Loading...
HomeMy WebLinkAboutB16-0013_E-MR-103_1457631720.pdfDB T D D D SP D DB LT-01 N4L N4 LT-03 LT-02 LT-02 N1 N2 SP J ACTIVITY Draw Design Manager BY Check P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S EST. 1915 DATE KEY PLAN REVISIONS DESCRIPTION NO. FILE LOG STAMP 2016 © LEO A DALY Company Project No. 012-10378-000 JANUARY 21, 2016 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 GINA ORTEGON LARA RIMES KWAN LEE SUZANNE DARNELL ELECTRICAL ENLARGED PLANS TYPE 2K E-MR-103 3 1 10 9 7 4 10 5 1. PROVIDE ALL EQUIPMENT, MATERIAL, LABOR, SUPERVISION, COSTS, AND SERVICES REQUIRED TO INSTALL COMPLETE AND WORKING SYSTEMS INCLUDING ALL ITEMS AND APPURTENANCES NECESSARY, REASONABLY INCIDENTAL, OR CUSTOMARILY INCLUDED, EVEN THOUGH EACH AND EVERY ITEM IS NOT SPECIFICALLY SPECIFIED OR SHOWN. 2. PROVIDE AN EMPTY CONDUIT RACEWAY, INCLUDING BACKBOXES, FOR ALL TELEPHONE, DATA, TELEVISION, SECURITY, AND FIRE ALARM SYSTEM CABLING REQUIREMENTS. RACEWAYS SHALL BE INSTALLED FROM DEVICE TO NEAREST ACCESSIBLE CEILING SPACE OR ACCESS DOOR LOCATION. 3. PROVIDE AND SECURE ALL CABLING AND CONDUIT RACEWAYS PER NEC AND LOCAL CODE REQUIREMENTS. ALL FITTINGS, BOXES, SLEEVES, AND PENETRATIONS SHALL BE SEALED AND RATED ACCORDINGLY. 4. REFER TO VOLTAGE DROP CHART ON SHEET MR-E-001 FOR WIRING SIZES FOR LONG RUNS OF CIRCUIT. 5. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ELECTRICAL WIRING DEVICES. 6. PROVIDE AND INSTALL LIGHTING FIXTURES IN ACCORDANCE WITH THE ELECTRICAL LIGHTING PLAN AND AS SPECIFIED ON THE ELECTRICAL LIGHTING FIXTURE SCHEDULE; REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS AND DIMENSIONAL DATA. REFER TO ARCHITECTURAL PLANS FOR ALL "LT" FIXTURES FOR SPECIFICATION. 7. PROVIDE PUTTY PADS ON BACK AND SIDES OF EACH OUTLET BOX LOCATED ON A GUESTROOM DEMISING WALL AND THE CORRIDOR DEMISING WALL. 1. REMOVE EXISTING LIGHT FIXTURE. REMOVE WIRING BACK TO HOMERUN BOX. 2. REMOVE EXISTING WALL SWITCH. REMOVE WIRING BACK TO HOMERUN BOX. 3. REMOVE EXISTING RECEPTACLE AND JUNCTION BOX. REMOVE CIRCUIT BACK TO HOMERUN BOX. 4. REMOVE EXISTING FAN. REMOVE CIRCUIT BACK TO HOMERUN BOX. 5. EXISTING DATA/PHONE OUTLET. REMOVE EXISTING JUNCTION BOX, CONDUIT AND WIRING BACK TO SOURCE. 6. REMOVE EXISTING SMOKE DETECTOR. REMOVE WIRING BACK TO MAIN FIRE ALARM BOX IN CORRIDOR. 7. REMOVE EXISTING CIRCUIT ASSOCIATED WITH LIGHTED MIRROR BACK TO HOMERUN BOX. 8. EXISTING HVAC UNIT TO REMAIN. 9. EXISTING FIRE ALARM SPEAKER TO BE RELOCATED. 10. REMOVE EXISTING ELECTRICAL BASE BOARD HEATER AND ASSOCIATED CIRCUIT BACK TO HOMERUN BOX. PROVIDE NEW WIRING TO EXISTING HVAC IN ROOM IF FED FROM BASE BOARD CIRCUIT. 1. PROVIDE NEW FIRE ALARM DEVICES AS SHOWN TO MATCH EXISTING BUILDING STANDARD. TIE IN NEW NOTIFICATION AND INITIATION CIRCUITS ON THE FLOOR. NEW SMOKE/HEAT DETECTOR TO BE SINGLE STATION TYPE WITH HEAT/SMOKE/CARBON MONOXIDE DETECTOR AND SOUNDER BASE. BASIS OF DESIGN: GENTEX 9120T. 2. USE EXISTING SPARE CIRCUITS MADE AVAILABLE AFTER DEMOLITION FOR NEW LOADS. 3. PROVIDE NEW J-BOX WITH 1" CONDUIT WITH PULL STRING TO ACCESSIBLE CEILING OR ACCESS DOOR LOCATION. 4. PROVIDE DOOR JAMB SWITCH IN DOOR FRAME TO TURN LIGHTS ON WHEN DOOR IS OPEN. BASIS OF DESIGN: HUBBEL 2968. 5. NEW LIGHT TO BE MOUNTED UNDER VANITY. ALL PARTS OF LIGHT, CIRCUITING AND DRIVERS TO BE COMPLETELY CONCEALED. POWER TO BE BROUGHT IN FROM WALL UNDER VANITY SUCH THAT IT IS AT THE EDGE OF THE INSIDE OF VANITY AND CONCEALED COMPLETELY THROUGHOUT. 6. PROVIDE NEW CIRCUIT FROM EXISTING PANEL. USE EXISTING SPARE IN THE PANEL OR PROVIDE NEW 20A/1P BREAKER IN THE EXISTING PANEL. 7. PROVIDE NEW WIRED DOORBELL SYSTEM WITH PRIVACY AND HOUSEKEEPING COMMUNICATIONS. INSTALL DOORBELL BUTTON OUTSIDE OF ENTRY DOOR, CHIME AND PRIVACY / HOUSEKEEPING BUTTONS ON INSIDE OF ENTRY DOOR. MOUNT THE SYSTEM 120VAC TO 12VDC TRANSFORMER WITHIN JUNCTION BOX LOCATED IN CLOSET, INTERCONNECT SYSTEM COMPONENTS WITH HARNESS CABLING PER MANUFACTURER SPECIFICATIONS. BASIS OF DESIGN INNCOM #P563 (DOORBELL BUTTON), #P564 (PRIVACY / HOUSEKEEPING BUTTON), #PS564 (120VAC TO 12VDC TRANSFORMER). 8. EXISTING FIRE ALARM SPEAKER RELOCATED. PROVIDE NEW WIRING TO SPEAKER FROM CORRIDOR CIRCUIT. 9. PROVIDE LIGHTED SWITCH. BASIS OF DESIGN: LEVITON 5639-2X. 10. PROVIDE DIMMER SWITCH. BASIS OF DESIGN: LEVITON IPL6-010. 11. PROVIDE USB RECEPTACLE. BASIS OF DEIGN: LEVITON T5832-X. USB RECEPTACLE IS MOUNTED IN THE FACE OF THE MILLWORK IN PRE-CUT OPENINGS BY MILLWORK MANUFACTURER. 12. COMBINATION AV, DATA, POWER 3-GANG TV BACKBOX. BASIS OF DESIGN: ARLINGTON - TVBS507. 13. PORTION OF CIRCUIT SHALL BE CONTROLLED BY THE EXISTING THERMOSTAT. BASIS OF DESIGN: GUESTROOM IS PROVIDED WITH AN EXISTING DOOR CONTACT AND INFRARED SENSOR THAT TRANSMITS SIGNAL TO THE EXISTING THERMOSTAT TO INDICATE OCCUPANCY (THERMOSTAT IS ALSO PROVIDED WITH AN INTEGRAL INFRARED SENSOR TO DETECT MOTION WITHIN THE ROOM). THE EXISTING THERMOSTAT IS PROVIDED WITH SPARE CONTACTS TO CONTROL AUXILIARY LIGHTING LOADS. PORTION OF CIRCUIT SHALL BE ROUTED THROUGH CONTACTS TO EACH LIGHT AND EXHAUST SWITCH LOCATED WITHIN THE GUESTROOM TO ENABLE SUCH DEVICES BASED ON OCCUPANCY. 1. REFER TO MR-E-004 FOR DEMOLITION NOTES. 12 3 3 2 10 8 6 2 13 03/10/16