HomeMy WebLinkAboutB16-0029_A102 - LEVEL 2 PLAN_1479389479.pdfDN
DN
DN
A202
A203
1
A201 2
1
1
2
3
5
6
7
8
9
10
11
12
13
14
15
16
17
G
G H
D
D
E
E
C
C
B-1
B-1
B
B
A
A
5'-11"
A203
2
RR
A308
2
A201
1
A202
2
A204
2
A408
1
REPLACE (5)INSWING DOORS W/ (3)
SLIDING GLASS DOORS, SEE
WINDOW SCHEDULE, TYP.
REPLACE INSWING PATIO DRS
W/SLIDERS, SEE SCHED.
QQ
PP
NN
**REPLACE ALL WINDOWS AND DOORS.
PRIVATE UNIT WINDOWS AND DOORS BY
OWNER
ALL WOOD SIDING TO BE
REPLACED WITH 3 COAT
STUCCO SYSTEM AND
CEMENTIOUS TRIM
ALL BAY WINDOWS TO KYNAR
PAINTED CLADDING. SEE ELEVATIONS
AND PERSPECTIVES FOR LOCATIONS
PRECAST CONCRETE WALLS
INTEGRAL COLOR SKIMCOATED
STUCCO
STAIR TOWERS CLAD IN
CORRUGATED CORTEN STEEL
PANELS
EXISTING GLU-LAMS TO BE
WRAPPED WITH 2 LAYER GYP.
BOARD AND CLAD WITH WEATHER
RESISTIVE BARRIER AND COPPER
CLADDING (AT ROOF PARAPET
PRECAST CONCRETE WALLS
CLAD WITH HORIZONTAL 8"
CEDAR SLAT SIDING
STAIR TOWERS CLAD IN
CORRUGATED CORTEN
WESTERN RIB STEEL
PANELS
I
F
F J K
BB
AA
CC
DD
EE
HH
GG
FF
JJ
KK
A305
2
12'-0"5'-0"14'-10 1/4"12'-8 3/4"
A205
1
A204
1
STAIR TOWERS CLAD IN
CORRUGATED CORTEN
WESTERN RIB STEEL
PANELS
ALL CAST-IN-PLACE CONCRETE TO
BE PATCHED AND REPAIRED WITH 2
PROCESS EPOXY AND 3 COAT
STUCCO
REPLACE ALL SLOPED GLASS AND
CURTAIN WALL SYSTEM
A310
1
A210
3
A210
4
A210 5
A210
8
A212
83
A213 1A2134A213
6
UUU
XXX
50'-5 5/8"
ZZZ
EXISTING OFFICES AND MAINTANANCE AREAS
OFFICES AND HOUSEKEEPING
PRIVATE PATIO NEW
PAVER REPLACEMENT
(REMOVE EXISTING WOOD
DECK) SEE A305
UNIT
201
UNIT
307LL
UNIT
203
UNIT
103UL
UNIT
107UL
UNIT
109UL
UNIT
109UL
UNIT
321LL
UNIT
202
UNIT
204
UNIT
206
POURED IN PLACE
CONCRETE PATIO
STEPS
NEW
COMPOSITE
DECK
REMOVE AND
REPLACE WATER
PROOFING ON
COVERED PATIO
PLANTING
AREA
A401
8
FRONT
ENTRANCE
ELEVATION
STAIR TOWERS CLAD IN
CORRUGATED CORTEN
WESTERN RIB STEEL
PANELS
NEW GLASS RAILING TO REPLACE WALL RAILING
(TBD IN HOA INTERIOR FINISH PACKAGE)
REPLACE TRAFFIC COATING ON EXTERIOR
LANDINGS; REPAIR/REPAINT RAILINGS; COVER
GLULAM WITH COPPER AND COUNTER FLASH
UNDER TRAFFIC COATING
ALL EXISTING FEATURES OF THE
CURRENT RESTROOMS TO BE
DEMOLISHED
NEW FLOOR INFILL IN CONFERENCE
ROOM
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
4/4/2016 10:42:33 AM
A102
LEVEL 2 PLAN
VAIL SPA
CONDOMINIUMS
MEW
MEW/DW
02/19/2016
VSRP - 2016
710 W. LIONSHEAD CIRCLE
1/16" = 1'-0"
1
LEVEL 2 FLOOR PLAN
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS ARE FULLY SPRINKLERED PER NFPA-13.
SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVELS ARE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE
DEPT- 1 EXISTING BOXES ARE AT FDC LOCATIONS
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP AIR CONDITIONING UNITS UNITS
SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR
SIZE AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED
IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR
KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON
PLANS
12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY
CONSTRUCTED TO MATCH EXISTING, U.N.O
13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
14. (NOTE DELETED -NO NEW STEEL BEARING COLUMNS BEING
ADDED)
15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATE OR MATCH EXISTING
16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR
TRANSITIONS
17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR
LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT
BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN
AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED
BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN.
CLEAR HEIGHT
18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBL
20. ALL EXISTING GLU-LAMS ARE CONSIDERED NON-STRUCUTRAL
AND SHALL BE WRAPPED WITH WEATHER RESISTIVE BARRIER
AND BE CLAD WITH COPPER
21. ALL STOREFRONT AND SLOPED GLAZING TO HAVE .28 U-VALUE
22. ALL NEW RESIDENTIAL DOORS AND WINDOWS TO HAVE .30
U-VALUE
23. SPECIAL INSPECTIONS SHALL INCLUDE SITE-WELDED STEEL AT
ROOF CAPS, AND REBAR REINFORMENT AT POOL AREA
CONCRETE WORK
No. Description Date
1 PROGRESS/PRICIN
G
2 OCT
15
2 DRB REVIEW 12 OCT
15
3 PROGRESS/PRICIN
G 2
23 DEC
15
4 CDs/PERMIT 21 JAN
16
5 CDs/PERMIT 2 19 FEB
16
04/13/16