HomeMy WebLinkAboutB15-0253_SP-2.2_1438199520.pdfsouth side south side
south side
BY ISSUE
DATE No.:
SHEET NUMBER
273 North Benson Avenue
Upland, California 91786
Phone: 1.800.CA.SKATE
Fax: 909.949.1601
www.californiaskateparks.com
of 16
LIONSHEAD PARKING GARAKE SKATE PARK
350 SOUTH FRONTAGE ROAD WEST, VAIL, COLORADO0
VAIL LIONSHEAD FIL 1 BLOCK 2 LOT 1
&$/,)251,$
6.$7(3$5.6
PERMIT SET
7/17/2015 CSP SHEET TITLE
profile key plan
CODE ANALYSIS FROM THE 2011 WELCOME CENTER DESIGN (SHEET G100)
EXISTING GARAGE OPENING CALCULATIONS
FIRST FLOOR TOTAL PERIMETER ------------------------------------ L = 1,226 LF
PERCENTAGE OF OPENING TO LENGTH OF WALL------------- L = 634.6 LF
PERCENTAGE OF OPENING TO LENGTH OF WALL ---- 51% (IBC SECTION 406.3.3.1 REQUIRES
MINIMUM OF 40 %)
SECOND FLOOR TOTAL PERIMETER -------------------------------- L = 1,226 LF
PERCENTAGE OF OPENING TO LENGTH OF WALL------------- L = 692.7 LF
PERCENTAGE OF OPENING TO LENGTH OF WALL ---- 56% (IBC SECTION 406.3.3.1 REQUIRES
MINIMUM OF 40 %)
FIRST FLOOR TOTAL PERIMETER WALL AREA ----------------- A = 13,486 SF
AREA OF PARKING GARAGE OPENINGS -------------------------- A = 3,144 SF
PERCENTAGE OF OPENING TO WALL AREA ------------ 23% (IBC SECTION 406.3.3.1 REQUIRES
MINIMUM OF 20 %)
SECOND FLOOR TOTAL PERIMETER WALL AREA ------------ A = 13,741 SF
AREA OF PARKING GARAGE OPENINGS -------------------------- A = 3,164 SF
PERCENTAGE OF OPENING TO WALL AREA ------------ 23% (IBC SECTION 406.3.3.1 REQUIRES
MINIMUM OF 20 %)
SP-2.2
SKATE PARK SOUTH
END FENCE PROFILES
existing garage opening calculations for reference:
0'-0"
Scale: 1" = 20'-0"
10'-0"
20'-0"
20'-0"
40'-0"
0'-0"
Scale: 1" = 5'-0"
2'-6"
5'-0"
5'-0"
10'-0"
proposed garage opening calculations as-designed:
FIRST FLOOR OPEN AIR SPACE:
3,144 SF OPEN OUT OF A TOTAL PERIMETER AREA OF 13,486 SF.
SOUTH SIDE (FIRST FLOOR) CLOSED AIR SPACE:
392 CALCULATED SF OF AIR SPACE BLOCKED BY THE NEW SKATE SKATE PARK
+ 54.48 CALCULATED SF OF AIR SPACE BLOCKED BY THE NEW MESHED FENCE
----------------------
= 446.48 SF
THE PERCENTAGE OF OPENING TO WALL AREA IS ABOVE 20%. (IBC 2012, SECTION 406.5.2
REQUIRES MINIMUM OF 20%)
notes
NORTH SIDE SKATE PARK COMPONENTS FALL UNDER THE EXISTING WALL, THEREFORE ONLY 6% OF THE
EXISTING AREA WILL BE CONSIDERED CLOSED AIR SPACE WHERE THE NEW MESH FENCE BE LOCATED.
12
07/29/15