Loading...
HomeMy WebLinkAboutB15-0238_A0-02_1438098840.pdfUP E CK 2 DING UCTION 3 2.0 ACK 6" 6" 10" 10" 6" 4" 4" 6"6" 6"5" 4"6" 4" 12" 4" 20 .99 ' 22.4' 25.6' 15.8' 4.8' 5.9' 4.9' 5.9' 24.8' 21.6' 2.0' 18.8' 1.9' 2.1' 10.4' 2.1' 18.0' 0.6' 4.1'13.5' 25.9' 26.2' 3.7' 1.0' 3.3' 14.9' 1.0 '3.6' 1.0' 0.7' 8080 O SW 3 D D D 3 D DD W DN 1854-A 10' UTILITY EASEMENT 9 ' ROOF PEAK ROOF PEAK EL.=EL.=811 6.2EL.=8115.1 2nd FLOOR DECK 2nd FLOOR DECK OVERHANG 2nd FLOOR DE2 LDING TRUCTION17.5' 15.1' 5' 26 26.0' 4.0' 14.0' 10.1' 18.5' 12.6' 17.5' 26.6' 2.0' 2.0' 2.0' 14.0' 2.0' 4.9' 5.0' 22.0' 6.0'2.0' 6" 10" 6"6" 6"5" 4"6" 4" 12" 4" 4.8' 5.9' 5.7' 26.3' 2.0' 18.8' 1.9' 2.1' 10.4' 2.1' 18.0' 4.1'13.5' 3.7' 1.0 '3.3' 14.9' 3.6' LOWER DECK 3" PVC INV 8085.72 TRENCH DRAIN17.3 '15.1' CO DRI F.F. 8088.66 X X F.F. 8088.03 X PEAK 8115.98 LOT 25A LOT 25B 2-STORY WOOD FRAME WITH STUCCO S35°51'12"W 148.12' O S GFI +42 GFI +42 3 3 GRFA OVERVIEW GRFA CLAC FOR HILLSIDE RESIDENTIAL DISTRICT SECTION 12-6A-8B .13 X 5469 = 710.97 SF .46 X10000 = 4600 SF SITE TOTAL SF 20,469 SF, .47 ACRES 46% OF THE FIRST 10,000 SF .38 X 5000 = 1900 SF 38% OF THE SECOND 5,000 SF 13% OF THE THIRD 15,000 SF SITE TOTAL SF 20,469 SF 20,469 X .2 = 4093.8 SF MAX. SITE COVERAGE UNIT B MAX GRFA (40% OF TOTAL GRFA) GRFA UNIT B = 2884.39 SF .6 X 0 = 0 SF 6% OF THE REMAINING 20469 SF 7210.97 SF .6 X 7210.97 SF = 4326.58 SF TOTAL GRFA = PROPOSED GRFA - UNIT A LOWER LEVEL 20'-0" FT FRONT SIDE SIDE 15'-0" FT 15'-0" FT REAR LANDSCAPING TBD SOFTSCAPE SQ FT HARDSCAPE SQ FT TOTAL SQ FT UPPER LEVEL SETBACK GC -600 1830.60 SF 3827.49 SF TOTAL 3827.49 - 600 = 3227.49 SF 1996.89 SF EXISTING PROPOSED 20'-0" FT 15'-0" FT 15'-0" FT TBD TBD TBD TBD TBD TBD TBD EXISTING PROPOSED MAX. AVAILABLE GRFA = 4326.28 SF, EXISTING GRFA 3227.49 SF, REMAINING BUILDABLE GRFA = 1099.31 SF 15'-0" FT 15'-0" FT UNIT A MAX GRFA (60% OF TOTAL GRFA) GRFA UNIT A = 4326.58 SF .4 X 7210.97 SF = 2884.39 SF N/A N/A N/A N/A PROPOSED GRFA - UNIT B LOWER LEVEL 20'-0" FT FRONT SIDE SIDE 15'-0" FT 15'-0" FT REAR LANDSCAPING TBD SOFTSCAPE SQ FT HARDSCAPE SQ FT TOTAL SQ FT UPPER LEVEL SETBACK GC -600 1360.80 SF 2676.31 SF TOTAL 2676.31 - 600 = 2076.31 SF 1315.51 SF EXISTING PROPOSED 20'-0" FT 15'-0" FT 15'-0" FT TBD TBD TBD TBD TBD TBD TBD EXISTING PROPOSED MAX. AVAILABLE GRFA = 4326.28 SF, EXISTING GRFA 3227.49 SF, REMAINING BUILDABLE GRFA = 1099.31 SF 15'-0" FT 15'-0" FT 1360.80 + 435 = 1795.8 SF 3468.3 SF 1315.51+ 357.5 = 1672.5 SF 3468.3 - 600 = 2868.3 SF SITE COVERAGE 1315.51 SF 1315.51+ 357.5 = 1672.5 SF TOTAL SITE COVERAGE 1830.60 (A) SF + 1315.51(B) SF = 3146.11 SF 1830.60 (A) SF + 1315.51(B) SF + 357.5 SF (NEW) = 3503.61 SF UNIT B UNIT A EXISTING UNIT PROPOSED ADDITION C F G 1 2 3 4 6 7 A B D 5 E 8 595 SF UNIT B UNIT A EXISTING UNIT PROPOSED ADDITION PROPOSED ADDITION PROPOSED DECK C F G 1 2 3 4 6 7 A B D 5 E 8 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 LOT 25 LIONSRIDGE FILING NO. 3 1854 GLACIER COURT VAIL, CO 81657 A0.02 GRFA GRAND TRAVERSE DUPLEX Project Number - 1505 07/02/2015 PERMIT SET 1/8" = 1'-0" 1 LOWER LEVEL B - PROPOSED GRFA 1/8" = 1'-0"2 UPPER LEVEL B - PROPOSED GRFA 07/28/15