. C1064 Unit Weight C138 Water Added (inches) (%) Compressive Strength Results (ASTM C39) Laboratory ID: Field Technician: Comments: June 1, 2016 15-6580 May 4, 2016 R A Nelson Jeff Precision Concrete Ciro United 37610444 6 Sunny 60's Line pump Hand Foundation wall and small isolated footer wall 5-8' W of grid line A.0/2.0-3.0 and footer wall at A.0/5.5 4,500 7.5 +/- 1.5 5 +/- 2 50-90 10 A.0/5.5 6390 33210065 8:45 10:00 NA 4.5 70 138.4 0 10.1 A.0/5.5 (Retest)6390 33210065 8:45 10:10 6 1/2 7.6 70 134.3 0 33210065 4 5158 4.00 12.57 46,700 3,720 5/11/16 7 2 4.00 12.57 69,260 5,510 6/1/16 28 2 4.00 12.57 70,850 5,640 6/1/16 28 2 4.00 12.57 67,380 5,360 6/1/16 28 2 5,500 Dennis Humphrey United added 8 oz air entrainment added prior to retest. 994 Ptarmigan Road - Materials Testing/Special Inspection Eagle County, Colorado Job #15-6580 GROUND Engineering Consultants, Inc. Period Ending 6/15/2016 Structural Steel Field Observation Report & Discrepancy List Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper 994 Ptarmigan Road Mr. Jim Hughes Saloon 4937, LLC 230 40th Avenue East Seattle, WA 98112 Date: Location: Job Number: Yes No Outstanding Discrepancies Reported this Date? No. of Pages Attached: Field Representative: Structural Steel Cover Report As scheduled, a representative arrived to perform special inspection services. The following is a summary of services provided on this date. May 12, 2016 Site 15-6580 As directed by Jeff with R.A. Nelson, GROUND inspected the following: 1) Inspected welded connections of shear clip to column 6B in regards to SSK-25. This connection is found in compliance with SSK-25 and in general compliance with AWS D1.1-10 clause 6 table 6.1. Jeff was informed of this inspection and E-mailed a copy of this report with the current discrepancy list. 0 Josh Bash Client: www.groundeng.com Englewood, Commerce City, Loveland, Granby, Gypsum, Grand Junction, Casper 994 Ptarmigan Road Mr. Jim Hughes Saloon 4937, LLC 230 40th Avenue East Seattle, WA 98112 DateField/Fab. Shop? Fabrication Shop: Job Name:Job Name Job Number:Job Number General Contractor:Rep Notified Outstanding Structural Steel Discrepancy Log Date Reported Item Number CWI initials Description of Discrepancy Date Resolved Per Plan / Per RFI It is the responsibility of the contractor to schedule our office to perform retesting once the necessary corrective action has been made or provide our office with documentation that resolves the discrepancy. 3 remaining, Marked with orange spray paint on column or wall 3/24/16 Locations marked with orange spray paint on column or wall, 3/24/16 Locations marked with orange spray paint on column or wall, 3/24/16 Locations marked with orange spray paint on column or wall, 3/24/16 Field 994 Ptarmigan Road 15-6580 R.A. Nelson 1/26/16 1 JB GROUND is requesting Welding Procedure Specification (WPS), Welder Qualification Test Record (WQTR) and continuity logs for Ryan Hobart in accordance with AWS D1.1.1/28/16 Per plan 1/26/16 2 JB angle clip to embed for the 2nd level framing on grid A/2.5 is not fully on the embed which is not compliance with plans. 2/18/16 Per RFI #40 1/26/16 3 JB The Welded moment connection for the 2nd level grid C.2/2 is not completed per detail 3/S501 and at the time of inspection the wood has been installed.3/24/16 Per SSK-11 1/26/16 4 JB The bolted connections are found with slotted holes and the slots have not been fully covered per Research Council of Structural Connections (RCSC) for the 2nd level.4/14/16 Per Plan 1/26/16 5 JB Bolted connection to welded angle clip at grid A/2.5 2nd level is called on plans as a Pre-tension (PT) bolt per detail 8/S500. The bolts have not been tightened per RCSC for a PT connection.2/23/16 SSK-12 1/26/16 6 JB Beam to beam splice connection on grid C.7/2.5 2nd level has only a plate installed and not the double angles per detail 6/S500. This is not per project plans 2/23/16 SSK-13 3/3/16 7 CW Levels 3 and roof had various locations with exposed slots in bolted connections 4/14/16 Per Plan 3/3/16 8 CW Bolts did not achieve full projection through the nut on level 3 at grids H/2.5 and roof at grids B/5.5 4/14/16 Per Plan 3/3/16 9 CW Missing bolts in roof framing at gridlines M/5.5, G/4, G/5, C/2.5 and H2.5 4/14/16 Per Plan