Loading...
HomeMy WebLinkAboutB15-0253_SP-1.2_1438199520.pdfskate park specialty construction: NOTE: ALL EXPOSED CONCRETE AND SHOTCRETE SURFACES TO BE NATURAL GRAY IN COLOR & SMOOTH TROWEL FINISH UNLESS OTHERWISE NOTED. RECOMMENDED TRANSITION CONSTRUCTION SEQUENCE: 1. INSTALL METAL COPING AND FORMS 2. INSTALL SHOTCRETE, USING THE COPING AND FORMS TO GUIDE PLACEMENT AND SHAPING 3. INSTALL FLATBOTTOM AND TOP DECKS. rebar development lengths 3000psi Top Bars 21" 28" 36" English Bot. Bars ldh Normal Weight Concrete #4 #5 #3 16" 22" 27" 8" 11" 14" ld ld Bot. Bars Top Bars ld 31" 25" 18" ldh ld 14" 19" 24" 7" 9" 12" 4000psi #7 #8 #6 71" 62" 43" 33" 48" 55" 16" 19" 22" 47" 42" 28" 37" 54" 62" 19" 17" 14" #10 #11 #9 98" 89" 80" 62" 68" 75" 25" 27" 30" 65" 59" 53" 69" 77" 85" 26" 24" 21" Rebar Size SKATE PARK FLATWORK SKATE PARK LEDGES & WALLS SKATE PARK SHOTCRETE 6" TOP DECK CONCRETE SLAB REFER TO DETAIL 5 / SP-3.0 CONCRETE STAIRS REFER TO DETAIL 2 / SP-3.3 6" FLATBOTTOM CONCRETE SLAB REFER TO DETAIL 5 / SP-3.0 6" SHOTCRETE TRANSITIONS, BANKS & EXTENSIONS REFER TO DETAILS 1, 2, 3, 4, 7, 8 & 9 / SP-3.0, 6 / SP- 3.1 AND 5 / SP-3.3 GRIND LEDGES REFER TO DETAILS 4 & 5 / SP-3.1 RETAINING WALL REFER TO DETAIL 3 / SP-3.3 TURNDOWN WALL REFER TO DETAIL 4 / SP-3.3 THE FOLLOWING ITEMS HAVE BEEN DEEMED AS SPECIALTY CONSTRUCTION WORK WITHIN THE CONTRACT DOCUMENTS: SHOTCRETE APPLICATION, CUTTING, SCULPTING AND FINISH. COPING/RAIL INSTALLATION CONSISTING OF SETTING TO HORIZONTAL LOCATIONS AND VERTICAL ELEVATIONS. GRIND LEDGE INSTALLATION CONSISTING OF SETTING TO HORIZONTAL LOCATIONS AND VERTICAL ELEVATIONS. ALL WORK RELATED TO THE SPECIALTY CONSTRUCTION OF THE SKATE PARK SHALL BE COORDINATED WITH CALIFORNIA SKATE PARKS PRIOR TO THE START OF CONSTRUCTION. THESE LENGTHS APPLY TYPICALLY UNLESS NOTED OTHERWISE ON PLANS AND/OR DETAILS. CLEAR SPACING BETWEEN PARALLEL BARS MUST BE AT LEAST ONE BAR DIAMETER BUT NOT LESS THAN 1". TOP BARS: HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW. LIGHTWEIGHT CONCRETE: MULTIPLY VALUES IN TABLE BY 1.3. CLASS B SPLICE: ld x 1.3 LAP LENGTH. STAGGER SPLICES MIN. OF 24". notes BY ISSUE DATE No.: SHEET NUMBER 273 North Benson Avenue Upland, California 91786 Phone: 1.800.CA.SKATE Fax: 909.949.1601 www.californiaskateparks.com of 16 LIONSHEAD PARKING GARAKE SKATE PARK 350 SOUTH FRONTAGE ROAD WEST, VAIL, COLORADO0 VAIL LIONSHEAD FIL 1 BLOCK 2 LOT 1 ‹&$/,)251,$ 6.$7(3$5.6  PERMIT SET 7/17/2015 CSP SHEET TITLE THICKENED EDGE REFER TO DETAIL 6 / SP-3.0 EXTENSION REFER TO DETAIL 7 / SP-3.0 SMALL GRIND LEDGE REFER TO DETAIL 4 / SP-3.1 MEDIUM GRIND LEDGE REFER TO DETAIL 5 / SP-3.1 MEDIUM GRIND LEDGE REFER TO DETAIL 5 / SP-3.1 MEDIUM GRIND LEDGE REFER TO DETAIL 5 / SP-3.1 LAYBACK EXTENSION REFER TO DETAIL 6 / SP-3.1 EXTENSION REFER TO DETAIL 7 / SP-3.0 BOUNDARY WALLS PER STRUCTURAL ENGINEER REFER TO S-SERIES, STRUCTURAL DRAWINGS SP-1.2 SKATE PARK CONCRETE MATERIAL PLAN WEST SIDE EAST SIDE concrete material legend 0'-0" Scale: 1" = 8'-0" 4'-0" 8'-0" 8'-0" 16'-0" 5 BOUNDARY WALL UNDERNEATH EXTENSION 07/29/15