Loading...
HomeMy WebLinkAboutB15-0469_A1.6_1452118080.pdfA-2.1A-2.1A-2.1 A-2.1 111 1 AAA A A-2.2A-2.2A-2.2A-2.2 111 1 1111 A-4.1A-4.1A-4.1A-4.1 666 6A-4.2A-4.2A-4.2A-4.2 444 4 555 5 333 3 666 6 222 2 444 4 555 5 1 A-3.1 EXISTING MECHANICAL TO REMAIN EXISTING FOYER TO REMAIN RECESSED LIGHTING FIXTURES EXHAUST FAN TO ERV PROPOSED CLERESTORY WINDOWS. NNN N 0' 3' 6' 9' 12' 15' EXISTING WALL TO REMAIN PROPOSED WALL EXISTING WALL TO BE DEMOLISHED GENERAL NOTES: PROVIDE CODE COMPLIANCE POWER IN ADDITION TO LOCATIONS NOTED ON PLANS. BUNK AREAS: PROVIDE OUTLETS @ 6'-0" O.C. CIRCUITS & SWITCHING TO BE VERIFIED IN FIELD. ALL SWITCHES TO BE DIMMABLE. ALL SWITCHES AND OUTLETS TO HAVE SCREWLESS FACEPLATES BY LUTRON OR EQUIVALENT. EXISTING INFORMATION IS FROM THE ORIGINAL DRAWING SET. EXISTING CONDITIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. ANY DISCREPANCIES IN FIELD SHALL BE BROUGHT TO THE ARCHITECT/OWNER FOR REVIEW PRIOR TO COMMENCEMENT OF WORK. PROPOSED CONTINUOUS CEILING TO EXTERIOR. PROPOSED STEEL FASCIA APPROXIMATE LINE OF PROPOSED CEILING BELOW STAIRS, V.I.F. 1 A-5.0 DUPLEX W/ USB X2 SCONCE X2 SCONCE X2 DUPLEX W/ USB X2 DUPLEX W/ USB (1) EXTERIOR RECESSED LIGHT FIXTURE PROPOSED WOOD CEILING TO MATCH EXISTING SPECIES AND STAIN COLOR PROPOSED GYP. CEILING EXISTING CEILING GYP. CEILING TO REMAIN PROPOSED CEILING FAN CENTERED ON EAST WINDOW & NORTH WALL PROPOSED GYP. CEILING VANITY LIGHTING RE.: A4.1 2 A-5.0 SHADE POCKETS PER WALL SECTIONS. PROVIDE FLUSH ACCESS COVERS TO MATCH ADJACENT CEILING. COURSE & GRAIN TO MATCH @ PERPENDICULAR CONDITIONS EXISTING LIGHTING TO REMAIN IN CLOSET CL. CL. A-2.1A-2.1A-2.1A-2.1 111 1 AAA A 111 1 PROPOSED INTEGRAL GUTTER PROPOSED STEEL FASCIA SLOPE 1/4" PER FT. PROPOSED BALLASTED FLAT ROOF PROPOSED STONE FIN WALL BELOW, STONE BOTH SIDES EXISTING EXTERIOR WALL @ MAIN LEVEL EXISTING INTERIOR SPACE @ MAIN LEVEL OUTSIDE FACE OF PROPOSED EXTERIOR WALL BELOW 1 A-5.0 2 A-5.0 DOWNSPOUT TO BE LOCATED BEHIND VENEER. GC TO VERIFY SUB SURFACE ROUGHING RE: WALL SECTIONS FOR T.O. WALL CAP DOWNSPOUT TO BE SURFACE APPLIED TO MATCH EXISTING 228 Midland Avenue | PO Box 529 | Basalt, Colorado 81621 970-927-4925 | www.ccyarchitects.com DATE: DRAWN BY: CHECKED BY: PROJECT NUMBER: ISSUE: HISTORY: SCALE: © COTTLE CARR YAW ARCHITECTS, LTD.© COTTLE CARR YAW ARCHITECTS, LTD.© COTTLE CARR YAW ARCHITECTS, LTD. © COTTLE CARR YAW ARCHITECTS, LTD. DRB SUBMITTAL 10/10/2015 DRB RESPONSE 10/28/2015 PRICING 11/04/2015 PERMIT 12/04/2015 1/4" = 1'-0" Author 15027 PROPOSED RCP & ROOF PLANS A-1.6 BILLINGSLEY REMODEL PERMIT SET 12/04/2015 1170 PTARMAGIN RD., VAIL COLORADO Checker 1/4" = 1'-0" LOWER LEVEL PROPOSED RCPLOWER LEVEL PROPOSED RCPLOWER LEVEL PROPOSED RCPLOWER LEVEL PROPOSED RCP111 1 1/4" = 1'-0" PROPOSED ROOF PLAN @PROPOSED ROOF PLAN @PROPOSED ROOF PLAN @PROPOSED ROOF PLAN @ EXISTING MAIN LEVELEXISTING MAIN LEVELEXISTING MAIN LEVEL EXISTING MAIN LEVEL2222 REV. # DATE DESCRIPTION 01/06/16