Loading...
HomeMy WebLinkAboutB15-0449_Pella SGD cut sheet_1446677400.pdfINSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD SLIDING PATIO DOOR PUERTA CORREDERA PARA PATIO Installation Instructions for Typical Wood Frame Construction.These instructions were developed and tested for use with typical wood frame wall construction in a wall system designed to manage water. These instructions are not to be used with any other construction method. Installation instructions for use with other construction methods, multiple units or bow and bay windows, may be obtained from Pella Corporation or a local Pella retailer, or by visiting http://www.pella.com. Building designs, construction methods, building materials, and site conditions unique to your project may require an installation method different from these instructions and additional care. Determining the appropriate installation method is the responsibility of you, your architect, or construction professional. Sill Flashing Tape #2 Sill Flashing Tape #1 Water Resistive Barrier Sheathing Framing Nailing Fin Sill Support TopFlashingTape FinCorner Door Top Door Bottom SideFlashingTape Interlocker SideFlashingTape CornerFlashingTape CornerFlashingTape Part Number: 801W0104©2012 Pella Corporation Always read the Pella® Limited Warranty before purchasing or installing Pella products. By installing this product, you are acknowledging that this Limited Warranty is part of the terms of the sale. Failure to comply with all Pella installation and maintenance instructions may void your Pella product warranty. See Limited Warranty for complete details at http://warranty.pella.com. D. Fold the water resistive barrier (1D). Fold side flaps into the opening and staple to inside wall. Fold top flap up and temporarily fasten with flashing tape. YOU WILL NEED TO SUPPLY: TOOLS REQUIRED: Ř&HGDURU,PSHUYLRXVVKLPVVSDFHUV WR ŘJDOYDQL]HGURRŵQJQDLOV OE Ř&ORVHGFHOOIRDPEDFNHUURGVHDODQWEDFNHU  WRIW Ř3HOODp6PDUW)ODVKŠIRLOEDFNHGEXW\OZLQGRZDQG door flashing tape or equivalent Ř3HOOD:LQGRZDQG'RRU,QVWDOODWLRQ6HDODQWRU equivalent high quality, multi-purpose sealant WRWXEHVSHUGRRU Ř/RZ([SDQVLRQORZSUHVVXUHSRO\XUHWKDQH insulating window and door foam sealant. DO 127XVHKLJKSUHVVXUHRUODWH[IRDPV Ř3HOODDOXPLQXPVLOOVXSSRUWRU[ZRRG blocking Ř,QWHULRUWULPDQGRUMDPEH[WHQVLRQV WRIW Ř$OXPLQXPKHDGŶDVKLQJ Ř7DSHPHDVXUH Ř /HYHO Ř6TXDUH Ř+DPPHU Ř6WDSOHU Ř6FLVVRUVRUXWLOLW\NQLIH Ř6FUHZGULYHUV 3KLOOLSVZLWKVKDIWDQGVPDOO ŶDWEODGH Ř'ULOO Ř6HDODQWJXQ SEALANTSEALANT REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT. $&RQŵUPWKHRSHQLQJLVSOXPEDQGOHYHO Note: It is critical the bottom is level. Interior 1B Interio r 1AB. Confirm the door will fit the opening. Measure DOOIRXUVLGHVRIWKHRSHQLQJWRPDNHVXUHLWLVODUJHUWKDQWKHGRRULQZLGWKDQGODUJHULQheight. Measure the width at the top, bottom, and center. Measure the height at the far left side, the far right side, and in the center. Note: 1-1/2" or more of solid wood blocking is required around the perimeter of the opening. Fix any problems with the rough opening before proceeding. Exterior 1D 1C 4th cut: Make a 6” cut up from each top corner at a 45°angle to allow the water resistive barrier to be lapped over the fin at the head of the door. 1st cut 2ndcut 3rd cut Water Resistive Barrier C. Cut the water resistive barrier &  1 ROUGH OPENING PREPARATION 1A 1B 1D 1C A. Remove the plastic wrap and cardboard packaging from the door. Note: If screens, grilles or hardware are removed from the door at this time, label them and store them in a protected area. 2D 1H 1" 1G 1F 1" 1/2" 1/2" 6" 1E (Apply sill flashing tape #1. Cut a piece of flashing tape ORQJHUWKDQWKHRSHQLQJZLGWK$SSO\DWWKHERWWRPRIWKHRSHQLQJDVVKRZQ ( VRLWRYHUKDQJVWRWKHH[WHULRU Note: The tape is cut 12" longer than the width of the opening so that it will extend up each side approximately 6". F. Tab the sill flashing tape and fold.&XWZLGHWDEVDWHDFKFRUQHU IURPHDFKVLGHRIFRUQHU  ) )ROGWDSHWRWKHH[WHULRUDQGSUHVVŵUPO\WRDGKHUHLWWRWKHZDWHUresistive barrier. G. Apply sill flashing tape #2. Cut a piece of flashing tape ORQJHUWKDQWKHRSHQLQJZLGWK$SSO\DWWKHERWWRPRYHUODSSLQJWDSHE\DWOHDVW'RQRWDOORZWKHWDSHWRH[WHQGSDVWWKHLQWHULRUIDFHRIWKHIUDPLQJ *  Note: The flashing tape may not fully cover the framing members. +Attach the aluminum sill support or wood blocking to the H[WHULRURIWKHER[SODWHWRVXSSRUWWKHHGJHRIWKHGRRUVLOOPlace the sill support flush with the subfloor. B. Remove the shipping spacers. Carefully slide the movable panel halfway open and remove the spacers from both the top and bottom of the movable panel. TWO OR MORE PEOPLE WILL BE REQUIRED FOR THE FOLLOWING STEPS. C. Remove the venting panel by lifting it out of the lower track and tilting the bottom of the panel away from the door frame. Then, lower the panel out of the top track. Carefully set the panel aside. Note: Assemble the OXXO frame per the instructions included with the door splice kit. D. Fold out installation fin to 90º. Be careful not to UHPRYHRUWHDUWKHŵQFRUQHUV Note: If the fin is not at 90°, the door will not line up correctly on the interior. 1 ROUGH OPENING PREPARATION (CONTINUED) 2 PREPARE THE DOOR FOR INSTALLATION ( 1F 1G + 2D A. Place three 3/8" beads of sealant.7KHŵUVWEHDGVKRXOGEHDSSUR[LPDWHO\IURPWKHH[WHULRURIWKHURXJKRSHQLQJWKHVHFRQGLQIURPWKHŵUVWEHDGof sealant. Place a third bead of sealant in the groove RIWKHVLOOVXSSRUWRUIURPWKHH[WHULRUHGJHRIWKHwood blocking. TWO OR MORE PEOPLE WILL BE REQUIRED FOR THE FOLLOWING STEPS. 3A 120304050 6 0 7 0 2 3 INCHESmm 3D Interior 3C shim 3E shim 3E 3F C. Plumb and square door. Insert shims, as necessary, between the door and the sides of the URXJKRSHQLQJVWDUWLQJXSIURPWKHERWWRPRIWKHGRRU.HHSVKLPVEDFNIURPWKHLQWHULRUface of the door. Exterio r 3B 3B B. Insert the doorIURPWKHH[WHULRURIWKHEXLOGLQJDO NOT slide the bottom of the door into the opening. Sliding will damage the sealant lines. Place the bottom of the door at the bottom of the opening, then tilt the top into position. Center the door between the sides of the opening to allow equal clearance for shimming and insert RQHURRŵQJQDLOLQWKHŵUVWKROHIURPWKHFRUQHURQHDFKHQGRIWKHWRSQDLOLQJŵQ7KHVHDUHXVHGWRhold the door in place while shimming it plumb and square. Note: DO NOT over shim. D. Check the interior reveal. Make sure the measurement from the interior face of the door to the interior face of the wall is equal at several points around the door. Note: If the dimensions are not equal, check to make sure the fins are folded out to 90° at all points. ( 6HFXUHWKHIUDPH,QVHUWDZLGHVKLPEHKLQGWKHSLORWKROHDWWKHORFNVWULNH V ,QVHUWD[VFUHZ LQFOXGHGLQWKHSDQHOUHWDLQHUDQGVFUHZSDFNDJH LQWRWKHpilot hole making sure it passes through the shim and into the rough opening. Note: The weather strip must be pushed aside to reveal the pilot hole. Be careful not to damage the weather strip. Architect Series® and Designer Series® have 2 lock strikes, ProLine® has one lock strike. F. Fasten the door to openingE\GULYLQJJDOYDQL]HGURRŵQJQDLOVLQWRHDFKSUHSXQFKHGKROHLQWKHQDLOLQJŵQ Note: Make sure the fin corner is lying as flat as possible. ProLine Doors - Proceed to Step 4. 3 SETTING AND FASTENING THE DOOR 3A 3B 3B 3C 3D (( 3F A. Apply side flashing tape.&XWWZRSLHFHVRIŶDVKLQJWDSHORQJHUWKDQWKHIUDPHKHLJKWRIWKHGRRU$SSO\RQHSLHFHRQWRWKHIUDPHFODGGLQJRYHUWKHQDLOLQJŵQDQGRQWRWKHZDWHUUHVLVWLYHEDUULHURQHDFKVLGH7KHWDSHVKRXOGH[WHQGDERYHWKHWRSRIWKHGRRUDQGEHORZWKHERWWRPRIWKHGRRU3UHVVWKHWDSHGRZQŵUPO\ZKLOHIROGLQJGRZQWKHH[FHVVWDSHDWWKHWRSDQGERWWRPRIWKHGRRU Interior Exterior Fixed Panel Threshold 3H 3G Architect Series and Designer Series G. Architect Series and Designer Series:$SSO\VHDODQWDQGLQVHUWD[SDQKHDGVFUHZ SURYLGHG LQWRHDFKKROHLQWKHERWWRPRIWKHGRRUIUDPH VKRZQDERYHLQJROG $QRWKHURSWLRQLVWRXVH[FRQFUHWHVFUHZVDrill pilot holes per manufacturers instructions. Note: The flashing tape must be applied approximately 1/2" onto the frame cladding at the jambs and head. Pre-folding the tape at 1/2" before removing the paper backing will make it easier to apply the tape correctly. If the siding is less than 1/2" thick, adjust the dimension of the fold so the exterior sealant line will cover the exterior edge of the tape. B. Apply top flashing tape. Cut a piece of flashing tape ORQJHQRXJKWRJRDFURVVWKHWRSRIWKHGRRUDQGH[WHQGDWOHDVWSDVWWKHVLGHŶDVKLQJWDSHRQERWKVLGHV$SSO\WKHWDSHRQWRWKHIUDPHFODGGLQJRYHUWKHWRSQDLOLQJŵQDVVKRZQ)ROGWKHRYHUODSSLQJWDSHGRZQDQGSUHVVDOOWDSHGRZQŵUPO\ Note: The top flashing tape must overlap the side flashing tape to prevent water from getting behind it. +Architect Series and Designer Series: Position and secure the panel retainer by drilling pilot holes through the remaining holes in the retainer into the sill support or wood blocking, then apply sealant to the holes and insert a screw into HDFKKROHDVVSHFLŵHGEHORZ Aluminum sill support:SLORWKROHV[ŶDWKHDGWKUHDGFXWWLQJVFUHZV SURYLGHG  Wood blocking:SLORWKROHV[ŶDWKHDGZRRGVFUHZV SURYLGHG  Masonry floor:[FRQFUHWHVFUHZ3LORWGULOOSHUVFUHZPDQXIDFWXUHUőVrecommendations. I. Remove the factory installed screws from the retainer and repeat the process. J. Architect Series and Designer Series: Drill DFOHDUDQFHKROHDWHDFKLQGHQWDWLRQLQWKHH[WUXVLRQDWWKHWRS KHDG RIWKHGRRUframe into the rough opening, stopping when the drill is through the door frame. Apply sealant to each hole, then insert a [SDQKHDGVFUHZLQWRHDFKKROH 3 SETTING AND FASTENING THE DOOR (CONTINUED) 4 INTEGRATING THE DOOR TO THE WATER RESISTIVE BARRIER 3G + Sealant goes here 3/16" 3J Exterior 4A 1" 4B 4A 4B Head flashing Flashing tape Sealant Nailing Fin Flashing Tape Head flashing Wall Note: Steps C-E may be completed for any Pella Door (some codes require head flashing). Pella requires head flashing on OXXO (4 panel) sliding doors. 4 INTEGRATING THE DOOR TO THE WATER RESISTIVE BARRIER (CONTINUED) C. Apply sealant at the point where the door frame cladding contacts the QDLOLQJŵQDQGDWHDFKHQGof the frame. Exterior 4D 4C F. Fold down top flap of water resistive barrier (4C). G. Apply flashing tape to diagonal cuts. Cut pieces of ŶDVKLQJWDSHDWOHDVWORQJHUWKDQWKHGLDJRQDOFXWVin the water resistive barrier. Apply the tape covering the entire diagonal cut in the water resistive barrier at both upper corners of the door. Note: Be sure to overlap the top corners (4D). 4F 4G 4C 4D ( D. Install the head flashing. (Apply a piece of flashing tape over the head flashing as shown. Caution: Ensure use of low pressure polyurethane window and door insulating foams and strictly follow the foam manufacturer’s recommendations for application. Use of high pressure foams or improper application of the foam may cause the door frame to bow and hinder operation. TWO OR MORE PEOPLE WILL BE REQUIRED FOR THE FOLLOWING STEPS. A. Insert door panel.)URPWKHH[WHULRURIWKHEXLOGLQJWLOWthe top of the panel toward the door frame and insert the top of the door panel into the top track. Move the bottom of the panel toward the door frame until it is vertical. Gently set the panel down into the bottom track. ProLine only: Install bumpers and the panel retainer. )ROORZWKHLQVWUXFWLRQVLQFOXGHGLQWKHKDUGZDUHER[ Note: Be careful not to pinch your fingers between the two panels. DO NOT close the sliding panel until you have installed the hardware. The door may lock when closed. 5A Interior 6A B. Install the handles and panel retainer. Follow the instructions included in the KDUGZDUHER[,IWKHSDQHOLVQRWVTXDUHWRWKHGRRUIUDPHDGMXVWWKHERWWRPUROOHUVE\UHPRYLQJWKHDGMXVWLQJKROHFRYHUDQGLQVHUWLQJDQORQJPhillips screwdriver into the hole. Turn clockwise to raise the panel and counter-FORFNZLVHWRORZHUWKHSDQHO)ROORZWKHLQVWUXFWLRQVLQFOXGHGLQWKHKDQGOHER[IRUŵQDODGMXVWPHQWV C. Install screen. Instructions for installing the screen are found in the screen door package. A. Apply insulating foam sealant. From the interior, LQVHUWWKHQR]]OHRIWKHDSSOLFDWRUDSSUR[LPDWHO\GHHSLQWRWKHVSDFHEHWZHHQWKHGRRUDQGWKHURXJKRSHQLQJDQGDSSO\DGHHSEHDGRIIRDP7KLVZLOODOORZURRPIRUH[SDQVLRQRIWKHIRDPDQGZLOOPLQLPL]HVTXHH]HRXW$SSO\VHDODQWDFURVVinterior surface of shims to create a continuous seal. )RUGRRUVZLWKMDPEH[WHQVLRQVLQVWDOOHGHQVXUHthe foam is placed between the door frame and the URXJKRSHQLQJQRWEHWZHHQWKHMDPEH[WHQVLRQDQGWKHURXJKRSHQLQJ)ROORZIRDPPDQXIDFWXUHU Vinstructions. Note: It may be necessary to squeeze the end of the tube with pliers to be able to insert into the space between the door frame and the rough opening. DO NOT completely fill the space from the back of the fin to the interior face of the opening. B. Check the door operation by opening and closing the door. Note: If the door does not operate correctly, check to make sure it is still plumb, level, square and that the sides are not bowed. If adjustments are required, remove the foam with a serrated knife. Adjust the shims, and reapply the insulating foam sealant. $ 5 REINSTALL THE SLIDING PANEL 6 INTERIOR SEAL $ When applying siding, brick veneer or other exterior finish material, leave adequate space between the door frame and the material for sealant. Refer to the illustration corresponding to your finish material. Note: The sealant details shown are standard recommendations from the sealant industry. Contact your sealant supplier for recommendations and instructions for these and any other applications. A. Insert closed cell foam backer rod into the space DURXQGWKHGRRUVRWKHUHLVDSSUR[LPDWHO\WRFOHDUDQFHEHWZHHQWKHEDFNHUURGDQGWKHH[WHULRUIDFHRIWKHGRRU Note: Backer rod adds shape and depth for the sealant line. B. Apply a bead of high quality exterior grade sealant to the entire perimeter of the door. At each end of the bottom of the door, insert sealant into the spaces between the bottom of the door and the sill support and connect it to the perimeter sealant. C. Shape, tool and clean excess sealant. When ŵQLVKHGWKHVHDODQWVKRXOGEHWKHVKDSHRIDQhourglass. Note: This method creates a more flexible sealant line capable of expanding and contracting. D. Remove plastic guards at the base of the door once construction is complete. 7B 7A 7 SEALING THE DOOR TO THE EXTERIOR WALL CLADDING 7A 7B VINYL/STEEL SIDING 3/8" Clearance Backer Rod and Sealant typical Insulating Foam Perimeter Sealant must extend to room side of Accessory Groove. Accessory Groove 3/8" Min. 3/8" WOOD SIDING 1/8" Clearance Sealant typical Insulating Foam Accessory Groove 1/8" WOOD SIDING WITH TRIM 3/8" Clearance Insulating Foam Perimeter Sealant must extend to room side of Accessory Groove. Accessory Groove Sealant typical 3/8" Min. 3/8" BRICK VENEER 3/8" Clearance Backer Rod and Sealant typical Perimeter Sealant must extend to room side of Accessory Groove. Accessory Groove Insulating Foam 3/8" Min. 3/8" Head Flashing Head Flashing Head Flashing Head Flashing Head Flashing EXTERIOR FINISH7KHH[WHULRUIUDPHDQGVDVKDUHSURWHFWHGE\DOXPLQXPFODGGLQJZLWKRXUWRXJK(QGXUD&ODGpRU(QGXUD&ODG3OXVEDNHGRQIDFWRU\ŵQLVKWKDWQHHGVQRSDLQWLQJ&OHDQWKLVVXUIDFHZLWKPLOGsoap and water. Stubborn stains and deposits may be removed with mineral spirits. DO NOT use abrasives. DO NOT scrape or use tools that might damage the surface. 8VHRILQDSSURSULDWHŵQLVKHVVROYHQWVEULFNZDVKRUFOHDQLQJFKHPLFDOVZLOOFDXVHDGYHUVHreactions with window and door materials and voids the Limited Warranty. CARE AND MAINTENANCE&DUHDQGPDLQWHQDQFHLQIRUPDWLRQLVDYDLODEOHLQWKH3HOOD2ZQHUőV0DQXDO<RXFDQREWDLQDQRZQHUőVPDQXDOE\FRQWDFWLQJ\RXUORFDO3HOODUHWDLOHU7KLVLQIRUPDWLRQLVDOVRDYDLODEOHRQwww.pella.com. INTERIOR FINISHING ,ISURGXFWVFDQQRWEHŵQLVKHGLPPHGLDWHO\FRYHUZLWKFOHDUSODVWLFWRSURWHFWIURPGLUWGDPDJH DQGPRLVWXUH5HPRYHDQ\FRQVWUXFWLRQUHVLGXHEHIRUHŵQLVKLQJ6DQGDOOZRRGVXUIDFHVOLJKWO\ ZLWKJULWRUŵQHUVDQGSDSHU'2127XVHVWHHOZRRO%(&$5()8/127726&5$7&+7+( GLASS. Remove sanding dust. 3HOODSURGXFWVPXVWEHŵQLVKHGSHUWKHEHORZLQVWUXFWLRQVIDLOXUHWRIROORZWKHVHLQVWUXFWLRQVYRLGV the Limited Warranty. Ř2QFDVHPHQWDQGDZQLQJVLWLVRSWLRQDOWRSDLQWVWDLQRUŵQLVKWKHYHUWLFDODQGKRUL]RQWDOVDVK edges. Ř2QVLQJOHKXQJDQGGRXEOHKXQJGRQRWSDLQWVWDLQRUŵQLVKWKHYHUWLFDOVDVKHGJHVDQ\ŵQLVK RQWKHYHUWLFDOVDVKHGJHVPD\FDXVHWKHVDVKWRVWLFNLWLVRSWLRQDOWRSDLQWVWDLQRUŵQLVKWKH KRUL]RQWDOVDVKHGJHV Ř2QSDWLRGRRUVLWLVRSWLRQDOWRSDLQWVWDLQRUŵQLVKWKHYHUWLFDODQGKRUL]RQWDOSDQHOHGJHV Note: To maintain proper product performance do not paint, finish or remove the weather- stripping, mohair dust pads, gaskets or vinyl parts. Air and water leakage will result if these parts are removed. After finishing, allow venting windows and doors to dry completely before closing them. 3HOOD&RUSRUDWLRQLVQRWUHVSRQVLEOHIRULQWHULRUSDLQWDQGVWDLQŵQLVKLPSHUIHFWLRQVIRUDQ\SURGXFW WKDWLVQRWIDFWRU\DSSOLHGE\3HOOD&RUSRUDWLRQ8VHRILQDSSURSULDWHŵQLVKHVVROYHQWVEULFNZDVK or cleaning chemicals will cause adverse reactions with window and door materials and voids the /LPLWHG:DUUDQW\)RUDGGLWLRQDOLQIRUPDWLRQRQŵQLVKLQJVHHWKH3HOOD2ZQHUőV0DQXDORUJRWR www.pella.com.. IMPORTANT NOTICE %HFDXVHDOOFRQVWUXFWLRQPXVWDQWLFLSDWHVRPHZDWHULQŵOWUDWLRQLWLVLPSRUWDQWWKDWWKHZDOOV\VWHP be designed and constructed to properly manage moisture. Pella Corporation is not responsible IRUFODLPVRUGDPDJHVFDXVHGE\DQWLFLSDWHGDQGXQDQWLFLSDWHGZDWHULQŵOWUDWLRQGHŵFLHQFLHVLQ EXLOGLQJGHVLJQFRQVWUXFWLRQDQGPDLQWHQDQFHIDLOXUHWRLQVWDOO3HOODSURGXFWVLQDFFRUGDQFHZLWK 3HOODőVLQVWDOODWLRQLQVWUXFWLRQVRUWKHXVHRI3HOODSURGXFWVLQZDOOV\VWHPVZKLFKGRQRWDOORZIRU proper management of moisture within the wall systems. The determination of the suitability of all building components, including the use of Pella products, as well as the design and installation of flashing and sealing systems are the responsibility of the Buyer or User, the architect, contractor, installer, or other construction professional and are not the responsibility of Pella. Pella products should not be used in barrier wall systems which do not allow for proper PDQDJHPHQWRIPRLVWXUHZLWKLQWKHZDOOV\VWHPVVXFKDVEDUULHU([WHULRU,QVXODWLRQDQG)LQLVK 6\VWHPV (,)6  DOVRNQRZQDVV\QWKHWLFVWXFFR RURWKHUQRQZDWHUPDQDJHGV\VWHPV([FHSW LQWKHVWDWHVRI&DOLIRUQLD1HZ0H[LFR$UL]RQD1HYDGD8WDKDQG&RORUDGR3HOODPDNHVQR warranty of any kind on and assumes no responsibility for Pella windows and doors installed in barrier wall systems. In the states listed above, the installation of Pella Products in barrier wall or VLPLODUV\VWHPVPXVWEHLQDFFRUGDQFHZLWK3HOODőVLQVWDOODWLRQLQVWUXFWLRQV 3URGXFWPRGLŵFDWLRQVWKDWDUHQRWDSSURYHGE\3HOOD&RUSRUDWLRQZLOOYRLGWKH/LPLWHG:DUUDQW\