VERIFY EXACT LOCATION OF
WALK-IN COOLER COMPRESSOR
w/MECHANICAL/ARCHITECTURAL
DRAWINGS
E.C. TO INTERWIRE FIRE PROTECTION
SYSTEM TO SHUNT TRIP BREAKERS
IN MAIN PANEL BOX & FIRE
CONTROL CENTER, (IF REQUIRED
BY CODE).
E
53
E
54
E
115.1
E
107
E
113
E
109
2
No. Item Volts
E L E C T R I C A L S C H E D U L E
0 Amp
HP
KW
RIP
LOC.
AFF
CONN.
TYPE REMARKS
SPO
E4 120-208 REACH-IN FREEZER - NEMA 14-20P
12.6
1
1.0 48"
6,8
WALL
DR
E18 120 CONVENIENCE OUTLET (2) RIP'S
8.0
1 50"
8
WALL
JB
E23 120 ICE CUBER
13.8
1 72"
1
WALL
DR
E37 120 HEATED CABINET - NEMA 5-20P - (2) RIP'S
16.0 1
1.9
72"
6
WALL
DR
E41 120 DOUBLE CONVECTION OVEN
8.0
1
0.50 18"
6
WALL
JB
E54 120
DISH WASHER - VFY. REQUIREMENTS w/OWNER
16.0
1
66"
1
WALL
DR
E63 120 CONVENIENCE OUTLET
8.0
1
50"
8
WALL
DR
E64 120
REACH-IN REFRIGERATOR - NEMA 5-15P
6.5
1
0.33 80"
6
WALL
SPO
66 208
CONVEYOR TOASTER - FUTURE EQUIPMENT - E.C. TO EXTEND, INSTALL & MAKE
10.7 1
2.23 -6,8 FROM
JB
E67 120/208 CHEF COUNTER - E.C. TO EXTEND, INSTALL & MAKEVFY. 1 VFY.
VFY. 30"
1
WALL
DR
68 120 MICROWAVE OVEN - E.C. TO EXTEND, INSTALL & MAKE FINAL16.8 1
1.2 -6,8 FROM
JB
70 120/208 HEAT LAMP - E.C. TO EXTEND & MAKE FINAL CONNECTION1 2.44 -1,5
JB
E71 120/208 TWO TIER PASS SHELF - E.C. TO EXTEND, INSTALL & MAKE FINAL CONNECTION TO ITEMS: 68 & 70
VFY. 1 VFY. 54"
1
WALL
JB
73 208
DROP-IN HOT WELL - E.C. TO EXTEND & MAKE11.9 1
2.48 -1
DR
E77 120
EQUIPMENT STAND - NEMA 5-15P
5.7 1
0.20 18"
6
WALL
DR
79 120
REACH-IN U/C FREEZER - NEMA 5-15P - E.C. TO EXTEND, INSTALL &
5.8 1
0.33 -6,8
DR
83 120 6.3
1 0.20 -6,8
DR
E84 120
FRYER DUMP STATION - NEMA 5-15P
6.3 1
0.75 18"
6
WALL
DR
E88 120 HEATED CABINET - NEMA 5-20P - (2) RIP'S
16.0
1 1.9
72"
6
WALL
JB
E91A 120/208 EXPO TABLE - E.C. TO EXTEND & MAKE FINAL CONNECTION TO (3) ITEM: 92
VFY. 3 VFY. 30"
1
WALL
JB
92 208
DROP-IN HOT WELL - E.C. TO EXTEND & MAKE FINAL CONNECTION FROM ITEM: 91A
3 -1 FROM
DR
E93 120
CARVING STATION - NEMA 5-15P
4.2
1 0.5 30"
6
WALL
DR
E96 120 CONVENIENCE OUTLET
8.0
1 50"
8
WALL
JB
102 120 (2) HEAT LAMP - E.C. TO EXTEND & MAKE FINAL CONNECTION FROM ITEM: 91B
1 2.44
-1,5 E91B
DR
E3B 120 CONVENIENCE OUTLET
8.0
1
8
WALL
DR
E3A 120 OFFICE COMPUTER - VFY. REQUIREMENTS w/OWNER
1
18"
6
WALL
DATA
"
DATA PORT - VFY. REQUIREMENTS w/OWNER
8
WALL
24"
15.0
JB
E12 120 WALK-IN COOLER EVAP. COIL - VFY. REQUIREMENTS w/SHOP DRAWINGS
1.8
1
FA
1
CLG
JB
E8 120 15.0
1
FA
1,5 CLG
& OTHER DISCONNECTS AS NEEDED.
WALK-IN COOLER - E.C. TO INTERWIRE SWITCH, LIGHTS, PRESSURE RELIEF VALVE,
CKT.
JB
E13 208-230 REFRIGERATION RACK CONDENSING UNIT - VFY. REQUIREMENTS w/SHOP DRAWINGS
3 STUB
1
ROOF
JB
E33 120 WALK-IN COOLER EVAP. COIL - VFY. REQUIREMENTS w/SHOP DRAWINGS
2.32
1
FA
1
CLG
JB
E32 120 15.0
1
FA
1,5 CLG
& OTHER DISCONNECTS AS NEEDED.
WALK-IN COOLER - E.C. TO INTERWIRE SWITCH, LIGHTS, PRESSURE RELIEF VALVE,
-E34 -DELETED
- ---
EA. EA.
EA. EA. 36"
JB
E43A 120 EXHAUST HOOD - E.C. INTERWIRE LIGHTS & FANS TO SWITCH (MOUNT SWITCH TO HOOD FACE)
15.0
1
FA
1,5
CLG
JB
E43B 120 FIRE SUPPRESSION SYSTEM
1
FA
1
CLG
15.0
CKT.
JB
E53 120
CONDENSATE HOOD - E.C. INTERWIRE SWITCH TO LIGHTS & FAN
20.0
1
FA.
1,5 CLG.
VFY. REQUIREMENTS w/SHOP DRAWINGS
E67
FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER & CAP FOR FUTURE USE
E71
CONNECTION TO J-BOX IN ITEM: 71 TWO TIER PASS SHELF
FROM
E71
FROM
E67
TO J-BOX IN ITEM: 71 TWO TIER PASS SHELF
FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF'S COUNTER
FROM
E67
MAKE FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER
FROM
E67
REACH-IN U/C REFRIGERATOR - NEMA 5-15P - E.C. TO EXTEND, INSTALL &
MAKE FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER
JB
E85 120
EXHAUST HOOD - E.C. INTERWIRE LIGHTS & FANS TO SWITCH (MOUNT SWITCH TO HOOD FACE)
15.0 1
FA
1,5
CLG
JB
E87 120 FIRE SUPPRESSION SYSTEM
1 96"
1
WALL
15.0
CKT.
DR
65 120 REFRIGERATED SANDWICH UNIT - NEMA 5-15P - E.C. TO EXTEND, INSTALL
7.3
1
-6,8
FROM
E67
& MAKE FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER
0.20
FINAL CONNECTIONS TO ITEMS: 65, 66, 73, 79 & 83
EA. EA.
E91A
DR
E103 120 CONVENIENCE OUTLET (2) RIP'S
8.0
1 50"
8
WALL
EA.
FROM
JB
E91B 120
TWO-TIER OVER SHELF - E.C. TO EXTEND & MAKE FINAL CONNECTION TO (2) ITEM: 102
VFY. 1 VFY. 69"
1,5
WALL
JB
E105.1
120 1
1,5
JB
E107
120 GLASS WASHER - VFY. REQUIREMENTS w/OWNER
16.0 1
1
E109
DR E113
120
10.0
1
DR E118
120
REFRIGERATED BACK BAR CABINET - NEMA 5-15P
5.5 1
0.25 12" 6
WALL
DR E119
120
MUG CHILLER
5.0 1
0.20 12" 6
WALL
EA.
JB 120
BLENDER STATION - E.C. TO WIRE FROM J-BOX TO OUTLET MOUNTED ON BLENDER STATION
15.0 1
1
6 BEV. GUN/CARBONATOR - VFY. REQUIREMENTS w/VENDOR
SPO
E126 208
COFFEE/TEA BREWER - VFY. REQUIREMENTS w/VENDOR
13.0 1
2.65 50" 6,8
WALL
JB E137
208
ICE CUBER
10.2 1 72" 1
WALL
DR
E121 120
P.O.S. UNIT - VFY. REQUIREMENTS w/OWNER
1
6
DATA
"
DATA PORT - VFY. REQUIREMENTS w/OWNER
8
15.0
50" WALL
50" WALL
CKT.
DR E128
120
SODA/ICE DISPENSER - VFY. REQUIREMENTS w/VENDOR
10.0 1
12" 6
WALL
JB E132
120
WALK-IN BEER COOLER EVAP. COIL - VFY. REQUIREMENTS w/SHOP DRAWINGS
1.16 1
FA 1
CLG
JB E131
120
15.0 1
FA 1,5 CLG
VALVE & OTHER DISCONNECTS AS NEEDED.
WALK-IN BEER COOLER - E.C. TO INTERWIRE SWITCH, LIGHTS, PRESSURE RELIEF
- E133
-DELETED
- - --
EA.
DR
E24 120 SODA SYSTEM - VFY. REQUIREMENTS w/VENDOR
1
78"
6
WALL
20.0
CKT.
UP 4"
10.1 3.61
38"
-
-
31.8
2
15.0 37" WALL BAR PLUG MOULD - E.C. TO SUPPLY & INSTALL ALONG UNDERSIDE OF BAR TOP
2
2
12" WALL
12" WALL
2
12" WALL
J
J
V
S
J
J
J
J
J J
S
V
J
J J
S
E
4
E
3A
E
3B
E
12
E
8
E
18
E
23
E
32
E
33
E
37
E
37
E
41
E
43A
E.C. TO INTERWIRE FIRE PROTECTION
SYSTEM TO SHUNT TRIP BREAKERS
IN MAIN PANEL BOX & FIRE
CONTROL CENTER, (IF REQUIRED
BY CODE).
E
43B
E
24
FS3
Electrical Rough-in
Plan & Schedule
ELECTRICAL ROUGH-IN PLAN (MAIN LEVEL GRILL/CATERING KITCHEN)
SCALE: 1/4" = 1'-0"
5) REQUIRES INTERWIRING BETWEEN CONTROLS AND EQUIPMENT.
4) DIRECT SERVICE TO CIRCUIT BREAKER PANEL INCLUDED WITH EQUIPMENT.
8) OUTLET FURNISHED & INSTALLED BY ELECTRICAL CONTRACTOR.
9) OUTLET FURNISHED WITH EQUIPMENT & INSTALLED BY ELECTRICAL CONTRACTOR.
7) CORD & PLUG FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR.
12) FLEX OUT OF WALL @ ROUGH-IN POINT (NO J-BOX REQ'D)
11) FINAL CONNECTION BY ELECTRICAL CONTRACTOR TO PRE-WIRED JUNCTION
10) EQUIPMENT INSTALLED IN COUNTER & WIRED BY MANUFACTURER.
BOX OUTLET IN COUNTER
1) DIRECT TO JUNCTION BOX ON EQUIPMENT.
3) DIRECT TO JUNCTION BOX THROUGH DISCONNECT.
2) DIRECT TO OUTLETS INCLUDED WITH DISCONNECT.
6) CORD & PLUG FURNISHED WITH EQUIPMENT.
CONNECTION TYPES
PHASE
SWITCH
SYMBOLS & ABBREVIATIONS
DUPLEX RECEPTACLE
SPECIAL PURPOSE OUTLET
FLOOR OUTLET
ROUGH-IN POINT
JUNCTION BOX
AMP
KILOWATT
FLEX
ABOVE FINISHED FLOOR
HORSE POWER
P.O.S. POWER/DATA PORT
FO
HP
AFF
KW
AMP
FLEX
DR/DATA
PH
SW
RIP
SPO
DR
JB
FROM ABOVE
FA
CEILING
CLG
STUB UP 4" TO JUNCTION BOX
STUB
UP 4"
STUB UP 4" TO FLOOR MOUNTED OUTLET
STUB
UP 4"
STUB UP 4" TO FLOOR MOUNTED SPECIAL PURPOSE OUTLET
STUB
UP 4"
JUNCTION BOX MOUNTED IN EQUIPMENT
JB
DUPLEX RECEPTACLE MOUNTED IN/ON EQUIPMENT
DR
DROP CORD - PROVIDED & INSTALLED BY E.C.
JB
ELECTRICAL CONTRACTOR
E.C.
ELECTRICAL NOTES:
1. ALL ROUGH-INS SHOWN RELATE TO FOOD SERVICE
EQUIPMENT ONLY. SEE ARCHITECTURAL/ENGINEERING
PLANS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.
2. FINAL CONNECTIONS TO ALL EQUIPMENT BY ELECTRICAL
CONTRACTOR, INCLUDING MATERIALS.
3. ALL LOADS INDICATED ARE ACTUAL AND NOT CIRCUIT
BREAKER SIZE UNLESS OTHERWISE NOTED.
4. ALL CONVENIENCE OUTLETS TO BE SET HORIZONTALLY.
5. ALL ROUGH-IN HEIGHTS INDICATED FROM FLOOR TO THE
CENTER LINE OF THE OUTLET. FLOOR ROUGH-INS TO BE
STUBBED UP 4" ABOVE FINISHED FLOOR OR CURB. ALL
FLOOR OPENINGS ARE TO BE SEALED WATERTIGHT.
6. ELECTRICAL CONTRACTOR TO PROVIDE SHUNT TRIP
BREAKERS FOR EQUIPMENT UNDER HOOD AND INTERWIRE
TO FIRE PROTECTION SYSTEM, PER LOCAL CODE.
7. FINAL CONNECTIONS TO EQUIPMENT JUNCTION BOX OR
PULL-BOX AND ALL ELECTRICAL WORK FROM PANEL
BOARDS, TO BE BY THE ELECTRICAL CONTRACTOR.
8. VERIFY ALL ELECTRICAL ROUGH-INS AND LOCATIONS
WITH OWNER, VENDOR OR G.C. ON EXISTING EQUIPMENT
OR OTHER EQUIPMENT NOT PROVIDED BY W.WEST.
9. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL THE
FOLLOWING AS PER CODE.
a. ALL JUNCTION BOXES, ELECTRICAL OUTLETS, COVER
PLATES, SWITCHES, ECT., NOT BUILT INTO FIXTURES
OR EQUIPMENT. ALL OUTLETS, JUNCTION BOXES,
COVER PLATES, ETC., IN LAUNDRY AREAS, DISHROOM OR
AS INDICATED ON SCHEDULES, MUST BE VAPOR PROOF,
OR AS PER LOCAL CODE.
b. ALL PLUGS & CORDS AS NOTED ON SCHEDULE. ALL
CORDS SHALL BE N.E.M.A. RATED AND U.L. APPROVED
FOR MANUFACTURED AND/OR FABRICATED EQUIPMENT.
c. SHUNT-TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR
FIRE CONTROL SYSTEM SHUT-OFF OF FOOD SERVICE
EQUIPMENT BELOW HOODS/VENTILATORS AS REQUIRED
BY N.F.P.A. 96 CODE OR LOCAL CODE.
d. DISCONNECTS OR OTHER DEVICES AS REQUIRED BY
CODES.
e. ALL REQUIRED BULBS FOR FIXTURES.
f. PLUG MOLDS SUPPLIED & INSTALLED WHERE
INDICATED.
10. WHEN APPLICABLE, ELECTRICAL CONTRACTOR TO PROVIDE
CONDUIT WIRING, INSTALL ELECTRICAL COMPONENTS AND
INTERWIRE BETWEEN THE FOLLOWING:
a. REMOTE REFRIGERATION EQUIPMENT TO EVAPORATOR
COILS AND FOR DEFROST CONTROLS.
b. CONTROL PANELS TO VENTILATORS AND EXHAUST/
SUPPLY FANS PER MANUFACTURER'S INSTRUCTIONS.
c. KITCHEN EXHAUST HOOD/VENTILATORS TO FIRE
CONTROL SYSTEM AND HOOD CONTROLS.
d. MODULE COUNTERS AND COMPONENTS OR EQUIPMENT
MOUNTED ON COUNTERS.
GENERAL WALK-IN NOTES:
1. E.C. TO VERIFY EXACT SIZE & LOCATION OF COMPRESSORS FOR
WALK-IN BOXES W/MECHANICAL CONTRACTOR.
2. E.C. TO MOUNT & INTERWIRE VAPOR-PROOF OR FLUORESCENT
LIGHTS, WHICHEVER PROVIDED, PER SPEC.. RUN CONDUIT ON
EXTERIOR TOP OF WALK-IN BOXES. LIGHTS FOR WALK-INS PER
SPEC.
3. E.C. TO SUPPLY & MOUNT SERVICE DISCONNECTS @ ALL WALK-IN
CONNECTIONS.
Scale:As Noted
Sheet Number:
Drawn By
GENERAL NOTE
These plans are the property of
W.West and use of these plans without
the written consent of W.West is
prohibited. No Responsibility is
assumed by W.West for deviations
from these drawings.
Sheet Name:
Food Service Design/Planning
Designer/Project Manager
9355 Northfield Blvd.
Denver, CO 80238
Phone: 303.289.9378
Fax: 303.289.9505
Revisions:
1
2
3
4
5
Project Number:
Tim Trujillo
Vail Golf
Clubhouse
Vail,
Colorado
T15007
J.V. J.V.
07-16-15 Permit Set
Equipment & Furnishings Co.
Checked By
Date:
08-18-15 Permit Update
Revision #2
ELECTRICAL ROUGH-IN PLAN (LOWER LEVEL SUPPORT KITCHEN)