HomeMy WebLinkAboutB15-0238_A0-09_1438098840.pdf2X6 DIMENSIONAL
LUMBER
5/8" GYPSUM
WALL BOARD
INTERIOR
SELF FURRING LATH
EXTERIOR
BATT INSULATION,
R-20 MIN.
TWO (2) LAYERS
BUILDING WRAP
STRUCTURAL SHEATHING,
RE: STRUCTURE
W1-2
5/8" GYP. = 40 MIN.
2x6 FRAMING @ 16"
O.C.= 20 MIN.
BATT INSULATION = 15 MIN.
FIRE RATING
(1-HOUR MIN.) :
SHEATHING = 20 MIN.
3 COAT STUCCO SYSTEM
2X6 DIMENSIONAL
LUMBER
5/8" GYPSUM
WALL BOARD
INTERIOR
BOARD AND BATTEN
WOOD SIDING, TO
MATCH EXISTING
EXTERIOR
BATT INSULATION,
R-20 MIN.
BUILDING WRAP
STRUCTURAL SHEATHING,
RE: STRUCTURE
W1-1
5/8" GYP. = 40 MIN.
2x8 FRAMING @ 16"
O.C.= 20 MIN.
BATT INSULATION = 15 MIN.
FIRE RATING
(1-HOUR MIN.) :
SHEATHING = 20 MIN.
5/8" GYPSUM
WALL BOARD
0'-5 1/2"
W2-6
2X6 DIMENSIONAL LUMBER,
SEE PLANS AND WALL TAG FOR
LUMBER SIZE, TYP.
SOUND BATTS
5/8" GYPSUM
WALL BOARD
0'-3 1/2"
W2-4
2X4 DIMENSIONAL LUMBER,
SEE PLANS AND WALL TAG FOR LUMBER
SIZE, TYP.
SOUND BATTS
GENERAL ASSEMBLY AND FINISH SYSTEMS
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not
limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any
discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance
with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product.
Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over
architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location
dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to
installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following
assembly narratives are general.
WALL SYSTEMS:
RATED ASSEMBLIES (@ MAIN & UPPER LEVELS):
F1-W WOOD PLANK ON GYPCRETE
Wood plank installed per manufacturer's specifications, over 1 1/2" thick light concrete underlayment over
1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured
floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "x"gypsum
board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses.
F1-C CARPET ON GYPCRETE
Carpet and pad, installed per manufacturer's specifications, over 1 1/2" thick light weigth concrete underlayment over
1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured
floor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "X" gypsum
board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses.
C1 GYPSUM BOARD CEILING CONSTRUCTION
(1Hr-Rated) UL DESIGN NO. L521 & UL P533
5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses.
(TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies.
CEILING SYSTEMS:
FLOOR SYSTEMS:
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies
prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both
architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound
and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general.
NOTES
* Stone veneer to be installed in strict conformance with ESR Reports (ICC) for manufacturer selected.
Comply with the Rocky Mountain Masonry Institute requirements & specifications for systems not
evaluated by ICC, 2009 International Building Code requirements and industry recognized trade
standards.
** Interior Walls Studs:
4 - 2x4 Wood Studs
6 - 2x6 Wood Studs
8 - 2x8 Wood Studs
RE: See wall tags for stud sizes.
**** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant
non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant
non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where
recommended by manufacturer. Maintain required fire-rating.
Refer to Structural Drawings for Bearing Walls and Shear Walls.
RATED ASSEMBLIES (EXTERIOR):
W1-1 BOARD BATTEN WOOD SIDING @ RATED EXTERIOR WALLS
Wood Siding on weather resistive barrier on (1) layer 5/8" gypsum sheathing @
exterior face of 2x6 wood studs w/ R-20 batt insulation between studs. (1) layer 5/8" gypsum board @
interior face of studs. (Re: Structural for size and spacing of studs and sheathing).
W1-2 STUCCO @ RATED EXTERIOR WALLS
Stucco finish coat over stucco base coat over self-furring metal lathe over two layers of Tyvek building wrap,
2x6 wood studs w/ R-20 batt insulation between studs. (1) layer 5/8" gypsum board @ interior face of
studs. (Re: Structural for size and spacing of studs and sheathing).
NON-RATED ASSEMBLIES (INTERIOR):
W4-*** GYPSUM BOARD PARTITION ON 2 x WOOD STUDS
(Non-Rated)
(1) Layer 5/8" gypsum board**** on each side of 2x wood studs at non-bearing walls demising bedrooms
and living areas. Sound batt insulation. (Re. Structural for size and spacing).
W5- GYPSUM BOARD OVER FURRING
(Non-Rated)
(1) Layer 5/8" gypsum board**** over 1 1/2" metal furring strips @ 16" O.C. with 1 1/2" rigid insulation.
(Re. Structural for size and spacing).
(1Hr-Rated), R-50
R1 SYNTHETIC SHAKE SHINGLE ROOF CONSTRUCTION:
(1-Hr. Fire Rated Assembly UL P533)
50 year composite shingle (min. Class A, ASTM E 108) roofing on 30 lb. felt weather barrier (ice and water
shield to cover entire roof and continue vertically up 30" min. at any vertical intersections with roof) on 15/32"
APA rated structural deck sheathing (U.N.O. on Structural Drawings) over 1 layer structural sheathing over 2x10
dimensional lumber perlins. Perlins to sit on 2x4 spacer. 2x4 spacer to be centered on timber rafters.
See Sheet A5.02. (Re. Structural for size and spacing).
Note: Ice and Water
110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119), Miami
Dade Code Approval
ROOF SYSTEMS:
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
LOT 25 LIONSRIDGE FILING NO. 3
1854 GLACIER COURT
VAIL, CO 81657
A0.09
ASSEMBLIES
GRAND TRAVERSE DUPLEX
Project Number - 1505
07/02/2015
PERMIT SET
3" = 1'-0" 1
WALL ASSEMBLY W1-2 - STUCCO
3" = 1'-0"
1A
WALL ASSEMBLY W1-1 - BOARD AND
BATTEN WOOD SIDING
1 1/2" = 1'-0"
3
WALL ASSEMBLY W4-6 - 2X6 INTERIOR
PARTITION
1 1/2" = 1'-0"
4
WALL ASSEMBLY W4-4 - 2X4 INTERIOR
PARTITION
07/28/15