HomeMy WebLinkAboutB15-0310_A.00_1444237980.pdfPROJECT:
B O L W I N E R O O M
DRAWN BY:
REVISIONS:
SOLARIS
141 EAST MEADOW DRIVE, SUITE 113
VAIL, COLORADO
DATE: 08.18.15
BOL-15
WMC
A.00
BOL WINE ROOM
SOLARIS, 141 EAST MEADOW DRIVE, SUITE 113. VAIL, COLORADO
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO
BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY
CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH
WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN
THESE PARTICULAR AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD
COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND
ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF
WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS
INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS,
TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND
FALSE BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR
DOOR TYPES.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE
FOR WINDOW TYPES.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING
FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM
DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE
CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL
IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO
ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL
APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS.
COMPLIANCE WITH ALL CURRENT CODES IS MANDATORY. THE CONSTRUCTION
DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT
CODES INCLUDING THE INTERNATIONAL BUILDING CODE AND ALL LOCAL AND
REGIONAL CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE
AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING,
NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING,
OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL
INTEGRITY OF THE CONSTRUCTION.
12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT
THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO
BEGINNING ANY SITE WORK.
13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF
& DECK SURFACES MUST BE MAINTAINED REASONABLY FREE OF ICE & SNOW TO
ENSURE MINIMAL PROBLEMS WITH THESE SURFACES.
14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S
WRITTEN APPROVAL.
15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL
CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS
TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN
THE RECOGNIZED STANDARDS OF THE INDUSTRY.
16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE
SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL
EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND
VEGETATION IMPACTS TO THE SITE.
18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND
TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF
EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH
THE NON-DISTURBED LANDSCAPE.
19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER.
20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE
CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN
IS FOR LAYOUT; IN CASE OF ANY DISCREPANCIES VERIFY WITH ARCHITECT.
ARCHITECTURAL
A.00 COVER SHEET
A.01 FLOOR PLAN
A.02 ELEVATION
A.03 ELEVATION & SECTION
A.04 FIRE RATED PENETRATION DETAIL
ELECTRICAL
E1.0 SPECIFICATIONS AND NOTES
E1.1PANEL SCHEDULES
E2.0 ELECTRICAL PLAN
CODE:
2012 INTERNATIONAL BUILDING CODE
ZONING:
SDD #39
COMMERCIAL SERVICE CENTER
UNDERLYING
OCCUPANCY CLASSIFICATION:
GROUP A-2
CONSTRUCTION CLASSIFICATION:
TYPE I-A
EIGHT STORY STEEL FRAMED BUILDING,
FULLY SPRINKLED
PROJECT SQUARE FOOTAGE:
75sf WINE ROOM IN EXISTING 12,600sf
RESTAURANT, BAR, BOWLING ALLEY
PROJECT LOCATION:
141 E. MEADO DR. #113
VAIL, COLORADO
81657
N
PROJECT SUMMARY: DRAWING INDEX:
PROJECT TEAM:
ARCHITECT
CURRENT ARCHITECTS
PO BOX 9253
VAIL, CO 81657
WWW.CURRENTARCHITECTS.COM
PHONE: 970-331-6345
CONTACT: MICHAEL CURRENT
ELECTRICAL ENGINEER
ARCHITECTURAL ENGINEERING CONSULTANTS
PO BOX 8489
AVON, CO 8162O
WWW.AEC-VAIL.COM
PHONE: 970.748.8520
CONTACT: STAN HUMPHREYS
10/07/15