HomeMy WebLinkAboutB15-0253_E0.0_1438199520.pdfGFCI DUPLEX RECEPTACLE DUPLEX RECEPTACLE; HALF SWITCHED ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED SPECIAL OUTLET AS NOTED SPECIAL OUTLET AS NOTED JUNCTION BOX WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM DIVISION 15 EQUIPMENT POWER CONNECTION FUSED DISCONNECT NON FUSED DISCONNECT MOTOR STARTER ENCLOSED CIRCUIT BREAKER PULL BOX PUSH BUTTON TRANSFORMER PANELBOARD OR LOADCENTER CONTACTOR ELECTRIC MOTOR METER THERMOSTAT ATS AUTOMATIC TRANSFER SWITCH ONE-LINE DIAGRAM SYMBOLS CIRCUIT HOMERUN CONDUIT RUN CONDUIT RUN BELOW GRADE CONDUIT UP CONDUIT DOWN DISCONNECT SWITCH FUSE CIRCUIT BREAKER CURRENT TRANSFORMER METER SURGE SUPPRESSION DEVICE GROUND GF GROUND FAULT PROTECTION ST SHUNT TRIP NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT COLD WATER GROUND CONNECTION BUILDING STEEL GROUND CONNECTION TIMER SWITCH MULTI-OUTLET PLUG STRIP TIME CLOCK PHOTO-CELL SWITCH LIGHTING FIXTURE SYMBOLS WALL MOUNTED LIGHT WALL MOUNTED UP-LIGHT PENDANT MOUNTED LIGHT SURFACE MOUNTED LIGHT MONO-POINT LIGHTING FIXTURE FLUORESCENT STRIP LIGHT WALL MOUNTED LINEAR FLUORESCENT LIGHT WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN EMERGENCY LIGHTS CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN SWITCH THREE-WAY SWITCH LIGHTING CONTROL SYMBOLS EXTERIOR POLE MOUNTED LIGHT EXTERIOR POST (BOLLARD) MOUNTED LIGHT LV LOW VOLTAGE SWITCH S S 3 S PC TC TS SS M T C T PB CB N -- J J J ABBREVIATIONS POWER SYMBOLS DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. ELECTRICAL SYSTEMS LEGEND NOTES:  LIGHT LINEWEIGHT INDICATES EXISTING.  HATCHED AREAS INDICATE DEMOLITION.  'C' ADJACENT TO A DEVICE INDICATES MOUNTING ABOVE COUNTERTOP. AFF AFG AHJ - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AUTHORITY HAVING JURISDICTION AL - ALUMINUM AWG - AMERICAN WIRE GAUGE BFG - BELOW FINISH GRADE C CATV CCTV - CONDUIT - COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM - CLOSED CIRCUIT TELEVISION CKT - CIRCUIT CT - CURRENT TRANSFORMER DISP - GARBAGE DISPOSAL DW - DISHWASHER (E) - EXISTING EM - EMERGENCY EWC - ELECTRIC WATER COOLER FBO GFI FA FACP GRD GC - FIRE ALARM - FIRE ALARM CONTROL PANEL - FURNISHED BY OTHERS - GENERAL CONTRACTOR - GROUND FAULT CIRCUIT INTERRUPTER - GROUND IAW IN ACCORDANCE WITH - IG - ISOLATED GROUND NIC (N) NEW - NOT IN CONTRACT - NL NIGHT LIGHT - NTS NOT TO SCALE - OC PA ON CENTER - PUBLIC ADDRESS - REF REFRIGERATOR - TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR - UG UNO W V UNDERGROUND - UNLESS NOTED OTHERWISE - VOLT - WATT - WP XP WEATHERPROOF - EXPLOSIONPROOF - +18" DEVICE ABOVE FINISH FLOOR (VERIFY W/ ARCH ELEVS) MOUNTING HEIGHT TO CENTERLINE OF - C GENERAL NOTES: 1. CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 2. CONTRACTOR SHALL REVIEW ARCHITECTURAL, MECHANICAL, AND OTHER DRAWINGS PRIOR TO BID. 3. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 4. ALL NEW CONTRUCTION SHALL ADHERE TO REQUIREMENTS OF THE 2014 NATIONAL ELECTRICAL CODE (NEC), 2015 INTERNATIONAL BUILDING CODE (IBC), AND ALL LOCAL BUILDING CODES. IN THE EVENT OF A CONFLICT BETWEEN THE CONSTRUCTION DOCUMENTS AND THE DOCUMENTS LISTED ABOVE, THE CONTRACTOR SHALL CONSULT THE ENGINEER OF RECORD PRIOR TO PROCEEDING WITH THE INSTALLATION IN QUESTION. 5. “PROVIDE” SHALL BE DEFINED AS “FURNISH AND INSTALL.” 6. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 7. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHALL NOT BE USED TO SCALE. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL COORDINATE LIGHT FIXTURES, DEVICES, AND EQUIPMENT LOCATIONS WITH THE WORK OF OTHER TRADES PRIOR TO ROUGH-IN AND/OR INSTALLATION. COORDINATE WITH OTHER TRADES FOR CONNECTIONS TO EQUIPMENT. 8. ALL ELECTRICAL SYSTEM COMPONENTS SHALL BE LISTED OR LABELED BY UNITED LABORATORIES (UL) OR OTHER RECOGNIZED TESTING FACILITY. 9. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 10. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT AND/OR ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 11. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL PROVIDE UPDATED DIRECTORIES FOR ALL PANELBOARDS AND LOAD CENTERS. DIRECTORIES SHALL BE COMPUTER GENERATED USING WORD PROCESSING OR SPREADSHEET GENERATION SOFTWARE AND INSTALLED UNDER CLEAR PLASTIC COVERS. EACH CIRCUIT SHALL BE IDENTIFIED AS TO ITS SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL BE SUFFICIENTLY DETAILED TO DISTINGUISH EACH CIRCUIT FROM ALL OTHERS. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. 12. ALL NEW JUNCTION BOX COVERS SHALL BE CLEARLY LABELED AND IDENTIFIED WITH THE BRANCH CIRCUIT(S) CONTAINED WITHIN, INCLUDING THE SOURCE PANELBOARD NAME, ON THE FACE OF THE JUNCTION BOX COVER. 13. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE UNLESS INDICATED OTHERWISE ON THE DRAWINGS. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 14. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM CONDUIT SIZE IS 3/4”. FOLLOW NEC FOR MAXIMUM NUMBER OF CONDUCTORS PER CONDUIT. CONDUIT SHALL BE OF SUFFICIENT SIZE AND CONDUCTOR QUANTITY SHALL BE LIMITED TO ELIMINATE THE NEED TO DERATE CONDUCTORS. METAL CLAD CABLING IS NOT PERMITTED. 15. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUIVALENT AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL, AND TERMINATION POINTS USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 16. ALL EXIT SIGNS SHALL BE UNSWITCHED. FOR ALL NEW EMERGENCY FIXTURES WITH A BATTERY PACK, PROVIDE AN UNSWITCHED CONDUCTOR TO THE EMERGENCY BATTERY PACK VOLTAGE SENSING LEAD PER MANUFACTURER'S RECOMMENDATIONS. 17. ALL NEW EMERGENCY LUMINAIRES SHALL MEET UL924, AS WELL AS ALL APPLICABLE SECTIONS OF NFPA 101, NEC, AND OSHA ILLUMINATION STANDARDS. 18. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT SUPPLIED. 19. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. 20. CONTRACTOR SHALL GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 21. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 22. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE NECESSARY CORRECTIONS AT NO COST TO THE OWNER. 23. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER, IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 24. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. 25. EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED “FOR GUIDANCE ONLY.” THE CONTRACTOR SHALL FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND INCLUDE IN HIS BID AN ALLOWANCE FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHER WORK AS REQUIRED. LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING LAMPS INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER SPECIFIC NOTES QTY TYPE WM1 FULL CUTOFF, WALL MOUNTED, LED FIXTURE WITH TYPE III DISTRIBUTION, 5000K COLOR TEMP, AND STEALTH GRAY FINISH WALL LED W/ FIXTURE 267 277 KIM ARWX25 D 3 5K 55 UV SG 1 X1 WET LOCATION RATED LED EXIT SIGN WITH GREEN LETTERS. WALL LED W/ FIXTURE 2 277 DUAL LITE EVE U G W E I X2 WET LOCATION RATED,DUAL HEAD, LED EMERGENCY EGRESS LIGHT, WITH HEATER FOR COLD TEMP ENVIRONMENTS AND INTEGRAL BATTERY FOR EMERGENCY OPERATION WALL 2 6W LED W/ FIXTURE 26 277 DUAL LITE DYN 12 I HTR O6L GENERAL NOTES: A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. SPECIFIC NOTES: (1) BIDDING PARTIES MAY PROVIDE BREAKOUT ALTERNATE FIXTURES FOR ENGINEER'S REVIEW. PROVIDE BREAKOUT LINE ITEM PRICE FOR FIXTURE ALTERNATES AS WELL AS PHOTOMETRIC DATA. ALL ALTERNATES SHALL HAVE SAME LUMEN OUTPUT AND LIGHTING DISTRIBUTION. T 30AS 30AF 200AS 200AF 60AS 60AF 100AS 100AS SPARE SPARE T T M PANEL 'EM' PANEL 'RA' PANEL 'LA' PANEL 'TB' EXTERIOR LIGHTING CONTROL DIAGRAM - LCP NO SCALE 120V A PC TC LC&D #GR2432 LIGHTING CONTROL PANEL WITH ASTRONOMICAL CLOCK FUNCTION PHOTOCELL MOUNTED ON SOUTH WALL. SYSTEM TIME CLOCK - 365 DAY/ASTRONOMICAL TIME CLOCK WITH NON-VOLATILE MEMORY. PROVIDE COMPLETE PROGRAMMING OF EACH CHANNEL PER OWNER'S REPRESENTATIVE'S DIRECTION. LIGHTING SHALL BLINK PRIOR TO SHUTTING OFF AT CLOSING. LIGHTING BRANCH CIRCUIT TO LIGHTING FIXTURES SCALE: 1 ELECTRICAL ONE-LINE DIAGRAM (EXISTING) NOT TO SCALE NOTE: ELECTRICAL DISTRIBUTION EQUIPMENT IS EXISTING AND IS SHOWN FOR REFERENCE. PANEL: LA (EXISTING) VOLTAGE: 277/480V, 3PH, 4W MINIMUM BUS: 600 LOCATION: ELECTRICAL ROOM MAIN: MLO MOUNTING: SURFACE MINIMUM AIC: NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO. A B C POLE TRIP A B C TRIP POLE A B C 1 L (E) LVL 1 SOUTH WEST LTS. 20 1 + 20 1 SPARE 2 3 L (E) LVL 1 SOUTH MID LTS. 20 1 + 20 1 L (E) LVL 2 SOUTH WEST LTS. 4 5 L (E) LVL 1 SOUTH MID LTS. 20 1 + 20 1 L (E) LVL 2 SOUTH MID LTS. 6 7 L (E) LVL 1 SOUTH EAST LTS. 20 1 + 20 1 L (E) LVL 2 SOUTH MID LTS. 8 9 + 20 1 L (E) LVL 2 SOUTH EAST LTS. 10 11 L (E) LVL 1 NORTH EAST LTS. 20 1 + 20 1 L (E) LVL 2 NORTH EAST LTS. 12 13 L (E) LVL 1 NORTH WEST LTS. 20 1 + 20 1 L (E) LVL 2 NORTH WEST LTS. 14 15 L (E) LVL 1 NORTH MID LTS. 20 1 + 20 1 (E) LVL 2 NORTH MID LTS. 16 17 + 20 1 (E) LVL 2 NORTH MID LTS. 18 19 4117 L SKATE PARK SOUTH LTS. 20 1 + 20 1 SPARE 20 21 4005 L SKATE PARK NORTH LTS. 20 1 + 22 23 SPARE 20 1 + 24 25 + 45 3 SPARE 26 27 SPARE 20 1 + 28 29 SPARE 20 1 + 30 31 E (E) HEATERS 50 3 + 100 3 (E) TRANSFORMER FOR PANEL 'RA' 32 33 E + 34 35 E + 36 37 M (E) EXHAUST FANS 20 3 + 20 3 (E) EXHAUST FANS 38 39 M + 40 41 M + 42 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 8122 8122 125% 10153 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 10.2 (2) (3) PANEL TOTAL (A): 12 (4) (5) PANEL: RA (EXISTING) VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 225 LOCATION: ELECTRICAL ROOM MAIN: 225/3 CB MOUNTING: SURFACE MINIMUM AIC: NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO. A B C POLE TRIP A B C TRIP POLE A B C 1 1 20 + 80 3 S (E) STORAGE ROOM PANEL 2 3 1 20 + S 4 5 1 20 + S 6 7 E (E) COLORADO WEST B.B. HEATERS 2 20 + 50 2 S (E) COLORADO WEST PANEL 1PH 50A 8 9 E + S 10 11 E (E) HEAT TAPE 1 20 + 20 2 E (E) COLORADO WEST B.B. HEATERS 12 13 E (E) HEAT TAPE 1 20 + E 14 15 E (E) HEAT TAPE 1 20 + 20 1 16 17 1 20 + 20 1 18 19 (E) TRAFFIC GATES 1 20 + 20 1 20 21 1 20 + 20 1 22 23 360 R RECEPTACLES 1 20 + 20 1 24 25 360 R RECEPTACLES 1 20 + 20 1 26 27 1 20 + 20 1 28 29 1 20 + 20 1 30 31 1 20 + 20 1 32 33 1 20 + 20 1 34 35 1 20 + 20 1 E (E) ISLAND GATE CONTR 36 37 1 20 + (E) GAR PANEL 3PH 38 39 E (E) COLORADO WEST B.B. HEATERS 2 20 + 70 2 40 41 E + 42 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 0 125% 0 B. (R) RECEPTACLES 720 720 NEC 220 720 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 0.7 (2) (3) PANEL TOTAL (A): 2 (4) (5) SCALE: 1 NORTH/SOUTH LIGHTING SECTION 1/8" = 1'-0" ROUTE BRANCH CIRCUIT RACEWAY AND FIXTURE JUNCTION BOX ON BACK SIDE (PARKING GARAGE SIDE) OF SPANDREL WALL. CORE DRILL THROUGH SPANDREL WALL AND PROVIDE SLEEVE TO PROTECT CONDUCTORS. MOUNT FIXTURE MOUNTING BRACKET TO SPANDREL WALL WITH ANCHORS APPROPRIATE TO SUPPORT FIXTURE WEIGHT (68LBS.). CONNECTION TO PRECAST CONCRETE SPANDREL WALL SHALL BE PER MANUFACTURER'S RECOMMENDATION. (MIN 1/4" DIA CONCRETE SCREWS WITH 1-1/2" MIN. EMBEDMENT) DO NOT CUT OR DAMAGE EXISTING REINFORCING. MOUNT FIXTURE AT APPROXIMATELY 8025'. MOUNT TYPE 'X2' EMERGENCY LIGHTS AT 8012'. CONNECT NEW BRANCH CIRCUITS TO EXISTING SPARE CIRCUIT BREAKERS. ADDED LOAD ONLY ADDED LOAD ONLY SHEET TITLE: SHEET NUMBER: © MARTIN/MARTIN 2015 Martin/Martin, Inc. considers that design data is only in its final form on plotted drawings with original signatures and professional certification being visibly present on the drawings. Data supplied via computer generated format does not contain this approval or certification. The receiver of electronically transmitted drawings is responsible for verifying the information contained within the electronic data against the recorded or approved documents. The use of electronically transmitted drawings is considered to be at your own risk. Martin/Martin, Inc. assumes no responsibility for any claims or damages resulting from your use of this information. Electronic information is provided for the convenience of the recipient only. The recipient of this file agrees that the information may not be transferred to any other party. PROJECT NO: DATE: REVISIONS SEAL LIONSHEAD PARKING GARAGE SKATEPARK 350 SOUTH FRONTAGE ROAD WEST, VAIL, COLORADO VAIL LIONSHEAD FIL 1 BLOCK 2 LOT 1 M15.0024.S.01 07/17/15 NO. ISSUE DATE COPYRIGHT 2015 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com S:\BGProjects\9620.00 Lionshead Skate Park\Drawings\BGCE\962000E00.dwg Printed By: cadd-drp July 15, 2015 - 1:37pm LC-XXX PERMIT SET 07/17/2015 E0.0 ELECTRICAL COVER SHEET 07/29/15