Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B15-0469_A0.0_1452118080.pdf
CONCRETE CONCRETE MASONRY STONE FRAME WALL TILE STEEL ALUMINUM OR SHEET METAL BATT INSULATION GYP. WALL BOARD/ STUCCO/ PLASTER PLYWOOD SOIL/ COMPACTED FILL ROCK/ NON-COMPACTED FILL / GRAVEL SAND / GWB/ PLASTER FINISHED WOOD ROUGH FRAMING OR ROUGH SAWN TRIM WOOD BLOCKING GLU-LAM WOOD PARTICLE BOARD OR WOOD FIBER BOARD RIGID INSULATION CARPET ROOM NAMEROOM NAMEROOM NAMEROOM NAME 101 FLOOR FINISH WALL SECTION CUT BUILDING SECTION CUT SECTION NO. SHEET NO. SECTION NO. SHEET NO. SECTION NO. SHEET NO. DETAIL CUT GRID REFERENCE LINE ROOM NUMBER 101b DOOR MARK SPOT ELEVATION DRAWING REVISION INTERIOR ELEVATION WINDOW MARK DETAIL A4.1 1 EXTERIOR ELEVATION A9.1 2 3 4 1 1i SIM SIM SIM SIM 000 0 228 Midland Avenue | PO Box 529 | Basalt, Colorado 81621 970-927-4925 | www.ccyarchitects.com DATE: DRAWN BY: CHECKED BY: PROJECT NUMBER: ISSUE: HISTORY: SCALE: © COTTLE CARR YAW ARCHITECTS, LTD.© COTTLE CARR YAW ARCHITECTS, LTD.© COTTLE CARR YAW ARCHITECTS, LTD. © COTTLE CARR YAW ARCHITECTS, LTD. DRB SUBMITTAL 10/10/2015 DRB RESPONSE 10/28/2015 PRICING 11/04/2015 PERMIT 12/04/2015 As indicated NM 15027 COVER SHEET A-0.0 BILLINGSLEY REMODEL PERMIT SET 12/04/2015 1170 PTARMAGIN RD., VAIL COLORADO AK ARCHITECTURAL SHEET INDEX A-1.0 EXISTING SITE & PROPOSED PARKING PLAN A-1.1 LANDSCAPE PLAN A-1.2 EXISTING LOWER LEVEL & SCOPE OF WORK A-1.3 EXISTING MAIN LEVEL (NOT IN SCOPE) A-1.4 EXISTING UPPER LEVEL (NOT IN SCOPE) A-1.5 PROPOSED LOWER LEVEL PLANS A-1.6 PROPOSED RCP & ROOF PLANS A-2.1 PROPOSED EXT. ELEVATION A-2.2 PROPOSED EXT. ELEVATION A-3.1 BUILDING SECTIONS A-4.1 PROPOSED INT. ELEVATIONS - BATH ROOM A-4.2 PROPOSED INT. ELEVATIONS - BUNK ROOM A-5.0 WALL SECTIONS & ASSEMBLIES A-9.1 PERSPECTIVE VIEWS GENERAL NOTES ABBREVIATIONS PROJECT DIRECTORY MATERIAL LEGEND SYMBOL LEGEND OWNER ARCHITECT BUILDER LUCY BILLINGSLEY 1170 PTARMIGIN RD VAIL, CO 81657 214-270-2222 CONTACT: LUCY BILLINGSLEY CCY ARCHITECTS, LTD. 228 MIDLAND AVENUE P.O. BOX 529 BASALT, CO. 81621 970-927-4925 FAX 970-927-8578 CONTACT: NICK MISCIONE SHAEFFER HYDE CONSTRUCTION P.O. BOX 373 VAIL, CO 81658 970-790-1541 CONTACT: JEFF KISSANE K. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE BIDDING PROCESS. O. ALL DIMENSIONS ON STRUCTURAL DRAWINGS TO BE CHECKED AGAINST ARCHITECTURAL DRAWINGS. NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. A. THE AIA DOCUMENT 201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", LATEST EDITION, ARE HEREBY MADE A PART OF THESE CONTRACT DOCUMENTS. COPIES ARE ON FILE AND ARE AVAILABLE FOR INSPECTION AT THE OFFICES OF THE ARCHITECT. B. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT, THE GENERAL NOTES, THE SPECIFICATION/ DETAIL BOOK, AND THE DRAWINGS, WHICH ARE COOPERATIVE AND CONTINUOUS. WORK INDICATED OR REASONABLY IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. C. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, AND SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF CRAFTSMANSHIP BY JOURNEYMEN OF THE APPROPRIATE TRADES. D. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED BY EXISTING CONDITIONS OR WHERE NEGLECTED IN THE DOCUMENTS. E. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED, OR CALLED OUT BY TRADE NAME, IN THESE DOCUMENTS SHALL BE PRESENTED TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN REQUIRED BY THE ARCHITECT, AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO THE REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH WORK WHICH CONFORMS AT THE CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR REVIEW THROUGH THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND SUBMITTALS TO BE MADE IN ADEQUATE TIME AS NOT TO DELAY WORK IN PROGRESS. F. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER REVIEW WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITECT BEFORE WORK IS BEGUN, AND WORK SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN PARAGRAPH "E" ABOVE. G. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE INTERNATIONAL BUILDING CODE / INTERNATIONAL RESIDENTIONAL CODE OR ANY LOCAL CODE OR ORDINANCE. H. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED COMPLETED TO THE OWNER. I. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONAL DISCREPANCIES WITH THE ARCHITECT. J. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS. T TREAD T&B TOP AND BOTTOM T&G TOUNGE AND GROOVE T.O. TOP OF TEL TELEPHONE TEMP TEMPERED THK THICK TPH TOILET PAPER HOLDER TS TUBE STEEL TV TELEVISION TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE UBC UNIFORM BUILDING CODE UG UNDERGROUND UNFIN UNFINISHED USG UNITED STATES GAUGE V.I.F. VERIFY IN FIELD VAR VARIABLE VENT VENTILATE(D) VG VERTICAL GRAIN WD WOOD HT HEIGHT HVAC HEATING VENTILATING AND COOLING HWY HIGHWAY IBC INTERNATIONAL BUILDING CODE ICP INTERGRATED COLOR PLASTER ID INSIDE DIAMETER IE THAT IS INT INTERIOR INT INSULATION IRC INTERNATIONAL RESIDENTIAL CODE JT JOINT LAM LAMINATE LAV LAVATORY MAX MAXIMUM MC MEDICINE CABINET MECH MECHANICAL MFG MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTL MATERIAL NA NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OPG OPENING OPH OPPOSITE HAND OPP OPPOSITE PERF PERFORATED PFSM PREFINISHED SHEET METAL PL PLATE PLY PLYWOOD PROD PRODUCT PROJ PROJECT PROP PROPERTY R RADIUS OR RISER REF REFER REFR REFRIGERATOR REINF REINFORCE REQ'D REQUIRED RHSM ROUND HEAD SHEET METAL RM ROOM RO ROUGH OPENING RW ROOF WINDOW S.T.D. SLOPE TO DRAIN SAN SANITARY SECT SECTION SEW SEWER SHLV SHEET SHT SHELVES SIM SIMILAR SPEC SPECIFICATION SQ SQUARE STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STRUCT STRUCTURE(AL) SUB SUBSTITUTE SUPPL SUPPLEMENT(AL) SUSP SUSPEND(ED) AAD ATTIC ACCESS DOOR ADD ADDENDUM ADJ ADJACENT AFF ABOVE FINISHED FLOOR AGG AGGREGATE ALT ALTERNATIVE AOR AREA OF REFUGE ARCH ARCHITECTURAL ASS'Y ASSEMBLY B.O. BOTTOM OF BD BOARD BET BETWEEN BLDG BUIDLING BM BEAM BRG BEARING BS BOTH SIDES CAB CABINET CER CERAMIC CJ CONSTRUCTION JOINT CL CENTERLINE CLOS CLOSET CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS DET DETAIL DIA DIAMETER DIM DIMENSION DN DOWN DP DAMPPROOFING DR DRAIN DS DOWNSPOUT DW DISHWASHER DWG DRAWING EA EACH EJ EXPANSION JOINT EL ELEVATION EQ EQUAL EXIST EXISTING EXT EXTERIOR F.F. FINISH FLOOR FD FLOOR DRAIN FDN FOUNDATION FE CABT FIRE EXTINGUISHER FIN FINISH FL FLOOR FOC FACE OF CONCRETE FOS FACE OF STUD FP FIREPROOF FTG FOOTING GA GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GLB GLU-LAM BEAM GR GRADE GWB GYPSUM WALLBOARD GYP GYPSUM H.T. HEAVY TIMBER HD HEAD HDW HARDWARE HOR HORIZONTAL SHEET INDEX STRUCTURAL ENGINEER NAME/ COMPANY NAME KL&A STRUCTURAL ENGINEERS 215 N. 12TH STREET, UNIT E, CARBONDALE, CO 81621 970-927-5174 CONTACT: DAN DOHERTY 1170 PTARMAGIN ROAD REMODEL, VAIL COLORADO PERMIT SET S1.1 GENERAL NOTES S1.2 GENERAL NOTES & TYP. DETAILS S1.3 TYP. DETAILS S2.1 PLANS & DETAILS STRUCTURAL SHEET INDEX REV. # DATE DESCRIPTION 01/06/16