Loading...
HomeMy WebLinkAboutB16-0029_A102 - LEVEL 2 PLAN_1479389479.pdfDN DN DN A202 A203 1 A201 2 1 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 G G H D D E E C C B-1 B-1 B B A A 5'-11" A203 2 RR A308 2 A201 1 A202 2 A204 2 A408 1 REPLACE (5)INSWING DOORS W/ (3) SLIDING GLASS DOORS, SEE WINDOW SCHEDULE, TYP. REPLACE INSWING PATIO DRS W/SLIDERS, SEE SCHED. QQ PP NN **REPLACE ALL WINDOWS AND DOORS. PRIVATE UNIT WINDOWS AND DOORS BY OWNER ALL WOOD SIDING TO BE REPLACED WITH 3 COAT STUCCO SYSTEM AND CEMENTIOUS TRIM ALL BAY WINDOWS TO KYNAR PAINTED CLADDING. SEE ELEVATIONS AND PERSPECTIVES FOR LOCATIONS PRECAST CONCRETE WALLS INTEGRAL COLOR SKIMCOATED STUCCO STAIR TOWERS CLAD IN CORRUGATED CORTEN STEEL PANELS EXISTING GLU-LAMS TO BE WRAPPED WITH 2 LAYER GYP. BOARD AND CLAD WITH WEATHER RESISTIVE BARRIER AND COPPER CLADDING (AT ROOF PARAPET PRECAST CONCRETE WALLS CLAD WITH HORIZONTAL 8" CEDAR SLAT SIDING STAIR TOWERS CLAD IN CORRUGATED CORTEN WESTERN RIB STEEL PANELS I F F J K BB AA CC DD EE HH GG FF JJ KK A305 2 12'-0"5'-0"14'-10 1/4"12'-8 3/4" A205 1 A204 1 STAIR TOWERS CLAD IN CORRUGATED CORTEN WESTERN RIB STEEL PANELS ALL CAST-IN-PLACE CONCRETE TO BE PATCHED AND REPAIRED WITH 2 PROCESS EPOXY AND 3 COAT STUCCO REPLACE ALL SLOPED GLASS AND CURTAIN WALL SYSTEM A310 1 A210 3 A210 4 A210 5 A210 8 A212 83 A213 1A2134A213 6 UUU XXX 50'-5 5/8" ZZZ EXISTING OFFICES AND MAINTANANCE AREAS OFFICES AND HOUSEKEEPING PRIVATE PATIO NEW PAVER REPLACEMENT (REMOVE EXISTING WOOD DECK) SEE A305 UNIT 201 UNIT 307LL UNIT 203 UNIT 103UL UNIT 107UL UNIT 109UL UNIT 109UL UNIT 321LL UNIT 202 UNIT 204 UNIT 206 POURED IN PLACE CONCRETE PATIO STEPS NEW COMPOSITE DECK REMOVE AND REPLACE WATER PROOFING ON COVERED PATIO PLANTING AREA A401 8 FRONT ENTRANCE ELEVATION STAIR TOWERS CLAD IN CORRUGATED CORTEN WESTERN RIB STEEL PANELS NEW GLASS RAILING TO REPLACE WALL RAILING (TBD IN HOA INTERIOR FINISH PACKAGE) REPLACE TRAFFIC COATING ON EXTERIOR LANDINGS; REPAIR/REPAINT RAILINGS; COVER GLULAM WITH COPPER AND COUNTER FLASH UNDER TRAFFIC COATING ALL EXISTING FEATURES OF THE CURRENT RESTROOMS TO BE DEMOLISHED NEW FLOOR INFILL IN CONFERENCE ROOM Scale Date Drawn By Checked By Project Number 1/16" = 1'-0" 4/4/2016 10:42:33 AM A102 LEVEL 2 PLAN VAIL SPA CONDOMINIUMS MEW MEW/DW 02/19/2016 VSRP - 2016 710 W. LIONSHEAD CIRCLE 1/16" = 1'-0" 1 LEVEL 2 FLOOR PLAN GENERAL PLAN NOTES 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. 2. FURNITURE IS NIC, U.N.O. 3. ALL BUILDING AREAS ARE FULLY SPRINKLERED PER NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES AND GARAGE AND OTHER UNCONDITIONED AREAS. 4. PARKING LEVELS ARE FULLY SPRINKLERED PER NFPA-13. 5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE DEPT- 1 EXISTING BOXES ARE AT FDC LOCATIONS 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL BE COORDINATED WITH STRUCTURAL. 7. PENETRATIONS AT ROOF TOP AIR CONDITIONING UNITS UNITS SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE AND LOCATION. 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT PERPENDICULAR WALL SHALL BE 4" U.N.O. 9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES & GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. BARRIER ON EXT. WHERE SIDING SHOWN). 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04. 11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON PLANS 12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY CONSTRUCTED TO MATCH EXISTING, U.N.O 13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM NOTED FROM FACE OF FINISH TO FACE OF FINISH. 14. (NOTE DELETED -NO NEW STEEL BEARING COLUMNS BEING ADDED) 15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR RATE OR MATCH EXISTING 16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR TRANSITIONS 17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT 18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR RATING, WHEN PART OF PARTITION ASSEMBL 20. ALL EXISTING GLU-LAMS ARE CONSIDERED NON-STRUCUTRAL AND SHALL BE WRAPPED WITH WEATHER RESISTIVE BARRIER AND BE CLAD WITH COPPER 21. ALL STOREFRONT AND SLOPED GLAZING TO HAVE .28 U-VALUE 22. ALL NEW RESIDENTIAL DOORS AND WINDOWS TO HAVE .30 U-VALUE 23. SPECIAL INSPECTIONS SHALL INCLUDE SITE-WELDED STEEL AT ROOF CAPS, AND REBAR REINFORMENT AT POOL AREA CONCRETE WORK No. Description Date 1 PROGRESS/PRICIN G 2 OCT 15 2 DRB REVIEW 12 OCT 15 3 PROGRESS/PRICIN G 2 23 DEC 15 4 CDs/PERMIT 21 JAN 16 5 CDs/PERMIT 2 19 FEB 16 04/13/16