Loading...
HomeMy WebLinkAboutB16-0013_P-MR-001_1457631720.pdf ACTIVITY Draw Design Manager BY Check P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S EST. 1915 DATE KEY PLAN REVISIONS DESCRIPTION NO. FILE LOG STAMP 2016 © LEO A DALY Company Project No. 012-10378-000 JANUARY 21, 2016 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 GINA ORTEGON LARA RIMES KWAN LEE SUZANNE DARNELL PLUMBING INDEX DETAILS AND NOTES P-MR-001 PLUMBING GENERAL NOTES 1. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND UTILITIES, PIPE SIZES, LOCATIONS, MATERIALS, ETC., BEFORE BID, STARTING WORK OR ORDERING MATERIALS AND INCLUDE MINOR ADJUSTMENTS TO ADAPT DESIGN TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL COST TO THE OWNER. 2. THE CONTRACTOR SHALL COORDINATE THE PLUMBING SYSTEMS INSTALLATIONS WITH WORK OF STRUCTURE, HVAC, ELECTRICAL AND RELATED TRIM, ETC., TO PRECLUDE INTERFERENCE. ALL PLUMBING SHALL BE INSTALLED IN A PROFESSIONAL, NEAT AND WORK MAN LIKE MANNER FOR COMMERCIAL CONSTRUCTION. 3. THE CONTRACTOR SHALL PROVIDE ALL INTERCONNECTING PIPING REQUIRED AND ALL (WATER, WASTE, VENT) FINAL CONNECTIONS FOR FIXTURE AND EQUIPMENT. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND IDENTIFICATION OF ADDITIONAL WORK TO BE PERFORMED BY THE CONTRACTOR. 4. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR EXACT LOCATIONS OF FIXTURES AND EQUIPMENT. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH THE STATE OF TEXAS BUILDING, PLUMBING & MECHANICAL CODES (WITH LATEST REVISIONS) 2012 EDITIONS, AND THE LIFE SAFETY CODE, NFPA 101. 5. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TRIM AND ACCESSORIES FOR A COMPLETE AND FUNCTIONING SYSTEM; REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. PROVIDE INDIVIDUAL SUPPLY VALVES, CONNECTORS, CAST TRAPS, AND RELATED TRIM FOR LAVATORIES, ETC., AS SPECIFIED. 6. DO NOT INSTALL COMBUSTIBLE MATERIALS OR PVC PIPING IN RETURN AIR PLENUMS. TRANSITION TO N0-HUB CAST IRON PIPE AND FITTINGS. CONTRACTOR SHALL REFER TO HVAC DRAWINGS FOR LOCATIONS OF RETURN AIR PLENUMS. 7. RECONSTRUCT OR PATCH EXISTING CONSTRUCTION, WALLS, CEILINGS, FLOORS, ROOFS, ETC., AND SURFACES DISTURBED TO MATCH EXISTING SURROUNDING CONSTRUCTION AND FINISHES, UNLESS OTHERWISE NOTED. 8. EQUIPMENT AND MATERIALS, ETC., SPECIFIED OR SCHEDULED OR NOTED ON THE DRAWINGS, METHODS DETAILED AND PIPING MATERIALS INDICATED ON THE DRAWINGS SUPERCEDE ONLY ANY CONFLICTING SPECIFICATION ARTICLES AND/OR REQUIREMENTS OF DIVISION 15 REGARDING PLUMBING MATERIALS, METHODS, ETC. THIS INCLUDES MATERIALS SPECIFIED, LEGEND ITEMS REPRESENTED SYMBOLICALLY ON THE DRAWINGS AND IDENTIFIED IN THE LEGEND DESCRIPTIONS. 9. ADJUST FLOW TO SPECIFIED FLOW FOR ALL FIXTURES PER 2012 INTERNATIONAL PLUMBING CODE. METERING FAUCET SHALL OPERATE FOR 10 SECONDS AND MAXIMUM MIXED WATER TEMPERATURE TO BE 110° FAHRENHEIT AT EVERY MIXING FAUCET EXCEPT JANITOR CLOSET FAUCETS. 10. INSTALL ALL PLUMBING MATERIALS, TRIM ACCESSORIES AND RELATED ITEMS IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. 11. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONAL LAYOUTS AND EXACT LOCATIONS OF PLUMBING FIXTURES, FLOOR DRAINS, DOWNSPOUT NOZZLES, AREA DRAINS, ETC. WHERE DIMENSIONS ARE NOT GIVEN CENTERLINE FIXTURE PLACEMENT, MOUNTING HEIGHTS, SPOUT HEIGHTS, ETC., SHALL BE IN COMPLIANCE WITH THE FEDERAL AND STATE OF TEXAS, ADA REQUIREMENTS, TEXAS STATUTES AND THE 2012 INTERNATIONAL BUILDING AND PLUMBING CODES. 12. THE CONTRACTOR SHALL PAY ALL REQUIRED PERMIT, TAP, METER, CROSS-CONNECTION (BACKFLOW PREVENTER) PERMIT AND TEST FEES AND ANY OTHER FEES AS MAY BE REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 13. ALL PIPING AND PIPING ARRANGEMENTS SHALL BE INDICATED ON THE AS-BUILT DRAWINGS, REQUIRED FOR THIS PROJECT. 14. ALL VALVES SHALL BE MADE IN THE USA (DOMESTIC ONLY), FOR BOTH MATERIALS AND ASSEMBLY. DIELECTRIC UNIONS SHALL BE PROVIDED ON EACH SIDE OF THREADED VALVES, CHECK VALVES AND CIRCUIT BALANCING VALVES AND ON THE UPSTREAM SIDE OF SOLDERED VALVES, UNIONS ARE NOT BE REQUIRED ON THREE PIECE UNION FULL PORT BALL VALVES. 15. WHERE VALVES ARE INSTALLED ABOVE CEILING, PROVIDE VISUAL IDENTIFICATION AT CEILING GRID ACCESS OR AT ACCESS PANELS. IDENTIFICATION SHALL BE VISIBLE FROM BELOW CEILING. PROVIDE (ACCESS PANELS, SEE SCHEDULE) AT HARD (GYPSUM BOARD OR PLASTER) CEILINGS TO ACCESS AND MAINTAIN VALVES. 16. PROVIDE FURRED-OUT GYPSUM BOARD WALL ENCLOSURE FOR PLUMBING & PIPING OTHERWISE EXPOSED TO VIEW IN FINISHED SPACES. 17. PROVIDE CAST IRON DEEP SEALING TRAPS BELOW FLOOR DRAINS REGARDLESS OF PIPING MATERIAL. 18. SANITARY OR WASTE BRANCHES IN WALL SERVING LAVATORIES, SINKS, URINALS, HANDSINKS, AND SIMILAR FIXTURES SHALL BE COPPER DWV TUBE AND FITTINGS. WYES, TEES, CROSSES, AND COMBINATION WYE AND 1/8 BENDS AT SANITARY OR WASTE STACKS SHALL BE PROVIDED WITH WASTE ARM ELBOWS IN WALL, ALL OF WHICH SHALL NOT PENETRATE WALL. PROVIDE ELBOWS IN WALL ON WASTE ARMS TO ENSURE STACK FITTING CONCEALMENT. 19. THE CONTRACTOR SHALL COORDINATE PIPING DIAMETER WITH WALL SIZES. WHERE 3" AND 4" PIPING IS INSTALLED IN WALLS, INCREASE THE WALL THICKNESS OR INSTALL AN ARCHITECTURAL ENCLOSURE TO CONCEAL PIPING AND CLEAN OUT HUBS, AS REQUIRED. SHEET DESCRIPTION PLUMBING SHEET INDEX SCALE MR-P-001 PLUMBING SYMBOLS, ABBREVIATIONS AND NOTES NTS MR-P-002 PLUMBING SPECS AND SCHEDULES NTS MR-P-100 PLUMBING OVERALL FLOOR PLANS LEVELS 1 AND 3 1/4" = 1'-0" MR-P-101 PLUMBING ENLARGED PLANS TYPE 4K 1/4" = 1'-0" MR-P-103 PLUMBING ENLARGED PLANS TYPE 2K 1/4" = 1'-0" MR-P-105 PLUMBING ENLARGED PLANS TYPE 1QQ 1/4" = 1'-0" MR-P-107 PLUMBING ENLARGED PLANS TYPE CORRIDOR 1/4" = 1'-0" 1. ALL FIRE PROTECTION WORK SHALL BE IN STRICT ACCORDANCE WITH THE RULES AND REGULATIONS OF THE LOCAL BUILDING CODE GOVERNING FIRE PROTECTION, SHALL CONFORM TO ALL OTHER APPLICABLE REGULATIONS AND SHALL MEET REQUIREMENTS OF INSPECTING AUTHORITIES. 2. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS. EXACT LOCATION SHALL BE COORDINATED WITH ALL TRADES, ARCHITECTURAL DRAWINGS AND GENERAL CONTRACTOR. 3. ALL EXPOSED PIPING PENETRATIONS THROUGH WALLS OR CEILINGS SHALL BE PROVIDED WITH APPROPRIATE FIRE RETARDANT SEALANT AND ESCUTCHEONS. 4. SUBMISSION OF A PROPOSAL SHALL BE EVIDENCE THAT A CAREFUL EXAMINATION OF THE SITE, DRAWINGS & SPECIFICATIONS HAS BEEN MADE AND THE CONTRACTOR IS FAMILIAR WITH THOSE ITEMS AND AREAS THAT WILL PRESENT DIFFICULTY TO THE PERFORMANCE OF THIS CONTRACT. LATER CLAIMS SHALL NOT BE MADE FOR LABOR, EQUIPMENT, ETC NECESSARY TO COMPLETE ALL WORK AS A RESULT OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN. 5. THIS CONTRACTOR SHALL PAY FEES, GIVE NOTICE, FILE NECESSARY DRAWINGS AND OBTAIN PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH WORK UNDER THIS CONTRACT. HE SHALL COMPLY WITH LOCAL LAWS, ORDINANCES, "STATE" OFFICIAL COMPILATION OF CODES, RULES AND REGULATIONS. 6. STORE MATERIALS IN DESIGNATED SPACES. 7. UNNECESSARY NOISE SHALL BE AVOIDED AT ALL TIMES AND NECESSARY NOISE SHALL BE REDUCED TO A MINIMUM. 8. ALL APPLICABLE CODES, LAWS AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS, AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR WHO SHALL INFORM THE OWNER, PRIOR TO SUBMITTING A PROPOSAL, OF ANY WORK OR MATERIALS WHICH VIOLATE ANY OF THE ABOVE LAWS AND REGULATIONS. ANY WORK DONE BY THE CONTRACTOR CAUSING SUCH VIOLATION SHALL BE CORRECTED BY THE CONTRACTOR. 9. THIS CONTRACTOR SHALL KEEP ALL EQUIPMENT AND MATERIALS, AND ALL PARTS OF THE BUILDING, EXTERIOR SPACES AND ADJACENT STREETS, SIDEWALKS AND PAVEMENTS, FREE FROM MATERIAL AND DEBRIS RESULTING FROM THE EXECUTION OF THIS WORK. EXCESS MATERIALS WILL NOT BE PERMITTED TO ACCUMULATE EITHER ON THE INTERIOR OR THE EXTERIOR. 10. SEAL OPENINGS AROUND FIRE PROTECTION WORK AND PIPING THROUGH PARTITIONS, WALLS AND FLOORS (NOT IN SHAFTS) WITH NON-COMBUSTIBLE MATERIAL. 11. PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE AND SAFE INSTALLATION IN FULL CONFORMITY WITH REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION; ALL AS INDICATED ON DRAWINGS AND/OR HEREIN SPECIFIED FOR THE SYSTEMS INCLUDED. WORK SHALL BE INSTALLED IN A NEAT, WORKMANLIKE MANNER. INCLUDE ALL COSTS FOR PERMITS, LICENSES, CERTIFICATES, FILING AND INSPECTIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION. 12. THE CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE TO REPLACE OR REPAIR PROMPTLY AND ASSUME RESPONSIBILITY FOR ALL EXPENSES INCURRED FOR ANY WORKMANSHIP AND EQUIPMENT IN WHICH DEFECTS DEVELOP WITHIN ONE YEAR FROM THE DATE OF ACCEPTANCE BY OWNER, THIS WORK SHALL BE DONE AS DIRECTED BY THE OWNER. THIS GUARANTEE SHALL ALSO PROVIDE THAT WHERE DEFECTS OCCUR, CONTRACTOR WILL ASSUME RESPONSIBILITY FOR ALL EXPENSES INCURRED IN REPAIRING AND REPLACING WORK OF OTHER TRADES AFFECTED BY DEFECTS, REPAIRS OR REPLACEMENTS IN EQUIPMENT SUPPLIED BY THE CONTRACTOR. 13. ALL THE WORK AND EQUIPMENT SHALL BE THOROUGHLY CLEANED AND MADE READY FOR USE. 14. SUPPORT ALL FIRE PROTECTION WORK AND PIPING FROM BUILDING STRUCTURE AND/OR FRAMING IN AN APPROVED MANNER. WHERE OVERHEAD CONSTRUCTION DOES NOT PERMIT FASTENING OF SUPPORTS FOR EQUIPMENT, FURNISH ADDITIONAL STEEL FRAMING. 15. INSTALL WORK SO AS TO BE READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIR. MINOR DEVIATIONS FROM DRAWINGS MAY BE MADE TO ACCOMPLISH THIS, BUT CHANGES WHICH INVOLVE EXTRA COST SHALL NOT BE MADE WITHOUT APPROVAL. 16. ALL PIPING SHALL BE DELIVERED AND STORED AT THE SITE WITH END CAPS ON THE PIPES TO KEEP ANY MATERIAL OUT OF THE INSIDE OF THE PIPE UNTIL THE POINT OF INSTALLATION. 17. GENERAL CONTRACTOR SHALL COORDINATE FINAL FURNITURE/EQUIPMENT HEIGHT ELEVATIONS AND LOCATIONS WITH SPRINKLER CONSTRUCTION. ENGINEER SHALL BE NOTIFIED WHEN FURNITURE/ EQUIPMENT IS LESS THAN 18" TO THE UNDERSIDE OF CEILING. 18. ALL SPRINKLER HEADS TO BE INSTALLED AT CENTER OF TILE UNLESS OTHERWISE NOTED. 19. THE SPRINKLER CONTRACTOR SHALL MAINTAIN EGRESS PATH SPRINKLERS DURING CONSTRUCTION. A FIRE WATCH MUST BE MAINTAINED ANY TIME FIRE DETECTION, ALARM OR SUPPRESSION SYSTEM IS DISABLED. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL DRAWINGS AND DOCUMENTS FOR A HYDRAULICALLY DESIGNED FIRE PROTECTION SYSTEM. FIRE PROTECTION GENERAL NOTES TYPICAL PIPE SUPPORT FROM CLAMP DETAIL SPRINKLER CONNECTION DETAIL TYPICAL PIPE SUPPORT FROM INSERT DETAIL PIPE SLEEVES THROUGH WALL DETAIL RATED PIPE DETAIL 5 3 BU T T -W EL D E D CL A SS 1 2 5 C AST IR O N T H RE A D E D C L A SS 1 2 5 G ALV AN IZ E D CA ST IRO N T H RE AD ED W E L DE D /B O L T E D C A R B O N STE E L F L AN G ED D U C T ILE IR O N G A SKE T E D M EC H A N ICA L J O INT SCH ED U L E 4 0 CA R B O N STE E L B U T T -WE L DIN G FI TT IN G S W ELD E D/B O L T E D GA L V A N IZ E D STEE L F L A N G E D D U CT IL E I RO N G ASKE T E D ME CH A N IC AL J O IN T F L AN G E D W IT H M E CH A N IC AL SEA L T H R E A DE D W /T E FLON B A SED J OI N T C O M PO U N D PR ESSUR E C L A SS 1 5 0 C O A T E D & LI N ED D UC TI LE IRO N SCH E D U L E 4 0 G A LV AN IZE D STE EL, A STM A -53/1 2 0 SCH ED U L E 4 0 C A R B O N STE E L , A STM A-5 3 /1 2 0 1,2 1 1,6,7 1 4" AND LARGER 2" AND SMALLER 2-1/2" AND LARGER 2" AND SMALLER WET SPRINKLER LINES MISCELLANEOUS DRAIN LINES ABOVEGROUND FIRE SERVICE MAINS AND WET FEED MAINS 1. PAINT ALL EXPOSED ABOVEGROUND PIPING. 2. USE WELDED STEEL FLANGES AT VALVES. 3. BRANCH LINE TAKE-OFFS SHALL BE WELED/THREADED OUTLETS EQUAL TO THREAD-O-LET. 4. SPOOL-PIECES SHALL BE FABRICATED COMPLETE WITH WELDED FLANGES AND WELDED BRANCH LINE TAKE-OFFS PRIOR TO GALVANIZING. 5. MECHANICAL JOINT FITTINGS SHALL ONLY BE USED UPSTREAM OF THE ALARM VALVE ON PREACTION SYSTEMS. 6. BRANCH LINE TAKE-OFFS SHALL BE GROOVED OR THREADED OUTLET EQUAL TO VICTAULIC STYLE 920. 7. MECHANICAL GROOVED JOINT COUPLINGS SHALL BE EQUAL TO VICTAULIC FIRELOCK RIGID COUPLING STYLE 009. SCH ED U L E 1 0 BL A C K STE E L , A STM A-1 3 5 O R A STM A -7 9 5 M ALL E A B L E CA ST IR ON M E C H A N IC A L J OI N T A STM A -4 7 D UC TI L E IR O N M E C H A N IC A L J O IN T ASTM A-5 3 6 M A L L E A B L E C A ST IR O N M E C H A N IC A L J O IN T A STM A -47 D UC T IL E IR O N M EC H A N IC A L J O IN T ASTM A -5 3 6 · ALL PIPE AND FITTINGS SHALL BE OF DOMESTIC MANUFACTURE AND MEET THE REQUIREMENTS OF SPECIFICATIONS. NOTES: 2 CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL DRAWINGS AND DOCUMENTS FOR A HYDRAULICALLY DESIGNED FIRE PROTECTION SYSTEM. NOTES JOINTS FITTINGS PIPE LINE SIZE PIPING MATERIALS AND APPLICATIONS SCHEDULE SERVICE 4 1 SIDE BEAM CLAMP SIDE BEAM CLAMP STRUCTURAL BEAM THREADED ROD STRUCTURAL BEAM THREADED ROD FOR 2" PIPE AND LARGER DOUBLE LOCKNUTS FOR 2" PIPE AND SMALLER DOUBLE LOCKNUTS ADJUSTABLE SWIVEL RING HANGER UP TO 2" GALVANIZED GALVANIZED THREADED ROD BAND HANGER DOUBLE LOCKNUTS SIMILAR TO GRINNEL FIG. 136 THREADED ROD CONNECTOR DOUBLE LOCKNUTS GALVANIZED CLEVIS HANGER THREADED ROD FOR 2 1/2" PIPE AND LARGER SLEEVE OF SIZE TO PASS PIPE. STANDARD WEIGHT STEEL PIPE FINISHED ESCUTCHEON PLATE FLUSH COMPLETELY COVER OPENING AGAINST WALL AND OF SIZE TO PIPE TO BE INTERIOR WALLS CONCEALED PIPING ESCUTCHEON WALL SURFACES CENTERED IN SLEEVE - DO NOT SUPPORT PIPE FROM SLEEVE A SMOKE TIGHT MANNER SEAL OR CAULK SLEEVE THRU FIRE WALLS IN FLUSH WITH FINISHED TERMINATE SLEEVE FINISHED WALL SURFACE PIPING EXPOSED TO VIEW 1" NIPPLE 1" BRANCH TEE BRANCH LINE 1"xi" REDUCER UPRIGHT SPRINKLER HEAD 1" DROP NIPPLE 1"xi" REDUCER (OF TYPE SPECIFIED) HUNG CEILING UPRIGHT CONCEALED COVER PLATE WITH COUPLER, REFERENCE PROVIDE 5/8"Ø EXP. ANCHOR STRUCTURAL DRAWING. SCH 40 STEEL PIPE SLEEVE 2 PIPE SIZES LARGER THAN RISER 2" LOCATIONS FIRE RATED WALL ASSEMBLY. REFER TO ARCH. DWGS. FOR FILL WITH FIREPROOF "THERMAFIBER" SAFING INSULATION (BY US GYPSUM), OR APPROVED EQUAL 2" CLEVIS HANGER 03/10/16