HomeMy WebLinkAboutB15-0274_A6.1_1460575800.pdf1 STORAGE WEST GARAGE RE: STRUCT. RE: STRUCT. GS14 ASSEMBLY APPROX. LINE OF EXISTING GRADE RE: STRUCT. APPROX. LINE OF BEDROCK TEMPORARY SHORING STONE VENEER OVER 3D DRAINAGE MATERIAL OVER AIR AND WATER INFILTRATION BARRIER CONT. @ WALL. LAP OVER BITUTHANE FLASHING, STEEL ANGLE, & MIRADRAIN DRAINAGE MEDIUM @ FOUNDATION. DRAINAGE MEDIUM CONT. UNDER B.O. STONE OR PROVIDE WEEP SO THAT DRAINAGE MEDIUM CAN DRAIN AT B.O. WALL. 5" CONC. SLAB ON GRADE WITH IN FLOOR RADIANT HEAT 4" CONT. RIGID FOAM INSULATION PANEL UNDER SLAB W/ 2" VERTICAL PIECE OF EDGE AT SLAB W/ BEVEL CUT TOP AS SHOWN CONCRETE FOUNDATION WALL RE: STRUCTURAL DRAWINGS CONCRETE FOUNDATION FOOTER RE: STRUCTURAL DRAWINGS 4" GRAVEL BED UNDER CONCRETE SLAB PER SOILS ENGINEER RECOMMENDATIONS/STRUCT. INSULATION RE: SPEC MIRA DRAIN DRAINAGE MEDIUM OVER R-15 3" RIGID FOAM INSULATION PANEL OVER WATERPROOF MEMBRANE RE: SPEC. ALTERNATE INSULATION/ DRAINAGE MEDIUM MAY BE PROPOSED PER SPEC. 1/2" EXPANSION JOINT WITH BEVEL CUT TOP OF 2" FOAM @ SLAB EDGE. PROVIDE SEALANT JOINT BTW SLAB AND CONC. WALL TO PREVENT RADON GAS INFILTRATION 3" INSULATION PANEL CONSISTING OF: 2 3/8" RIGID FOAM GLUED TO 5/8" PLYWOOD TOP SHEET R-10 +/- SCREW TO WOOD STUD W 5" SCREWS @ A MIN OF 8" O.C. PER MANUFACTURES RECOMMENDATIONS. RE: SPEC RIGID PERFORATED PIPE SURROUNDED BY FILTER FABRIC AND A MIN. OF 4 INCHES OF DRAIN GRAVEL SLOPED 1% MIN. TO DAYLIGHT PER SOILS REPORT. RE SOILS REPORT AND CIVIL DESIGN FOR ADDITIONAL FOUNDATION & PERIMETER DRAIN REQUIREMENTS & SPEC W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. LAP ICE AND WATER SHIELD OVER B.O. INSULATION PANEL 6" MIN. AND CONTINUE REMAINDER OF 36" ROLLER UP WALL. 10 MIL VAPOR BARRIER TURNS UP WALL MECH FASTEN AND SEAL TO WALL. SEAL ALL JOINTS AND PENETRATIONS TYP. SMART MEMBRANE VAPOR BARRIER RE: SPEC MIRA DRAIN DRAINAGE MEDIUM OVER WATERPROOF MEMBRANE RE: SPEC LEVEL 2 - GARAGE & BEDROOMS 33' - 0" LEVEL 1 - GUEST SUITE & EXERCISE 19' - 6" 2 LEVEL 2 - GARAGE & BEDROOMS 33' - 0" LEVEL 1 - GUEST SUITE & EXERCISE 19' - 6" HOBBY ROOM WEST GARAGE RE: STRUCT. GS14 ASSEMBLY PFSM FLASHING RE: SPEC, APPROX. LINE OF BEDROCK PERMANENT SHORING WALL RE: STRUCT. RE: STRUCT. SHEET DRAIN CONNECTION TO SOLID PVC PIPE AT INSIDE EDGE OF FOOTING RE: CIVIL DESIGN HYDRODUCT COIL 600 PREPRUFE 300R HYDRODUCT 200 R-15 3" RIGID FOAM INSULATION PANEL OVER WATERPROOF MEMBRANE RE: SPEC. ALTERNATE INSULATION/ DRAINAGE MEDIUM MAY BE PROPOSED PER SPEC. SWELL TYPE WATER STOP RE: SPEC. INSULATION RE: SPEC 3" INSULATION PANEL CONSISTING OF: 2 3/8" RIGID FOAM GLUED TO 5/8" PLYWOOD TOP SHEET R-10 +/- SCREW TO WOOD STUD W 5" SCREWS @ A MIN OF 8" O.C. PER MANUFACTURES RECOMMENDATIONS. RE: SPEC LAP ICE AND WATER SHIELD OVER B.O. INSULATION PANEL 6" MIN. AND CONTINUE REMAINDER OF 36" ROLLER UP WALL. SMART MEMBRANE VAPOR BARRIER RE: SPEC APPROX. 4" OF GUNNITE APPLIED TO FACE OF BEDROCK CEMENT BOARD PANEL SIDING MOUNTED WITH CONCEALED FASTENERS TO VERTICAL RUNNERS 6" MIN. PREPRUFE LAPS UP GRADE SIDE OF TWO SIDED POUR FOUNDATION WALL 18" MIN. W.P. MEMBRANE LAPS OVER PREFRUFE AND JOINED WITH BITUTHANE TAPE SEE 1/A6.1 FOR TYPICAL SLAB ASSEMBLY PERFORATED PVC PIPE TO COLLECT GROUND WATER RE: CIVIL DESIGN SOLID PVC PIPE TO COLLECT DRAINAGE FROM SHEET DRAINAGE SYSEM RE: CIVIL DESIGN APPROX. LINE OF EXISTING GRADE 3 LEVEL 2 - GARAGE & BEDROOMS 33' - 0" LEVEL 1 - GUEST SUITE & EXERCISE 19' - 6" FAMILY ROOM MUDROOM DRIVEWAY/ AUTO-COURT TRENCH DRAIN RE: SPEC. & MECH. DESIGN RE: STRUCT. RE: STRUCT. GS14 ASSEMBLY TYP. STONE VENEER WALL ASSEMBLY SEE 1/ A6.1 POUR STOP RE: STRUCT. RE: STRUCT. SEE 1/A6.1 FOR TYPICAL SLAB ASSEMBLY SEE 3/A6.1 FOR TYPICAL ONE-SIDED POUR ASSEMBLY 8 RE: STRUCT. LEVEL 3A - MAIN LEVEL 39' - 9" RE: STRUCT. LEVEL 2A - BEDROOMS 26' - 7 1/2" LEVEL 1A - EXERCISE & BEDROOM 13' - 4 1/2" MECHANICAL RM. BEDROOM #4 EXTERIOR LIVING ROOM STL. BEAM RE: STRUCT. FSB14 ASSEMBLY FSB14 ASSEMBLY DSB10 ASSEMBLY 3 1/2" RE: STRUCT. RE: STRUCT. APPROX. LINE OF BEDROCK TEMPORARY SHORING RE: STRUCT. 6" SEE 1/A6.1 FOR TYP. TWO SIDED POUR AND TEMP. SHORING WALL DETAIL NOTES. POUR STOP 6" MIN I H LEVEL 2A - BEDROOMS 26' - 7 1/2" LEVEL 1A - EXERCISE & BEDROOM 13' - 10 5/8" LEVEL 3A - MAIN LEVEL 39' - 9" MECHANICAL RM. BEDROOM #4 LIVING RM. FSB14 ASSEMBLY FSB14 ASSEMBLY APPROX. LINE OF BEDROCK RE: STRUCT. 6" SEE 1/A6.1 FOR TYPICAL SLAB ASSEMBLY TYPICAL STONE VENEER WALL ASSEMBLY. SEE DETAIL 1/A6.1 RE: STRUCT. RE: STRUCT. RE: STRUCT. SEE 3/A6.1 FOR TYPICAL ONE-SIDED POUR ASSEMBLY 6" MIN. APPROX. LINE OF EXISTING GRADE INSULATION PANEL RE: SPEC. I LEVEL 2 - GARAGE & BEDROOMS 33' - 0" LEVEL 1 - GUEST SUITE & EXERCISE 18' - 10 5/8" RE: STRUCT. H MUDROOM FAMILY RM. RE: STRUCT. GS14 ASSEMBLY APPROX. LINE OF BEDROCK GARAGE STORAGE SEE 3/A6.1 FOR TYPICAL SINGLE SIDED POUR ASSEMBLY SEE 1/A6.1 FOR TYPICAL SLAB ASSEMBLY RE: STRUCT. RE: STRUCT. APPROX. LINE OF EXISTING GRADE Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1 1/2" = 1'-0" 8/3/2015 13:10:02 A6.1 FOUNDATION DETAILS AG HB 165 FOREST RD VAIL, CO 07/27/2015 VAIL VILLAGE FILING 1, BLOCK 7, LOT 29 PRELIMINARY BUILDING PERMIT SET 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ WEST GARAGE GRID 1 - GS14 ASSEMBLY 1 1/2" = 1'-0" 3 FOUNDATION DETAIL @ WEST GARAGE GRID 2 & AUTO COURT - GS14 ASSEMBLY 1 1/2" = 1'-0" 5 FOUNDATION DETAIL @ FAMILY ROOM & AUTO COURT GRID 3 - GS14 ASSEMBLY 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ MECHANICAL RM. GRID 8 FSB14 & DSB10 ASSEMBLY 1 1/2" = 1'-0" 7 FOUNDATION DETAIL @ BEDROOM #4 GRID I - FSB14 ASSEMBLY 1 1/2" = 1'-0" 4 FOUNDATION DETAIL @ FAMILY ROOM GRID I - GS14 ASSEMBLY No. Revision Date Revision Description 04/13/16