Loading...
HomeMy WebLinkAboutB16-0056_AD-111_1478903404.pdfUP UP UP UP DN DN 1 1 1 2 2 2 2 2 1268 SF EXISTING COMMONS 100 EXISTING LIBRARY 110 2 2 2 2 2 2 DEMO WINDOW AND WALL BELOW WINDOW FOR NEW DOOR. SEE A-111 FOR NEW DOOR HEIGHT. 4 13' - 7 1/2" DEMO END SECTION AT SEAM DEMOLITION GENERAL NOTES GENERAL CONTRACTOR TO COORDINATE SCHEDULING ALL WORK WITH OWNER. WORK LABELED (NIC), OR OTHERWISE NOT NOTED IS NOT IN CONTRACT FOR ANY ARCHITECTURAL IMPROVEMENTS. THE GENERAL CONTRACTOR & THEIR SUBCONTRACTORS SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS WITH CONDITIONS SHOWN IN THE CONTRACT DOCUMENTS AND SHALL REPORT ANY DEVIATIONS, DISCREPANCIES AND/OR CONFLICTS TO ARCHITECT. THE GENERAL CONTRACTOR & SUBCONTRACTOR SHALL TAKE EXTREME CARE DURING DEMOLITION NOT TO DAMAGE OR DISTURB ANY EXISTING CONDITIONS THAT ARE TO REMAIN. GENERAL CONTRACTOR OR SUBCONTRACTOR SHALL REPAIR ANY DAMAGE OR DISTURBANCE TO EXISTING CONDITIONS AT NO COST TO THE OWNER. PROVIDE PROTECTION FOR FLOORS, WALLS, & CEILING AT ALL EXISTING CONDITIONS TO REMAIN, INCLUDING TRAFFIC AREA FOR DEMOLITION REMOVAL IN COMMON BUILDING AREAS & FREIGHT ELEVATORS. DAMAGED FLOORS WILL BE REPLACED @ NO COST TO OWNER. REMOVE ALL WALLS, DOORS AND CASEWORK SHOWN DASHED - FIELD VERIFY CONSTRUCTION OF ALL WALLS TO BE REMOVED - PROVIDE SHORING AND BRACING AS REQUIRED. ALL ITEMS WITHIN WALLS TO BE REMOVED ARE NOT SHOWN - FIELD VERIFY EXISTING CONDITIONS AND TEMPORARILY OR PERMANENTLY REMOVE ITEMS AS NECESSARY FOR NEW CONSTRUCTION. GENERAL CONTRACTOR TO COORDINATE ABATEMENT CONSULTANT FOR ANY CONTAMINATED MATERIALS TO BE REMOVED BEFORE WORK TO BEGIN IN THIS AREA. REFER TO SPECIFICATIONS REGARDING: EXISTING CONDITIONS, CUTTING AND PATCHING AND SELECTIVE DEMOLITION REQUIREMENTS THAT APPLY TO ALL WORK KEY NOTES DESCRIBED ON THIS SHEET. REFER TO ENGINEERS' DEMOLITION DRAWINGS FOR ADDITIONAL ITEMS. COORDINATE W/ BUILDING OWNER DURING DEMOLITION TO DETERMINE WHETHER EXISTING FIRE & SMOKE DETECTION SYSTEMS ARE TO BE BAGGED, PROTECTED & REMAIN IN OPERATION OR TO BE TAKEN OFF LINE. AREAS OF DEMOLITION SHALL BE FREE OF FURNITURE, MOBILE EQUIPMENT AND ACCESSORIES PRIOR TO START OF WORK. REMOVE (STAPLES, NAILS AND SCREWS) FROM WALLS TO REMAIN, TYPICAL THROUGHOUT. REMOVE AND SALVAGE ALL SIGNAGE, CLOCKS, EMERGENCY KITS, PENCIL SHARPENERS AND PHONES FROM WALLS SHOWN TO BE REMOVED. PATCH AND REPAIR WALLS WHERE DAMAGED BY REMOVAL. REMOVE ALL FLOORING INCLUDING ADHESIVES, SETTING MATERIALS, TRANSITION MATERIALS, ETC. AND WOOD WALL BASE. SALVAGE WOOD BASE. PROTECT WALLS FROM DAMAGE. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. CONSULTANT: ISSUE: OWNER: PROJECT: DRAWING INFORMATION: DRAWN BY: PROJECT NO: SHEET TITLE: APPROVED BY: CHECKED BY: SHEET OF 1 2 3 4 5 6 A B C D E 1 2 3 4 5 6 P 303.607.0977 www.hcm2.com 1331 Nineteenth Street Denver, CO. 80202 3/17/2016 4:46:45 PM C:\Revit Local Files\11529_Vail Mountain School_Central_rferrara.rvt AD-111 FIRST FLOOR DEMOLITION PLAN VAIL MOUNTAIN SCHOOL VAIL MOUNTAIN SCHOOL AW RH 11529.000 AW 3000 BOOTH FALLS RD VAIL, CO 81657 3000 BOOTH FALLS RD VAIL, CO 81657 03/15/16 ISSUED FOR CONSTRUCTION DOCUMENTS 1/8" = 1'-0" A3 FIRST FLOOR DEMOLITION PLAN SHEET NOTES - DEMOLITION PLANS NOTE # NOTE 1 REMOVE EXISTING CARPET AND WOOD BASE THROUGHOUT. SALVAGE WOOD BASE FOR REUSE. 2 REMOVE EXISTING WALLS/DOOR/BUILT-IN CASEWORK, SHOWN DASHED. SALVAGE WOOD TRIM FROM DEMO'D CASEWORK FOR RE-USE. 4 OWNER TO SALVAGE ANY EQUIPMENT IN THIS ROOM 05/24/16