Loading...
HomeMy WebLinkAboutB15-0274_A6.5_1460575800.pdfLEVEL 3 - MAIN LEVEL FLOOR PLAN 43' - 0" B STL. BEAM RE: STRUCT. FSW8 ASSEMBLY TYP. METAL PANEL SYSTEM: 3/4" PLYWOOD SCREWED TO NAIL BASE WITH METAL PANELS SILICONE GLUED TO PLYWOOD SEE ELEVATIONS FOR PANEL DIMENSIONS REGLET BLOCKING RE: STRUCTURAL 3" INSULATION PANEL CONSISTING OF: 2 3/8" RIGID FOAM GLUED TO 5/8" PLYWOOD TOP SHEET R-10 +/- SCREW TO WOOD STUD W 5" SCREWS @ A MIN OF 8" O.C. PER MANUFACTURES RECOMMENDATIONS. RE: SPEC G LEVEL 3 - MAIN LEVEL FLOOR PLAN 43' - 0" STL. BEAM RE: STRUCT. FSW8 ASSEMBLY 1' - 0 1/16" 6 3/8" LED LIGHT STRIP LOCATION VERTICAL CURTAIN WALL MEMBER BEYOND GLASS HORIZONTAL CURTAIN WALL MEMBER STEEL ANGLE W/ SLOTTED CONNECTION RE: CURTAIN WALL MANUF. BLOCKING REGLET TUBE STEEL RE: STRUCT. B LEVEL 3 - MAIN LEVEL FLOOR PLAN 43' - 0" STL. BEAM RE: STRUCT. WINE RM. SHOWER FSW8 ASSEMBLY BACKER BOARD TILE WALL FINISH RE: INTERIORS DOCUMENTS DSB8 ASSEMBLY SOLID BLOCKING RE: STRUCT. G RW10S ASSEMBLY STL. BEAM RE: STRUCT. VERTICAL CURTAIN WALL MEMBER BEYOND BEDROOM #1 GLASS HORIZONTAL CURTAIN WALL MEMBER METAL FLASHING/CAP STANDING SEAM METAL ROOFING VYCOR ICE AND WATER SHIELD (USE HIGH TEMPERATURE AT ALL METAL ROOFS) - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE EAVE AND 3' ABOVE AND TO THE SIDE OF CRICKETS, VALLEYS, AND ROOF TRANSITIONS RE: SPEC STEEL ANGLE W/ SLOTTED CONNECTION RE: CURTAIN WALL MANUF. BLOCKING PFSM DRIP EDGE FLASHING TO MATCH ROOF BLOCKING AS REQ'D SHADE POCKET TO COORDINATE DIMENSIONS WITH SHADE MANUFACTURER RE: RCP FOR LOCATION & SIZE REGLET STEEL PLATE LED LIGHT STRIP LOCATION 1' - 0 1/4" 2 5/8" 7" CLR 11" CLR EXTERIOR D 1/2" RSB12EP ASSEMBLY 1/4" PFSM FLASHING CAP SEE 3/A6.1 FOR TYP. CEMENT BOARD ASSEMBLY SEE 2/A6.5 FOR TYP. PEDESTAL ROOF ASSEMBLY 1/2" STEEL PLATE WRAPS WINDOW STEEL BEAM RE: STRUCT. SLOPE TO CENTER DRAIN D STEEL BEAM RE: STRUCT. RSB12EP ASSEMBLY PFSM FLASHING CAP SEE 3/A6.1 FOR TYP. CEMENT BOARD ASSEMBLY SEE 2/A6.5 FOR TYP. PEDESTAL ROOF ASSEMBLY STL BEAM. RE: STRUCT. D LEVEL 3 - MAIN LEVEL FLOOR PLAN 43' - 0" STL. BEAM RE: STRUCT. DSB8 ASSEMBLY SEE 3/A6.1 FOR TYP. CONC. PANEL ASSEMBLY FSB12 ASSEMBLY C STEEL WINDOW HEAD RE: WINDOW SCHEDULE CONT. LEDGER RE: STRUCT. PROVIDE BLOCKING FOR WINDOW HEAD ATTACMENT RIP PLATE PER DECK SLOPE POUR STOP 1 1/2" LEVEL 4 - UPPER LEVEL & ROOF DECK 53' - 0" W STL BEAM RE: STRUCT. MECH. MASTER CLOSET RSB12EP ASSEMBLY FSB12 ASSEMBLY DROPPED CEILING FOR MECHANICAL CHASE HYDROFLEX 30 PROTECTION BOARD OVER HOT LIQUID APPLIED W.P. MEMBRANE 5/8" SECURE ROCK OVER TAPERED INSULATION. SEE 3/A6.1 FOR TYP. CEMENT BOARD WALL ASSEMBLY ROOF TILES ON PEDESTALS W/ SNOW MELT ATTACHED OVER TAPERED 60 PSF INSULATION PANEL LEVEL 2 - GARAGE & BEDROOMS 33' - 0" RE: STRUCT. GS14 ASSEMBLY C WEST GARAGE HOBBY ROOM EPOXY FINISH SLOPE TO DRAIN ASB14 ASSEMBLY EXTERIOR EXTERIOR STEEL BEAM RE: STRUCT. STEEL WINDOW RE: WINDOW SCHEDULE W.P. CONT. UNDER DOOR SILL DOOR SILL SET IN BED OF SEALANT OVER FLASHING LEVEL 3 - MAIN LEVEL FLOOR PLAN 43' - 0" DSB8 ASSEMBLY STL. BEAM RE: STRUCT. A 2" x 1/2" TOP RAIL 4" X 4" X 1/2" STEEL PLATE BETWEEN STANCHIONS (2) 3" X 1/2" STEEL STANCHIONS 4" 4" O.C. 3/8" STEEL PLATE FOR DECK FASCIA PROVIDE DRAINAGE MEDIUM AND WEEP @ EDGE OF LVL BEAM CUSTOM METAL GUTTER PER DIMS SHOWN INFILL BEAM W/ SOLID BLOCKING RE: STRUCT. STEEL ANGLE ATTACHED TO BLOCKING BELOW W/ COUNTER SUNK SCREWS . LAG BOLT INTO RIM BLOCKING AS REQUIRED PER STRUCTURAL POUR STOP STEEL SLEEVE WELDED TO IMBED PLATE 6" X 6" X 1/2" STEEL IMBED PLATE WITH STUDS RUN W.P. MEMBRANE UP SLEEVE STANCHIONS WELD TO EITHER SIDE OF SLEEVE CUSTOM LIGHT BOX WELDED BTW STANCHIONS ALL THREAD WELDED TO CORNERS OF INBED PLATE BLOCKING BELOW INBED PLATE BOLTS TO ALL THREAD TO HOLD IMBED PLATE IN PLACE 1 1/2" X 3/8" STEEL RAILS BETWEEN STANICHIONS @ 4" O.C. 3'-0" A.F.F. MIN. 3" 4" 2" LED LAMP LOCATION DRILL THROUGH IMBED PLATE AND DECKING TO ROUTE POWER FOR LIGHT G LEVEL 4 - UPPER LEVEL & ROOF DECK 53' - 0" FSB12 ASSEMBLY STL. BEAM RE: STRUCT. VERTICAL CURTAIN WALL MEMBER BEYOND BUTT GLAZED GLASS HORIZONTAL CURTAIN WALL MEMBER STEEL ANGLE W/ SLOTTED CONNECTION RE: CURTAIN WALL MANUF. SOLID BLOCKING HORIZONTAL MULLION CAP PROVIDED BY CURTAIN WALL MANUF. LED LIGHT STRIP LOCATION STEEL FINISH PLATE LEVEL 2A - BEDROOMS 26' - 7 1/2" STL. COLUMN BEYOND RE: STRUCT. DSB10 ASSEMBLY STL. BEAM RE: STRUCT. RE: STRUCT 3/8" STEEL PLATE FOR DECK FASCIA PROVIDE DRAINAGE MEDIUM AND WEEP @ EDGE OF LVL BEAM SEE 6/A6.5 FOR CUSTOM GUTTER STEEL SLEEVE BEYOND WELDED TO STEEL BEAM STANCHIONS WELD TO EITHER SIDE OF SLEEVE 3 1/2" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1 1/2" = 1'-0" 8/3/2015 13:10:22 A6.5 DETAILS AG HB 165 FOREST RD VAIL, CO 07/27/2015 VAIL VILLAGE FILING 1, BLOCK 7, LOT 29 PRELIMINARY BUILDING PERMIT SET 1 1/2" = 1'-0" 5 WALL/FLOOR DETAIL @ AUTO-COURT GRID B - FSW8 ASSEMBLY 1 1/2" = 1'-0" 9 WALL/FLOOR DETAIL @ AUTO-COURT CURTAIN WALL GRID G - FSW8 ASSEMBLY 1 1/2" = 1'-0" 8 WALL/FLOOR DETAIL @ AUTO-COURT CEILING GRID B - DSB8 & FSW8 ASSEMBLY 1 1/2" = 1'-0" 11 ROOF/WALL DETAIL @ BEDROOM #1 GRID G - RW10S ASSEMBLY 1 1/2" = 1'-0" 3 ROOF/WALL DETAIL @ MASTER BED GRID D - RSB12EP ASSEMBLY 1 1/2" = 1'-0" 7 WALL/FLOOR DETAIL @ ROOF DECK GRID D - RSB12EP ASSEMBLY 1 1/2" = 1'-0" 1 DECK/WALL DETAIL @ MASTER BED DECK GRID C - DSB8 & FSB12 ASSEMBLY 1 1/2" = 1'-0" 2 WALL/FLOOR DETAIL @ HER MASTER CLOSET & MECHANICAL - FSB12 & RSB12EP ASSEMBLY 1 1/2" = 1'-0" 12 WALL/FLOOR DETAIL @ WEST GARAGE GRID C - GS14 & ASB14 ASSEMBLY 1 1/2" = 1'-0" 6 DECK FLOOR & RAIL @ MASTER BED DECK - DSB8 ASSEMBLY 1 1/2" = 1'-0" 10 WALL/FLOOR DETAIL @ CURTAIN WALL GRID G - FS12B ASSEMBLY 1 1/2" = 1'-0" 4 DECK/FLOOR DETAIL @ BEDROOM #3 - DSB10 ASSEMBLY No. Revision Date Revision Description 04/13/16