HomeMy WebLinkAboutB15-0252_E2.2_1454533620.pdfROOF BELOW GOLF PATIO BELOW EVENT PATIO RAMP BELOW DS DS DS DS ROOFTOP MECHANICAL EQUIPMENT SCUPPER AND DS SCUPPER AND DS DS DS DS DS DS DS 42" HIGH GUARD 2'-11" 2'-43 4" 42" HIGH GUARD DW HOOD EXHAUST MUST TERMINATE 3' ABOVE MAU-2 INTAKE MAU 1 MAU 2 CU 5 CU 4 CU 3 EF 2 EF 1 CU 1 CU 2 1 6 X2 X1 9 8 7 6 5 4 3 2 F 2 F 3 M M MUA 1 MUA 2 M M EF 1 M EF 2 M CU 1 CU 2 M M CU 3 M CU 4 M CU 6 M J J J J J HEAT TRACE-29,31 HEAT TRACE-5,7 HEAT MATS J HEAT TRACE-9,11 J J J HEAT TRACE-17,19 PARTIAL J HEAT TRACE-13,15 UNHEATED LEAD J HEAT TRACE-2,4 J HEAT TRACE-21,23 J HEAT TRACE-1,3 PARTIAL SHEET DETAIL NOTES: PROVIDE HEAT TRACE JUNCTION BOX AT ROOF, CONNECT TO HEAT TRACE PANEL IN LOWER LEVEL MECHANICAL ROOM. COORDINATE LOCATION OF ALL HEAT TRACE JUNCTION BOXES IN FIELD, RELOCATE IF NECESSARY. PROVIDE HEAT TRACE CABLE IN ALL DOWNSPOUTS UNTIL CONDITIONED SPACE OR DAYLIGHT IS REACHED. PROVIDE IN-SLAB HEAT CABLING FOR ROOF EQUIPMENT CLEARANCE AREAS AS SHOWN ON PLANS, COORDINATE LOCATION WITH MECHANICAL PLANS. PROVIDE ALL RAYCHEM ELECTROMELT, OR EQUIVALENT, COORDINATE INSTALLATION WITH MANUFACTURER TO PROVIDE SYSTEM THAT SATISFIES REQUIREMENTS OF OWNER. 1 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 SHEET GENERAL NOTES: 1. PROVIDE HEAT TRACE CABLE FOR ALL ROOF EAVES OR VALLEYS ON NORTH SIDE OF BUILDING. COORDINATE LOCATION IN FIELD, PROVIDE ON SOUTH SIDE OF ROOF IF NECESSARY. 2 1 3 1 J 2 1 UNHEATED LEAD MECH2-7,9,11 MECH2-13,15,17 CU 5 M 3 EF 3 M MECH2- 25,27,29 MECH2- 31,33,35 MECH2- 37,39,41 MECH1-31,33,35 MECH1-37,39,41 MECH1-1,3,5 MECH1 -7,9,11 MECH1- 13,15,17 MECH1- 19,21 MECH1- 27,29 MECH1 -23,25 PARTIAL 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 J HEAT TRACE-1,3 PARTIAL 1 3 3 3 2 HEAT TRACE-17,19 PARTIAL J 1 M GRILLE2- 17,19,21 WALK-IN COND UNIT HEAT TRACE-34,36 PARTIAL J HEAT MATS J HEAT MATS J HEAT MATS J HEAT TRACE-25,27 1 HEAT TRACE-6,8 PARTIAL HEAT TRACE-33,35 HEAT TRACE-37,39 HEAT TRACE-10,12 HEAT TRACE-14,16 HEAT TRACE-34,36 PARTIAL HEAT TRACE-38,40 PARTIAL HEAT TRACE-38,40 PARTIAL 2 WATER PROOF ENCLOSURE 2 DATA FOR CAMERA 2 THORGUARD LIGHTNING EQIUPMENT UPPER2-42 Copyright © 2015 by Zehren & Associates Inc. e 6GNGRJQPG ÄÄ (CZ ÄÄ #TEJKVGEVWTCN 'PIKPGGTKPI %QPUWNVCPVU /GEJCPKECN 'NGEVTKECN  .KIJVKPI &GUKIP 5GTXKEGU /CKNKPI CFFTGUU 21 $QZ  #XQP %1  ac YYYCGEÄXCKNEQO # .''& #EETGFKVGF 2TQHGUUKQPCN 1HHKEG6/  75 *Y[    5VG  #XQP %1  NORTH ROOF POWER & SYSTEMS PLAN SCALE: 3/16" = 1'0" 02/03/16