Loading...
HomeMy WebLinkAboutB15-0274_A10.4_1460575740.pdfA4.3 A4.4 1 1 A4.1 2 1 A5.13 1 A5.2 1 A5.8 1 A5.9 1 A5.19 1 A5.16 1 2 3 4 6 7 8 A C E F G H I 5 J D 1 A5.3 1 A5.10 1 A5.12 1 A5.4 1 A5.1 1 A5.5 1 A5.7 1 A5.20 23' - 6 1/2" 30' - 5" 24' - 1 7/8" 1' - 8 5/8" 18' - 4" 14' - 6" 10' - 0" 122' - 8" 18' - 10 9/16" 1' - 0" 1' - 11 1/2" 2' - 0 1/2" 12' - 9 1/2" 1' - 8 1/2" 3' - 6" 10' - 0" MECH. 408 BATHROOM #1 407 CLOSET #1 405 MECH. 409 BEDROOM #1 404 BEDROOM #2 400 BATHROOM #2 401 1 A5.18 1 A5.11 B.O. GWB @ 9' - 7 3/4" A.F.F. B.O. GWB @ 8' - 0" A.F.F. B.O. DECKING @ 13' - 0 1/8" A.F.F. B.O. GWB @ 8' - 6" A.F.F. B.O. CEILING @ 10' - 10 1/2" A.F.F. B.O. CEILING @ 12' - 6 7/8" 2" / 12" 2" / 12" 2" / 12" 2" / 12" 2" / 12" B.O. GWB @ 62' - 7 3/4" USGS B.O. GWB @ 61' - 0" USGS B.O. GWB @ 61' - 6" USGS B.O. CEILING @ 63' - 10 1/2" USGS B.O. DECKING @ 66' - 0 3/16" USGS B.O. DECKING @ 66' - 0 3/16" USGS B.O. GWB @ 11' - 7 7/8" A.F.F. B.O. GWB @ 9' - 7 3/8" A.F.F. B.O. GWB @ 11' - 7 7/8" A.F.F. B.O. GWB @ 9' - 7 3/8" A.F.F. B.O. GWB @ 10' - 7 3/8" A.F.F. B.O. GWB @ 8' - 2 7/8" A.F.F. B.O. GWB @ 9' - 4 3/4" A.F.F. B.O. GWB @ 8' - 2 3/4" A.F.F. B.O. GWB @ 10' - 7 3/8" A.F.F. B.O. GWB @ 9' - 9 7/8" A.F.F. POWER SHADE @ CEILING POWER SHADE @ CEILING B.O. GWB @ 9' - 6 3/8" A.F.F. B.O. GWB @ 62' - 6 3/8" USGS 2" / 12" B.O. DECKING @ 13' - 0 1/8" A.F.F. 1 A5.6 RW10S RW10S RW8E RW12E RW8E RW10S RW8E RW12E+ 1 A5.17 1 A5.15 1 A5.14 2 A6.6 1 A6.6 1 A6.9 2 A6.9 11 A6.5 3 A6.8 3 A6.9 5 A6.9 8 A6.10 11 A6.10 B AA BB 1A 2A 3A 4A 5A 6A 7A Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 8/3/2015 13:11:01 A10.4 LEVEL 4 RCP AG HB 165 FOREST RD VAIL, CO 07/27/2015 VAIL VILLAGE FILING 1, BLOCK 7, LOT 29 PRELIMINARY BUILDING PERMIT SET 1/4" = 1'-0" 1 LEVEL 4- UPPER LEVEL AND ROOF DECK REFLECTED CEILING PLAN GENERAL NOTES: 1) EXTERIOR LIGHTING: 1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 20 LIGHTS ARE ALLOWED. 20 EXTERIOR LIGHTS MORE THAN 18" ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES. (1) HUBBARTON FORGE AIRIS MEDIUM SCONCE (TYPE B) LIGHTS PROVIDED 8' - 0" ABOVE F.F @THIS LEVEL (12) CEILING MOUNTED HEVI LITE HL-384 MONOPOINT (TYPE M) LIGHTS PROVIDED @ THIS LEVEL (18) WAC LIGHTING WL-LED200 STEP LIGHT (TYPE Q) LIGHTS PROVIDED LESS THAN 18" ABOVE F.F. @ THIS LEVEL ________________________________________ 13 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18" ABOVE GRADE AT THIS LEVEL ________________________________________ 50% OF NEW LIGHTING COMPLIANT WITH INTERNATIONAL ENERGY CONSERVATION CODE (IECC). 0' 4' 8' 16' 32' No. Revision Date Revision Description 04/13/16