Loading...
HomeMy WebLinkAboutB15-0252_M1.1_1465936980.pdfPOWER EF-1 SEE KITCHEN CONTACTOR SELECTION LOWER LEVEL KITCHEN HOOD SEE FLOOR PLAN UTILITY SET 2,058 - - REFER TO KITCHEN CONTRACTOR SELECTION, SHOWN HERE FOR REFERENCE EF-2 SEE KITCHEN CONTACTOR SELECTION MAIN LEVEL KITCHEN HOOD SEE FLOOR PLAN UTILITY SET 3,442 - - REFER TO KITCHEN CONTRACTOR SELECTION, SHOWN HERE FOR REFERENCE EF-3 SEE KITCHEN CONTACTOR SELECTION DISH WASHER HOOD SEE FLOOR PLAN UTILITY SET 600 - - REFER TO KITCHEN CONTRACTOR SELECTION, SHOWN HERE FOR REFERENCE EF-4 COOK 30XMW CART BARN SEE FLOOR PLAN BELT DRIVE 4,800 737.0 0.25 3/4HP 17.5 260 INSTALL HORIZONTALLY INSIDE THE DUCTWORK EF-5 PANASONIC FV-05VQ5 RESTROOM SEE FLOOR PLAN CEILING 75 731 0.10 11 W 0.3 18 PROVIDE FIELD INSTALLED BACKDRAFT DAMPER AS ADD-ALTERNATE IN ADDITION TO INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH WALL SWITCH EF-6 PANASONIC FV-30VQ3 RESTROOM / MECH ROOM SEE FLOOR PLAN CEILING 260 1,269 0.25 107W N/A 20 PROVIDE FIELD INSTALLED BACKDRAFT DAMPER AS ADD-ALTERNATE IN ADDITION TO INTEGRAL BACKDRAFT DAMPER. EF-7 COOK GC-180 CART BARN SEE FLOOR PLAN CEILING 250 877 0.25 62 W 4.0 16 PROVIDE FIELD INSTALLED BACKDRAFT DAMPER IN ADDITION TO INTEGRAL BACKDRAFT DAMPER. EF-8 COOK 10S15D ELEVATOR SHAFT HEAT RELIEF SEE FLOOR PLAN CEILING 560 994 0.00 0.017W 2.7 42 MOTOR TO BE ORDERED DOWNSTREAM AIR FLOW TO BE LOCATED OUTSIDE HOISTWAY. 115 / 1 / 60 208/ 3 / 60 208/ 3 / 60 208/ 3 / 60 120 / 1 / 60 TOTAL CFM 208/ 3 / 60 FAN RPM ESP (IN) ELECTRICAL DATA V / PH / Hz REFER TO KITCHEN CONTRACTOR NOISE LEVEL (SONES) OPER. WT. (LBS) TYPE EXHAUST FAN SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO. REMARKS SERVICE LOCATION 115 / 1 / 60 120 / 1 / 60 REFER TO KITCHEN CONTRACTOR REFER TO KITCHEN CONTRACTOR ELECTRICAL DATA IN OUT MIN MAX V / PH / Hz L(IN) H(IN) W(IN) B-1 LOCHINVAR FTXL850 SNOWMELT DHW, HRV-1 MECHANICAL ROOM 850.0 764.6 4 14 808 41.0 3.3 50 100 140 120/1/60 4 / 6 604 33 53.5 26.25 1,3,4,5,6,8, ASME B-2 LOCHINVAR FTXL850 SNOWMELT DHW, HRV-1 MECHANICAL ROOM 850.0 764.6 4 14 808 41.0 3.3 50 100 140 120/1/60 4 / 6 604 33 53.5 26.25 1,3,4,5,6,8, ASME BOILER SCHEDULE OR EQUIVALENT MANUFACTURER & MODEL NO. STACK DIA. (IN) OPER. WT. (LBS) REMARKS SERVICE DIMENSIONS RELIEF PRESS (PSI) EWT (°F) UNIT TAG 1 - OUTDOOR RESET, 2 - 50% P.G., 3 - 30% P.G., 4 - FLOW SWITCH, 5 - LOW LIMIT CUTOUT, 6 - E.P.O. SWITCH, 7 - POLYPROPYLENE VENT PIPING, 8 - CPVC VENT PIPING, 9 - PVC VENT PIPING LWT (°F) LOCATION CAPACITY (MBH) @ 8000' ASL GAS PRESSURE (IN WC) MAX PD (FT) FLOW (GPM) GAS VALUE (BTU/CF) IN (°F) OUT (°F) IN (°F) OUT (°F) DIA(IN) H(IN) WH-1 TRIANGLE TUBE SMART 120 KITCHEN COMMMON MECHANICAL 120 533 35.0 4.0 180 150 40 140 360 32 72 1312 - WH-2 TRIANGLE TUBE SMART 120 KITCHEN COMMMON MECHANICAL 120 533 35.0 4.0 180 150 40 140 360 32 72 1312 - WH-3 TRIANGLE TUBE SMART 120 KITCHEN COMMMON MECHANICAL 120 533 35.0 4.0 180 150 40 140 360 32 72 1312 - HOT WATER GENERATOR SCHEDULE OR EQUIVALENT DIMENSIONS SERVICE LOCATION STORAGE CAPACITY (GAL.) GPH @ 100°F ∆T (S.L.) OPER. WT. (LBS) REMARKS BOILER OUTPUT (MBH) UNIT TAG DOM. WATER TEMP. MANUFACTURER & MODEL NO. BOILER WATER TEMP. GPM PRESS. DROP (FT) (MBH) EAT LAT EWT LWT GPM HD (FT) HC-1 DAIKIN McQUAY 5BS0602B ERV-1 SEE FLOOR PLAN DUCT MOUNTED HORIZONTAL 1005 18X10 670 2 0.17 26.7 38.5 71.4 140 118.9 2.7 8.2 16 INTERLOCK WITH DISCHARGE AIR SENSOR REMARKS UNIT TAG MANUFACTURER & MODEL NO. TYPE AIRFLOW THROUGH COIL (CFM) AIR P.D. (IN. WC) HEATING COIL DATA COIL DIMENSIONS (H X L) OPER. WEIGHT (LBS) FACE VELOCITY (FPM) HEATING COIL SCHEDULE OR EQUIVALENT SERVICE LOCATION ROWS SENSIBLE TOTAL EDB (°F) EWB (°F) LDB (°F) LWB (°F) SUPER HEAT COIL ROWS EDB (°F) LDB (°F) EWT (°F) LWT (°F) GPM PD (FT) L(IN) H(IN) W(IN) AH-1 CARRIER - 39LC18KA BANQUET/ PREFUNCTION STORAGE 10,380 2,030 0.8 7.5 202.96 224.42 79.2 61.1 55.1 52.7 15.0 4.0 312.3 52.4 88.3 140.0 119.4 32.0 7.00 7'8" 3'8" 5'5" 1,407.0 -208/230 / 3 / 60 HEATING COIL DATA AIR SIDE COOLING COIL DATA AIR SIDE HP REMARKS OPER. WT. (LBS) AIR HANDLING UNIT SCHEDULE OR EQUIVALENT V / PH / Hz LOCATION UNIT TAG MANUFACTURER & MODEL NO. DIMENSIONS SERVICE CAPACITY (MBH) TOTAL MBH ELECTRICAL DATA WATER SIDE TOTAL CFM O.A. CFM ESP (IN) SUPPLY FAN EWT (°F) LWT (°F) GPM PD (FT) EWT (°F) LWT (°F) GPM PD (FT) HX-1 GEA KELVION - FG10X20-40 SNOWMELT MECHANICAL ROOM 248.0 140 120 26.0 5.1 105.9 130 23.0 4.2 11.1x4.6x21.4 - DIMENSIONS (WxLxH) HEAT EXCHANGER SCHEDULE OR EQUIVALENT REMARKS UNIT TAG MANUFACTURER & MODEL NO. PRIMARY SIDE SERVICE LOCATION TOTAL MBH SECONDARY SIDE L (IN) W (IN) H (IN) W GF-1 AXIOM - MF300 HEATING SYSTEM MECH ROOM 17 11.75 11.75 36.00 0.7 50 160 - GF-2 AXIOM - MF300 SNOWMELT MECH ROOM 17 11.75 11.75 36.00 0.7 50 160 - OR EQUIVALENT TANK VOLUME (GAL) V / PH /Hz 120 / 1 / 60 120 / 1 / 60 DIMENSIONS GLYCOL FEEDER SCHEDULE UNIT TAG MANUFACTURER & MODEL NO. LOCATION OPER. WEIGHT (LBS) ELECTRICAL DATA FREE FLOW (GPM) SERVICE LOCATION EDB (°F) LDB (°F) APD EWT (°F) LWT (°F) EDB (°F) EWB (°F) APD NOM.TONS TOT.CAP SENSIBLE L(IN) H(IN) W(IN) FC-1 CARRIER - 42DCA081 VIP ROOM CEILING 555 35 0.5 5.0 17.0 64.0 100.0 - - - 9.0 80.4 58.2 - 1.5 18.0 18.0 36.0 8.0 27.0 38.0 - TOTAL CFM FAN COIL UNIT SCHEDULE DIMENSIONS SERVICE TOTAL MBH V / PH / Hz SOLUTION AIR SIDE REMARKS ELECTRICAL DATA OPER. WT. (LBS) DX COOLING COIL DATA TOTAL MBH 208/1/60 DX COOLING CAPACITY (MBH) UNIT TAG MANUFACTURER & MODEL NO. LOCATION ELECTRIC HEATING COIL DATA WATER SIDE AIR SIDE O.A. CFM ESP (IN) KW - 410A REFRIGERANT V / PH / HZ WATTS MCA L(IN) H(IN) W(IN) AC-1 CU-5 RAS-15EKCV-UL RAS-15EACV-UL I.T. ROOM 1.5 15.0 30 0.75 - 20.0 208 / 1 / 60 - 13.0 9 41.0 13.0 38.0 LOW AMBIENT COOLING, VERIFY LOADS WITH I.T. PROVIDER PRIOR TO ORDERING TOTAL KW CFM LOCATION REMARKS UNIT TAG MANUFACTURER & MODEL NO. ELECTRICAL DATA OPER. WT. (LBS) SEER (EER) NOM. TONS DUCTLESS FAN COIL UNIT SCHEDULE OR EQUIVALENT DIMENSIONS TOTAL CAP. (MBH) FAN FLA DIA (IN) H (IN) ET-1 AMTROL AX-15(V) HEATING SYSTEM BOILER ROOM 7.8 2.5 12 19.25 12 50 140 111 1 ET-2 AMTROL AX-40(V) SNOWMELT BOILER ROOM 21.7 11.3 16.25 29 12 50 140 210 1 1 - ASME RATED SERVICE RELIEF PRESSURE (PSI) WATER TEMP (°F) OPER. WEIGHT (LBS) EXPANSION TANK SCHEDULE OR EQUIVALENT LOCATION TANK VOLUME (GAL) DIMENSIONS ACCEPT VOLUME (GAL) CHARGE PRESSURE (PSI) UNIT TAG MANUFACTURER & MODEL NO. REMARKS HP CFM ESP (IN.) HP CFM ESP (IN.) OA EAT SA EAT CAP. (kBTU) OA EAT SA EAT CAP. (kBTU) TYPE CORE TYPE % EFF. NO. TYPE SIZE (IN.) HP L(IN) WIN) H(IN) ERV-1 RENEWAIRE - HE2XINH LOWER LEVEL MECHANICAL CEILING 2 1005 0.40 2 805 0.40 -20 39 77.1 90 82 24.8 PLATE TWOL125- 00 60 4 MERV 8 PLEATED 20x20 1.5 72.0 48.0 40.0 442 1, 2, 3, 4 SUPPLY FAN DATA FILTER DATA SERVICE EXHAUST FAN DATA WINTER LOCATION ELECTRICAL DATA SUMMER HEAT RECOVERY MODULE 1 - FLEXIBLE DUCT CONNECTIONS, 2 - PERCENTAGE TIMER, 3 - EXHAUST ONLY DEFROST, 4 - PUSH BUTTON CONTROL 208-230 / 3 / 60 ENERGY RECOVERY UNIT SCHEDULE OR EQUIVALENT DIMENSIONS V / PH / Hz UNIT TAG MANUFACTURER & MODEL NO. OPER. WT. (LBS) REMARKS OR EQUIVALENT MIN. MAX. ZD-1 HONEYWELL ZD14X8 KITCHEN ZONE SEE FLOOR PLAN 14x8 750 0 530 0.07 25 N/A MOTORIZED DAMPER BD-1 HONEYWELL MARD10 F-3 SEE FLOOR PLAN 12"DIA 1400 0 1025 0.25 25 N/A MOTORIZED DAMPER INTERLOCKED WITH DUCT MOUNTED STATIC PRESSURE SENSOR MAX SOUND LVL (NC) UNIT TAG MANUFACTURER & MODEL NO. SERVICE LOCATION INLET SIZE (IN) CFM BYPASS OR ZONE DAMPER SCHEDULE MAX APD (IN. WC) OPER. WT. (LBS) VELOCITY (FPM) REMARKS OR EQUIVALENT V / PH / Hz HP\W P-1 GRUDFOS UPS 50-60 F BOILER SEE FLOOR PLANS INLINE 41 10.0 115 / 1 / 60 395 W 1, SPEED 2 P-2 GRUDFOS UPS 50-60 F BOILER SEE FLOOR PLANS INLINE 41 10.0 115 / 1 / 60 395 W 1, SPEED 2 P-3 GRUNDFOS UPS 80-80 F HOT WATER GEN SEE FLOOR PLANS INLINE 108 10.7 115 / 1 / 60 1050 W 1 P-4 GRUNDFOS MAGNA3 40- 120 F HEATING SYSTEM SEE FLOOR PLANS INLINE 56 23.0 115/ 1 / 60 442 W 1, 3 P-5 GRUNDFOS UPS 43-44 BFC SNOWMELT PRIMARY SEE FLOOR PLANS INLINE 26.0 10.0 115 / 1 / 60 215 W 1 P-6 GRUNDFOS UPS 50-44 F SNOWMELT SECONDARY SEE FLOOR PLANS INLINE 23 25.0 115 / 1 / 60 194 W 2 1- 30% PROPYLENE GLYCOL, 2 - 50% PROPYLENE GLYCOL, 3 - VARIABLE SPEED REMARKS TYPE TOTAL HEAD (FT) PUMP SCHEDULE ELECTRICAL DATA UNIT TAG MANUFACTURER & MODEL NO. SERVICE LOCATION GPM OR EQUIVALENT CAPACITY (MBH) GPM EWT (°F) LWT (°F) PD (FT) HP L(IN) H(IN) D(IN) UH-1 STERLING - HSB13211 GARAGE 1600 42.2 5.1 140 120 0.41 1/3 24 28 14 117 UH-2 STERLING - HSB13211 GARAGE 1600 42.2 5.1 140 120 0.41 1/3 24 28 14 117 UH-3 STERLING - HSB13211 GARAGE 1600 42.2 5.1 140 120 0.41 1/3 24 28 14 117 UH-4 STERLING - HSB04811 STORAGE 630 12.8 1.55 140 120 0.12 1/20 18 21 12 54 UH-5 STERLING - HSB04811 STORAGE 630 12.8 1.55 140 120 0.12 1/20 18 21 12 54 UH-6 STERLING - HSB04811 STORAGE 630 12.8 1.55 140 120 0.12 1/20 18 21 12 54 UH-7 STERLING - HSB04811 STORAGE 630 12.8 1.55 140 120 0.12 1/20 18 21 12 54 REMARKS UNIT TAG CFM V / PH / Hz HYDRONIC UNIT HEATER SCHEDULE MANUFACTURER & MODEL NO. LOCATION OPER. WT. (LBS) HEATING COIL DATA 115 / 1 / 60 115 / 1 / 60 115 / 1 / 60 115 / 1 / 60 115 / 1 / 60 DIMENSIONS 115 / 1 / 60 115 / 1 / 60 ELECTRICAL DATA UNIT TAG MANUFACTURER & MODEL NO. SERVICE LOCATION CFM SIZE (W"xH") FACE VELOCITY (FPM) PRESSURE DROP (IN SP) FREE AREA (ft²) FRAME TYPE FINISH REMARKS L-1 RUSKIN - ELF6375DX EF-6, AH-1, ERV-1 SEE FLOOR PLAN 3295 42x30 700 0.06 7.28 COORD. W/ARCH COORD. W/ARCH - L-2 RUSKIN - ELF6375DX GARAGE SEE FLOOR PLAN 2400 36x24 685 0.05 2.92 COORD. W/ARCH COORD. W/ARCH - L-3 RUSKIN - ELF6375DX GARAGE SEE FLOOR PLAN 2400 36x24 822 0.08 2.92 COORD. W/ARCH COORD. W/ARCH - L-4 RUSKIN - ELF6375DX F-1 SEE FLOOR PLAN 565 24x18 701 0.08 0.86 COORD. W/ARCH COORD. W/ARCH - L-5 RUSKIN - ELF6375DX F-2, F-3 SEE FLOOR PLAN 1395 36x18 702 0.06 1.98 COORD. W/ARCH COORD. W/ARCH - L-6 RUSKIN - ELF6375DX BUILDING RELIEF SEE FLOOR PLAN 2430 36x24 685 0.05 2.92 COORD. W/ARCH COORD. W/ARCH - L-7 COOK - GSG-33 EF-4, EF-7 SEE FLOOR PLAN 4800 36x33 - - - COORD. W/ARCH COORD. W/ARCH PART OF THE EF-3 ASSEMBLY, SHOWN HERE FOR REFERENCE L-8 RUSKIN - ELF6375DX LOWER FLOOR EXHAUST SEE FLOOR PLAN 895 30x18 549 0.05 0.86 COORD. W/ARCH COORD. W/ARCH LOUVER SCHEDULE OR EQUIVALENT OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO. USE MOUNTING LOCATION STYLE FRAME TYPE FINISH MAX SOUND LVL (NC) REMARKS A TITUS - OMNI 24x24 SUPPLY CEILING CEILING DIFFUSER COORD. W/ ARCH COORD. W/ ARCH 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS. B TITUS - OMNI 12x12 SUPPLY CEILING CEILING DIFFUSER COORD. W/ ARCH COORD. W/ ARCH 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS. C TITUS - 272RL SUPPLY WALL WALL DIFFUSER COORD. W/ ARCH COORD. W/ ARCH 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS. D TITUS - PAR 24x24 RETURN CEILING CEILING GRILLE COORD. W/ ARCH COORD. W/ ARCH 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS. E TITUS - 25RL RETURN WALL WALL GRILLE COORD. W/ ARCH COORD. W/ ARCH 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS. F TITUS - CT480 SUPPLY FLOOR FLOOR DIFFUSER COORD. W/ ARCH COORD. W/ ARCH 25 STEEL CONSTRUCTION. SEE DRAWINGS FOR LOCATIONS, SIZES, AND SPECIFIED CFMS. AIR DEVICE SCHEDULE SZ-1 WIRSBO hePEX SEE FLOOR PLAN 1,265 125 CONCRETE 5/8 9 9 5 187 197 1.6 14.7 9.0 1, 2 SZ-2 WIRSBO hePEX ROOF DECK 695 125 CONCRETE 5/8 9 5 5 185 195 1.6 8.1 8.7 1, 2 SNOWMELT SCHEDULE OR EQUIVALENT SURFACE FINISH TUBE DIA (IN) GPM/ MANIFOLD PD (FT) REMARKS TUBE SPACING (IN) NUMBER LOOPS ACTIVE LOOP LENGTH GPM/ LOOP 1 - 50% PROPYLENE GLYCOL, 2 - LEADER PIPING TO BE INSULATED LEADER LENGTH TOTAL LOOP LENGTH ZONE TAG MANUFACTURER & MODEL NO. SERVICE AREA (SQ FT) BTUH/ SQ FT TOTAL CFM O.A. CFM HP ESP (IN) RPM INPUT (MBH) OUTPUT (MBH) EAT °F LAT °F TOTAL MBH SENSIBLE MBH EAT °F WB EAT °F DB LAT °F WB LAT °F DB AMBIENT °F SUPERHEA T COIL ROWS REFRIGERANT L(IN) H(IN) W(IN) F-1 MODINE AIR - DCP125SMRNN40D2CN1FGG01 PRO SHOP MECH MEZZANINE 1,390 565 3/4 0.8 1800 90.0 72.0 33.0 100.0 80 4 33 33 57.0 85.0 50.0 63.0 90 8 3 R410A 114 24 35 797 MODULATING VALVE, DUCT MOUNTED SENSOR F-2 MODINE AIR - DCP350SMRNN40D2ET2MGG01 GRILLE ATTIC 4,820 525 5 0.8 1430 253.0 202.0 86.9 100.0 80 6 116 116 55 78 56 48 90 8 4 R410A 114 24 55 1,396 MODULATING VALVE, DUCT MOUNTED SENSOR F-3 MODINE AIR - DCP175SMRNN40D2CN1FGG01 UPPER LEVEL COMMON ATTIC 1555 870 3/4 0.8 1358 126.0 101.0 32.9 100.0 80 4 36 36 57.3 86.9 49.9 65.4 90 8 2 R410A 114 24 39 872 MODULATING VALVE, DUCT MOUNTED SENSOR, VERIFY VENT SIZE W/ MANUFACTURER PRIER TO INSTALL OPER. WT. (LBS) ELECTRICAL DATA V / PH / Hz SERVICE AFUE LOCATION DIMENSIONS HEATING CAPACITY COOLING CAPACITY FURNACE W/ DX COIL SCHEDULE 208 / 3 / 60 208 / 3 / 60 208 / 3 / 60 REMARKS UNIT TAG MANUFACTURER & MODEL NO. BLOWER DATA FLUE SIZE OR EQUIVALENT 06/14/16