HomeMy WebLinkAboutB16-0056_E-1.0_1478906331.pdfGFCI DUPLEX RECEPTACLE
DUPLEX RECEPTACLE; HALF SWITCHED
ISOLATED GROUND DUPLEX RECEPTACLE
WALL MOUNTED SPECIAL OUTLET AS NOTED
SPECIAL OUTLET AS NOTED
JUNCTION BOX
WALL MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER
C
FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE
FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE
FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED
FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM
DIVISION 15 EQUIPMENT POWER CONNECTION
FUSED DISCONNECT
NON FUSED DISCONNECT
MOTOR STARTER
ENCLOSED CIRCUIT BREAKER
PULL BOX
PUSH BUTTON
TRANSFORMER
PANELBOARD OR LOADCENTER
CONTACTOR
ELECTRIC MOTOR
METER
THERMOSTAT
ATS
AUTOMATIC TRANSFER SWITCH
ONE-LINE DIAGRAM SYMBOLS
CIRCUIT HOMERUN
CONDUIT RUN
CONDUIT RUN BELOW GRADE
CONDUIT UP
CONDUIT DOWN
DISCONNECT SWITCH
FUSE
CIRCUIT BREAKER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
METER
SURGE SUPPRESSION DEVICE
VOLT-METER
SELECTOR SWITCH
GROUND
GF
GROUND FAULT PROTECTION
AMP-METER
ST
SHUNT TRIP
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
COLD WATER GROUND CONNECTION
BUILDING STEEL GROUND CONNECTION
TIMER SWITCH
MULTI-OUTLET PLUG STRIP
TIME CLOCK
PHOTO-CELL
SWITCH
THERMAL OVERLOAD SWITCH
VARIABLE SPEED SWITCH
KEY SWITCH
LIGHTING FIXTURE SYMBOLS
RECESSED LIGHTING FIXTURE
WALL MOUNTED LIGHT
WALL MOUNTED UP-LIGHT
PENDANT MOUNTED LIGHT
SURFACE MOUNTED LIGHT
DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE
MONO-POINT LIGHTING FIXTURE
RECESSED STEP LIGHT
FLUORESCENT STRIP LIGHT
WALL MOUNTED LINEAR FLUORESCENT LIGHT
RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER
FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT
WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN
EMERGENCY LIGHTS
CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN
SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
DOOR JAMB SWITCH
LIGHTING CONTROL SYMBOLS
EXTERIOR POLE MOUNTED LIGHT
EXTERIOR POST (BOLLARD) MOUNTED LIGHT
DAYLIGHT PHOTO SENSOR
DL
KEY SWITCH
LV
VARIABLE SPEED SWITCH
DIMMER
THREE-WAY DIMMER
LOW VOLTAGE SWITCH
WALL OCCUPANCY SENSOR/SWITCH
THERMAL OVERLOAD SWITCH
OCCUPANCY SENSOR - WALL MOUNTED
OCCUPANCY SENSOR - CORRIDOR CEILING MOUNTED
S
S
3
S
T
S
O
D
3
D
S
V
S
K
S
J
S
4
S
K
S
V
S
T
S
PC
TC
TS
A
V
SS
M
T
C
T
PB
CB
N
--
J
J
J
ABBREVIATIONS
POWER SYMBOLS
SINGLE RECEPTACLE
DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
NOTE:
ALL SYMBOLS SHOWN ON LEGEND ARE
NOT NECESSARILY USED.
ELECTRICAL SYSTEMS LEGEND
OS
OS
OCCUPANCY SENSOR - CEILING MOUNTED
OS
NOTES:
LIGHT LINEWEIGHT INDICATES EXISTING.
HATCHED AREAS INDICATE DEMOLITION.
'C' ADJACENT TO A DEVICE INDICATES
MOUNTING ABOVE COUNTERTOP.
AFC
AFF
AFG
AHJ
- ABOVE FINISHED CEILING
- ABOVE FINISHED FLOOR
- ABOVE FINISHED GRADE
- AUTHORITY HAVING JURISDICTION
AL - ALUMINUM
AWG
AP - ACCESS POINT
- AMERICAN WIRE GAUGE
BFG
BMS
BAS - BUILDING AUTOMATION SYSTEM
- BELOW FINISH GRADE
- BUILDING MANAGEMENT SYSTEM
C
CATV
CCTV
- CONDUIT
- COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM
- CLOSED CIRCUIT TELEVISION
CKT - CIRCUIT
CPU - CENTRAL PROCESSING UNIT
CT - CURRENT TRANSFORMER
DISP - GARBAGE DISPOSAL
DW - DISHWASHER
(E) - EXISTING
EM - EMERGENCY
EWC - ELECTRIC WATER COOLER
FBO
GFI
FA
FACP
GRD
GC
- FIRE ALARM
- FIRE ALARM CONTROL PANEL
- FURNISHED BY OTHERS
- GENERAL CONTRACTOR
- GROUND FAULT CIRCUIT INTERRUPTER
- GROUND
IAW IN ACCORDANCE WITH
-
IC
IDF
IG
IR
LAN
- INTERMEDIATE CROSS-CONNECT
- INTERMEDIATE DISTRIBUTION FRAME
- ISOLATED GROUND
- INFRARED
- LOCAL AREA NETWORK
NIC
MDF
(N)
MAIN DISTRIBUTION FRAME
-
NEW
-
NOT IN CONTRACT
-
NL
NIGHT LIGHT
-
NTS
NOT TO SCALE
-
OC
PA
ON CENTER
-
PUBLIC ADDRESS
-
REF
REFRIGERATOR
-
TVSS
TTB
TELECOMMUNICATIONS TERMINAL BOARD
-
TRANSIENT VOLTAGE SURGE SUPPRESSOR
-
TVTB
TELEVISION TERMINAL BOARD
-
UG
UNO
W
V
UNDERGROUND
-
UNLESS NOTED OTHERWISE
-
VOLT
-
WATT
-
WP
XP
WAN
WLAN
WAP
WIDE AREA NETWORK
-
WIRELESS ACCESS POINT
-
WIRELESS LOCAL AREA NETWORK
-
WEATHERPROOF
-
EXPLOSIONPROOF
-
+18"
DEVICE ABOVE FINISH FLOOR (VERIFY W/ ARCH ELEVS)
MOUNTING HEIGHT TO CENTERLINE OF
-
C
LUMINAIRE SCHEDULE
TYPE DESCRIPTION MOUNTING INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER
SPECIFIC
NOTES
TYPE
CL1 LED COVE LINEAR COVE LIGHT, PROVIDE EM BATTERY
PACK WHERE INDICATED ON PLANS
COVE LED W/ FIXTURE 15W/FT 277 CORONET CV1S LED XFT LTG1 3500K 277
P1 ROUND LED DECORATIVE PENDANT PENDANT LED W/ FIXTURE 32 277 LF ILLUMINATION RINGER-32L-8040-D2-U
P2 LED LINEAR, PENDANT MOUNTED STRIP LIGHT PENANT LED W/ FIXTURE 34 277 CORONET LS1 LED 4FT LTG1 3500K FL AC
R1 6" ROUND LED RECESSED DOWNLIGHT RECESSED LED W/ FIXTURE 16 277 LIGHTOLIER
P6R D 15 N Z10 U VB
P6R D 8 35 VB
P6R D CC
GENERAL NOTES:
A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS
SHALL NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING
NECESSARY DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING.
B.
REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION (SHOWN BY HATCH IN/OVER SYMBOL). MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600
LUMENS.
C. ALL LAMPS ARE TO BE 3500° KELVIN COLOR TEMPERATURE
SPECIFIC NOTES:
(1)
(2)
(3)
(4)
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF
WORK.
2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS
REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS.
3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN AN
ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL
ADVISED OF SUCH WORK.
4. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION.
5. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID.
6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT.
7. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND
ORDINANCES.
8. PROVIDE PERMITS AND INSPECTIONS REQUIRED.
9. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A
REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.
10. EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED “FOR GUIDANCE ONLY”.
THE ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND TO INCLUDE IN HIS BID AN
ALLOWANCE FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS
INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHER
WORK AS REQUIRED
11. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL AND ELECTRICAL DEMOLITION DRAWINGS FOR
LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF
WORK INVOLVED.
12. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, J-BOXES, RECEPTACLES,
SWITCHES, LIGHTS, FIRE ALARMS DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOT
FEASIBLE TO REMOVE THE ABOVE, OUTLET SHALL BE ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES PROVIDED.
13. ALL (E) EQUIPMENT, LAMPS, BALLASTS, ETC. BEING REMOVED SHALL BE DISCARDED IN ACCORDANCE WITH APPLICABLE EPA
REQUIREMENTS.
14. EXISTING LIGHT FIXTURES, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR
THOSE ITEMS BEING RELOCATED.
15. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN.
16. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT
TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION.
17. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS,
AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE
WITH EQUIPMENT ACTUALLY SUPPLIED.
18. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING
PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.
19. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY.
20. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR
DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT.
21. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL.
CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM CONDUIT SIZE IS 3/4”. FOLLOW NEC FOR MAXIMUM NUMBER OF
CONDUCTORS PER CONDUIT. CONDUIT SHALL BE OF SUFFICIENT SIZE AND CONDUCTOR QUANTITY SHALL BE LIMITED TO
ELIMINATE THE NEED TO DE-RATE CONDUCTORS. METAL CLAD CABLE IS PERMITTED WHEN CONCEALED IN WALL OR CEILINGS.
22. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION,
PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT,
ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT.
23. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS
WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30
DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS.
24.PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF
PROJECT.
25.PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES
SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS.
26.FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED
FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT.
27.EXISTING FIRE ALARM DEVICES TO REMAIN, CONTRACTOR SHALL PROVIDE ALLOWANCE, LINE ITEM BREAKOUT, TO ADD OR ADJUST
ANY FIRE ALARM ANNUNCIATION DEVICES (HORN-STROBES).
28.CONTRACTOR SHALL PROTECT ALL SMOKE DETECTORS IN RENOVATED SPACE FROM CONSTRUCTION DUST.
29.SEE BID NOTES FOR SPECIFIC BID INSTRUCTIONS.
30. ALL DEVICES, LIGHTING FIXTURES, AND OTHER EQUIPMENT SHALL BE CLEANED AFTER CONSTRUCTION COMPLETION AND PRIOR
TO TURNOVER TO OWNER.
AV WALL PLATE DIAGRAM
AV
PLAN SYMBOL: NO SCALE
HDMI
VGA
CUSTOM AV WALL PLATE
WITH HDMI, VGA+A AND
COMPOSITE VIDEO +
AUDIO JACKS.
2"C. COMPOSITE VIDEO,
STEREO AUDIO CABLE,
PREMADE.
VGA+A CABLE,
PREMADE.
HDMI CABLE,
PREMADE.
VIDEO
HUBBELL #HBL260 LARGE
CAPACITY WALL BOX WITH
MUD RING.
SCOPE OF WORK FOR THIS PROJECT IS THE RELOCATION OF EXISTING
RECEPTACLES AND ELECTRICAL DEVICES, ONE-FOR-ONE REPLACEMENT
OF EXISTING FLUORESCENT FIXTURES WITH LOWER WATTAGE LED
FIXTURES. NO ADDITIONAL ELECTRICAL LOAD WILL BE ADDED TO THE
ELECTRICAL SYSTEM AS A RESULT OF THIS PROJECT. 1,710 VA OF
ELECTRICAL RECEPTACLES WERE REMOVED THROUGH DEMOLITION.
CONSULTANT:
ISSUE:
OWNER:
PROJECT:
DRAWING INFORMATION:
DRAWN BY:
PROJECT NO:
SHEET TITLE:
APPROVED BY:
CHECKED BY:
SHEET OF
1 2 3 4 5 6
A
B
C
D
E
1 2 3 4 5 6
P 303.607.0977
www.hcm2.com
1331 Nineteenth Street
Denver, CO. 80202
3/17/2016
4:10:34
PM
C:\Revit
Local
Files\11529_Vail
Mountain School_Central_rferrara.rvt
VAIL MOUNTAIN
SCHOOL
VAIL MOUNTAIN
SCHOOL
Checker
Author
11529.000
Approver
3000 BOOTH FALLS RD
VAIL, CO 81657
3000 BOOTH FALLS RD
VAIL, CO 81657
03/15/16 ISSUED FOR CONSTRUCTION
DOCUMENTS
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www˛bgbuildingworks˛com
Project No. xxxx.xx Copyright 2016
E-1.0
ELECTRICAL COVER
SHEET
MAS
MAS
ELECTRICAL COVER SHEET
07/15/16