HomeMy WebLinkAboutB16-0056 Test & Balance.pdf TEST, ADJUST AND BALANCE REPORT PROJECT VAIL MOUNTAIN SCHOOL #1217 PREPARED FOR SKYLINE MECHANICAL REPORT ISSUE DATE 8/9/2016 PREPARED BY HVAC TAB I l c P.O. BOX 1926 VAIL, CO 81658 PHONE: 970-376-5198 E-MAIL: mrichardson@hvactab.co HVAC TAB IIc TEST, ADJUST AND BALANCE REPORT THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS. ANY VARIANCES FROM THE DESIGN REQUIREMENTS ARE NOTED THROUGHOUT THIS REPORT. THE RESULTS SHOWN AND INFORMATION PRESENTED IN THIS REPORT IS CERTIFIED TO BE ACCURATE AND COMPLETE,TO THE EXTENT POSSIBLE BY EQUIPMENT AND PROCEDURES USED THROUGH- OUT THIS SURVEY. THE FINAL AIR DISTRIBUTION SYSTEM MEASUREMENTS ARE IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS FOR TESTING, ADJUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. CERTIFIED BY: /r7 DATE.: 5/////,''' /G THE FINAL HYDRONIC DISTRIBUTION SYSTEM MEASUREMENTS ARE IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS FOR TESTING,ADUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. CERTIFIED BY: s DATE: HVAC TAB IIc WARRANTS THAT THE AIR AND HYDRONIC SYSTEM EVALUATED DURING THIS SURVEY IS OPERATING AT THE SPECIFIED LEVELS AS SHOWN WITHIN THIS REPORT,AT AND ONLY AT THIS TIME. HVAC TAB IIc MAKES NO OTHER WARRANTIES, STATED OR IMPLIED, CONCERNING THE CONTINUED PERFORMANCE, OPERATION OR SAFETY IN THE USE OF THIS EQUIPMENT PASS THIS TIME. CERTIFIED Michael T.Richardson Page: 1 HVAC TAB.LLC 1113.0M-03 Eapke. V22tZil NATIONAL BALANCING CoUNCil. HVAC TAB I I c INSTRUMENT CALIBRATION REPORT DATE: 8/8/2016 PROJECT: VAIL MOUNTAIN SCHOOL PROJECT ALTITUDE: 22.4"HG INSTRUMENT/SERIAL# APPLICATION DATE OF USE CALIBRATION CALIBRATION DATE DUE DATE SHORTRIDGE ADM-870C/#M00483 AIR FLOW READINGS 8/8/2016 06/08/2015 06/08/2016 ANEMOMETER WIRE#95351535017 AIR FLOW READINGS 8/8/2016 8/28/2015 8/28/2016 SHORTRIDGE FLOW HOOD AIF FLOW READINGS 8/8/2016 * * TH-720 HYGROMETER/#TH7200950003 AIR TEMP/HUMIDITY NOT USED 06/03/2015 06/03/2016 PITOT TUBE 18" PRES.READINGS NOT USED N/A N/A PITOT TUBE 24" PRES.READINGS NOT USED N/A N/A PITOT TUBE 36" PRES.READINGS NOT USED N/A N/A PITOT TUBE 48" PRES.READINGS NOT USED NA NA SHIMPO TACHOMETER /#C 105B0010 RPM READINGS 8/8/2016 06/03/2015 06/03/2016 FLUKE 375/#21290229 VOLT/AMP 8/8/2016 06/03/2015 06/03/2016 SHORTRIDGE HDM-250/#W11037 WATER PRES.READINGS NOT USED 06/08/2015 06/08/2016 ASCROFT/0-100 PSI/#DO68332-06 WATER PRES.READINGS NOT USED * * FLUKE 52 II THERMOMETER/99780167 TEMP.READINGS NOT USED 06/11/2015 06/11/2016 REFRACTOMETER RHA-100 /#RHA- GLYCOL%READINGS NOT USED N/A N/A 100 •CHECKED TO CALIBRATED METER REMARKS: ALL READINGS WITH SHORTRIDGE INSTRUMENTS ARE CORRECTED FOR TEMPERATURE AND ALTITUDE. PAGE: MVAC TAB Ilc AIR APPARATUS TEST REPORT DATE: 8/8/2016 PROJECT: VAIL MOUNTAIN SCHOOL SYSTEM: AHU-5 AIR HANDLER UNIT DATA MOTOR NAMEPLATE DATA MANUFACTURER TRANE MANUFACTURER AO SMITH MODEL MCCB040UA0A0UA HP R.P.M. 20 1745 SERIAL K04A07216 PHASE FRAME 3 5256T FAN TYPE CENTRIFUGAL S.F. TYPE 1.15 MOGB RATING/OUTLET TOTAL - VOLTS AMPS 230/460 49.6/24.8 MIN OSA CFM - THERMALLY PROTECTED - STARTER DATA DRIVE DATA MANUFACTURER NONE MOTOR DRIVE 1 FP 6 1/4" S MODEL NONE MOTOR BORE 1 5/8" S SIZE/THERMAL NO. NONE FAN DRIVE 2 FP 7 1/8" S RANGE (HERTZ) NONE FAN BORE 2 1/8" S SET AT (HERTZ) NONE NO. BELTS & SIZE 2 / 5VX630 REQ. THERMAL NONE ROTATION CORRECT RATING (AMPS) NONE CENTERLINE MOTOR ADJ PULLEY 21" +9 -4 SPEED - AIRFLOW DATA TEST DATA INITIAL FINAL SUPPLY CFM 5318 FAN R.P.M. 1368 1368 OSA CFM - VOLTAGE 479/482/482 479/482/482 RETURN CFM - AMPERAGE 20.1/19.4/20.1 20.1/19.4/20.1 F SWAMP COI -1.41" L -1.49" HL -1.57" -2.02" rJ 0.93" T E R NOTES: PAGE: HVAC TAB Ilc AIR TERMINAL TEST REPORT DATE: 8/8/2016 PROJECT: VAIL MOUNTAIN SCHOOL SYSTEM: AHU-5A SYSTEM TERMINAL DESIGN INITIAL FINAL NOTES PRE-TAB NO TYPE SIZE AK VEL CFM ! VEL CFM VEL CFM AHU-5A 1 CD 15/15 - 238 218 2 CD 15/15 - 250 218 3 CD 15/15 - 264 230 4 CD 15/15 - 266 236 5 CD 15/15 - 270 226 6 15/15 - CD - 252 222 7 CD 15/15 - 252 183 8 CD 15/15 - 222 212 9 CD 15/15 - 248 222 10 CD 15/15 - 252 205 11 SR 13/5.5 - 768 608 12 SR 13/5.5 - 569 553 13 SR 13/5.5 - 537 571 14 SR 13/5.5 - 600 608 15 CD 15/15 - 146 152 DAMPER 1000/0 OPEN 16 CD 15/15 - 316 181 17 CD 15/15 - 0 103 18 SR 11/5 - - 146 DAMPER 15/15 CLOSED 19 CD - 224 - 5450 5318 TOTAL NOTES: PAGE: NIV1Nf OV 1IHn .: :: .94 'U1 j 4";ortm11 t 0 0 0 ''' r 6/ 0 I\ 0 t 7 7 10 7.' ‘.. , ----tr r N---- c 0 I -, ,,,, (.13\ Is:#14 , ' , ,, 1 0 , \ 09 , \,---4_-_---..-.-----..,.-,----- L.__ ' Zr,, /I WI —I 1 e ' '—' '7./,.A . X —07 N (Er4 , I(� ,, �. • it i / ., // \ , ,, .1 / \ . , 1 - l..._, ra'rcr Ff:1,, _ , i.LEO � k nii�F EXIST__DEMO MECHANICAL FLOOR PLA A:CR F,FtiC)!Ai+CN 4