HomeMy WebLinkAboutB15-0274_Asbestos Report_1438723560.pdf·, P.O.Box 1230 Cell 970-270-3689 Clifton,CO.81520-1230 Home Phone 970-464-5265 A &D Asbestos Testing and Consulting John R.Peterman *********** INSPECTION REPORT PREPARED FOR: Shaeffer Hyde Construction P.O.Box 373 Vail,Co.81658 LOCATION: Residence 165 Forest Rd. Vail,Co. REPORT PREPARED BY: John R.Peterman Inspector Manager COLORADO Certificate No.6601 COLORADO Registration #ACF-16522 2 A &D Asbestos Testing and Consulting John R.Peterman Asbestos Testing and Consulting INTRODUCTION: On May 20,2015 an inspection/survey was conducted and 14 bulk samples were collected from: Residence 165 Forest Rd. Vail,Co. The purpose of the inspection/survey was to locate and sample suspected Asbestos containing materials that might be present in the residence that is planned for demolition. The inspection was made,and the samples were collected by John R Peterman,an A.H.E.R.A.and State of Colorado Certified Asbestos Inspector.Great care was taken during the inspection and sampling to be as accurate as possible.It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation for unseen conditions or stored items. All samples were analyzed by DCM Science Lab in Wheat Ridge, CO.This laboratory is deemed "Proficient"in the E.P.A.Quality Assurance (QA)program for the determination of asbestos in bulk materials,and is accredited by the American Hygiene Association (AHA). SAMPLING PROTOCOL: A random sampling scheme was used to sample the suspect materials that were discovered.Ifduring any future demolition or renovation work, suspect material is discovered that hasn't been sampled and would be disturbed,work should be halted until the material has been tested. 3 A &D Asbestos Testing and Consulting John R.Peterman Asbestos Testing and Consulting Residence 165 Forest Rd. Vail,Co. BUILDING DESCRIPTION: The residence at 165 Forest Rd.is planned for demolition.The exterior walls are covered with wood siding and soffits,rock and mortar and stucco.The roof is covered with wood shake shingles.The interior walls are covered with two types of sheetrock one with a troweled on texture and one with a light texture.The ceiling is covered with sheetrock like the walls.The floor is covered in wood,ceramic tiles,carpet,stone tile WI mortar and painted concrete.The heating is provided by a hot water system no suspect materials were visible on the heating system. CONCLUSIONS &RECOMMENDATIONS: Laboratory analysis of the bulk samples indicates that no Asbestos was detected in any of the samples. 4 , Date:May 29,2015 Location:Residence 165 Forest Rd.Vail,Co. SAMPLE LOCATIONS SAMPLE NUMBER AREA SAMPLE REMOVED FROM DESCRIPTION FRIABLE 165FR-B 001 TF W.Bedroom Closet Wall Composite Sheetrock WI Texture No 165FR-B 002 TF Livingroom Wall Composite Sheetrock WI Texture No 165FR-B 003 MF Ski Room WaU Composite Sheetrock WI Texture No 165FR-B 004 MF Rear Entry Wall Composite Sheetrock WI Texture No 165FR-B 005 BF Game Room Wall Composite Sheetrock WI Texture No 165FR-B 006 BF Under Stairs Closet Wall Composite Sheetrock WI Texture No 165FR-B 007 BF W.Bedroom Closet Wall Composite Sheetrock WI Texture No 165FR-B 008 MF Laundry Room Wall Composite Sheetrock WI Texture No 165FR-B 009 MF Hallway Closet Wall Composite Sheetrock WI Texture No 165FR-B 010 E.Exterior Wall Exterior Stucco No 165FR-B 011 N.Exterior Wall Exterior Stucco No 165FR-B 012 N.Exterior Wall Exterior Stucco No 165FR-B 013 N.Exterior Wall Exterior Stucco No 165FR-B 014 W.Exterior Wall Exterior Stucco No Key:TF-Top Floor MF-Middle Floor BF-Bottom Floor Date:May 29,2015 Location:Residence 165 Forest Rd.Vail,Co. SAMPLE RESULTS SAMPLE NUMBER DESCRIPTION ASBESTOS TYPE % 165FR-B 001 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 002 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 003 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 004 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 005 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 006 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 007 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 008 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 009 Composite Sheetrock WI Texture No Asbestos Detected 0 165FR-B 010 Exterior Stucco No Asbestos Detected 0 165FR-B 011 Exterior Stucco No Asbestos Detected 0 165FR-B 012 Exterior Stucco No Asbestos Detected 0 165FR-B 013 Exterior Stucco No Asbestos Detected 0 165FR-B 014 Exterior Stucco No Asbestos Detected 0 Date:May 29,2015 Location:Residence 165 Forest Rd.Vail,Co. SUSPECT MATERIAL CONDITION SAMPLE NUMBER TYPE OF SUSPECT MATERIAL OVERALL DAMAGED %TYPE OF CONDITION DAMAGE 165FR-B 001 Surfaceing Good No 0 N/A 165FR-B 002 Surfaceing Good No 0 N/A 165FR-B 003 Surfaceing Good No 0 N/A 165FR-B 004 Surfaceing Good No 0 N/A 165FR-B 005 Surfaceing Good No 0 N/A 165FR-B 006 Surfaceing Good No 0 N/A 165FR-B 007 Surfaceing Good No 0 N/A 165FR-B 008 Surfaceing Good No 0 N/A 165FR-B 009 Surfaceing Good No 0 N/A 165FR-B 010 Surfaceing Good No 0 N/A 165FR-B 011 Surfaceing Good No 0 N/A 165FR-B 012 Surfaceing Good No 0 N/A 165FR-B 013 Surfaceing Good No 0 N/A 165FR-B 014 Surfaceing Good No 0 N/A Date:May 29,2015 Location:Residence 165 Forest Rd.Vail,Co. POTENTIAL FOR DISTURBANCE SAMPLE NUMBER ACCESSABILITY POTENTIAL INFLUENCE BY POTENTIAL PLENUM YES I NO CONTACT VIBRATION AIR EROSION 165FR-B 001 Yes High Low Low No 165FR-B 002 .Yes High Low Low No 165FR-B 003 Yes High Low Low No 165FR-B 004 Yes High Low Low No 165FR-B 005 Yes High Low Low No 165FR-B 006 Yes High Low Low No 165FR-B 007 Yes High Low Low No 165FR-B 008 Yes High Low Low No 165FR-B 009 Yes High Low Low No 165FR-B 010 Yes High Low Low No 165FR-B 011 Yes High Low Low No 165FR-B 012 Yes High Low Low No 165FR-B 013 Yes High Low Low No 165FR-B 014 Yes High Low Low No CLIENT: A&D ASBESTOS TESTING AND CONSULTING P.O.BOX 1230 CLIFTON,CO 81520-1230 DCMSL CLIENT S~PLE S~LE NUMBER NUMBER S~LE DATE DESCRIPTION 5-20-15 A WIllTEPAINT B.TAN FIBROUS C.WIllTE TEXTURE D.WHITE DRYWALL 5-20-15 A WIllTE PAINT B.TANFIBROUS C.WIllTE TEXTURE D.WIllTEDRYWALL 5-20-15 A WIllTEPAINT B.TANFIBROUS C.WIllTE TEXTURE D.WHITEDRYWALL 5-20-15 A.WIllTEPAINT B.TAN FIBROUS C.WIllTE TEXTURE D.WIllTE DRYWALL 5-20-15 A WIllTEPAINT B.WIllTE TEXTURE C.TAN FIBROUS D.WIllTEDRYWALL a_Rf~' 12421 W.49TH AVEiNUE,UNIT #6 WHEAT RIDGE,CO 80033 (303)463-8270 BULK ASBESTOS TEST REPORT PAGE IOF4 ANALYSIS DATE: REPORTING DATE: RECEIPT DATE: CLIENT JOB NO.: PROJECT TITLE: DCMSL PROJECT: PERCENTAGE COMPOSITION BY VISUAL ESTlMA TE PERCENT OFS~LE ASBESTOS TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS 5-26-15 5-27-15 5-21-15 RESIDENCE 165FOREST RD -VAIL,CO ADAT963 TOTAL ASBESTOS OTHER FIBROUS NON-FIBROUS TOTAL PERCENTAGE IDENTIFIED MATERIALS -1 16SFR-B-001 -2 I65FR-B-002 -3 I65FR-B-003 -4 I65FR-B-004 -s 16SFR-B-OOS 2.0%NO 4.0%NO 12.0%NO 82.0%NO 3.0%ND 40%NO 6.0%NO 87.0%NO 3.0%NO 5.0%NO 60%NO 86.0%NO 2.0%NO 4.0%NO 6.0%NO 88.0%NO 20%NO 4.0%NO 5.0%NO 89.0%NO NO NO NO NO ND 0.0 100.0 100.0 100.0 0.0 100.0 0.0 100.0 100.0 1.0 99.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 0.0 100.0 100.0 1.0 99.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 0.0 100.0 100.0 1.0 99.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 0.0 100.0 100.0 1.0 99.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 LO 99.0 100.0 CLIENT: A&D ASBESTOS TESTING AND CONSULTING P.O.BOX 1230 CLIFTON,CO 81520-1230 DCMSL CLlENT SAMPLE SAMPLE NUMBER NUMBER SAMPLE DATE DESCRIPTION 5-20-15 A.WHITE PAINT B.WHITE TEXTURE C.TAN FIBROUS D.WIllTE DRYWALL 5-20-15 A.WHITE PAINT B.WIllTE TEXTURE C.TAN FIBROUS D.WIllTE DRYWALL 5-20-15 A.WHJTE PAINT B.WIllTE TEXTURE C.WIllTE DRYWALL MUD D.TAN FIBROUS E.WHITE DRYWALL 5-20-15 A.WIllTE PAINT B.WHITE TEXTURE C.WlllTEDRYWALLMUD D.TAN FIBROUS E.WHITE DRYWALL 5-20-15 A.WIllTE PAINT B.wurrs CONCRETE -6 165FR-B-006 -7 16SFR-B-007 -8 165FR-B-008 -9 J65FR-B-009 -10 165FR-B-OIO §}_J?I9.N¥'.-_JNe 1.2421W.49T.H AVENUE,UNIT #6 WHEAT RIDGE,CO 80033 (303)463-8270 BULK ASBESTOS TEST REPORT PAGE 2 OF 4 ANALYSIS DATE: REPORTING DATE: RECEIPT DATE: CLIENT JOB NO.: PROJECT TITLE: DCMSL PROJECT: 5-26-15 5-27-15 5-21-15 RESIDENCE 165FOREST RD -VAIL,CO ADAT963 PERCENTAGE COMPOSITION BY VISUAL ESTIMATE PERCENT OF SAMPLE ASBESTOS TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS 2.0%ND 3.0%ND 5.0%ND 90.0%ND 2.0%NO 5.0%ND 6.0%NO 87.0%ND 2.0%NO 4.0%ND 5.0%ND 6.0%ND 83.0%NO 1.0%ND 2.0%ND 3.0%NO 6.0%ND 88.0%NO 15.0%NO 85.0%NO TOTAL ASBESTOS OTHER FffiROUS NON-FIBROUS TOTAL PERCENTAGE IDENTIFIED MATERIALS NO ND NO ND NO 0.0 100.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 l.0 99.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 1.0 990 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 1.0 99.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 1.0 99.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 CLIENT: A&D ASBESTOS TESTlNG AND CONSULTlNG P.O.BOX 1230 CLIFTON,CO 81520-1230 DCMSL CLIENT SAMPLE SAMPLE NUMBER NUMBER SAMPLE DATE DESCRJPTION 5-20-15 A.WHlTE PAlNT B.WHJTE CONCRETE 5-20-15 A.GREY CONCRETE B.WHJTE CONCRETE 5-20-15 A.WHITE PAlNT B.WHITE CONCRETE C.GREY CONCRETE 5-20-15 A.WHITE PAlNT B.GREY CONCRETE C.WlllTE CONCRETE -II 16SFR-B-0Il -12 I6SFR-B-0 12 -13 165FR-B-013 -14 165FR-B-014 FOR CALCULATION PURPOSES,TRACE (TR)IS ASSUMED TO BE O.S%. (1)-lNSEP ARABLE LAYERS NO -NONE DETECTED a_J19.lr~. -u.:tIOMlOIttl~ 12421 W.49Tf,IAVENUE,UNITN6 Wf,lEAT RIDGE,CO 80033 (303)463-8270 BULK ASBESTOS TEST REPORT PAGE 3OF 4 ANALYSIS DATE: REPORTlNG DATE: RECEIPT DATE: CLIENT JOB NO.: PROJECT TITLE: DCMSL PROJECT: 5-26-15 5-27-15 5-21-15 RESIDENCE 165FOREST RD -VAIL,CO ADAT963 PERCENTAGE COMPOSITION BY VISUAL ESTIMATE PERCENT OF SAMPLE ASBESTOS TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS 15.0%NO 85.0%NO 30.0%NO 70.0%NO 15.0%NO 25.0%ND 60.0%ND 15.0%NO 20.0%NO 65.0%NO TOTAL ASBESTOS OTHER FIBROUS NON-FffiROUS TOTAL PERCENTAGE IDENTIFIED MATERIALS NO ND ND NO 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 0.0 100.0 100.0 THE SAMPLES WERE RECEIVED IN ACCEPT ABLE CONDITION.THIS TEST REPORT RELA TES ONLY TO THE ITEMS TESTED.THIS REPORT MAY NOT BE REPRODUCED EXCEPT INFULL, WlTHOUT THE WRITTEN APPROVAL OF THE LABORATORY. 12421 W.49th Avenue,Unit #6 Wheat Ridge,CO 80033 OCM Project No.:ADAT 963 Client Job No.:165 FOREST RD. Bulk Sample Analysis Page _j_of t.J BULK SAMPLE ANALYSIS PROCEDURES: DCM Science Laboratory,Inc.analyzes bulk asbestos samples following procedures developed by the McCrone Research Institute and in compliance with guidelines established by the Environmental Protection Agency (EPA-600/M4-82-020,1982 and EPA-600/R-93/116,July,1993). Bulk samples are prepared for analysis using a 10X-80X stereo microscope in a hepa filter hood which provides a contamination-free environment.The sample is then analyzed by polarized light microscopy (PLM) at 100X.When the sample consists of more than one layer,each layer is prepared and analyzed separately. Fiber and matrix materials are identified by the characterization of optical properties including color and pleochroism,form,cleavage,relief,birefringence,extinction,orientation,twinning,interference figure and other distinguishing features.Dispersion staining is also used to further aid in mineral identification.All percentages of asbestos,other fibers and non-fibrous constituents are calculated from the values obtained from analyses using the stereo and PLM microscopes.In-house and NIST standards as well as a chart prepared by R.D. Terry and G.v.Chilinger for ''The Journal of Sedimentary Petrology",(Volume 24,pp.229-234,1955)provide a guide for estimating percentages.All samples are archived for six months unless other arrangements are made by the client. ACCREDITATION: DCMSL is accredited by NVLAP (since April 1,1989).Our NVLAP Lab Code is 101258-0.DCMSL complies with NVLAP requirements unless otherwise noted. ENDORSEMENT: The results of this analysis must not be used by the client to claim endorsement by NVLAP or any agency of the U.S.Government. The analysis was performed by : Ron Schott,Analyst Ron Schott Laboratory Director Date ~W~£~ NVLAP Lab Code 101258-0