Loading...
HomeMy WebLinkAboutB16-0013_P-MR-003_1457631720.pdf ACTIVITY Draw Design Manager BY Check P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S EST. 1915 DATE KEY PLAN REVISIONS DESCRIPTION NO. FILE LOG STAMP 2016 © LEO A DALY Company Project No. 012-10378-000 JANUARY 21, 2016 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 GINA ORTEGON LARA RIMES KWAN LEE SUZANNE DARNELL PLUMBING ABBREVIATIONS AND SYMBOLS P-MR-003 -O- O2 OXYGEN OD OUTSIDE DIAMETER OF/CI OWNER FURNISHED / CONTRACTOR INSTALLED OF/OI OWNER FURNISHED / OWNER INSTALLED OFD OVERFLOW DRAIN OP OPERATING OR OPERATING ROOM ORD OVERFLOW ROOF DRAIN OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION OSHPD OFFICE OF STATEWIDE HEALTH PLANNING DEVELOPMENT -P- PCU PATIENT CARE UNIT PDISCH PUMP DISCHARGE PE POYETHELENE PH ACID/ALKALINE SCALE PICU PEDIATRIC INTENSIVE CARE UNIT PIV POST INDICATOR VALVE PLBG PLUMBING PNEU PNEUMATIC POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH PSIA POUNDS PER SQUARE INCH ABSOLUTE PSIG POUNDS PER SQUARE INCH GAGE -R- R RADIUS R REMOVE R RISER RD ROOF DRAIN RE RELOCATED EXISTING REF REFERENCE REQ REQURED RFI REQUEST FOR INFORMATION RPM REVOLUTIONS PER MINUTE RWL RAIN WATER LEADER -S- S SINK SAN SANITARY SCFM STANDARD CUBIC FEET PER MINUTE SCHED SCHEDULE SCP SCUPPER SCSK SCRUB SINK SD SCHEMATIC DESIGN SD STORM DRAIN SF SQUARE FOOT (FEET) SH SHOWER SHR SHOWER SHR HD SHOWER HEAD SHRD SHOWER DRAIN SLV SLEEVE SMP SUMP PUMP SOLV SOLENOID VALVE SOV SHUT OFF VALVE SP STANDPIPE SP GR SPECIFIC GRAVITY SPEC SPECIFICATION SPKLR SPRINKLER SS SANITARY SEWER SS SERVICE SINK SS STORM SEWER SSD SUBSOIL DRAIN SST STAINLESS STEEL STRUCT STRUCTURAL SUCT SUCTION -T- T&P TEMPERATURE AND PRESSURE VALVE T/S TUB/SHOWER TC TIME CLOCK TD TRENCH DRAIN TDH TOTAL DYNAMIC HEAD TEMP TEMPERATURE TFA TO FLOOR ABOVE TFB TO FLOOR BELOW THRU THROUGH TS TAMPER SWITCH TYP TYPICAL -U- UBC UNIFORM BUILDING CODE UC UNDERCOUNTER UFC UNIFORM FIRE CODE UG UNDERGROUND UL UNDERWRITERS LABORATORIES UN UNLESS NOTED UNO UNLESS NOTED OTHERWISE UON UNLESS OTHERWISE NOTED UPC UNIFORM PLUMBING CODE UR URINAL UST UNDERGROUND STORAGE TANK UTIL UTILITY -V- V VOLT V VENT VAC VACUUM VAC VACUUM LINE VAR VARIES VB VACUUM BREAKER VB VALVE BOX VERT VERTICAL VIF VERIFY IN FIELD VOC VOLATILE ORGANIC COMPOUND VOL VOLUME VOLT VOLTAGE VP VACUUM PUMP VRFY VERIFY VRP VACUUM RETURN PUMP VS VENT STACK VTR VENT THROUGH ROOF -W- W WATT W WASTE W WIDE/WIDTH W/ WITH W/O WITHOUT WAG WASTE ANESTHETIC GAS WC WATER CLOSET WC WATER COLUMN WC WL HNG WATER CLOSET, WALL HUNG WCL WL MTD WATER COOLER, WALL HUNG WCO WALL CLEANOUT WF WASH FOUNTAIN WG WATER GAGE WH WALL HUNG WH WALL HYDRANT WH WATER HEATER WHA WATER HAMMER ARRESTOR WL WATER LINE WM WATER METER WP WATER PUMP WPR WORKING PRESSURE WSP WORKING STEAM PRESSURE WT WEIGHT WTR WATER WW WASTE WATER -Y- YCO YARD CLEANOUT YD YARD DRAIN YD YARD DRAINAGE PIPE YI YARD INLET FPM FEET PER MINUTE FPS FEET PER SECOND FPW FIRE PROTECTION WATER SUPPLY FR FIRE RATING FRA FIRE RATED ASSEMBLY FRP FIBER GLASS REINFORCED PLASTIC FS FULL SIZE FSH FIRE SPRINKLER HEAD FSP FIRE STANDPIPE FT FOOT/FEET FTG FOOTING FURN FURNISH FUT FUTURE FV FLUSH VALVE FW FIRE WALL -G- G NATURAL GAS G DISP GARBAGE DISPOSAL GCO GRADE CLEANOUT GDR GUARD RAIL GEN GENERAL GIP GALVANIZED IRON PIPE GL GROUND LEVEL GLV GLOBE VALVE GOVT GOVERNMENT GPF GALLONS PER FLUSH GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GPR GAS PRESSURE REGULATOR GPS GALLONS PER SECOND GR FL GROUND FLOOR GR/GAL GRAINS PER GALLON GRV GROOVE GV GATE VALVE GVTR GAS VENT THROUGH ROOF GWH GAS FIRED WATER HEATER -H- H2O WATER H&CW HOT AND COLD WATER HB HOSE BIBB HD HEAVY DUTY HD HUB DRAIN HDR HEADER HE HELIUM HG MERCURY HOSP HOSPITAL HP HIGH PRESSURE HP HORSEPOWER HPG HIGH PRESSURE GAS HR HOUR HS HAND SINK HV HOSE VALVE HVAC HEATING, VENTILATION, AND AIR CONDITIONING HW HOT WATER HWCP HOT WATER CIRCULATING PUMP HWR HOT WATER RETURN HWS HOT WATER SUPPLY HWT HOT WATER TANK HX EXCHANGER HYD HYDRANT -I- IBC INTERNATIONAL BUILDING CODE ICU INTENSIVE CARE UNIT ID INSIDE DIAMETER IE INVERT ELEVATION IN. INCH IND INDUSTRIAL IPS INTERNATIONAL PIPE STANDARD ISO ISOMETRIC IT INFORMATION TECHNOLOGY IW IRRIGATION WATER -J- JC JANITOR CLOSET -K- KW KILOWATT -L- L/S LITER PER SECOND LAB LABORATORY LAV LAVATORY LBS POUND(S) LDR LEADER LF LINEAR FEET (FOOT) LGTH LENGTH LH LATENT HEAT LH LEFT HAND LHR LEFT HAND REVERSE LHS LEFT HAND SIDE LIM SW LIMIT SWITCH LIN LINEAR LIQ LIQUID LL LEAD LINED LNG LIQUID NATURAL GAS LOG LOGARITHM LOP LUBRICATING OIL PUMP LOX LIQUID OXYGEN LP LOW PRESSURE (MECHANICAL) LPAS LOW PRESSURE ALARM SWITCH LPB LOW PRESSURE BOILER LPCR LOW PRESSURE CONDENSATE RETURN LPDT LOW PRESSURE DRIP TRAP SET LPF LOW POWER FACTOR LPG LIQUID PETROLEUM GAS LPG LOW PRESSURE GAS LPL LIGHTPROOF LOUVER LPR LOW PRESSURE RETURN LPS LOW PRESSURE STEAM LT WT LIGHT WEIGHT LTHW LOW TEMPERATURE HOT WATER LUB LUBRICATE LV LABORATORY VACUUM LW LOW WATER LWCO LOW WATER CUT OFF LWM LOW WATER MARK LWT LEAVING WATER TEMPERATURE -M- M METER MA MEDICAL AIR MBH THOUSAND BTU PER HOUR MECH MECHANICAL MER MECHANICAL EQUIPMENT ROOM MFR MANUFACTURER MGD MILLION GALLONS PER DAY MH MANHOLE MIL STD MILITARY STANDARD MIN MINUTE MIN MINIMUM MP MEDIUM PRESSURE MPG MEDIUM PRESSURE GAS MR MOP RECEPTOR MS MOP SINK MU MAKE UP WATER LINE MV MEDICAL VACUUM MV MOTORIZED VALVE -N- N NITROGEN N NORTH N20 NITROUS OXIDE NA NOT APPLICABLE NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFC NATIONAL FIRE CODE NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOISE ISOLATION CLASS NIC NOT IN CONTRACT NO NORMALLY OPEN CMU CONCRETE MASONRY UNIT CNTR COUNTER CO CLEANOUT CO2 CARBON DIOXIDE COL COLUMN COM COMMON COMB COMBINATION, COMBINED COMM COMMUNICATION COMPR COMPRESSOR CONC CONCRETE COND CONDENSATE CONN CONNECT CONSTR CONSTRUCTION CONSULT CONSULTANT CONT CONTROLLER CONTR CONTRACTOR COORD COORDINATE CORR CORRIDOR COTG CLEANOUT TO GRADE COV CUT OFF VALVE CP CONTROL PANEL CPLG COUPLING CPVC CHLORINATED POLYVINYL CHLORIDE CS CLINIC SINK CSI CONSTRUCTION SPECIFICATIONS INSTITUTE CSP CORRUGATED PIPE CSP COATED STEEL PIPE CTG COATING CTRL CONTROL CU COPPER CU FT CUBIC FEET CUH CABINET UNIT HEATER CUR CURRENT CV CONTROL VALVE CW COLD WATER CWP CHEMICAL WASTE PIPE CWP CIRCULATING WATER PUMP CY CYCLE -D- D-B DESIGN BUILD DB DIALYSIS BOX DBA UNIT O FSOUND LEVEL DD DECK DRAIN DD DESIGN DEVELOPMENT DDC DIRECT DIGITAL CONTROL DEF DEFINITION DEG DEGREE DEG F DEGREE FAHRENHEIT DEMO DEMOLITION DES DESIGNATION DESCR DESCRIPTION DET DETAIL DF DRINKING FOUNTAIN DF WL MTD DRINKING FOUNTAIN, WALL MOUNTED DFU DRAINAGE FIXTURE UNIT DGTL DIGITAL DIA DIAMETER DIAG DIAGRAM DIM DIMENSION DIP DUCTILE IRON PIPE DIR DIRECTION DISC DISCONNECT DISCH DISCHARGE DIV DIVISION DIW DEIONIZED WATER DOM DOMESTIC DR DRAIN DSP DRY STANDPIPE DSPL DISPOSAL DW DISHWASHER DW DISTILLED WATER DW DOMESTIC WATER DWG DRAWING DWH DOMESTIC WATER HEATER DWR DOMESTIC WATER RETURN DWS DOMESTIC WATER SUPPLY DWV DRAIN, WASTE, AND VENT DX DUPLEX -E- (E) EXISTING EA EACH ECC RDCR ECCENTRIC REDUCER EER ENERGY EFFICIENCY RATIO EFF EFFICIENCY EHP EFFECTIVE HORSE POWER EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRIC EMER EMERGENCY EMR ELEVATOR MACHINE ROOM EMS EMERGENCY MANAGEMENT SYSTEM ENGR ENGINEER ENGY ENERGY ENVIR ENVIRONMENT EOV ELECTRICALLY OPERATED SOLENOID VALVE EQ EQUAL EQL SP EQUAL SPACED EQUIP EQUIPMENT EQUIV EQUIVALENT ER EXISTING TO REMAIN ERD EXISTING ROOF DRAIN ESC ESCUTCHEON ESH EMERGENCY SHOWER ETR EXISTING TO BE RELOCATED EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EWT ENTERING WATER TEMPERATURE EX EXAMPLE EXCL EXCLUDE EXH EXHAUST EXIST EXISTING EXP EXPANSION EXT EXTERNAL -F- F FAHRENHEIT FACIL FACILITY FCO FLOOR CLEANOUT FCTY FACTORY FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDCC FIRE DEPARTMENT CONNECTION CABINET FDV FIRE DEPARTMENT VALVE FDW FEEDWATER FF EL FINISH FLOOR ELEVATION FFA FROM FLOOR ABOVE FFB FROM FLOOR BELOW FHC FIRE HOSE CABINET FHV FIRE HOSE VALVE FIN FINISH FIN FLR FINISH FLOOR FIN GR FINISH GRADE FIXT FIXTURE FL SW FLOW SWITCH FLASH FLASHING FLEX FLEXIBLE FLG FLANGE FLMT FLUSH MOUNT FLR FLOOR FLR SK FLOOR SINK FLTR FILTER FO FUEL OIL FOF FUEL OIL RETURN LINE FOP FUEL OIL PUMP FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOTK FUEL OIL STORAGE TANK FOUNT FOUNTAIN FOV FUEL OIL VENT FOW FACE OF WALL -A- A AIR A/C ABOVE CEILING A/E ARCHITECT/ENGINEER AAMA AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION ABAN ABANDON ABBRV ABBREVIATION ABRSV ABRASIVE AC ALTERNATING CURRENT AC ACOUSTICAL PANEL CEILING ACC ACCESSIBLE ACHKV AUTOMATIC CHECK VALVE ACID RES ACID RESISTANT ACID RES CI ACIDE RESISTANT CAST IRON ACID RES P ACID RESISTANT PIPE ACID RES V ACID RESISTANT VENT ACID RES W ACID RESISTANT WASTE ACR ACROSS ACS DR ACCESS DOOR ACV AUTOMATIC CONTROL VALVE AD AREA DRAIN ADA AMERICANS WITH DISABILITIES ACT ADDL ADDITIONAL ADDM ADDENDUM ADH ADHESIVE ADJ ADJOINING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFS ABOVE FINISHED SLAB AGA AMERICAN GAS ASSOCIATION AGC ASSOCIATED GENERAL CONTRACTORS AGGR AGGREGATE AHJ ATHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AIA AMERICAN INSTITUTE OF ARCHITECTS ALM ALARM ALNMT ALIGNMENT ALT ALTERNATE ALUM ALUMINUM AMB AMBIENT ANSI AMERICAN NATIONAL STANDARDS INSTITUTE AP ACCESS PANEL APPD APPROVED APPROX APPROXIMATE APPX APPENDIX APR AIR PRESSURE RETURN LINE AR AS REQUIRED ARCH ARCHITECT ARF ARCHITECTURAL FINISH AS AUTOMATIC SPRINKLER ASC ABOVE SUSPENDED CEILING ASD AUTOMATIC SPRINKLER DRAIN ASHRAE AMERICAN SOCIETY OF HEATING, REFERIGERATING ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS ASR AUTOMATIC SPRINKLER RISER ASSN ASSOCIATION ASSY ASSEMBLY ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS ASV ANGLE STOP VALVE ATC ACOUSTICAL TILE CEILING ATCH ATTACHMENT ATTN ATTENTION AUTO AUTOMATIC AUX AUXILIARY AV ACID VENT AV AIR VENT AVG AVERAGE AW ACID WASTE AWL ACID WASTE PIPE AWP AIR WATER PUMP AWWA AMERICAN WATER WORKS ASSOCIATION -B- B&F BELL AND FLANGE B&S BELL AND SPIGOT B/C BELOW CEILING BAL BALANCE BAS BUILDING AUTOMATION SYSTEM BC BUILDING CODE BCV BUTTERFLY CHECK VALVE BFBP BOILER FEED BOOSTER PUMP BFF BELOW FINISHED FLOOR BFP BACKFLOW PREVENTER BFV BUTTERLY VALVE BHP BRAKE HORSE POWER BJT BED JOINT BKG BACKING BKGD BACKGROUND BL BASE LINE BLDG BUILDING BLKHD BULKHD BLO BLOWER BLR BOILER BLR HP BOILER HORSE POWER BLT IN BUILT-IN BLW BELOW BLW CLG BELOW CEILING BLWDN BLOWDOWN BM BEAM BMS BUILDING MANAGEMENT SYSTEM BO BLOWOFF BOCA INTL BUILDING OFFICIAL AND CODE ADMINISTRATORS ASSOCIATION INTERNATIONAL BOS BOTTOM OF STEEL BOT BOTTOM BRCG BRACING BRG BEARING BRZ BRONZE BS BOTH SIDES BSMT BASEMENT BSP BLACK STEEL PIPE BSTR BOOSTER BT WLD BUTT WELD BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR BTWN BETWEEN BV BALL VALVE -C- C CONC CAST CONCRETE C TO C CENTER TO CENTER CAB CABINET CAP CAPACITY CB CATCH BASIN CCU CORONARY CARE UNIT CCW COUNTERCLOCKWISE CD CONSTRUCTION DOCUMENTS CDW CHILLED DRINKING WATER CDWR CHILLED DRINKING WATER RETURN CDWS CHILLED DRINKING WATER SUPPLY CEM CEMENT CERT CERTIFY CF CONTRACTOR FURNISHED CH CHILLER CHEM CHEMICAL CHK CHECK CHKV CHECK VALVE CI CAST IRON CIP CAST IRON PIPE CISP CAST IRON SOIL PIPE CL CENTERLINE CL CLOSE CLASS CLASSIFICATION CLG CEILING CLO CLOSET CLR CLEAR EHW GHW HW WS EW EWS A PIPE-UP UNLESS OTHERWISE NOTED SQUARE FEET DIAMETER VENT THROUGH ROOF UNION CLEANOUT (BURIED PIPING) HOSE BIBB TRAP CLEANOUT (PIPING AT CLG) FLOOR DRAIN/ROOF DRAIN FLOOR DRAIN OVERFLOW ROOF DRAIN ROOF RECEPTOR FLOOR SINK TRENCH DRAIN HUB DRAIN CIRCULATOR PUMP BOOSTER PUMP HOUSE PUMP SUMP PUMP EJECTOR AQUASTAT STORAGE TYPE WATER HEATER WATER SOFTENER POINT OF CONNECTION EMERGENCY EYEWASH INLINE FILTER EXISTING NATURAL GAS (LOW PRESSURE) NATURAL GAS (LOW PRESSURE) GREASE WASTE EXISTING DOMESTIC HOT WATER RETURN PREACTION FIRE SPRINKLER PIPING DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN EXISTING DOMESTIC HOT WATER EXISTING DOMESTIC COLD WATER SEWAGE EJECTOR DISCHARGE UNDERGROUND SANITARY DRAINAGE DOMESTIC COLD WATER EXISTING VENT VENT GREASE VENT EXISTING SANITARY PIPING CONDENSATE DRAIN EXISTING STORM DRAIN OVERFLOW DRAIN STORM DRAIN SANITARY PIPING FILTERED WATER MEDIUM PRESSURE GAS HIGH PRESSURE GAS UNDERGROUND STORM DRAINAGE SUMP PUMP DISCHARGE SUB-SOIL DRAINAGE NON-POTABLE WATER AUTOMATIC FIRE SPRINKLER FIRE LINE EXISTING MEDIUM PRESSURE GAS EXISTING HIGH PRESSURE GAS WALL HYDRANT BACKFLOW PREVENTER BFP VALVE AND CAPPED OUTLET AUTOMATIC AIR VENT VALVE IN VERTICAL (RISE) VALVE IN VERTICAL (DROP) GAS COCK SOLENOID VALVE BALANCING VALVE/GLOBE VALVE CHECK VALVE SHUT-OFF VALVE PRESSURE REDUCING VALVE OS&Y VALVE SHUT-OFF VALVE WITH TAMPER SWITCH BALL VALVE DIAPHRAGM VALVE PLUG SAFETY VALVE FLOAT VALVE MASTER GAS CONTROL VALVE SEISMIC GAS CONTROL VALVE BACK WATER VALVE MIXING FAUCET ELBOW DOWN TEE DOWN CONCENTRIC TRANSITION ECCENTRIC TRANSITION PLUG TRAP PRIMER GAS REGULATOR METER THERMOSTATIC MIXING VALVE TMV M GR TP GRAY WATER RECLAIMED WATER P-501 1 1 1 P-201 2 P-501 1 SYMBOLS P-201 1 GR SSD SED SPD RE SYMBOLS (AS APPLICABLE) EXISTING UNDERGROUND SANITARY DRAINAGE PRESSURE AND TEMPERATURE MIXING VALVE PRESSURE AND TEMPERATURE RELIEF VALVE INSTANTANEOUS GAS WATER HEATER INSTANTANEOUS ELECTRIC WATER HEATER DETAIL REFERENCE DETAIL NUMBER - 1 DETAIL FOUND IN P-501 SHEET KEYNOTE DETAIL BOUNDARY B DETAIL NUMBER - 2 SECTION MARK A2T SECTION NUMBER - 1 SECTION FOUND IN P-501 TITLE MARK DETAIL OR PLAN NUMBER - 1 DETAIL OR PLAN REFERENCE LOCATION FOUND IN P-201 REVISION CLOUD (DELTA 1) SCALE: NOT TO SCALE ANNOTATION FITTINGS PUMPS EQUIPMENT FIXTURES VALVES PIPING SAN SAN (BLW) SD (BLW) (E)SAN SD (E)SD ORD DCW CNDS FW DHW (E)DHW (E)DCW (E)SAN (BLW) DHC DHC NP MPG HPG G G MPG HPG GWV N/A S POINT OF CONNECTION POINT OF DISCONNECTION P 1 EQUIPMENT TAG, DESCRIPTION P MARK NUMBER 1 SYMBOLS (AS APPLICABLE) 03/10/16